Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (0 votes)
30 views

Ws 120

The document provides a user manual for the WS-120 Wall Scanner. It describes the device's applications for detecting metals and live wires behind walls. It lists the technical specifications, including a maximum scanning depth of 110mm for metals and 50mm for live wires. It provides instructions for operating the different modes, turning it on/off, and maintaining the device. Cautions are provided regarding safety and use in various environments. The manual is subject to change without notice.

Uploaded by

patronski mitar
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views

Ws 120

The document provides a user manual for the WS-120 Wall Scanner. It describes the device's applications for detecting metals and live wires behind walls. It lists the technical specifications, including a maximum scanning depth of 110mm for metals and 50mm for live wires. It provides instructions for operating the different modes, turning it on/off, and maintaining the device. Cautions are provided regarding safety and use in various environments. The manual is subject to change without notice.

Uploaded by

patronski mitar
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

WS-120 Wall Scanner Icons and Descriptions Operations

A: Sensing aperture, mark hole B: Result display


User Manual
C: Live wire mode D: Auto mode
Note: please read this manual carefully before using the detector and E: Metal/nonmetal mode F: ON/OFF
observe safety rules and cautions in the manual; the manual shall be G: Backlight/alarm ON/OFF H: Nonskid mat
subject to change without prior notice. I: Detecting area J: Sensing window

K: Battery case
Applications
Figure 1 Figure 2 Figure 3
WS-120 is a handhold wall scanner for quick detection of magnetic metals

in wall, rooftop and floor, such as reinforcing steels, iron pipes, and Always put the detector close to the wall surface and slowly move as figure

nonmagnetic metals such as aluminum pipes, copper pipes, and nonmetal 1, sensing aperture (A) turns green and the system enters standby status;

materials such as beams, PVC water pipes, as well as electrified objects when any object is detected, scale bar (1) shall be gradually full and

such as live wires. sensing aperture (A) turns red and alarm, see figure 2 for sensing scale. If

you want to find the central position, please move the detector left and right

Technical Data over the hided object repeatedly and observe the scale point (2) (changes

Maximum scanning depth of the scale bar and point), when the scale bar is full and central point is

Ferrous metal: 110 mm displayed as figure 3, it means the central position is got.

Non-ferrous metals: 110 mm

Copper conductors (Live): 50 mm 1. ON/OFF

Wood: 25 mm LCD Display Short press to turn on the detector and long press for 3s to turn it off;
Working temperature: -10℃~+50℃ After turning on, the detector initiates automatically and the scale bar

Storage temperature: -20℃~+70℃ displays in full and then disappears, it enters standby status; when no any

Humidity: ≤75% Altitude: ≤2000m operation on the detector in 3 minutes, the detector shall turn off

Battery: 3*1.5V AAA automatically.

Dimensions: 185*85*33mm 2. AUTO Mode

Weight: 180g The detection mode is defaulted as auto after its turn-on, you may switch to

1:Scale bar: 2:Scale point: auto mode by key in other mode;

sensing strength of search central position of the searched object If more than one object are detected in auto mode, the icons displaying

sequence is live → metal → magnetic → nonmagnetic → nonmetal


4:Magnetic metal or
3:Auto searching mode
3. metal mode
nonmagnetic metal

5:Metal or nonmetal 6:Live wire Short press key to enter metal mode (for magnetic/nonmagnetic
metals)
7:Error 8:Battery level

9:Alarm mute Long press key to enter nonmetal mode (for wood and PVC pipes)

Downloaded from www.Manualslib.com manuals search engine


4. AC Wire Cautions

Press key to switch to AC detection mode 1) Before turning on the detector, please ensure no water on the area to Maintenance

Only AC wires (>110V, 50~60Hz) can be detected be detected, use cloth to wipe up if necessary, don’t let any wet get inside 1)Keep the detector clean and dry all the time to ensure accurate detection

Only solid wires can be detected, not for twisted pairs the device, keep it away from the direct sunshine; and safe operation;

5. Turn On/Off Alarm Tone 2)Don’t use the detector in extreme weather, if there is great difference in 2)Don’t put the detector into water or other liquids, use dry and soft cloth to

Short press key to turn on/off alarm tone; temperature; Don’t use the detector until its temperature is close to the wipe up, any detergent or solvent is not allowed;

Turn on/off backlight environment; 3) Don’t stick any label or mark on the detecting areas, front and back,

Long press key to turn on/off the screen backlight (press and hold 3)Keep away from electric tools or transmitting devices such as WLAN, especially metal nameplate;

the key for 3s) UMTS, flying radar, launching tower, microwave oven and other devices of 4)Don’t remove the nonskid mat on the back side.

6. Battery Installation and Replacement such property;

Screw off the fastening screws and open the battery cover upwards, install 4)Take out the batteries when not used, to prevent battery leakage and Warranty

3 AAA batteries (alkaline) inside, please note the polarities. corrosion; 1)If the detector is unable to turn on or work in normal, please return it in

Battery level: 5)Precision and depth might be weakened by environment factors such as attached protective jacket to the dealer or factory for repair service;

Full wall constitutions (metal building materials, current conducting wallpapers, 2) Any damage arising from dismantlement without permit, improper

2/3 full or less ceramic tiles or sound absorbing materials), big water content, and quantity, keeping or wrong operation, and the conditions of warranty paper alteration

1/3 full or less sort, size and position of the object(s), all of them shall affect the detection. or no sales paper, shall be out of the warranty;

Replace with new Hence it’s advised to take necessary protective measures according to 3)
Please observe the above provisions and we shall offer one-year product

7. Calibration other notices before boring or cutting the wall; warranty.

When you move the detector close to an area without metal objects, but 6)Keep the sensing window (J) clean, it fails to sense whether it’s close to

you can that the scale bar is full and with alarm, that probably it’s the wall surface if it’s dirty or covered;

interrupted by the environment, in that case, please calibrate the detector 7)It is easier to detect the live wire if it has been connected to working load

by manual and restore it to factory setting. (such as lamp or electric appliance). It’s hard to detect the live wires laid

a) Firstly don’t put the detector close to the wall surface, just hold it in an inside some walls that can isolate the current;

open air, no touching or covering on the detecting area (I). 8)Static electricity might cause inaccurate detection, in order to improve

b) Short press key in auto mode, and key in metal mode, if the detection, you may put your other hand flatly close on the wall surface

you see that the scale bar becomes full and then disappears, entering beside the detector to eliminate the static electricity;

standby status, it indicates the calibration is completed. 9)You may mark the position where the object is found; If the object’s edge

c) Error might also happen if the battery is not enough, 1/3 battery level or central point is detected, mark the above position at the mark hole (A);

is required at least. 10) The detector is designed with temperature monitor unit. Constant

temperature inside the detector can ensure accurate detection; if alarm

icon 11) is displayed, it indicates the temperature is out of working range

or there is great difference in temperature; Turn off the detector and let it

restore normal temperature, and then turn it on again.