N Tscgewou 8 7 15kv and 12 20kv Fo Cable
N Tscgewou 8 7 15kv and 12 20kv Fo Cable
N Tscgewou 8 7 15kv and 12 20kv Fo Cable
APPLICATION STANDARDS
Flexible reeling cable with integrated fibre optic wires for high VDE 0250 Part 813, VDE 0295, EN 60228
and extreme mechanical stresses, including torsional stress,
deflection into different planes and high reeling speed. Suitable Flame Retardant according to IEC/EN 60332-1-2
for indoor and outdoor applications.
Test Voltage
8.7/15kV: 24kV
12/20kV: 29kV
Ambient Temperature We've committed to near-term emissions reductions and a net-zero target with the
Fixed: -40°C to +80°C Science Based Targets initiative and we're a signatory to the United Nations Global
Compact Sustainable Development Goals.
Flexed: -25°C to +80°C
Learn more about embodied carbon and our carbon emissions reduction actions,
Maximum Working Speed our comprehensive recycling services, and wider ESG activities for sustainable
120m/min operations at: www.elandcables.com/company/about-us/esg-sustainability
CONSTRUCTION
Phase Conductor
Class 5 tinned copper conductor
Insulation
Rubber compound REGULATORY COMPLIANCE
This cable meets the requirements of the RoHS Directive 2015/65/EU and
Semi-Conductive Layers Reach Directive EC 1907/2006. RoHS compliance has been tested and
Semi-conductive tape over the conductor and inner and outer confirmed by The Cable Lab®.
semi-conductive rubber layer on the insulation
Earth Conductor
Class 5 tinned copper conductor
Fibre Optics
Transmission data kind 50/125 multimode, 62.5/125
multimode, 9/125 singlemode
Rubber compound over the twisted cores
Central Filler
Semi-conductive compound on a textile polyester support
Inner Sheath
Rubber compound
Anti-Torsion Braid
Polyester braid between the inner and outer sheath
Outer Sheath
Rubber compound
Sheath Colour
Red
DIMENSIONS
ELAND PART NO. VOLTAGE NO. OF CORES NOMINAL CROSS SECTIONAL AREA CONDUCTOR MINIMUM MAXIMUM MAXIMUM NOMINAL
kV (PHASE + EARTH mm2 DIAMETER OVERALL OVERALL TENSILE LOAD WEIGHT
+ FIBRE OPTICS) mm DIAMETER DIAMETER N kg/km
Phase Conductor Earth Conductor mm mm
25 139 111 85 68 58 53 38 31
35 172 138 105 84 72 65 46 38
50 216 173 132 106 91 82 58 48
70 265 212 162 130 111 101 72 58
95 319 255 195 156 134 121 86 70
VOLTAGE DROP
NOMINAL CROSS POWER FACTOR
SECTIONAL AREA
mm2 0.7 0.8 0.9 1
VOLTAGE DROP
NOMINAL CROSS POWER FACTOR
SECTIONAL AREA
mm2 0.7 0.8 0.9 1
FIBRE OPTICS
FIBRE GRADED INDEX MULTIMODE FIBRE STEP INDEX SINGLEMODE FIBRE
Attenuation at Attenuation at Bandwidth Bandwidth Numerical Attenuation Attenuation at Chromatic dispersion Chromatic dispersion
850nm 1300nm at 850nm at 1300nm Aperture at 1310nm 1550nm at 1285-1300nm at 1550nm
dB/km dB/km MHz*km MHz*km dB/km dB/km ps/nm km ps/nm km
DE-RATING FACTORS
AMBIENT TEMPERATURE 10ºC 15ºC 20ºC 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC 55ºC 60ºC 65ºC 70ºC 75ºC 80ºC
DE-RATING FACTOR 1.15 1.12 1.08 1.04 1.00 0.96 0.91 0.87 0.82 0.76 0.71 0.65 0.58 0.50 0.41
The information contained within this datasheet is for guidance only and is subject to change without notice or liability. All the information is provided in good faith and is
believed to be correct at the time of publication. When selecting cable accessories, please note that actual cable dimensions may vary due to manufacturing tolerances.