2 – 251 0.1 - 1 0.1 – 2 5 - 100 1 – 201 -1 0.12 – 2.4 5 - 100 0.6 - 121 -5 0.075 - 1.5 3.8 - 80
3 – 60; 0.2 - 3 0.15 – 3 8 - 160 2.4 – 48 0.1 - 2 0.16 – 3.2 8 - 160 1.5 - 30 0.1 - 1.5 0.1 - 2 5 - 100
20 – 400 1 - 20 0.25 – 52 13 - 265 16 – 320 0.8 - 17 0.24 – 4.82 12 - 254 10 - 200 0.5 - 10 0.15 -32 7 - 160
30 – 600 2 - 30 0.3 – 62 16- 310 24 – 480 1.2 - 25 0.32 – 6.42 17 - 338 15 - 300 1.5 - 15 0.2 -22 10 - 100
20 -
50 – 1000 3 - 50 0.4 – 82 20 - 420 40 – 800 2 - 42 0.4 – 82 25 - 500 1.5 - 25 0.25 -52 13 - 260
420
75 – 1500 4 - 80 0.5 – 102 26 - 530 60 – 1200 3 - 63 37 - 740 2 - 38
80 – 1600 4 - 85 50 - 10002 3 - 50
1
AVAILABLE WITH 3 ” FLOWMETER ONLY; 2AVAILABLE WITH 5 ” FLOWMETER ONLY
(gas supply). For the connection of the gas control Complete shut-off:
unit to several points of application acording devices The OFF position of the selector knob allows for the shut-
and connectors are available. The flowmeter is freely off of the vacuum regulator. The containers can be changed
accessible and can be easily removed for maintenance. without admitting air, dirt or moisture into the control unit
Injector and without the need for shutting-off the injector.
Fixed-throat injectors develop the necessary vacuum for Automatic switch-over (option):
the operation of the S10k™ gas feed system by means The integral switch-over eliminates the need for external
of the operating water. An integral bracket is provided switching devices. The cylinder can be fully emptied, with
for horizontal as well as vertical mounting. The injectors the possibility to maintain a positive pressure in the empty
include two independent check valves to prevent water cylinder (option).
from back-flooding into the vacuum control valve when the
system is shut-off. Operating range: manual 1 : 20 for any feed range
Gas cylinder empty signal (option):
INJECTORS:
Connection 4 kg/h 10 kg/h Volt-free contact (max. 3 VA, 24 V DC)
Gas dosing unit PVC pipe Injector/operating water:
DN 20, DN 25 DN 25, DN 32 The injectors are available in two sizes: 3/4 ” up to 4
Solution outlet same as inlet PVC pipe kg/h and 1 ” up to 10 kg/h. Depending on the operating
DN 20, DN 25, DN 32
conditions (gas feed range, operating water pressure) the
injector throats are specified according to the application.
Vacuum control valve: Inlet pressure:
Tubing to gas dosing unit3: max. 16 bar up to 38 °C/max. 10 bar up to. 55 °C
PE-hose 1/4 ”, 3/8 ”, 1/2 ”; PVC-pipe DN 15, DN 20, DN 25
3
The nominal diameters of the connecting lines are a function of the gas feed rate and Back pressure:
the length of the line. max. 11 bar (depending on line specifications and
operating water temperature)
Cylinder or tank connection:
Direct connection to cylinder or header valve or to
flexible lines, manifolds
Auf der Weide 10, 89312 Günzburg, Germany
S10k and Wallace & Tiernan are trademarks of Evoqua, its subsidiaries or affiliates, in some countries. All information presented
herein is believed reliable and in accordance with accepted engineering practices. Evoqua makes no warranties as to the
completeness of this information. Users are responsible for evaluating individual product suitability for specific applications.
Evoqua assumes no liability whatsoever for any special, indirect or consequential damages arising from the sale, resale or misuse
of its products.
© 2016 Evoqua Water Technologies GmbH Subject to change without notice WT.025.200.000.IE.PS.0116
Wallace & Tiernan® Products worldwide
Australia Canada China France Germany Singapore UK USA
+61 3 8720 6597 +1 905 944 2800 +86 10 57076305 +33 1 41 15 92 20 +49 8221 9040 +65 6830 7165 +44 1732 771777 +1 856 507 9000
info.au@evoqua.com canadainfo@evoqua.com sales.cn@evoqua.com wtfra@evoqua.com wtger@evoqua.com sales.sg@evoqua.com info.uk@evoqua.com wt.us @evoqua.com