Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Curtain Wall - ES50 SG Brochure

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

ES 50 Structural Glazed

Curtain Wall System

Product Features:

ES 50 SG Curtain Wall System consists of 50 mm wide mullions and


transoms suitable for sloped and vertical facades. The glass panels
are bonded to the aluminium frames with structural silicon sealant
instead of aluminium cap. The external vertical and horizontal
sightline joint will be around 14 to 18 mm.

The speciality of the system is designed to suit continuous EPDM


Gasket covering the complete mullion and transom at glazing
assembly area to achieve high performance in terms of Thermal
Break value, Air and Water tightness.

Euro Systems has variable depth in ES 50 SG curtain wall system


subject to project requirement as per design criteria.

Email : info@eurosystems.co.uk | Web: www.eurosystems.co.uk


ES 50 Structural Glazed
Curtain Wall System

Glazing
The system is glazed from the outside. Glass shall conform to the requirements of BS 6262 for thickness and
type, in terms of wind resistance, safety and security.

Drainage
The system is mullion drained, achieved by meeting the requirements of “Ventilated and drained glazing system”
as specified in BS standards.

Materials
The system is constructed from extruded aluminium profiles, using alloy 6063 complying with the requirements
of BS 1474.

Gasket
The joint seal is made of EPDM, a synthetic rubber gasket compatible with silicon sealants assures water, air and
wind resistance.

Thermal Insulation
Reinforced up to Ucw = 1.6 W/m2K. The lower the U-value is, the better the thermal insulation.

Water Tightness
Resistant to heavy rain in accordance with EN 12154:2000

Air Permeability
Complying with EN 12152:2002

Wind Resistance
Complying with BS EN 13116 – 1000 Pa to 2000 Pa, dependant upon correct mullion and transom selection to
suit span and spacing.

Size Limitations
The size limitation of the system depends mainly on the mullion/transom members used to suit the span,
spacing and wind loads, which are specific for each individual project.
ALUM.MULLION
50 ALUM. TRANSOM LINE
INSIDE

System Cross Section INSIDE OUTSIDE

ES 50 SG
SPANDREL GLAZING PANEL
ALUM.TOGGLE
SPANDREL TRAY CONSIST GLASS SETTING BLOCK
OF ROCK WOOL INSULATION
50

CL

WEATHER SEALANT
WITH BACKER ROD

ALUM.TRANSOM VISION GLAZING PANEL

OUTSIDE CL CONTINUOUS
ALUM.MULLION LINE CONTINUOUS
VISION GLAZING PANEL EPDM GASKET
CONTINUOUS
EPDM GASKET
ALUM.TOGGLE
WEATHER SEALANT
WITH BACKER ROD

TYPICAL MULLION SECTION TYPICAL TRANSOM SECTION

Email : info@eurosystems.co.uk | Web: www.eurosystems.co.uk


Scan code to view on
Smartphone or Tablet device

UNITED KINGDOM
Postal Code: DY10 2AD
Euro Systems UK Ltd. 3 Church St,
Kidderminster, Worcestershire,
United Kingdom

info@eurosystems.co.uk
www.eurosystems.co.uk

Tel: +44 190 260 7111