Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

NCB C6sgryr 305

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

STRUCTURED CABLING SOLUTIONS

Foil Shield
PVC Sheath
Rip Cord
Copper Conductor
Coloured Insulation
Insulation with
Colour Stripe
Drain Wire

Cat6 23AWG FTP Cable


INTRODUCTION
D-Link solid cables are the best twisted-pair cables in the market for transmitting data over local As streaming video and multimedia over LAN are gaining popularity, users demand faster data
area Networks (LANs). These cables exceed performance requirements specified by the transmission and reduced waiting time. D-Link cables are ideal for simple, cost-effective and
TIA/EIA-568C.2 and IEC 60603-7-4 standards. high-speed transmission performance. They support a higher signal-to-noise ratio, providing
better reliability for current applications and higher data rates for future applications.

CAT6 23 AWG UTP CABLE SPECIFICATIONS APPROVAL / CERTIFICATION


CAT6 cables reduce crosstalk and system noise. The superior • 4 Pairs Shielded Twisted Pair (FTP) Cable • Compliant with TIA/EIA-568C.2
insulation around the 23 AWG copper wires attribute to the • Conductor Metal: Solid Bare Copper standards
increased performance. They can transmit data at 1000 Mbps (~1 • Shield: Aluminum Polyester Foil • CUL listed
Gigabit per second) with a frequency of 250 MHz and suitable for • Color Code: Gray • RoHs
10BASE-T, 100BASE-TX Fast Ethernet and 1000BASE-T / • Conductor Diameter: 0.560mm Nominal, 23 AWG
1000BASE-TX (Gigabit Ethernet). The shield reduces electrical • Insulation Diameter: 1.14 Nominal, Insulation Material: HD-PE
noise from affecting the signals, and to reduce electromagnetic • Drain Wire: 26 AWG
radiation that may interfere with other devices • Jacket Material: PVC UL94V-0
• Cable Diameter : 7.00mm Nominal
• PE Central Cross separator

TECHNICAL DETAILS TRANSMISSION CHARACTERISTICS PER 100M


• Mutual Capacitance: 5.6nF/100m nominal Frequency Insertion Loss RL NEXT PSNEXT ELFEXT PSELFEXT ACR PSACR
• Characteristic Impedance: 100Ω±15% (MHz) (dB/100m) (dB) (dB) (dB) (dB) (dB) (dB) (dB)
• Nominal Velocity of Propagation: 69%
1 2.0 20.0 74.3 72.3 67.8 64.8 72.3 70.3
• Characteristic Impedance: 100+15Ω 4 3.8 23.0 65.3 63.3 55.8 52.8 61.5 59.5
• Conductor Resistance: < 9.38Ω/100m 8 5.3 24.5 60.8 58.8 49.7 46.7 55.5 53.5
• Mutual Capacitance: < 5.6nF/100m 10 6.0 25.0 59.3 57.3 47.8 44.8 53.3 51.3
• Resistance Unbalance: 5% Max 16 7.6 25.0 56.2 54.2 43.7 40.7 48.6 46.6
• Capacitance Unbalance: 330pF/100m 20 8.5 25.0 54.8 52.8 41.8 38.8 46.3 44.3
• Delay Skew: < 45nS 25 9.5 24.3 53.3 51.3 39.8 36.8 43.8 41.8
• Bending Radius: < 4 X Cable Diameter 31.25 10.7 23.6 51.9 49.9 37.9 34.9 41.2 39.2
at –20°C ± 1°C 62.5 15.4 21.5 47.4 45.4 31.9 28.9 32.0 30.0
• Pulling Force: 11.5Kg 100 19.8 20.1 44.3 42.3 27.8 24.8 24.5 22.5
• Temperature Range: -20° to +70°C 200 29.0 18.0 39.8 37.8 21.8 18.8 10.8 8.8
250 32.8 17.3 38.3 36.3 19.8 16.8 5.5 3.5

Product No. Description Color


NCB-C6SGRYR-305 Cat6 FTP 23 AWG solid, 305 Mtr/Roll Gray

www.dlinkmea.com CAT6 23AWG FTP CABLE