Tec850 SpecSheet
Tec850 SpecSheet
Tec850 SpecSheet
Features
• Tec 850 agent specific vaporizers are designed to deliver
isoflurane and sevoflurane anesthetic agents
• Provides output consistent with the dial setting throughout
the clinical flow range
• Easy to turn dial and fine graduations help control agent
delivery
• Enhanced design with consistent, reliable operation over
the product life
• Tec 850 vaporizer supports a variety of contemporary
agent filling mechanisms
• Improved ergonomics and contemporary design
complements GE Healthcare’s anesthesia systems
• Attaches to GE Healthcare interlocking Selectatec™ manifold
• No planned factory service needed
• Five-year warranty period
gehealthcare.com
Clinical performance Physical specifications Environmental specifications
• Tec 850 Vaporizers are designed to provide consistent output
throughout the clinical flow range from 200 ml/min to 15 l/min. Dimensions Operation
Models are available for isoflurane and sevoflurane Height: 25 cm Temperature: 15°C to 35°C
• Tec 850 Vaporizers are equipped with a large diameter control Depth: 22 cm Humidity: 15% to 95% relative humidity
dial with graduations up to 5% V/V (isoflurane models) or 8% (non-condensing)
V/V (sevoflurane models) Width: 11 cm
Weight: 7 kg dry Ambient pressure: 500-800 mmHg
• The easy turning dials and small graduations on the Tec 850
Vaporizer help you fine tune anesthetic delivery over the full Agent capacity Storage and Transport
range of dial settings and flow rates Temperature: -25°C to 60°C
Total capacity: 300 ml
Capacity between min/max fill marks: 170 ml Humidity: 15% to 95% relative humidity
Enhanced ergonomics Wick system capacity: 75 ml approximately
(non-condensing)
• The ergonomic dial release on the Tec 850 Vaporizer allows Ambient pressure: 400-800 mmHg
either left or right hand operation
Service
• Wide, centered liquid level indicator provides a clear Pneumatics specifications Planned factory service free
indication of the fill level of the vaporizer
• Easy to turn dial with enhanced readability Calibration and flow resistance MRI Safety Information
Calibration: Calibration of all models is done at MR Conditional
21°C using O2 as carrier gas, 5 l/min
Lower overall ownership costs fresh gas flow, at sea-level ambient Agent filling systems
• The Tec 850 Vaporizer has no planned factory service, which pressure Isoflurane models: Easy-Fil™
helps lower the total cost of ownership and eliminate the Sevoflurane models: Easy-Fil, Quik-Fil™, SAFE-T-SEAL™, Piramal Fill
Isoflurane models: Control dial calibrated up to 5% V/V.
logistical challenges associated with the return of vaporizers Note: may not be available in all regions
to the factory. For complete user maintenance requirements, The control dial is marked in steps of
refer to the User Reference Manual 0.25% up to 1% and in steps of 0.5% Warranty
between 1% and 5%. Warranted to be free from functional defects in materials
• The Tec 850 Vaporizer comes with a five-year warranty
Easy-Fil helps simplify agent filling Sevoflurane models: Control dial calibrated up to 8% V/V. and workmanship for a period of five years from the date of
original delivery.
Control dial is marked in steps of
Reliability, convenience, and operating 0.25% up to 1% and in steps of
excellence 0.5% between 1% and 8%.
• Tec 850 is compatible with modern agent filling systems that Flow resistance: OFF: Isolated, no resistance
simplify filling and help minimize agent leaks while filling from vaporizer
• To minimize filling frequency, the Tec 850 Vaporizer can ON: 5 l/min O2: <20 cmH2O
hold up to 300 ml of anesthetic agent Accuracy
• The Tec 850 Vaporizer can be mounted on GE Healthcare Isoflurane models: ±0.25% of delivered agent or ±15%
anesthesia systems equipped with the Selectatec manifold of control dial setting (whichever
without tools and without taking the anesthesia system is greater)
out of service
Sevoflurane models: ±0.4% of delivered agent or ±15%
• The Tec 850 Vaporizer also interlocks in series with of control dial setting (whichever
GE Healthcare Tec 7 and Tec 6 Plus Vaporizers is greater)
• The non-spill system in the Tec 850 Vaporizer limits movement Fresh gas flow: 200 ml/min to 15 l/min
of liquid agent if the vaporizer is tilted or inverted, protecting
internal components and helping maintain output within
clinically acceptable limits Agent color coded Easy-Fil adapters
Imagination at work