FASTEST RESPONSE TIME: LESS THAN 3 SECONDS
HIGHEST RESOLUTION: 1mW OR .1 mg IN GRAMS MODE
MEASUREMENT RANGE: 0-30 WATTS
FREQUENCY RANGE: .5 TO 10MHZ
MEASURES TOTAL PULSED OR CONTINUOUS POWER
AUTOMATIC ZEROING & STABILIZATION
DIGITAL DISPLAY & RS-232 INTERFACE
OHMIC Instruments Newest Model UPM-DT-1000PA on the arm of the target cone. (A 1-gram weight is
provides the fastest response (under 3 seconds) and equal to 14.65 watts.) OHMIC also maintains NIST
the highest resolution (0.001 watts) of any current traceable masses and ultrasound standards, therefore
UPM-DT. The UPM-DT series have been in use the units can be returned for periodic recertification.
worldwide since 1986 and conform to the testing
The Importance of Calibrating Ultrasound Transducers
guidelines recommended by FDA, JCAHO, AAMI and
It is important to measure ultrasound power levels to
AIUM. Power is measured by the radiation force
verify correct patient exposure and reduce potential
balance method. The accuracy of the UPM-DT’s are
risks. All diagnostic and therapeutic Doppler and
traceable to NIST.
ultrasound equipment should be tested periodically.
Principle of Operation Typical safe values are defined by the temporal
The most reliable and repeatable means of measuring average intensity at the point in the acoustic field
ultrasound power is the radiation force balance where the intensity is at its maximum value, referred to
method. The transducer to be tested is centered as Spatial Peak Temporal Average (SPTA ). The FDA
above a 45° air-backed cone target in water media, and AIUM provide guidelines for the maximum SPTA
which is linked to a precision balance capable of values in medical applications. Typical safe SPTA
resolving 0.1 mg. When acoustic energy is applied to values are 10mW/cm 2 for echo sounding, 100 mW/cm2
the cone, the resultant force exerted on the load cell of for Doppler devices and 3W/cm2 for therapeutic use.
the balance is directly proportional to the total radiated The watt density (watts/cm 2) of a transducer is
power. The test tank is lined with sonic absorbent determined by measuring the total power output and
rubber to prevent power reflection. The balance is dividing by the active cross sectional area of the
programmed to convert milligram magnitude forces transducer. A sample form to document and report
directly to a readout in watts with resolution to the ultrasound performance is included in the manual.
nearest 0.001 watt. Verification of the UPM-DT-Series
is easily accomplished by placing a calibrated weight
WARRANTY: All products manufactured by OHMIC Instruments are warranted to be free of defects in material and workmanship
for one year after delivery. Any equipment found to be defective within this period will be repaired or replaced free of charge.
SF-SLS-503 (D)
SPECIFICATIONS - UPM-DT-1000PA
UPM DT-1000PA
Power Range 0- 30 Watts
Resolution/Uncertainty 1 mW (.1mg in grams mode)
Display Sensitivity 0.001 Watt
Accuracy ± 3% @10 Watts, 25°C
Zeroing Method Automatic
Response Time <3.0 Seconds
Maximum Transducer Size 4 1/2” Diameter
Transducer Operating Frequency .5-10MHz
Test Media Degassed Water
Computer Interface RS-232, 600-19200 Baud
Default Baud Rate 2400
Power * * 120 VAC to 12 VAC 500 mA
adapter with 6 Ft. cord
EMC EMC 2004/108/EC, Low Voltage
Directive 2006/95/EC, AS/NZS4251.1,
AS/NZS5252.1
CSA C&US CAN/CSA-C22.2 No. 1010.1-92
UL Std No. 3101-1
Electronic Compliance EN 61010-1:2001, EN 61326-1:2006
Size 11”H x 15” L x 10”W
Weight 16 Lbs Net
Carrying Case Black Anodized Aluminum
* Power packs and cord sets are available to meet any configuration or VAC needed.
ENGINEERING SUPPORT: OHMIC Instruments designs and manufactures a full line of environmental and bio-medical sensors,
instruments and controls. Many of our products are custom designed to meet specific requirements. Our engineers will be
pleased to discuss your application.