Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

HB d1817 Ar 110 Roof Plan

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

LI NE

ARCHITECTURAL
R VE

RY L IN E/ ROAD R
E SE
TENDER
NDA
SI TE BOU
AMENDMENT
N BU
FFE
RL INE
NO. 7 DRAWING

3000
E
GRE
818A 3 .0 M
0
245

S IT
126
00
CONSTRUCTION

EB
7500

2.0M

OU
DRAWINGS

PLA

ND
818

IN E

A RY
RL

NTI
FFE
A D BU

NG
O
0M R

LIN
12.6
7 .5

STR

E
0M

IP
ROA
DB
819

UI L
DIN
GS
ETB
3a Y2

A CK
115 112

LIN
L H F D B A

E
N
44800
W E
KEY PLAN 12650 12650 7100 9950 2450

S SCALE 1: 1000

9550 9550 2150 C 03-2022 TENDER AMENDMENT 7 CC


B 02-2022 TENDER AMENDMENT 4 CC

350
1

250
A 02-2022 TENDER AMENDMENT 3 CC
REV DATE SUBJECT CHKD
4150 2650
REVISION NOTES
0.8m wide maintenance

5250

5250
catwalk below
stump for gondola

15°
to detail NOTE :
PRECAST PRECAST PRECAST PRECAST 1. Architectural dimension & levels are based on finished floor level.

6650
WATER TANK WATER TANK WATER TANK WATER TANK RC FLAT ROOF 2. Contractor to make allowance for Structural & Architectural levels & dimensions.
(WR/HR) (WR/HR) (WR/HR) (WR/HR) OVER ST-1 horizontal safety lifeline and 3. Shop drawings to be provided for Architect's approval.

9150
(4 RINGS) (4 RINGS) (4 RINGS) (4 RINGS) (NO ACCESS MOBILE DEPLOYMENT safety hooks to specialist's detail 4. All dimensions to be verified and discrepancies shall be reported to the Architect immediately.
EXCEPT FOR SPACE (MDS) 5. Main Contractor to comply with PE requirements for all glass under their own cost.
MAINTENANCE (BELOW AT MAIN ROOF)
1625 ONLY)
rc flat roof with complete
waterproofing membrane TENDER: D 1817

3700
(Cement Screed) system to details
RC sunshade

4250
FFL 148.875
DC SUBMISSION: HB-DL-D1817

FALL
1:50
rc flat roof with complete 0.2m high rc kerb
waterproofing membrane RC FLAT ROOF OVER WR/HR
system to details 1:50 PUMP SPACE 0.2m high rc kerb
FALL (NO ACCESS EXCEPT FOR
maintenance cat ladder to engr's details MAINTENANCE ONLY)
(Cement Screed) RC sunshade
6
horizontal safety lifeline and KALLANG WHAMPOA C36

1550
FFL 148.875 safety hooks to specialist's detail
RC sunshade RC FLAT ROOF OVER
0.2m high rc kerb
DOMESTIC WATER PUMP SPACE
(NO ACCESS EXCEPT FOR 7
PRECAST
MAINTENANCE ONLY) rc flat roof with complete
waterproofing membrane
OWNER

24200
WATER TANK (Cement Screed)
stump for gondola to detail system to details
(DOMESTIC)

FALL
1:50
FFL 148.875
(4 RINGS)
horizontal safety lifeline horizontal safety lifeline
and safety hooks to 2.
HOUSING &
and safety hooks to
specialist's detail DEVELOPMENT

4500
specialist's detail 114
BOARD
0.2m high rc kerb horizontal safety lifeline and

9150
safety hooks to specialist's
detail PRECAST PRECAST PRECAST PRECAST PRECAST X2
STAIR 3
rc flat roof with complete
waterproofing membrane RC FLAT ROOF OVER LIFT MOTOR WATER TANK WATER TANK WATER TANK WATER TANK WATER TANK HDB HUB 480 LORONG 6 TOA PAYOH SINGAPORE 310480
111

9450
ROOF
ACCESSI (NOT system to details ROOM (NO ACCESS EXCEPT FOR (DOMESTIC) (DOMESTIC) (DOMESTIC) (DOMESTIC) (DOMESTIC)
BLE) MAINTENANCE ONLY) 3650 (4 RINGS) (4 RINGS) (4 RINGS) (4 RINGS) (4 RINGS)
(Cement Screed)
PROJECT

5250
stump for gondola to detail

FALL

FALL
1:50

1:50
34TH S
TOREY
SK Y TERR
A CE
KALLANG WHAMPOA CONTRACT
horizontal safety lifeline
and safety hooks to
specialist's detail
stump for gondola to detail

12
36 - PROPOSED PUBLIC HOUSING
0.2m high rc kerb 9550 9550 DEVELOPMENT COMPRISING A

2850
BLOCK OF 33/47 STOREY

2500
horizontal safety lifeline and safety
15°
hooks to specialist's detail
13
RESIDENTIAL BUILDING WITH SKY
TERRACE AT 22ND AND 34TH

1500
RC sunshade to refer to detail

14 STOREY [TOTAL 398 UNITS], 1


12650 12650
BLOCK OF MULTI-STOREY
25300 CARPARK WITH ROOF TERRACE &
G E
ESS AND A PAVILION ON LOTS
1a 2181C PT, 98934X PT, 2853P PT,
113
2852V PT, 2278N PT, 98933N PT,
98936C PT, 2176X PT, 1517W PT,
707W PT, 2632A PT, 706M, 704L,
7.50

705C TS 17 AT KING GEORGE’S


MR

AVENUE / SYED ALWI ROAD


3/0M

OAD

NE
BA C
K LI (KALLANG PLANNING AREA)
GRE

BUF

SE T
I NG
UILD
F
EN

B
ER

OAD
0M R
B UF

1 2 .6
LIN
FER

LOT NO.: TS NO.:


LIN
E

750
0 2181C PT, 98934X PT, 2853P PT, 17
2852V PT, 2278N PT, 98933N PT,
0 98936C PT, 2176X PT, 1517W PT,
300
707W PT, 2632A PT, 706M, 704L,
705C
SITE
BOU

1260
NDA

0
RY L

DRAWING TITLE
IP
I

R
NE /

G ST BLOCK (818A) - ROOF PLAN (UPPER)


A NTIN
PL
IDE
R

0M W
OAD

2. 1260
0
1 2 .6
RES

L IN E 2000
0M R

ARY
2000

OUND
E

B 6000
SITE
RVE

OAD

ARCHITECT'S ADDRESS
2 .0 M

BLOCK (818A) - ROOF (UPPER)


6 .0 M
L

B
INE

UILD
W ID
SITE

0m
MSC

1.5m 7.5m 15m


E PL

NG I
BOU

ARCHITECTURE
S ET

SE
AN T

JGP ARCHITECTURE (S) PTE LTD 16 UPPER CIRCULAR ROAD SINGAPORE 058414
NDA

TBA

TEL : 63399000 FAX : 63395005 EMAIL : SIN@JGP-GROUP.COM HTTP://WWW.JGP-GROUP.COM


B AC
ING

SCALE 1: 150
RY

DRAWN CHECKED APPROVED


K LI

K LI
STR
L IN E

BY BY BY
JEFF CC PC
NE

NE
IP

NOTE : SCALE As indicated DATE MAR 2022


1. THE CONTRACTOR MUST CHECK ALL DIMENSIONS ON SITE. ANY DISCREPANCIES IN THE
FIGURED DIMENSIONS ARE TO BE REPORTED IMMEDIATELY TO THE ARCHITECT OR DWG NO. HB-D1817-AR- 110
ENGINEER. DO NOT SCALE-OFF MEASUREMENT FROM DRAWINGS.
REV NO. C
2. WHILE EVERY CARE HAS BEEN EXERCISED IN HIGHLIGHTING THE AMENDMENTS VIA
"CLOUDING", CONSULTANTS DOES NOT WARRANT THE ACCURANCY AND COMPLETENESS G:\JG17A448 (Kallang Whampoa C36)\
OF SUCH HIGHLIGHTING. FILENAME CD\0-Tender\MAIN\100 SERIES
JOB NO. JG17A448
3. THE CONTRACTOR SHALL VERIFY AND SATISFY HIMSELF THAT THE LATEST AMENDMENTS
ARE USED FOR CONSTRUCTION IN ACCORDANCE TO THE LATEST DRAWINGS. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE. ANY DISCREPANCIES TO BE
4. THIS DRAWING SHALL NOT BE USED OTHER THAN FOR ITS INTENDED PRUPOSE AS REPORTED TO THE ARCHITECT IMMEDIATELY. THIS DRAWING IS TO BE READ IN
CONJUNCTION WITH STRUCTURAL DRAWINGS. THIS DRAWING IS COPYRIGHT.
STATED HEREIN.

You might also like