Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

PLC Analog

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Instrumentation Tools

Learn Instrumentation and Control Engineering. Inst Tools covers topics of Industrial
Instrumentation, PLC, DCS, SCADA, Field Instruments, Analyzers and so on.
https://instrumentationtools.com

Author: Instrumentation Tools

Categories: PLC Tutorials

PLC Analog I/O and Network I/O

om
s .c
ol
To
i on
at
nt
me
ru
st
In

In the early days of programmable logic controllers, processor speed and memory were too
limited to support anything but discrete (on/off) control functions. Consequently, the only I/O
capability found on early PLCs were discrete in nature. Modern PLC technology, though, is
powerful enough to support the measurement, processing, and output of analog (continuously
variable) signals.

All PLCs are digital devices at heart. Thus, in order to interface with an analog sensor or control
device, some “translation” is necessary between the analog and digital worlds. Inside every
analog input module is an ADC, or Analog-to-Digital Converter, circuit designed to convert an
analog electrical signal into a multi-bit binary word. Conversely, every analog output module
contains a DAC, or Digital-to-Analog Converter, circuit to convert the PLC’s digital command
words into analog electrical quantities.

InstrumentationTools.com
Instrumentation Tools
Learn Instrumentation and Control Engineering. Inst Tools covers topics of Industrial
Instrumentation, PLC, DCS, SCADA, Field Instruments, Analyzers and so on.
https://instrumentationtools.com

Analog I/O is commonly available for modular PLCs for many different analog signal types,
including:

Voltage (0 to 10 volt, 0 to 5 volt)


Current (0 to 20 mA, 4 to 20 mA)
Thermocouple (millivoltage)
RTD
Strain gauge

om
The following photographs show two analog I/O cards for an Allen-Bradley SLC 500 modular

.c
PLC system, an analog input card and an analog output card. Labels on the terminal cover
doors indicate screw terminal assignments:

s
ol
To
i on
at
nt
me
ru
st
In

Network I/O

Many different digital network standards exist for PLCs to communicate with, from PLC to PLC
and between PLCs and field devices. One of the earliest digital protocols developed for PLC
communication was Modbus, originally for the Modicon brand of PLC.

InstrumentationTools.com
Instrumentation Tools
Learn Instrumentation and Control Engineering. Inst Tools covers topics of Industrial
Instrumentation, PLC, DCS, SCADA, Field Instruments, Analyzers and so on.
https://instrumentationtools.com

Modbus was adopted by other PLC and industrial device manufacturers as a de facto standard,
and remains perhaps the most universal digital protocol available for industrial digital devices
today. Another digital network standard developed by a particular manufacturer and later
adopted as a de facto standard is Profibus, originally developed by Siemens.

Credits : by Tony R. Kuphaldt

om
s .c
ol
To
i on
at
nt
me
ru
st
In

InstrumentationTools.com
Powered by TCPDF (www.tcpdf.org)