Ac Induction Motor Data Sheet Crown Triton Motors

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

AC INDUCTION MOTOR DATA SHEET

CROWN TRITONTM MOTORS

MODEL NUMBER HHI200-18-447TC-F2


HORSEPOWER 200
RPM / POLES 1800 / 4
VOLTAGE / PHASE 460 V / 3
FRAME 447TC
ENCLOSURE / DEGREE OF PROTECTION TEFC / IP55
FREQUENCY 60 HZ
FULL LOAD SPEED 1785 RPM
SERVICE FACTOR 1.15 SF at 40° C / 1.0 SF at 65° C
INSULATION CLASS F Class N Varnish
FULL LOAD AMPS; 460 222.4 A
LOCKED ROTOR CURRENT (% Full Load) 700 %
NEMA CODE LETTER G
LOAD EFF. P.F.
100 % 96.2 % 88.0 %
EFFICIENCY / POWER FACTOR
75 % 96.3 % 86.2 %
50 % 95.4 % 80.6 %
DUTY CYCLE S1 / Continuous
FULL LOAD LRT BDT
TORQUE
592.0 lb.ft. 140 % 220 %
NEMA DESIGN B
LOAD (Max.) MOTOR
MOMENT OF INERTIA
2307.790 lb.ft.2 73.030 lb.ft.2
SOUND PRESSURE LEVEL ( No Load 1 M From Motor) 83 dB(A)
NUMBER OF STARTS (Hot / Cold) 2 Hot / 3 Cold
MAX. AMBIENT TEMPERATURE 40° C at 1.15 SF / 65° C at 1.0 SF
MAX. ELEVATION 3300 Ft. Above Sea Level
TEMPERATURE RISE (At Full Load) 80° C
DRIVE-END BEARING 6318C3
OPPOSITE DRIVE-END BEARING 6316C3
GREASE TYPE Mobil Polyrex EM
MOUNTING F1 (F2 Suitable), W6, W8, B3, V5, V6
ROTATION Bi-Directional
APPROXIMATE WEIGHT 1860 lbs.
AREA CLASSIFICATION Class I, Division 2, Groups A, B, C, D
INVERTER RATING 10:1 CT / 20:1 VT - Meets NEMA MG1 Part 31
SPECIFICATION - In Accordance With NEMA, CSA

CC 038A
REVISED 01/11/17
•0 I 2 I 3 4

TEFC
ID.HYUNDOI THREE PHASE INDUCTION MOTOR TYPE t----------1
LP, JP
8 HEAVY INDUSTRIES LTD.

Zi
G co .. G
Cast iron frame

::>
FRAME SIZE OUTPUT(HP) POLES Hz TIME RATING
0
-- 447TC-F2 60 CONT
p C
AB AH AG

----
F AC L F
I
BBMin XN
(KEY LENGTH) FS

E
= I�
_i__-=F ��"""IWiiiiiiijiiiiiiiiiS:li_-1
I

-------1------I "\
/

BC F3
N-W BA 2F2 8( 4)-H Holes

2F1
B

0
z DIMENSIONS
s:
<(
D D
0::: MOUN TIN G CONDUIT
BOX
0 APPROX.
A B 2E 2F1 2F2 F3 G J H AA AB AC XB XL XN WGT.(LB)
(f)

-
20.51 22.72 18.00 20.00 (17.99) 10.000 1.42 3.07 0.81 3.00 21.26 18.03 3.83 11.65 10.63 1970
-
0 V E R A L L S H A FT KEY BEARI
NG
K EYWAY DRIVE OPP.
C D L 0 p T AG u N
-Wt--R-�E=s�-s-----i
T HK. END
DRIVE
END
C
48.71 11.00 22.71 23.19 22.44 4.33 40.21 3.375 8.50 2.880 6.93 0.875 0.875 6318C3 6316C3

D-F L AN G E

AK BB Min BC BD BF BF depth n AH
16.00 0.25 0.25 16.93 5/8-11 0.94 8 8.25

B B
NOTE
1.Dimension "D" tolerance : +0.00inch � -0.03inch (143TC-365TC) : +0.000inch � -0.06inch (404TC-449TC)
2.Dimension "U" tolerance : +0.000inch � -0.0005inch (143TC-215TC): +0.000inch � -0.001inch (254TC-449TC)
3.Dimension "R" tolerance : +0.000inch � - 0.015inch
- 4.Dimension "AK" tolerance : +0.000inch � -0.003inch (143TC-286TC): +0.000inch � -0.005inch (324TC-449TC)

CAD PROJ \ FILE


APPD BY K.J. K AN G UNIT IN CH
- -------
SU BJECT 447TC MMSTDMTR\A1319M
CHKD BY S CALE N/S
A CHKD BY ------- � PROJEC'N 3rd Anqle
TITLE

OUTLINE A
DSND BY N.D. LEE DATE 201 1.02.09

btr(Y�� 1
Electro-Electric System Division
I 2 I
R EF.NO

DWG NO
3
350A1319M
A131 9AA

4
SheetNo.

Revisio n No.
of

0
CURVE NO.
PERFORMANCE CURVE
P-PLP447SR04

Type : PLP 150 kW 200 HP 60 Hz


Full Load Torque : 592.0 lb.ft 4P Rated Speed : 1785 RPM
2
Motor moment of Inertia (J) : 73.030 lb.ft Rated Voltage 575V 460V
Load moment of Inertia (J) : 2307.790 lb.ft 2
Full Load Current 177.9A 222.4A

SPEED VS TORQUE & CURRENT CURVE

350 800
CURRENT
300 700

600
250

CURRENT IN %
TORQUE IN %

500
200
400
150
TORQUE 300
100
200

50 100

0 0
0 10 20 30 40 50 60 70 80 90 100
SPEED IN %

OUTPUT VS EFF., P.F & CURRENT CURVE

100 200
EFF.
90 180

80 160

70 P.F 140
EFF. & P.F IN %

CURRENT IN %

60 120

50 100

40 80
CURRENT
30 60

20 40

10 20

0 0
0 25 50 75 100 125
LOAD IN %

RM-P251-133 A4(210mm x 297mm)


CURVE NO.

T-PLP200-18-447TC-F2
Type : PLP200-18-447T 200 HP 4 P 60 Hz
FULL LOAD TORQUE : 592.0 lb.ft RATED SPEED : 1785 rpm
J OF LOAD : - lb.ft² VOLTAGE 460 V 575 V
J OF MOTOR : 73.0 lb.ft² RATED CURRENT 222.4A 177.9A

10000

1000
Time(sec)

100

10

1
100 200 300 400 500 600 700 800
Current(%)

THERMAL LIMIT CURVE AT COLD CONDITION


THERMAL LIMIT CURVE AT HOT CONDITION
TIME VS. CURRENT CURVE AT RATED VOLTAGE STARTING
TIME VS. CURRENT CURVE AT 80% OF RATED VOLTAGE STARTING

STARTING TIME SAFE STALL TIME


- at rated voltage starting 21 sec. at Hot condition
at Cold condition
- at 80% of rated voltage starting 29 sec. at Cold condition

RM-P251-133 A4(210mm x 297mm)