Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Date DRN by CHKD by Apprd by Scale 29-12-23

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

FOUNDATION LOADINGS

BEFORE CASTING THE FOUNDATION VERIFY THE DIMENSIONS OF THE WIND SPEED (M/SEC) 44
FOUNDATION BOLT (DIA.& QTY.) AND ANCHOR PLATE (PCD) WITH BENDING MOMENT (T-M) 81.611
RESPECT TO THE DIMENSIONS MENTIONED IN THIS DRG. HORIZONTAL SHEAR (T) 3.950
VERTICAL LOAD (T) 2.986
MAX GR BEARING
PRESSURE (T/M2) 15.040
1600 64 nos 12 tor (T1) SAFETY FACTOR AGAINST
OVERTURNING 0.757
CONCRETE MIX VIBRATED M-25
MIN COVER (MM) 50
1600

8 tor 190 c/c (T3) STEEL Fe-415


GROSS SBC (T/M2) 10.00
Bolt Nos. = 24 PROJECTED AREA (M2) 11.780
Bolt Dia. = 30 mm
DETAIL OF PEDESTAL Length = 850 mm

1600

150 Anchor Pl. Thk.(mm) = 8 mm


PCD (mm) = 1160 mm
300

Nos.of hole/Dia.(mm) = 24 / 32

64 nos 12 tor (T1)


1700

8 tor 190 c/c (T3)


2100

19 nos 10 tor Bothways (T4)


300

SECTIONAL ELEVATION
PCC (1:4:8)
100

BAR BENDING SCHEDULE


100 3700 100 MK QTY SIZE LENGTH SHAPE
46 nos 10 tor Bothways (T2) 100

2175
SECTIONAL ELEVATION T1 64 12 2595

3700 320

100
T2 92 10 3800
3600
1500
24 nos.

1500
Bolts T3 12 8 6192
3700

100
T4 38 10 3800
3600
QUANTITIES
19 nos 10 tor Bothways (T4) RCC PCC STEEL
46 nos 10 tor Bothways (T2) (M3) (M3) (kg)

9.23 1.52 508.584


19 nos 10 tor Bothways (T4)
46 nos 10 tor Bothways (T2) NOTES
1- ALL DIMENSIONS ARE IN MM. DO NOT SCALE THE DRAWING
SECTIONAL PLAN 2- MIN. LAP LENGTH OF BARS SHALL BE 50xD. UNLESS OTHERWISE STATED.
3- WE RECOMMANDED THAT MAST FLANGE REMAIN UNGROUTED
4- IF GROUTING IS CARRIED OUT IT IS ESSENTIAL TO LEAVE A MINIMUM
OF 4 NOS 25MM DIA DUCTS EQUALLY SPACED AROUND THE FLANGE TO
ALLOW DRAINGE AND VENTILATION
REV DESCRIPTION DATE 5- BARS DRAWN IN THE DRAWING ARE FOR ILLUSTRATION ONLY. REFER TO
THE NUMBERS SHOWN FOR ACTUAL REINFORCEMENT QUANTITY.
This drawing is the property of "VMMPL" & must be returned on
request. It is submitted as confidential information in connection with enquiry, tender,
orders or contracts. It is not to be used for any other purpose or order nor may it re-
copied or lent without our authority in writing
DATE 29-12-23 TITLE: GA Civil Foundation Drawing for 32m Sheet No. Rev.
DRN BY AUTO High Mast 01 of 01 0
CHKD BY GK PROJECT: M/s-CIDCO DRAWING NUMBER: -
APPRD BY AU HM DESIGN CALCULATIONS
SCALE NTS

Page 1

You might also like