Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

LR-C-VentureClad Catalogue 01

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

3M Industrial Adhesives and Tapes

VentureClad ®

Jacketing
Systems
We have you covered.
2

What is VentureClad ®

Jacketing?
VentureClad® jacketing is a zero permeability,
self-adhesive tape which bonds 100% to the surface of
the insulation providing a neat and dependable weather
barrier which reduces corrosion under insulation.

The Industry Standard


o o
• Service Temperatures as low as -94 F (-70 C)
• Zero Permeability
• UL 723/ASTM E 84 Flame and Smoke
• UV Resistant
• No Primers, Activators or Heat Guns required
• Neat, Clean and Dependable Material
3

Why choose
VentureClad®

Jacketing?

Improves Increases
Productivity Protection

• No prefabrication required • 100% Vapor Barrier


• Fast and clean installation • Greatly reduces corrosion
under insulation
• Reduced downtime due to
easy inspection and repair • Excellent resistance to
moisture, salt, chemicals
and UV exposure
4

Overcladding of damaged metal


jacketing with VentureClad® makes
the OLD, NEW again!

The above application shows a chiller that was insulated in a mechanical room with rubber
insulation and covered with VentureClad® 1577CW-WM

The above application shows a heavily oxidized steel duct covered with VentureClad®
1577CW-WM
5

A tape jacketing system that can replace traditional metal


jacketing? We were as unconvinced as you. So, we put
VentureClad® through a series of rigorous tests to prove its
performance in the most extreme scenarios.

Test Description Results

Xenon Arc Extremely harsh UV Rays, simulates long No change in


Weatherometer term weathering performance

Simulates outdoor weather conditions,


Freeze/ ensuring that the adhesive will not crack No change in
Thaw Cycle and remains bonded through the most performance
severe conditions

Immersion No change in
Water, diesel, kerosene and oil type 1
Resistance performance

Chemical No change in
Solvent drip test method
Resistance performance

ASTM E 96 Wet & dry cup test 0.00 Perms

ASTM E 96 Wet cup (overlap seam) 0.00 Perms


6

Since 2000, VentureClad® has been installed globally in a


diverse range of applications. Ranging from cladding for
ducts, pipelines, hot/cold insulation in oil refineries to heat
exchangers in power stations.

Steam Line Pyrogel, Italy Ethylene Plant, Scotland

Asphaltic Tank, Japan Water Tank, USA


7

VentureClad®
can also be applied
on most insulation
materials without
any additional
fabrication or
adhesives

Over mineral wool

Over foam glass

Over calcium silicate

AND MANY MORE!


Find out more at www.3m-iatd.com.sg Over oxidized steel ducts
8

VENTURECLAD ®

PRODUCTS
These products have been designed
keeping architects, engineers and
contractors in mind. In addition
to exceeding most building code
requirements, VentureClad® jacketing
installs quickly and easily on pipe
or duct board with no special tools
required, delivering significant time,
labor and cost savings.
3M Industrial Adhesives and Tapes 9

VentureClad®
1577CW
(Natural Aluminium)
• Lightweight alternative to metal (aluminum, galvanized
steel) jacketing
• -94°F to 300°F (-70°C to 149°C) service temperature
• High puncture and tear resistance
• Applies easily at temperatures as cold as -23°C
• Passes ASTM C 1338 Fungi Resistance Testing; LD
contains tested and approved mold inhibiting agents MO

Technical Data (Typical values for natural aluminium grade, not for specification purposes)
Specification Typical Value Typical Value (Metric) Test Method

Material Thickness 7.0 mils 0.18 mm PSTC-133

Adhesive Peel Strength 65 oz/in 18 N/25mm PSTC-101

Adhesive Shear Strength >24 hours >24 hours PSTC-107

Tensile Strength 69 lb/in 312 N/25mm PSTC-131

Elongation 80% 80% PSTC-131

Puncture Resistance 30 lb 133.4 N ASTM D 1000

Tear Strength 8.5 lb 38.3 N ASTM D 624

Service Temperature -94°F to 300°F -70°C to 149°C

Flame Spread/Smoke Developed 10/20 10/20 UL 723

Surface Flammability Using Radiant Heat 0 0 ASTM E 162

Specific Optical Density of Smoke 0 0 ASTM E 662

Water Vapor Permeability 0.0000 perms 0.0000 perms ASTM E 96

Product & Specification Approvals


• Exceeds standard building design requirements (UL 723 10/20 Flame Spread/
Smoke Rating)
• Meets requirements of GSA Facilities Standard PBS-100
• LEED Credit under USGBC Rating System - contributes to Environment Quality
Credit 4.1: Low emitting Materials, Adhesive and Sealant
• U.S. Coast Guard 164.112/63/0
• British Standards BS 476, Parts 6 & 7, Class O
• IMO Fire Test Procedures Code Annex 1, Part 5 and Annex 2
• Lloyds of London Approved
• Meets requirements of SOLAS
• ROHS Compliant
• IMO Resolution A653 (16)
• German DIN 4102, B1
• New York City School Construction Authority
• New York City MEA
• South Africa BS-SANS 10177 Part 3, Class 1
• Netherlands CINI 3.3.12 Requirement
• VA Approval
• Japanese Building Standard Law Article 2 Clause 9
• Fire behavior tested per European Norm EN 13501-1:2007+A1: 2009 for building
materials and classified as Euroclass B-s1, d0
• Meets New York City MTA requirements for Insulation and Insulation Jacketing
10

VentureClad®
1577CW-BM (Black)

1577CW-WM (White)
• Resistant to salt, certain chemicals and highly UV resistant
• Meets FDA compositional requirements for indirect food contact
• Lightweight alternative to metal (aluminum, galvanized steel) jacketing
• -94°F to 248°F (-70°C to 120°C) service temperature
• High puncture and tear resistance
• Applies easily at temperatures as cold as -23°C
• Passes ASTM C 1338 Fungi Resistance Testing; contains tested
and approved mold inhibiting agents OLD
M

Technical Data (Typical values, not for specification purposes)


Specification Typical Value Typical Value (Metric) Test Method

Material Thickness 8.0 mils 0.20 mm PSTC-133

Adhesive Peel Strength 65 oz/in 18 N/25mm PSTC-101

Adhesive Shear Strength >24 hours >24 hours PSTC-107

Tensile Strength 70 lb/in 316 N/25mm PSTC-131

Elongation 80% 80% PSTC-131

Puncture Resistance 30 lb 133.4 N ASTM D 1000

Tear Strength 8.5 lb 38.3 N ASTM D 624

Service Temperature -94°F to 248°F -70°C to 120°C

Flame Spread/Smoke Developed 25/45 25/45 ASTM E 84

Surface Flammability Using Radiant Heat 0 0 ASTM E 162

Specific Optical Density of Smoke 0 0 ASTM E 662

Water Vapor Permeability 0.0000 perms 0.0000 perms ASTM E 96

Product & Specification Approvals


• ASTM E 84 (25/45 Flame/Smoke Rating)
• Meets requirements of GSA Facilities Standard PBS-100
• LEED Credit under USGBC Rating System - contributes to Environment Quality
Credit 4.1: Low emitting Materials, Adhesive and Sealant
• U.S. Coast Guard 164.112/63/0
• British Standards BS 476, Parts 6 & 7, Class O
• IMO Fire Test Procedures Code Annex 1, Part 5 and Annex 2
• Lloyds of London Approved
• Meets requirements of SOLAS
• ROHS Compliant
• IMO Resolution A653 (16)
• German DIN 4102, B1
• New York City School Construction Authority
• New York City MEA
• South Africa BS-SANS 10177 Part 3, Class 1
• Netherlands CINI 3.3.12 Requirement
• VA Approval
• Japanese Building Standard Law Article 2 Clause 9
• Fire behavior tested per European Norm EN 13501-1:2007+A1: 2009 for building
materials and classified as Euroclass B-s1, d0
• Meets New York City MTA requirements for Insulation and Insulation Jacketing
11

VentureClad®
1578CW
(Natural Aluminium)
• Low temperature vapor barrier joint closure system for easier
taping of bends in insulation
• -94°F to 300°F (-70°C to 149°C) service temperature
• High puncture and tear resistance
• Passes ASTM C 1338 Fungi Resistance Testing; contains tested
and approved mold inhibiting agents MOLD

Technical Data (Typical values for natural aluminium grade, not for specification purposes)
Name Typical Value Typical Value (Metric) Test Method

Product Thickness 4.2 mils 0.106 mm PSTC-133

Adhesive Peel Strength 60 oz/in 17 N/25mm PSTC-101

Adhesive Sheer Strength >72 hrs >72 hrs PSTC-107

Tensile Strength 34 lb/in 153 N/25mm PSTC-131

Elongation 100% 100% PSTC-131

Service Temperature -94°F to 300°F -70°C to 149°C

Flame Spread/Smoke Developed 0/5 0/5 ASTM E 84

Product & Specification Approvals


• ASTM E84 (0/5 Flame/Smoke Rating)
• LEED Credit under USGBC Rating System - contributes to Environment Quality
Credit 4.1: Low Emitting Materials, Adhesive and Sealant
12

VentureClad
Plus® 1579GCW
• Available in natural aluminum (1579GCW), white (1579GCW-WM)
and embossed texture (1579GCW-E) with and without adhesive
• Flexible, strong, reinforced insulation cladding
• Vapour barrier and heavy duty all weather mechanical protection
• -94°F to 248°F (-70°C to 120°C) service temperature
• High puncture and tear resistance
• Used over all types of insulation materials including foil faced
fiberglass, faced mineral wool, faced calcium silicate,
faced perlite, urethane and polystyrene
• Passes ASTM C 1338 Fungi Resistance Testing; contains tested and
approved mold inhibiting agents MOLD

Technical Data (Typical values, not for specification purposes)


Specification Typical Value Typical Value (Metric) Test Method

Material Thickness 15 mils 0.38 mm PSTC-133

Adhesive Peel Strength 100 oz/in 27.7 N/25mm PSTC-101

Adhesive Shear Strength >72 hours >72 hours PSTC-107

Tensile Strength 140 lb/in 616 N/25 mm PSTC-131

Elongation 35% 35% PSTC-131

Puncture Resistance 68 lb 302 N ASTM D 1000

Tear Strength 16 lb 71.2 N ASTM D 624

Burst Strength - Inside/Outside 522 psi 3599 kPa ASTM D 774

Burst Strength - Outside/Inside 539 psi 3716 kPa ASTM D 774

Service Temperature -94°F to 248°F -70°C to 120°C

Flame Spread/Smoke Developed 10/10 10/10 ASTM E 84

Water Vapor Permeability 0.0000 perms 0.0000 perms ASTM E 96

Product & Specification Approvals


• ASTM E 84 (10/10 Flame/Smoke Rating)
• LEED Credit under USGBC Rating System - contributes to Environment Quality
Credit 4.1: Low emitting Materials, Adhesive and Sealant
• U.S. Patent #7,624,762 for 1579CW
• IMO Resolution A.653 (16)
• IMO Fire Test Procedures Code Annex 1, Part 5 and Annex 2
• IMO Resolution MSC 61 (67) Annex 1, Part 2 & 5 Annex 2
• Corps of Engineers Unified Specification
• Coast Guard 164.112/1121/WCL MED0315T1
• South African Building Standard (SABS) SANS 10177 Part 3, Class 1
• Japan Building Standard Law Article 2, Clause 9
• Netherlands CINI 3.3.12 Requirement
• Meets requirements of SOLAS
• Meets New York City MTA requirements for Insulation and Insulation Jacketing
13 13

VentureWrap
1555U
• Multi-ply laminate with an inner core of aluminum foil with
polyester films on both sides which prevents formation of pinholes
• Low temperature vapor barrier joint closure system in cryogenic
applications
• Works well on cold/chilled lines
• May be applied to all types of foam insulation
• Product must be covered by cladding material (i.e. VentureClad) on
all exterior applications

Technical Data (Typical values, not for specification purposes)


Specification Typical Value Typical Value (Metric) Test Method

Material Thickness 2.4 mils 0.06 mm PSTC-133

Tensile Strength 30 lb/in 136 N/25mm PSTC-131

Elongation 49% 49% PSTC-131

Puncture Resistance 16.7 lbs 75.7 N ASTM D 1000

Application Temperature Range -76°F to 302°F -60°C to 150°C

Minimum Continuous Use Temperature -30°F -34°C

Maximum Continuous Use Temperature 320°F 149°C

Flame Spread/Smoke Developed 10/20 10/20 ASTM E 84

Water Vapor Permeability 0.00 perms 0.00 perms ASTM E 96

Product & Specification Approvals


• ASTM E 84 (10/20 Flame/Smoke Rating)
• LEED Credit under USGBC Rating System - contributes to Environment Quality
Credit 4.1: Low Emitting Materials, Adhesive and Sealant
How is VentureClad®
Jacketing installed?
Surface Preparation

Ensure that all surfaces are dry and clean, free from dust, oil and grease/silicone. All insulation should be taped securely, giving an even
surface for the VentureClad application. All adhesives work best when firmly “wetted out” to the substrate surfaces.

When applying, partly peel back and crease the liner so enough adhesive is available to attach the VentureClad in the correct position.
Then, with a spreader, progressively remove the liner while smoothing, until the entire sheet has been applied.

When applying VentureClad sheet onto a continuous surface until it meets itself, a 3 inch (75mm) overlap is recommended to give a
strong, weatherproof seal. Plan the wrap so that the edge of the sealing flap faces down.

Application to Rectangular Ductwork 3 Application to Pipe/Circular Section


Duckwork
On ductwork over 32 inches (80cm) wide, it is
recommended that the top be crowned (pitched), to allow On straight pipe, cut VentureClad to the desired length (pipe
water runoff, preventing pooling. 2 2 circumference), plus an additional overlap
of 3 inches (75mm).
For fast, easy application,
VentureClad should be applied
to each of the sides
1 Apply the next piece allowing a
3 inch (75mm) overlap onto
separately, starting the previous section.
with the bottom
surface, then the sides,
and finally the top.

On bends and elbow configurations, pre-cover the pipe


insulation with VentureClad.

Cut out the required shapes to cover the segments Application to Ductwork Reducer
of the bends and elbows and apply.
Starting from the bottom, work upwards allowing an
overlap of 3 inches (75mm) onto adjacent surfaces.

First apply VentureClad to surface No.1, and overlap


onto each adjoining surface.
5
2 Apply VentureClad to surface No. 2, and overlap
3 onto surfaces no. 3, 4, and 5, sealing onto the
2 overlap and trimming flush at surface No. 1, to
3 4 achieve a neat, secure finish.
2 2 5
4 Apply VentureClad to surface No. 3 in the same manner
1 1 as to surface No. 2, but seal onto the overlap and trim at
4 surface No. 2.
On reduced pipe, apply
Finally, apply VentureClad to surfaces No. 4 and 5 as with other
VentureClad first to surface
rectangular ductwork.
No. 1, overlapping onto surface
No. 2. Cut shape No. 2, allowing for 3
inch (75mm) overlap, and apply to surface No.
2, overlapping onto section No. 1. On “tee” sections, make appropriately Overlap
configured templates of VentureClad,
Apply VentureClad to surface No. 3 leaving a 1 inch (25mm) overlap.
overlapping and sealing onto section No.2.

Finally, apply to surface No.4, overlapping and


sealing onto section No.1.

Repair of VentureClad NOTES:


Should damage occur, simply ensure that For installations using 1579CW, ALL seams must be taped with the
the surface is clean, and apply a new recommended VentureClad jointing/seaming tape.
section of VentureClad over the
damaged area, to a minimum All underlying foil faced insulation products must be sealed with VentureTape
of 3 inches (75mm) past the foil or FSK tape to maintain warranty conditions.
damage site.
Please contact your local Venture Tape representative for additional high traffic
area and indigenous wildlife installation instructions.
For more information, videos and complete product catalogue
visit www.3m-iatd.sg

For expertise on product applications and specifications,


contact us at innovation@sg.mmm.com
Product Use:
Many factors beyond 3M’s control and uniquely within user’s knowledge and control
can affect the use and performance of a 3M product in a particular application. Given
the variety of factors that can affect the use and performance of a 3M product, user is
solely responsible for evaluating the 3M product and determining whether it is fit for a
particular purpose and suitable for user’s method of application.

Warranty, Limited Remedy, and Disclaimer:


Unless an additional warranty is specifically stated on the applicable 3M product
packaging or product literature, 3M warrants that each 3M product meets the applicable
Industrial Adhesives and Tapes Division 3M product specification at the time 3M ships the product. 3M MAKES NO OTHER
3M Technologies (S) Pte Ltd WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING, BUT NOT
1 Yishun Avenue 7 LIMITED TO, ANY IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED WARRANTY OR CONDITION
Singapore 768923 ARISING OUT OF A COURSE OF DEALING, CUSTOM OR USAGE OF TRADE. If the 3M
product does not conform to this warranty, then the sole and exclusive remedy is, at 3M’s
option, replacement of the 3M product or refund of the purchase price.
Phone 65 6450 8888
Fax 65 6552 2119 Limitation of Liability:
Except where prohibited by law, 3M will not be liable for any loss or damage arising from
Email innovation@sg.mmm.com the 3M product, whether direct, indirect, special, incidental or consequential, regardless
Web www.3m-iatd.com.sg of the legal theory asserted, including warranty, contract, negligence or strict liability.

You might also like