NABINAGAR U#I

Recycle Bin maxvUE Editor DOCUMENTS 1OWs2


172.16.160.6

ad-L.n--J
BRBCL- 1 COAL A BCD E FG PURGE
PULV DISCH DAMPER DE FG
BUNKER AS1ASco
ELEVAA-FLAME ELEV-AB-FLAME SEQUENCE
BUNKER MILL OL TEMP BURNER 2 BURNER
501
OL GATE 57.4°C Iso GATTE IsO GATE
DR I GATE
59.3C BURNER BURNERR RE00 Ms. 0OSess
COC ISO GATE IsO GATE STADTSEnUENCE
cURRENT
0.50mA
32.99TPH STOP SFQIIENCE
IGNPER AVAL
FEEDERR
PA HDR TXR 1 10mmWC HAG
OL GATTE 715mmc
OIL SYSHEALTHY PA HDR TR2
PA HDR TR3 716 mmuwC HOT
FEEDERRSA NO LOS TRIP AIR HEADER
DAMPFR BROTREADY PA FAN-A
33mmWvc MILL DP VFNTIURI
SA PULVBOWL DP --
FAN.A
823mmWC CAG
EPB NORMAL PA FAN-B
796 mmWC

DII VSn DAMDFR

ROLLER SETTING
CuRREN 6.35
IHS-
TANK LEVEL
SA FAN.R

MOTOR MINDING TEMP


AIR
COLD
HEADER
INNER SHAFT BRG
PLOS-A.B.C
49.95°c
NORMAL LOP A LOP B 164.32 mnm

176.82 mm
48.53c oUTER SHAFT BRG 45.01c
LUB OIL TEMP 47.23°c 48.08°c
LUB OIL PR LUB OIL FLOW AFT COOLER TANK OIL TEMP
46.44 c 47.32°C
2.10 Ke/CM2 164.88Lpm 34.97°C 37.18°C THRUST BRG
MOTOR BRG TEMP 47.67°C
2.09 KO/cm2 159.95Lpm 36.06 36.86 c NDE 24.51c DE 40.02°C
47.04°C

Clear
SBC PR OLABLFO COAL a SCAN FAN SEAL FAN Last Main Point

SBC-WALL SADC SBC-NDI Close Al1 Ack


FLAME 1 FOPH PopUps Point
"sgtCOALA.MN"
Recycle Bn maxvUE Editor N.ABINAGAR U=
DOCUMENTS IOWS

NABINAGAR 1
SCAN AIR FANS
ABCPEFG
ARAco
HOL DE FO
PURGE

SCANAIR
FAN A

SCAN DUCT FURN DP1 276.49MMVC


sCAN DUCT FURN DP2 277.62MMMYC
240.37mmWo
FROM FD FAN SCANAIR
DisC PR
CURRENT
DELIVERY TO ALL sCANNERS

FROM SCANAIR
ATMOSPHERE FAN B TO AIR CoOLED GUNS
TR
CURRENTT O.00
SCANNER
EMER DAMPER
F
HR
PA
HE

CD
PRD
PRDS
LF
GL
Clear CO
SBC PR oLABLFO cOAL A SCAN FAN Main
FANSEA Last
Point MF
FLAME 1 FOPH SBC-WALL SADC SBC-INDI Close A Ack
Point
PopUps "sg1S CANFAN.MN"
N.AIN.AGAR U=:1|
Recycle Bin maxvUE Editor DOCUMENTS 1OWS2

BRBCL1
SEAL AIR FANS ABCDEFG ou ro PURGE
ARIco
SAF A FAN BRG NDE TEMP 34.32DEO C

SA HDR TO CA DP-1 488.71mmWC SAF A FAN BRG DE TEMP 44.08 DEO C


SA HDR TO CA DP2 481.76mmwc 78.84 Amp
SA HDR PRESS 1437.8mmWC Fl

SA FANA

FROM COLD AIR


TO MILLS
LTE- MS.
MST
EHC
TRIP

|
LO
H2 F
0.05 Amps
FUR.F
HRH F
SAF B FAN BRG NDE TEMP 23.82DEOo c PA HD
SAF B FAN BRG DE TEMP 28.05DEO C HPBP
CD VA
PROS P
PRDS TM
LFO
GL ST PR
Clear COAL
SBC PR OILABLFO cOAL AA SCAN FAN SEALFAN Last Main Point MFT
FLAME FOPH SBC-WALL SADC SBC-INDDI Close Al Ack
Point
1I
Pop Ups "sgiSEALFAN. MN"
SBC (WALLBLOWERS)
BLONER IN REMoTE ALL BLOWER NOT IN HOME AUTO SEQ ON
POSN cOMPLETED
LRSTART RELERsSE NOT AVaL
SBC PR&TEMP CTRLS INTERRUPTED
CUE STERT RELEE NOTEVaL LR&AH BLOWER
SBC IND ICATIONS

12 13 14 1 TPH O TPH
1 5
10 11

26 28
15 16 17 19 20

40 41 42
E 29 30 31 32 33 34
21
22 23 24

35
36 37 38 39
E

54 55 56 44 45 46 47 48 49 50 51 52 53

U
|EH
TR
Le
LEFT SIDE
SB39 FRONT SIDE RIGHT SIDE SB40 REAR SIDE
HZ
DRN TEMP 241 DEGsC
FU
TO IBDT DRN TEMP 241
HRH
oEG PA
TO IBDT
SEQ-P1 SEQ-P2 SEQ-P3 HSEQ-P4 SEQ-P5 SEQ-P6 SEQ-P7
HP
CD
SEQ-P9 START SEQ STOPIRET RESET SEQ PROG CHK SEQ-PB PROS
aLn--J-.
NABINAGAR SBC
ALL BLOWER NOT IN HOME POSN
LR & AH BLOWERS) AUTO SEQ ON
cOMPLETED STARTUP
FROM MAIN STEAM INTERRUPTED
AUX STM
LRELRsTART RELERSE NOT BUA
BLONER IN REMOTE
LEFT SIDE RIGHT SIDE
64 60 H BLRR
-1 TPH STRT REL
TPH AVLBLE
70 66 62 61 65 69 APH-A APH B3

72
SB57

57
7 75
58 73 LSB-47 SB-48 EH
M
M

WALL TRE
74 DRN TEMMP
BLOWERS
SBC INDICATIONS HOME POs HOME PO Le
30 0EGC
SBC PRETEMP CTRLS
Ha

FU
SB25 HRE

PA
TO IBDT 240.930E TO IBDT HE
CD
SEQ-P3
SEQ-P1
SEQ-P9
SEQ-P2
START SEQ STOPIRET l SEQ-P4
RESET SEQPROG CHK
SEQ-P6 SEQ-P6
SEQCHK
SEQ-P7
ENA CHK
SEQ-P8
DISCHK
PRD
PRO
L
SBC
FLAME
PR
1
OLABLFO
FOPH
COAL A
SBC-WALL
sCAN FAN
SADC
SEAL FAN
SBC-INDI
Last
Close
Main
A
Pop Ups sglsBc-LR&A.MN"
7 Clear
Point
Ack
Peint
GL
C MI
S
NABINAGAR U#1
Recycle Bin maxvUE Editor DOCUMENTS 1OWS2
12 16.160.6

NABINAGAR SB6 Soot Blower Steam Pr./Temp Contro 03:41:54


M SD20
01Feb223
MAIN STEAM 4 LINE 0.2 VALVES IN REMOTE 37.

SBSTM PR D1 22.20 Ko/cM2 SELECTEDPRESS STARTUJP LI


T2 SBHDRFLOW AUX STM
s18 22.18 KO/CM2 22.19 Ko/CM2
s21 PR SET 20.00 Ko/cM2 0.42 TPH SG TG BOP E

SH DV PNL OL HDR suNE 0.2

25.1%
SB8

10 % LN
M SD21

25.2
STM PR1 LOWHOT END)

RPH
STM PR2 LOWHOT END)
RAPH-B
LOAD

FREQ
247.
SPEED 3o02.

5o.036

1.91 TPH 0.55 TPH BLORERS BLOMERS


2.65 TPH 1.77 TPH
STM PR1 LOWcOLD END) STM PR2 LOWCOLD END)
FURNACE FURNCE FRIONT REAR RGHT 247.6
SDE
LEFT RIGHTSDE SDE SDE MS. PR 141.1
LRBLOERS LRELONER DRN TEMP MSTMP 537
239 DEC

|
DX EHC SP 47.9
SB57 TRIP OIL
DRN TEMP LO PR
DX 240 oEGC H2 PR 3.9
DRN TEMP SB40 FUR.PR -9.9
DRN TEMP DX240DEC HRH PR 35.6
30 0EGC SB39 PA HDR 759.2
S:25 HPBP
NTE TTENT cO VAC .106
DOWN PROS PR 12.8
NK PRDS TMP 318.2

wALL BLONERS LRAH BLONERs SBC TND TCATIONS LFO


GL ST PR 344.85
COAL
Clear 3002.4
SBC PR OLABLFO cOAL A sCAN FAN SEAL FAN Last Main1HCB10AADO1
Point MFT
FLAME FOPH SBC-WALL SADC SBC-INDI Close A se MAIN ISOL VLv s18
UNIT 1/STEAM/SBCLRErsacLegierse.MOVS/S18/sBMair Ack
Pop Ups
1

sgSBC-PR1.mn" Point
NABINAGAR 1 SECONDARY ADR DAMPER CONTROLS 30.7 % U.OFA
URN-WB DPT
FUR-WB DPT- 107.21
SEL
mmWo SEL OUT 108.23 mmWc
1O0L.OFA, U.OFAA
Auto

Auto
100.09

212% GG
AAUX
AMPER Feed Rate-G tModulating
109.25 mmWe BIAS 5.00% PENINC
FUR-WEB DPT- 0.09
COAL 03:42:
BOILER UX AIR -0.01 TPH Manual 01
LOA 82.65% DEM 21.3%
cONTROL Fe
21.1 FG OlL
FUR-WB SP Modulating
105.00mmwc AUTO
BOILERLOAD ( Feed

32.45
Rate-F

TPH Auto
14.2 % COAL
TG

AUX AIRIOIL FUEL(COAL) AIR 3-FURN DP Vs BOILER L0 212% EF AUX


DAMP BIAS DAMP BIAS Feed Rate-E Modulating LOAD

O.00 % o.00 % 32.91 TPH uto


14.3
E COAL
SPEED
WE TO 21.1% DE OIL FREQ
FURDP 60 Feed Rate-D
tModulating
O.00 % O.00%
nrwc40
32.25 TPH Auto
14.1 %
D COAL

O.00 % 0.00 %
30 45 60 Feed Rate-C Modulating
CD OIL MU
MS. PR
BOILER LOAD (% 0.0 % cOAL MSTMP
o.00 O.00%
-0.04 TPH Manual EHC SP
FUEL DAMPER TRIP OILL
O.00 % o.00% Feed
BC AUX LO PR
20 Rate-B
Modulating
H2 PR
17.7% cOAL
O.00% FUEL 38.55 TPH FUR.PR
O.00% AIRR
uto
DAMPERR HRH PR

O.00% O.00 % OPENING5


Feed Rate-A
AB OIL PA HDR
Modulating HPBP

o.00
25 60
33.24 TPH Auto
14.8 %
2 cOAL CD VAC
PROS PR
PRDS TMP
o.00% FEEDER SPEED LFO
GL ST PR
Clear COAL
KAVERI VAIGAI Last Main Point MFT
GANGA YAMUNA GODHAVERI S Ack
BONGAIGAON-1 HPBP SYSTEM
MAIN STEAM LINE BPE1 TEMP TXR

257.6DEc
BPE DoWN STEAM TEME
MS PRESS 253.9 DEo c

HPBP SELE PRESS1142.77Ko/CMS 142.43 Ko/CM2


HPBP PR SEL. 148.60Ko/sa BPE1 SEL TEMP TR VALU 255.78 Degc

BPE-1 TEMP SET POIN 340.00 DEG C

BP 1 FAST OPEN
MERGENCY FAS BP 1 PRI cLOSE
OPEN -5.0
0.38%

HPEP PRESS SETPoRT


HPEP TEPSET PonT BP1 BPE
BP 2 FAST OPEN SPRAY WATER
LINE
BP 2 PRI CLOSE

OIL
PUMP-1

PUMP2
ON OF MCC

SUPPLYUNIT -1
.
LOWLOMHIGHIG
V.
-2.7%

BP2
1.38%

BPE2
BPE2
BPE2 TENMP

DowN STEAM TEME


BD
DR
270.6DEc
268.9DEGc

BPEZ SEL TEMP TR VALUE : 269.80 DegC


OIL SUPPLY UNIT -2 BPE-1 TEMP SET POIN 340.o0 DEG C

cOLD REHEAT LINE LP BYPAss

Clear
GANGA YAMUNA GODHAVERI KAVERI VAIGAI Last Main
Point

MAHANATDHH sINDHU KABINI KARNATAKA| INDIA Close


Pop Ups
Al
"soNHPBP.MN" TE Ack
Point
BRBCL-1 AUX PRESS REDUCING & DE-SUPERHEATINGSYSTEM
CD-02 CD-01 CD-15

143.20 KorCMa AS-10


SEL
0.76 TPH 614.62 DEO C

MAS-09

0.87% 26.97 DEGGC

AS-101
AS-102
AS-09 1BV

AS-12
2.06%

XR318.01 DEG C
CD-04
M CD-05

LINE SEL
SP WTR
LINEFROM
CEP DISCH

M TX
SP 318.36 DEG
0.04%

MS LINE
306.58 DEG C
AS-13 48.34 KG/CM2
12.67 Ka/om2 AS-65
HT AUX.
AS-12 IBV
AS-24 M STM STN HDR AS-56
From HT UNIT-2 HDRR
LO

2.64TPH 37.69 AS-48 SPE


KG/CMAS-188 AS-1 c
318.18 Deg
c AS-54
SELCRH LINE 324.10 DEO FROM FRE

AS-106
STN HD
L
1.96 M
5.39 CD-07 LINE SEL
MAS-105 TXR 12.57 KO/CM
SP 12.57 Ko/cCM
cD-11 M 0.00 DEG c
TO
12.57Kg/em
C EQP
. PI
CD-10 MSTM
AS-22 AS-28 192.03 DEG 0.78% AS-34 EHC
TKR 12.29KG/c S
SP AS-46 TRIP OI
191.92 DEG LT HDR UNIT-1 FROM AUX
HDR
From LT Unit-3
BOILER LO PR
LTAUX STNHOR H2 PR
AS-58 AS-60 FUR.PR
AS-59 AS-03 o.00OEGc23.82Ko/CM HRH PR
PA HDR
ASUZ 0.00 22.88 KG/CM TR HPBP
From LT UNIT-2 HDR 23.19 KoCM cOVAC
PROS PR
TO AG EQuIPMENTOF MAIN
PLANTS TG auILOING PRDS TMP
AS-67 AS-05 LFO
AS-06
GL ST PR

Clear COAL
GANGA YAMUNA GODHAVERI KAVERI VAIGAI Last Main Point MFT

MAHANATDH SINDHUU KABIN KARNATAKA INDIA Close A1


Pop Ups "sgAPRDS.MN" TE Ack
Point
NABINAGAR U#
Recycle Bin maxvUE Editor DOCUMENTS |1OWs2
172.16.160.6

aJ-L n-J-
BRBCL_1 ERV CONTROL ERV CLOSED h MANUAL
PC svo6
S46 S61 SV6-ER LINE ERV PR.SWITCH SETTIN
S62
S 42 s43 FOR ERV OPENING- 164.2 KGK
SH MS-L $45 FOR ERV CLoSING-158BKKGIK
ERV
CLOSED
PC
D
Svo07
MANUAL
ERV CLOSED

PC) CmSvoB
MANUAL

s48 SV7-ERN S52 S675V8-ERU S55


S63 s52 S 53
S47 s64 S51 S68 Ss4
S54
MS -R
ERV CLoSED
MANUAL
PC SV14
k19 R26 V14-ER LINEERV PR.SWITCH SETTIN
HRH-L
R18 27 R67 M RSB .FOR ERV OPENING-42.1 KGIC
FOR ERV CLoSING-41.2KGIC
RH ERV CLOSED
MANUAL
PC SV15
R21 R28 15-ER
R65
R20 R29
HRH-R

GANGA YAMUNA GODHAVERI KAVERI VAIGAI Last Main

MAHANATDHsINDHU KABINI KARNATAKA NDIA Close A TE AC


Po:
Pop Ups "sgNERV cONTROL.MN"
NABINAGAR U=1|
Recycle Bin maxvUE Editor DOCUMENTS 1OWS2
1216.160.6

aJL.-
BONGAIGAON 1 SCAPH DRAIN TANK LEVEL CONTROL
LEVEL SET LEVEL SET
aiLAUi mm nAui mm

VENT ASSC-78 VENT ASSC-79

FOR SPRY
FOR SPRY
PRI SCPH SEC 8OAPH
DRAN TANK
DRANTANK
-1.92MM
ASSC-S9
ASSC-60D

100.0 XR -1.00Man
ASSC-67 ASSC-668

0.1%
99.7

ASSC-70 37.9x
ASSC-62 ASSC-63 ASSC-71

M ASSc-66
MASSC-74

O IBD TAN

O IBD TAN
Clear
SA NGA YAMUNA KAVERI VAIGAI Last Main
GODHAVERI Point

SINDHU KABINI INDIA Close A1 Ack


MAHANATDH KARNATAKA| PopUps "sgSCAPHDRN.MN TEPoint
BONGAIGAON 1 FUEL OIL SYSTEM coEF 03
toHO 01
LFO
HDR PR
15 KGC2 TO LIGHT OIL
ATOM STM
FROM LFO BURNER
TO BURNER'S FLOOR
HDR PR
ATOM STM SG
LFO FOR AUTOMISATION TXR 0 KCCM2 0.0%
PUMP LO-24A LO23A
14
LO248
SP LOA
o833A Os34B
LOJOA
M
LO-24C
41.0

LO23B
1LO24B 0.0
SPEE

FREG

FROM
FROM Os34D STM
AIR HFO os338 AUDK
HDR PR HDR
HDR
HO34A 50.1% TXR 15
KGC2
MS. PR
HFO
HO33A
1HI
HO34CH034E STRAINER DP HIGH
DRAIN OIL MSTMP
|EHC SP
TRTP 0TL
TO HFOTANK HO 62A FROM DRAINSLO PR
34.9% HO HO 61B HO 64 H2 PR
HO408 61A

HO448 HFO DO STRAINER


HO 63A
FUR.PR
STEAMFROM ATM HRH PRR
HO34D HO33B HO34B H094F STM OPR'G FLOOR PA HDR
HPBP
RING OS 70A os 118R
DRAIN CD VAC
HO48A HO4SA
HO45A MBURNER
HEADER RETURN
OIL
PROS PR
FROM TO TANK
HFO COND HDR PRDS TMMP
PUMP HFO TO
TANK LFO
HOUSE GL ST PR
COAL 30
KAVERI VAIGAI Last Main Clear
GANGA YAMUNA GODHAVERI Point MFT

MAHANATDH SINDHU KABINI KARNATAKA INDIA Close A Ack


Point
Pop Ups "sgiHFO.MN"
NABINAGAR U=1
Recycle Bin maxvUE Editor DOCUMENTS 1OWS2
1 16 160.6

JL-n--J-*
ONGAIGAON CBD TANK LEVEL CONTROL

VFNT
t LEVEL SET
nAaN NAmm

FOR SPRAY

TXR 0.17MM 0.2%

0.0%

TO LP TO IBD
FLASH TANK TANK

Clear
GANGA YAMUNNA VAIGAI Last Main
GoDHAVERIKAVERI Point

MAHANATDH sINDHU KABINI KARNATAKA INDIA Close A Ack


Point
Pop Ups "sgcBD.MN"
ecycle Bin maxvUE Editor
|NABINAGAR U#1
DOCUMENTS 1OWS2
12.16.
160.6

ACTUATORS BOILER AREA

O.0%
M
o.0
M
O.0%
M M
23.% 0.0%
S
HAN34AAO51 HAN3 3AAO51 HAN3 3AA0011 HAN32AAO01 HAN32AAO51 HAN31AAO51 HAN47AAO03
SH I/L
S63
HDR DR H I/LHDR
S61
DR SH DR ISO
S60
LV SH DR ISO VLVSH DR INCH VLY
S58 S59
FSH DR VLV
S5z
RH O/L STRTUP
WENT R6
HAN47AA051
RH 0/L STRTUUP
WENT RZ
Le

SP

M M M M FR

HAN12 AAO01 HAN12AA002 HAN12AA003 HAN12AA004 HAN2 4AA001 HAN2 4AA002


DRUM AIR VENT DRUM DRUM AIR VENT DRUM AIR VENT oHAN11AA001
TO DRUM VE o HAN11AA002
TO DRUM VEN
1EFTAIRBA2
VENT SH HDR VENT5H 0/LHDR
LEFT BO1 RTGHT RO3 RTGHT BO4 F24 F25
0/L_
S11 S12 VENT MS.

E
M M
-1.0 %
M
MST
EHC
TRIP
LO
H2 P
P

FUR.P

HAN2 7AA001 HAN2 7AA002 HAN30AAD01 HAN3OAAO51 HAN2 8AA001 HAN29AA002 HAN47AA001 HAN47AA002 HRH P
DESH 0/L VENT DESH 0/L
20 VENT SH STRTUP VENT SH STRTUP VEN FSH VENT IS FSHVLY
VENT ISOL R3 R4
S19 S26 TNCH TYPE-S27 VLV S21 S22_ PA HD

M HAN10AAO51
Co I/L HDR DR
HPBP
CD VAC
PRDS P
PROS TM
1.9
VV E18 LFO
GL ST PR
Clear COAL
GANGA YAMUNA GODHAVERI KAVERI VAIGAI Last Main Point MFT

MAHANATDH SINDHU KABINI KARNATAKA INDIA Close


Pop
AUps T Ack
Point
"SOLACTUATORS.mn"
BRBCL-1 APH-A BLOWER SCAN FAN-A
RACT OIL AB(LIGHT OIL
TOID Nn TDID PURGE
DE-1 DE-2 DE-3 DE-4

BLOWER
SCANAIR
DISC PR 243.92mmWc

AACT APH-B
TRID ANA TOID START CD-1 CD-2 CD-3 CD-4
sCAN FAN-DO
PURGE REAL
AACTT
TOID 00 Seconds
AIA TDID
AB-1 AB-2 AB-3 AB-4 ABCD EFGCD E PURGE

STEP COMPLETE STEP COMPLETE


ATOM AIF 6.98 Ko/om2 6.99 Ko/om2

AANV STOP 205 STOP


AM
DC PWRAVAIL 15.48 Kgcm2 REL AVAL REL AVAAL

15.50 Kg/om2

LOTV
15.48 Kg/om2 sCAV
VLV S S sCAV
VLV
34.5 15.48 Kg/om2

LO24A LO23A LONV2 LONV3


HFO SYSTEM AB 1 IN REMOTE
COR2 NO TRIP cOR3 No TRIP
AB2 IN REMOTE
AB3 IN REMOTE
LO24B 41.1 IN REMOTE
CORA NO TRIP
AB 4 COR1 NO TRIP
AANV
LO23B SAANV
SELECTIO LO SELECTED
PAIR1&3
000Secs
START TIME
STOP TIME 000Secs
SCAV
vLv S REL AVAL
sCAV

REL AVAL
PAIR2 &4
START TIME 000 Secs
LONV1 STOP 205 STOP
205 LONV4

STOP TIME 000 Secs STEP COMPLETE STEP COMPLETE

Main Cle
GANGA YAMUNA GODHAVERI KAVERI VAIGAI Last
Poi

SINDHUJ KABINI KARNATAKA| INDIA Close Al TE Ac


MAHANATDH PopUps "sg\OILABLFO.MN
Poi
aJL---J-
NABINAGAR-1
ATOM STEAM OIL AB (HEAY OIL) 03:46:41
3
STEP RESET
ABCDEFG STEP
LO co

COMPLETE
oE FO
PURGE
01Feb23

SG TG BOF ELE
501 STOP 205
SASNV START
REL AVAL REL AVAL LOAD 248.9
SCAV SCAV SPEED 3002.7
HOTV SVLV
49.6 FREQ 50.055

15.46 Kg/om2 HO34C HO33A HONV2 HONVS


PRADOT
240.9
34.8 34.8% MS. PR 142.4
TEMP ADQT MSTMP 537
EHC SP 45.7
H034D HO33B TRIP 0IL 8.3
SASNV LO PR

7
2.7
SELECTIONS AsS
HFO HDR TME H2 PR 3.9
LO SELECTED FUR.PR
HFO HDR PR PAIR
STOP TIME
1&3
000 Secs
SCAV
Lv S HRH PR
-22.4
35.9
PA HDR 741.7
PAIR2 &4 HPBP
STOP 000Secs
TIME REL AVAL REL AVAL CO VAC 0.105
HFO SYSTEM STOP 205 STALRT 501 PRDS PRR
HONV1 HONV4 12.6
PRDS TMP 318.2
STEP COMPLETED STEP RESET LFO
HO48A HORV GL ST PR 361.65
Clear COAL 3002.7
GANGA YAMUNA GODHAVERI KAVERII VAIGAI Last Main
L Point MFT
A
MAHANATDHH sINDHU KABINI KARNATAKA| NDIA Close
Pop TE Ack
Point
NABINAGAR U#1
Recycle Bin maxvUEEditor DOCUMENTS 1OWS2
172.16.160.6

MILL-REJECT OVERVIEW REL HOT AVL


OYEYOR A REL HOT AVL cORVEYoR A RELNOT AVL cONVEYOR A RELNOTAVL

V.1 LBT 0 EC OSEC 0SEC Leveel

O SEC 0SEC eve 0SEC evel


Level
Te mn
CGT evel oSEC Tem DSEC
OSEC Temn
Te mr pVT OSEC 0SEC 0SEC
oSEC
OsEC
0SEC CT OSEC

Fo Seal Seal Sea


a ERVICEWATER PR OK ENGV
LENGE
Convey Air IConvenr Air Pressi ConveyAir Pressuur
Pressure
lConvev Air Press

Cnva
cONVEYOR A RELNOT AVL cONVEYOR A REL NOT AL
eve level H
OVEYOOR A REL HOT AVI 95SEC ev2 0SEC
Te mn Hi Te m Temn Hi
OSEC OSEC 0SEC
0SEC OSEC OSEC
OSEC O SEC
oSEC
OSEC (Seal INŠTRUMENT AIR PR OK Sea AIR RECIVER TANK PR
Seal
OK

Convev Ar Pressure Hi
Convey Air Pressure Hi ConveyAir Pressure High

Clear
ATT VLVs TURTRIP1 TURTRP2 KAVERI VAIGAI Last Main
Point
Close Al Ack
MAHANATDHH SINDHU KABINI KARNATAKA|| INDIA Point
Pop Ups
"sgimillteject_ Ovenview.mn"