ELECTRIFICATION PRODUCTS DISTRIBUTION SOLUTIONS (EPDS) SERVICE NORWAY – WEBINAR APRIL 2018
• Introduction.
• WebEx and Definitions.
• SafeRing/SafePlus.
• Changing face of the grid.
• Automation levels and Concept.
• Packages and options.
• Customer benefits.
• Product page and Distribution Solutions, Finland.
• Spare parts policy and Business Online (BOL).
• Q&A and Webinar.
• SafeRing is a Medium voltage (MV) gas-insulated Ring Main Unit (RMU) for
secondary distribution network upto 40.5 kV, 630A
• SafeRing: 12-24kV, 630A (SF6-insulated gas)
• SafeRing 36: 40,5kV, 630A (SF6-insulated gas)
• SafeRing Air: 12kV, 630A (Air-insulated gas)
• SafeRing AirPlus: 12-24kV, 630A (Mix of C5 and Air insulated gas)
• SafePlus is a gas-insulated compact switchgear system for secondary
distribution network upto 40.5 kV, 630A
• SafePlus: 12-24kV, 630A (SF6-insulated gas)
• SafePlus 36: 40,5kV, 630A (SF6-insulated gas)
• SafePlus Air: 12kV, 630A (Air-insulated gas)
• SafePlus AirPlus: 12-24kV, 630A (Mix of C5 and Air insulated gas)
• SafeRing combined with the SafePlus concept represent a complete
solution for 12-24kV secondary distribution networks.
• More than 200 000 units delivered worldwide
• Manually operated.
• Automated.
• RMU Digital Upgrade solutions are available for manually operated
SafeRing / SafePlus.
• Distribution
• Wind power
• Hydro power
• Generator
• Solar
• Infrastructure
• Industry
• Marine
Supply
• Dramatic renewables growth Customers will increasingly have
• Increasing intermittency to deal with very dynamic
• Greater volatility, less predictability environments
• More feed-in, take-off points (e.g. data centers
Grid of the
and EV-charging) The need for faster decisions and
future
• Increasing complexity, need for stability. On- real-time action requires visibility
and off-grid control of the entire business
• Automation on “local” level Energy storage is
key Digitalization is the answer for
the necessary agility and
decision-making velocity
Demand
• Continuing electrification of society
• Emerging market consumption growth
Control & information flow is key
Packages Options
• ARC600: Main controller, internal charger and wireless modem. • Local remote switch: Motor operation.
• Enclosure and heater.
• LV multi-meter:
• 2 x batteries.
ARC600
• Fault Passage Indicator (FPI):
– OC and EF non directional.
– OC and EF directional.
• RTU 540: Main controller and license. • Local remote switch: Motor operation.
• (Optional) Wireless gateway (ARG600).
• Enclosure and heater. • LV multi-meter:
ARG 600
• Sensors
REC615 – Indoor current sensor: KECA.
– Indoor voltage sensor: KEVA.
RIO600
Feeder Automation box inside the RMU/Switchgear Optimal utilization of the distribution network
• Fully integrated solution in the RMU, less space consuming. • Utilize the network more efficiently, minimize the network
• Fewer maintenance objects. losses.
• Less affected by the environment. • Optimal asset management.
• Fast and plugable installation. • Measurements of power flows/quality.
• No impact on compact secondary substation IP rating. • Improves overview of power network.
• Extends life cycle of the earlier investments.
Benefits of Compact Secondary Substation (CSS) automatization
Improves efficiency and safety of operating personnel
• Improved quality of the power supply:
• Less need to travel to places that are difficult to reach.
– Less and shorter outages.
• Less need to work in dangerous environments.
– Improvement of the operational efficiency.
RMU Digital highlights RMU Digital Upgrade functionalities enable network operators to
• Gain more efficient utilization of the secondary distribution • Obtain real time data for analyzing and decision making, in
network through automation and thus minimize the effect of order to optimize operations and improve power quality.
power outages.
• Monitor the grid to enable remote fault localization.
• Wireless modem GPRS/3G/LTE communicating with your DMS
• Reconfigure the network so that the faulty part of the network
or SCADA system.
is isolated and ensure faster power restoration reducing the
cost of energy loss.
In short it says
• All General questions, Request for Quotation (RFQ) or Orders
should ONLY come from your local EPDS Service (EPMV 3442)
center or some pre-approved Small Countries through
Business Online (BOL).
• This means if you are NOT a part of EPDS Service center or a
Small Countries, you should contact them for Service, spar
parts, or e.g. RMU Digital Upgrade.
• All EPDS Service center or Small Countries must have an pre-
setup organization in BOL.