IECEx SIR 06.0045X Issue 4 (IS-mini Range)
IECEx SIR 06.0045X Issue 4 (IS-mini Range)
IECEx SIR 06.0045X Issue 4 (IS-mini Range)
of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification System for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com
Equipment: IS-mA1 Sounder, IS-mA2 Sounder, IS-mA3 Sounder, IS-mB1 Beacon, IS-mC1 Combined Sounder/Beacon and
IS-mA1M Sounder.
Optional accessory:
Signature:
(for printed version)
Date:
Additional
manufacturing
locations:
This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the
IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and
found to comply with the IECEx Quality system requirements.This certificate is granted subject to the conditions as set out in IECEx Scheme
Rules, IECEx 02 and Operational Documents as amended
STANDARDS :
The equipment and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found
to comply with the following standards
IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
Edition:6.0
IEC Explosive atmospheres – Part 26: Equipment with Equipment Protection Level (EPL) Ga
60079-26:2014-10
Edition:3.0
This Certificate does not indicate compliance with safety and performance requirements
other than those expressly included in the Standards listed above.
Test Reports:
GB/SIR/ExTR06.0103/00 GB/SIR/ExTR09.0189/00 GB/SIR/ExTR15.0024/00
GB/SIR/ExTR19.0311/00 GB/SIR/ExTR21.0052/00
EQUIPMENT:
Equipment and systems covered by this Certificate are as follows:
The IS-mA2 Sounder is similar to the IS-mA1 Sounder, the differences being a different printed circuit board layout and a ‘low
profile’enclosure base.
The IS-mA3 Sounder is similar to the IS-mA1 Sounder, the differences being the addition of several components to the circuit, a different
connection arrangement, a different printed circuit board layout and a ‘low profile’ enclosure base.
The IS-mC1 Combined Sounder/Beacon is designed to provide an audible and a flashing warning when activated.
For a fuller description and associated safety prameters, see the Annexe of this certificate.
Annex:
DESCRIPTION OF APPARATUS
The IS-mA1 Sounder is designed to provide an audible warning when activated. It consists of the following
mounted in an IP 65, flame retardant, ABS enclosure:
• Sounder printed circuit board assembly • Inductive sounder transducer
External connections are made to terminals mounted on the sounder printed circuit board via cable entry devices
mounted in the wall of the enclosure.
The parameters for the IS-mA1 Sounder are as follows:
Terminals Parameters
Ui Ii Pi Ci Li
Terminal + w.r.t. Terminal - 28 V 93 mA 660 mW 0 0
Terminals S2 and S3 w.r.t. Terminal - 28 V 0 - - -
The IS-mA2 Sounder is similar to the IS-mA1 Sounder, the differences being a different printed circuit board
layout and a ‘low profile’ enclosure base. Cable entry is via a ‘knockout’ in the bottom of the enclosure base,
this enclosure base, and thus the sounder, being designed for attachment to other equipment.
The parameters for the IS-mA2 Sounder are as follows:
Terminals Parameters
Ui Ii Pi Ci Li
Terminal + w.r.t. Terminal - 28 V 93 mA 660 mW 0 0
Terminals S2 and S3 w.r.t. Terminal - 28 V 0 - - -
The IS-mA3 Sounder is similar to the IS-mA1 Sounder, the differences being the addition of several
components to the circuit, a different connection arrangement, a different printed circuit board layout and a ‘low
profile’ enclosure base. Cable entry is via a ‘knockout’ in the bottom of the enclosure base, this enclosure base,
and thus the sounder, being designed for attachment to other equipment.
The parameters for the IS-mA3 Sounder are as follows:
Terminals Parameters
Ui Ii Pi Ci Li
Terminal + w.r.t. Terminals S2 and S3 28 V 93 mA 660 mW 0 0
The IS-mB1 Beacon is designed to provide a flashing warning when activated. It consists the following mounted
inside an IP 65, flame retardant, ABS enclosure that is fitted with a transparent polycarbonate ‘lens’:
• Beacon main printed circuit board assembly • Beacon LED printed circuit board assembly
External connections are made to terminals mounted on the beacon main printed circuit board via cable entry devices
mounted in the walls of the enclosure.
The parameters for the IS-mB1 Beacon are as follows:
Terminals Parameters
Ui Ii Pi Ci Li
Terminal + w.r.t. Terminal - 28 V 660mA 1.2 W 0 0
The IS-mC1 Combined Sounder/Beacon is designed to provide an audible and a flashing warning when
activated. It consists of the following mounted inside an IP 65, flame retardant, ABS enclosure that is fitted
with a transparent polycarbonate ‘lens’:
• Sounder printed circuit board assembly • Beacon main printed circuit board assembly
• Inductive sounder transducer • Beacon LED printed circuit board assembly
External connections are made to terminals mounted on the sounder printed circuit board assembly and the
beacon main printed circuit board assembly via cable entry devices mounted in the walls of the enclosure. The
IS-mC1 Combined Sounder/Beacon may be supplied with internal wiring connections between Sounder
Terminals +/- and Beacon Terminals +/-, alternatively these connections may be fitted by the user/installer.
The parameters for the IS-mC1 Combined Sounder/Beacon are as follows:
Terminals Parameters
Ui Ii Pi Ci Li
Without Sounder Terminal + w.r.t. Sounder Terminal - 28 V 93 mA 660 mW 0 0
internal Sounder Terminals S2 & S3 w.r.t. Sounder Terminal - 28 V 0 - - -
connections: Beacon Terminal + w.r.t. Beacon Terminal - 28V 660 mA 1.2 W 0 0
With internal Sounder Terminal + w.r.t. Sounder Terminal - 28 V 93 mA 660 mW 0 0
connections Sounder Terminals S2 & S3 w.r.t. Sounder Terminal - 28 V 0 - - -
The IS-mA1M Sounder is EPL Ma version of the IS-mA1 Sounder. The parameters of IS-mA1M Sounder are
as follows:
Terminals Parameters
Ui Ii Pi Ci Li
Terminal + w.r.t. Terminal – 28 V 93 mA 660 mW 0 0
Terminals S2 and S3 w.r.t. Terminal – 28 V 0 - - -
SPECIFIC CONDITIONS OF USE
IS-mA1 Sounder
• The equipment has an ingress protection rating of IP65. However, if it has been supplied without cable
entry devices, then the user shall ensure that the devices that are fitted will provide an ingress protection
that is appropriate to the environment in which it is installed i.e. IP20 or better. If only one of the two cable
entries are used, then the unused entry ‘knockout’ shall be left intact or fitted with a blanking device that
ensures ingress protection appropriate to the environment in which it is installed i.e. IP20 or better.
• The total capacitance connected to Terminal + w.r.t. Terminal – (i.e. the capacitance of the cable plus any
other capacitance) shall not exceed 83 nF.
• The equipment shall only be supplied via Terminal + w.r.t. Terminal – from a barrier having a maximum
open circuit voltage Uo that is ≤28 V and a maximum short-circuit current Io that is ≤93 mA, where Io is
resistively limited.
• The enclosure is non-conducting and may generate an ignition-capable level of electrostatic charges under
certain extreme conditions. The user should ensure that the equipment is not installed in a location where it
may be subjected to external conditions that might cause a build-up of electrostatic charges on non-
conducting surfaces, additionally, cleaning of the equipment should be done only with a damp cloth.
IS-mA2 Sounder
• The equipment has an ingress protection rating of IP65. However, as cable entry is via a ‘knockout’ in the
bottom of the enclosure base, the user shall ensure that this enclosure base is sealed to whatever it is
attached by a method that provides ingress protection appropriate to the environment in which it is installed
i.e. IP20 or better. An ‘O’ ring fitted within the outer rim of the bottom of the enclosure base may be used
for this purpose.
• The total capacitance connected to Terminal + w.r.t. Terminal – (i.e. the capacitance of the cable plus any
other capacitance) shall not exceed 83 nF.
• The equipment shall only be supplied via Terminal + w.r.t. Terminal – from a barrier having a maximum
open circuit voltage Uo that is ≤28 V and a maximum short-circuit current Io that is ≤93 mA, where Io is
resistively limited.
• The enclosure is non-conducting and may generate an ignition-capable level of electrostatic charges under
certain extreme conditions. The user should ensure that the equipment is not installed in a location where it
may be subjected to external conditions that might cause a build-up of electrostatic charges on non-
conducting surfaces, additionally, cleaning of the equipment should be done only with a damp cloth.
IS-mA3 Sounder
• The equipment has an ingress protection rating of IP65. However, as cable entry is via a ‘knockout’ in the
bottom of the enclosure base, the user shall ensure that this enclosure base is sealed to whatever it is
attached by a method that provides ingress protection appropriate to the environment in which it is installed
i.e. IP20 or better. An ‘O’ ring fitted within the outer rim of the bottom of the enclosure base may be used
for this purpose.
• The total capacitance connected to Terminal + w.r.t. Terminal S2 and S3 (i.e. the capacitance of the cable
plus any other capacitance) shall not exceed 83 nF.
• The equipment shall only be supplied via Terminal + w.r.t. Terminals S2 and S3 from a barrier having a
maximum open circuit voltage Uo that is ≤28 V and a maximum short-circuit current Io that is ≤93 mA,
where Io is resistively limited.
• The enclosure is non-conducting and may generate an ignition-capable level of electrostatic charges under
certain extreme conditions. The user should ensure that the equipment is not installed in a location where it
may be subjected to external conditions that might cause a build-up of electrostatic charges on non-
conducting surfaces, additionally, cleaning of the equipment should be done only with a damp cloth.
IS-mB1 Beacon
• The equipment has an ingress protection rating of IP65. However, if it has been supplied without cable
entry devices, then the user shall ensure that the devices that are fitted will provide an ingress protection
that is appropriate to the environment in which it is installed i.e. IP20 or better. If only one of the two cable
entries are used, then the unused entry ‘knockout’ shall be left intact or fitted with a blanking device that
ensures ingress protection appropriate to the environment in which it is installed i.e. IP20 or better.
• The enclosure is non-conducting and may generate an ignition-capable level of electrostatic charges under
certain extreme conditions. The user should ensure that the equipment is not installed in a location where it
may be subjected to external conditions that might cause a build-up of electrostatic charges on non-
conducting surfaces, additionally, cleaning of the equipment should be done only with a damp cloth.
IS-mC1 Combined Sounder/Beacon
• The equipment has an ingress protection rating of IP65. However, if it has been supplied without cable
entry devices, then the user shall ensure that the devices that are fitted will provide an ingress protection
that is appropriate to the environment in which it is installed i.e. IP20 or better. If only one of the two cable
entries are used, then the unused entry ‘knockout’ shall be left intact or fitted with a blanking device that
ensures ingress protection appropriate to the environment in which it is installed i.e. IP20 or better.
• The total capacitance connected to Sounder Terminal + w.r.t. Terminal – (i.e. the capacitance of the cable
plus any other capacitance) shall not exceed 83 nF.
• The equipment shall only be supplied via Sounder Terminal + w.r.t. Sounder Terminal – from a barrier
having a maximum open circuit voltage Uo that is ≤28 V and a maximum short-circuit current Io that is
≤93 mA, where Io is resistively limited.
• If not already fitted, optional internal wiring connections between Sounder Terminals + / - and Beacon
Terminals + / - may be fitted by the user. The wiring used for such connections shall have a minimum radial
thickness of insulation of 0.5 mm.
• The enclosure is non-conducting and may generate an ignition-capable level of electrostatic charges under
certain extreme conditions. The user should ensure that the equipment is not installed in a location where it
may be subjected to external conditions that might cause a build-up of electrostatic charges on non-
conducting surfaces, additionally, cleaning of the equipment should be done only with a damp cloth.
IS-mA1M Sounder
• The equipment has an ingress protection rating of IP65. However, if it has been supplied without cable
entry devices, then the user shall ensure that the devices that are fitted will provide an ingress protection
that is appropriate to the environment in which it is installed i.e. IP20 or better. If only one of the two
cable entries are used, then the unused entry ‘knockout’ shall be left intact or fitted with a blanking device
that ensures ingress protection appropriate to the environment in which it is installed i.e. IP20 or better
• The total capacitance connected to Terminal + w.r.t. – (i.e. the capacitance of the cable plus any other
capacitance) shall not exceed 83 nF.
• The enclosure is non-conducting and may generate an ignition-capable level of electrostatic charges under
certain extreme condition. The user should ensure that the equipment is not installed in a location where it
may be subjected to external conditions that might cause a build-up of electrostatic charges on non-
conducting surfaces, additionally, cleaning of the equipment should be done only with a damp cloth.
• The equipment shall only be supplied via Terminals + w.r.t. Terminal – from a barrier having a maximum
open circuit voltage Uo that is ≤28 V and a maximum short circuit current Io that is ≤93 mA, where Io is
resistively limited. The barrier shall be ATEX certified by a notified body.
i. Following appropriate re-assessment to demonstrate compliance with the requirements of the latest
standards, the documents originally listed in section 9, IEC 60079-0:2000 Edition 3.1 and IEC 60079-
11:1999 Edition 4, were replaced by those currently listed, the markings were updated accordingly
i. Following appropriate assessment to demonstrate compliance with the latest technical knowledge, the
documents previously listed, IEC 60079-0:2004 Ed 4.0, IEC 60079-11:2006 Ed 5.0 and IEC 60079-
26:2006 were replaced by IEC 60079-0:2011 Ed 6, IEC 60079-11:2011 Ed 6 and IEC 60079-26:2014 Ed
3.0.
i. Following appropriate assessment to demonstrate compliance with the latest technical knowledge, IEC
60079-0 Ed.6:2011 was replaced by IEC 60079-0 Ed.7 2017.