SLC TWIN PRO2, UPS 4kVA - 20kVA
SLC TWIN PRO2, UPS 4kVA - 20kVA
SLC TWIN PRO2, UPS 4kVA - 20kVA
Operating modes
On-line double-conversion Batteries Eco-mode
Double voltage conversion (AC/DC + DC/AC), In the event of power failure, the loads con- Increased efficiency up to 99%, with imme-
providing the best degree of safety to loads. tinue to be powered by means of batteries. diate availability of full power.
Frequency converter
Adaptation of the output frequency to the
needs of the load (50/60 Hz or 60/50 Hz).
Range
POWER DIMENSIONS WEIGHT
MODEL CODE (VA / W) (D × W × H mm) (Kg)
INPUT /OUTPUT
Dimensions and weights for devices with standard backup with 230 V input voltage or 3 x 400 V, 230 V output voltage.
Dimensions 250 mm
250 mm
826 mm
576 mm
592 mm 815 mm
SLC 4000÷10000 TWIN PRO2 SLC 15000/20000 TWIN PRO2
SLC 8000/10000 TWIN/3 PRO2 SLC 15000/20000 TWIN/3 PRO2
Connections
1. USB interface.
2. RS-232 interface.
3. Emergency stop (EPO).
4. Intelligent slot for SNMP / AS400 /
RS485-Modbus.
5. Manual Bypass.
6. Input protector.
7. Terminal cover.
8. Thermal rearmable input.
9. Socket IEC output.
10. Parallel ports.
11. Earth connection.
Technical specifications
MODEL SLC TWIN PRO2 SLC TWIN/3 PRO2 SLC TWIN PRO2
4-10 kVA 8-20 kVA 15-20 kVA
TECHNOLOGY On-line, double conversion, PFC with double DC bus
FORMAT Tower
INPUT Rated voltage 208 / 220 / 230 / 240 V (1)
3 × 380 / 400 / 415 V (3F +N) 208 / 220 / 230 / 240 V (1)
Voltage range 110 ÷ 276 V (2) 3 × 190 ÷ 478+N (2) 110 ÷ 276 V (2)
Rated frequency 50 / 60 Hz
Frequency range ±10%
Total harmonic distortion (THDi) <4% <5%
Power factor ≥0.99
OUTPUT Power factor 1 0.9
Rated voltage 208 / 220 / 230 / 240 V (1)
Voltage accuracy ±1%
Total harmonic distortion (THDv) ≤1% linear load; ≤4%
≤2% linear load; ≤5% non-linear load
non-linear load
Synchronised frequency ±4 Hz
Free running frequency ±0.1 Hz ±0.05 Hz
Total performance in On-line mode 93% ÷ 94% 88% ÷ 90%
Admissible overloads Up to 110% for 10 min; 130% for 1 min
Crest factor 3a1
Parallel Yes, up to 3 units(3)
BYPASS Type Hybrid
Transfer time Nil
MANUAL BYPASS Type No breaks
BATTERY Protection Against power surges, undervoltages and alternating current components
Battery type Pb-Ca sealed, AGM, maintenance-free
Charge type I/U (constant current/constant voltage)
Recharge time 7 ÷ 9 hours to 90% 9 hours to 90%
CHARGER Temperature voltage compensation Yes
COMMUNICATION Ports USB, RS-232 and relay
Intelligent slot Yes, ready for SNMP / AS400 / RS485-Modbus
Monitoring software Downloadable for Windows, Unix, Linux and Mac
OTHER FUNCTIONS Cold start (start-up from batteries) Yes
OPERATING MODES Eco-mode Yes
Frequency converter (CVCF) Yes (4)
Yes Yes(5)
GENERAL Operating temperature 0º C ÷ 40º C