Date DRN by CHKD by Apprd by Scale 29-12-23
Date DRN by CHKD by Apprd by Scale 29-12-23
Date DRN by CHKD by Apprd by Scale 29-12-23
BEFORE CASTING THE FOUNDATION VERIFY THE DIMENSIONS OF THE WIND SPEED (M/SEC) 44
FOUNDATION BOLT (DIA.& QTY.) AND ANCHOR PLATE (PCD) WITH BENDING MOMENT (T-M) 116.028
RESPECT TO THE DIMENSIONS MENTIONED IN THIS DRG. HORIZONTAL SHEAR (T) 4.815
VERTICAL LOAD (T) 7.955
MAX GR BEARING
PRESSURE (T/M2) 14.620
1900 88 nos 12 tor (T1) SAFETY FACTOR AGAINST
OVERTURNING 1.008
CONCRETE MIX VIBRATED M-25
MIN COVER (MM) 50
1900
1900
Nos.of hole/Dia.(mm) = 24 / 41
SECTIONAL ELEVATION
PCC (1:4:8)
100
2375
SECTIONAL ELEVATION T1 88 12 2795
4300 320
100
T2 96 10 4400
4200
1800
24 nos.
1800
Bolts T3 14 8 7392
4300
100
T4 42 10 4400
4200
QUANTITIES
21 nos 10 tor Bothways (T4) RCC PCC STEEL
48 nos 10 tor Bothways (T2) (M3) (M3) (kg)
Page 1