Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (0 votes)
28 views2 pages

Thermo Scientific Model 43i-HL High Level SO Analyzer: Pulsed Fluorescence Gas Analyzer For Source Emissions Monitoring

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 2

Pulsed fluorescence gas analyzer

Product Specifications
for source emissions monitoring

Thermo Scientific
Model 43i-HL
High Level SO2 Analyzer

Key Features The Thermo Scientific Model 43i-HL High Ethernet connectivity provides efficient
Level SO2 Analyzer utilizes pulsed remote access, allowing the user to
• Ethernet connectivity for efficient florescence technology to measure the download measurement information
remote access amount of sulfur dioxide in the air. directly from the instrument without
Measuring sub ppm levels up to 1,000 having to be on-site. A flash memory
• Enhanced user interface with one ppm in standard range mode, and from offers increased data storage and user
button programming and large 100 ppm up to 10,000 ppm in extended downloadable software.
display screen range.
Easily programmable short-cut keys
• Flash memory for increased data Dual range and auto range are standard allow you to jump directly to frequently
storage and user downloadable features in this instrument as well as accessed functions, menus or screens
software temperature and pressure correction. The larger interface screen can display
Alarm levels are user settable for measurement information and status,
• Enhanced electronics design concentration. A wide variety of internal while the primary screen remains visible.
optimizes product commonality diagnostics are available from an easy to
follow menu structure.
• Improved layout for easier
accessibility to components
Product Specifications

To maintain optimal product performance, you need immediate access to experts worldwide, as well as priority status when your air quality
equipment needs repair or replacement. We offer comprehensive, flexible support solutions for all phases of the product life cycle. Through
predictable, fixed-cost pricing, our services help protect the return on investment and total cost of ownership of your Thermo Scientific air quality
products.

Thermo Scientific Model 43i-HL High Level SO2 Analyzer

Standard Ranges 0-10, 20, 50, 100, 200, 500 and 1000 ppm
0-20, 50, 100, 200, 500, 1000 and 2000 mg/m3
Extended Ranges 0-100, 200, 500, 1000, 2000, 5000 and 10000 ppm
0-200, 500, 1000, 2000, 5000, 10000 and 20000 mg/m3
Custom Ranges 0-10 to 1000 ppm (standard), 0-100 to 10,000 ppm (extended)
0-20 to 2000 mg/m3 (standard), 0-200 to 20,000 mg/m3 (extended)
Zero Noise 0.25 ppm (300 second averaging time)
Lower Detectable Limit 0.5 ppm (300 second averaging time)
Zero Drift (24 hour) less than 1 ppm per day
Span Drift (24 hour) +/- 1% full scale
Response Time 80 sec (10 second averaging time)
Linearity +/- 1% full scale
Sample Flow Rate 0.6 to 1.0 liters/min.
Interferences < lower detectable limit except for the following:
(EPA levels) NO: < 3 ppb, tested at 500 ppb, M-Xylene < 1 ppb, tested at 200 ppb,
H2O < 2% of reading, tested at 2% H2O absolute
Operational Temperature Performance specifications based on operation within 20°-30° C range. Instrument may be safely operated
over the range of 0°-45° C
Power Requirements 100 VAC, 115 VAC, 220-240 VAC +/-10% @ 165W
Size and Weight 16.75” (425mm) W x 8.62” (219mm) H x 23” (584mm) D. 55 lbs. (25 kg)
Outputs Selectable Voltage, RS232/RS485, TCP/IP, 10 Status Relays, and Power Fail Indication (standard).
0-20 or 4-20 mA Isolated Current Output (optional)
Inputs 16 Digital Inputs (standard), 8 0-10Vdc Analog Inputs (optional)

Ordering Information

Model 43i-HL SO2 Analyzer 3. Optional I/O:


Choose from the following configurations/options A = None (standard)
to customize your own Model 43i-HL C = 0-20, 4-20mA current output - 6 channels,
0-10v analog input - 8 channel
1. Voltage options:
A = 120 VAC50/60 Hz (standard) 4. Mounting Hardware:
B = 220 VAC 50/60 Hz A = Bench mounting (standard)
J = 100 VAC 50/60 Hz B = Ears & handles, EIA
C = Ears & handles, retrofit
2. Internal zero / span and/or Oxygen Sensor:
N = No zero / span assembly (standard)
Z = Internal zero / span assembly
H = Heated kicker (no zero span)
Y = Heated kicker w/ internal zero/span assembly
S = Oxygen Sensor with No Zero/Span
R = Oxygen Sensor with Zero/Span Your Order Code: 43i HL-__ __ __ __
T = Oxygen Sensor with Heated Kicker, No Zero/Span
K = Oxygen Sensor with Heated Kicker and Zero/Span
Lit_43iHLAQI_10/10

© 2010 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries.
This specification sheet is for informational purposes only and is subject to change without notice. Thermo Fisher Scientific makes no warranties, expressed or implied, in this product summary.
Not all products are available in all countries. Please consult your local sales representative for details.

This product is manufactured in a plant whose quality management system is ISO 9001 certified.

Air Quality Instruments 27 Forge Parkway (866) 282-0430 www.thermoscientific.com/AQI


Franklin, MA 02038 USA (508) 520-0430
(508) 520-1460 fax