Valv-Powr® Series VPVL Model D Double-Acting and Spring-Return Rack-And-Pinion Compact Pneumatic Actuators
Valv-Powr® Series VPVL Model D Double-Acting and Spring-Return Rack-And-Pinion Compact Pneumatic Actuators
Valv-Powr® Series VPVL Model D Double-Acting and Spring-Return Rack-And-Pinion Compact Pneumatic Actuators
MODEL D DOUBLE-ACTING
AND SPRING-RETURN RACK-
AND-PINION COMPACT
PNEUMATIC ACTUATORS
Valv-Powr – VPVL double-opposed piston actuators
combine the benefits of high cycle life, a rugged con-
struction, and an extremely compact and symmetrical
design with a unique range of features and options.
They are specifically designed for fast efficient opera- Corrosion Resistant
tion of ball, butterfly, and other rotary type valves. ■ Hard-anodized PTFE-coated body, polyester-coated
FEATURES end caps, and epoxy-coated springs, along with
Single-Source Responsibility internal and external stainless steel fasteners,
■ Valves, actuators, and accessories are designed to oper- provide corrosion resistance in a variety of difficult
ate as a unit with the highest degree of compatibility. applications and environments.
■ Valves, actuators, and accessories can be supplied
Reliability
completely assembled to provide unit responsibility
from a single source.
■ Safety-contained multi-spring design with preloaded
Versatility and heavy-duty coated springs for simpler range
versatility, greater safety, and corrosion resistance.
■ Modular designs with same body and end caps for
double-acting and spring-return reduce inventory.
■ External adjustable stops in both directions assure
Springs can be added in the field to convert double- flexibility and accuracy when setting the valve in
acting to spring-return or for changes in supply pressure. the open and closed positions.
■ Failure direction can be easily reversed from spring-
■ As an added safety feature, the external adjustment
to-open or spring-to-close orientation simply by screws are slotted.The slot will indicate the presence
inverting the pistons. of internal pressure. Pressure will begin to vent
before the adjustment screws are completely
■ Actuator to valve attachments comply with ISO 5211.
backed out of the actuator.
■ Solenoid valve and accessory attachments comply
with NAMUR VDI/VDE 3845. SPECIFICATIONS
■ A wide range of optional accessories and control Maximum Supply Range: 116 psi (8 bar)
devices that include limit switches, solenoid valves, Temperature Range:
and mechanical safety lockouts are available to satisfy Standard -40°F to +176°F (-40°C to +80°C)
virtually all automated valve requirements. Options 5°F to +302°F (-15°C to +150°C)
High Cycle Life -60°F to +176°F (-51°C to +80°C)
■ Bearings on all sliding and rotating moving parts to Rotation Adjustment: Close -5° to +5° from 0°
ensure long life. Open +5° to -5° from 90°
■ Dual piston rack-and-pinion mechanism for simple Supply Media: Air, mineral-based hydraulic fluid
construction, high cycle life, and constant torque. STANDARDS
■ Hard-anodized PTFE-coated extruded aluminum Actuator to valve mounting: ISO 5211
body with honed internal surface for strength and Actuator to solenoid mounting: Namur,VDI/VDE3845*
lower coefficient of friction. Actuator to accessory mounting: Namur,VDI/VDE3845
■ Mechanically multi-guided aluminum pistons for Approved to ATEX 94/9/EC Directive:
precise movement, low friction, and high cycle life. IIGD c T95°C for Standard and Low Temperature option
■ Machined teeth on piston racks and pinions for or IIGD c T150°C for the High Temperature option.
A111-5EN • 8/2011
excellent rack and pinion engagement and maximum * Except VPVL650, 700, 800
efficiency.
■ Extended temperature range option decreases
cycle life.
METSO A111-5EN
ACTUATOR SELECTION
To select an actuator for a particular valve and service, first valve. For spring-return units, both the spring torque and
determine the maximum operating torque that will be the air torque must be sufficient. In the event confirmation
required from the applicable valve bulletin.Then refer to the is desired for the selection of an actuator under specific
appropriate torque output table and select an actuator service conditions,include full details on trim,seat materials,
that will, at the available supply pressure, provide a torque and media characteristics.
output no less than the required operating torque for the
Opening Closing Swept Opening Closing Swept in. mm Opening Closing lb. kg
NOTES:
(1) The above times are based on the following conditions: A) Room temperature , B) Solenoid valve orifice diameter of 4 mm (5/32 in.) and a flow rate
capacity of 400 L/min (14.1 cfm), C) Minimum inner piping diameter of 8 mm (5/16 in.), D) 5.5 bar (80 psi) air supply pressure, E) Without valve loading.
DOUBLE ACTING
Actuator Torque Output in FT•LBS - VPVL XXDA Double-Acting Actuator at Specified psi Supply Pressures
Model 40 psi 50 psi 60 psi 70 psi 80 psi 90 psi 100 psi
VPVL 051 6.8 8.5 10.1 11.8 13.5 15.2 16.9
VPVL 100 12 14.9 17.9 20.9 23.9 26.8 29.8
VPVL 200 23.7 29.6 35 41 47 53 59
VPVL 250 37.2 46.6 55 65 74 83 93
VPVL 300 54 67.6 81 94 108 122 135
VPVL 350 87.5 109 131 153 175 197 219
VPVL 400 113 141 169 197 225 254 282
VPVL 450 177 221 265 310 354 398 442
VPVL 500 231 289 346 404 462 519 577
VPVL 550 312 390 467 545 623 701 779
VPVL 600 433 541 649 757 866 974 1082
VPVL 650 727 909 1091 1272 1454 1636 1818
VPVL 700 1055 1319 1583 1847 2111 2375 2638
VPVL 800 1833 2291 2749 3207 3665 4123 4581
Actuator Torque Output in N•m - VPVL XXDA Double-Acting Actuator at Specified bar Supply Pressures
Model 2.7 bar 3.5 bar 4.2 bar 4.8 bar 5.5 bar 6.2 bar 6.9 bar
VPVL 051 8.9 11.6 14 16 18.3 20.7 23
VPVL 100 16 20.5 24.6 28.1 32 36 40
VPVL 200 31 40 48 55 64 72 80
VPVL 250 48 66 79 90 103 117 130
VPVL 300 68 93 112 128 146 165 184
VPVL 350 115 150 181 207 236 266 296
VPVL 400 143 194 233 266 305 344 383
VPVL 450 224 304 365 417 478 539 600
VPVL 500 293 397 477 545 624 703 782
VPVL 550 395 536 643 735 842 949 1056
VPVL 600 575 745 893 1021 1170 1319 1468
VPVL 650 986 1232 1479 1725 1971 2218 2465
VPVL 700 1338 1815 2179 2490 2853 3216 3579
VPVL 800 2485 3106 3727 4348 4969 5590 6211
OPTIONS
Solenoid Valves allow the valve position to be set anywhere between full
closed and full open. This option limits travel of only the
Direct-mounted solenoid valves are available in both 3-way
counter-clockwise stroke for standard double-acting and
and 4-way configuration, which mount directly to the
spring-closed units. The 100% Adjustable Stop option is
actuator in accordance with NAMUR and VDI/VDE 3845
specified in the actuator ordering code.
standards, excluding the VPVL650, 700 and 800. In general,
3-way solenoids are used for spring-return actuators and 100% Travel Stop Lengths
4-way versions for double-acting. L Min L Max
Actuator
inch mm inch mm
Direct-Mount Solenoid Valves
VPVL051 6.2 158 7.3 186
Part Number 031-0576-01 031-0580-01
VPVL100 7.2 184 8.5 216
Enclosure NEMA IV NEMA VII
VPVL200 9.5 242 11.3 286
Configuration 3 or 4-way
VPVL250 11.0 280 13.0 330
Pipe Size 1/4" Inlet, 1/8" Exhaust
VPVL300 11.9 303 14.1 359
Cv 0.7
VPVL350 14.0 356 16.7 424
Voltage Standard: 120 VAC 60 Hz (110/50)
Optional: 240 VAC 60 Hz, 12 VDC, 24 VDC VPVL400 14.5 368 17.5 444
Body Material Black Anodized Aluminum VPVL450 17.7 449 21.1 537
Power Consumption AC: 6.9 watts or DC: 6.3 watts VPVL500 18.1 461 21.9 555
Humidity Resistant Feature rebreather and are suitable for VPVL550 20.9 531 24.8 631
humid & tropical environment VPVL600 24.7 628 29.1 739
VPVL650 25.7 653 30.9 785
NOTE: Please consult factory for other solenoid valves or additional options
VPVL700 30.0 762 36.1 918
including special voltages,double solenoids,special electrical connections,etc.
VPVL800 35.8 910 42.8 1086
Mechanical Safety Lockout
Lockout Kits
To comply with the intent of OSHA requirements for lock- VPVL051 LD98
ing actuators in position prior to performing maintenance, VPVL100 LD99
an actuator can have the mechanical safety lockout option VPVL200 LD100
added to it. Design of the stop cam allows for locking the VPVL250 LD101
actuator in either the full-open or full-closed position. VPVL300 LD102
Actuators equipped with this option have a special lockout VPVL350 LD103
screw and a tamperproof cover attached to the housing of VPVL400 LD104
the actuator with stainless steel wire. The lockout kits are VPVL450 LD105
readily available to permanently lock the actuator in place VPVL500 LD106
to prevent unwanted operation. VPVL550 LD107
VPVL600 LD108 Special longer bolt used to
100% Adjustable Travel Stop lock the actuator in one
VPVL650 LD109
To limit the rotation on the stroke beyond the standard VPVL700 LD110 position when needed.
VPVL actuator, a stainless steel 100%-adjustable travel stop VPVL800 LD111
option can be added. The stops, located in the end caps,
Stop Screw
Type A
VPVL051-300
L Min. Approx.
Stop Screw
Type B L Max. Approx.
VPVL350-800
DIMENSIONS
F B
C
J
D
E
Actuator
Mounting
Side
G S
Approximate Dimensions - mm
VPVL Actuator Declutchable
Approx.
Model Override
B C D E F G H J S Weight
(DA or SR) Kit
kgs.
VPVL250 and VPVL300 DO-1 146 175 142 60 115 37 227 200 12 10
VPVL350 and VPVL400 DO-2 195 241 154 63 143 53 261 200 15 18
VPVL450 and VPVL500 DO-3 222 282 190 84 160 63 270 300 20 23
VPVL550 and VPVL600 DO-4 250 326 228 107 172 60 338 500 20 38
VPVL650 and VPVL700* DO-5 276 367 258 127 190 68 366 900 25 64
VPVL800 DO-6 340 424 313 154 205 78 397 1000 25 91
* The VPVL700 DA unit may be used if the air pressure required to produce the needed output torque is lower than 6.5 bar.
DIMENSIONS
ØZ1 P
W
W1
B
CH Q1 Q
I = Depth of Square
A C
Bottom View ISO 5211
VPVL051 thru VPVL650
T PORT 4
ØZ1 P
R
PORT 2 D
S
B VPVL051 thru VPVL600
T PORT 4
A C S
VPVL700
PORT 2 D
R
ØZ1 P
VPVL650 thru VPVL800
4X4
(NOT APPLICABLE
M6 X 12 FOR VPVL051)
E
B
A C N G
VPVL800 F
VPVL100 6.04 3.35 3.33 M5 X 0.31 M5 X 0.31 3.15 1.18 0.43 0.79 1.26 0.94 1/8" 1.65 F05 + F07 1.97 2.76 M6 M8 0.55 0.63 3.5 3.7
VPVL200 8.01 4.02 3.66 M5 X 0.31 M5 X 0.31 3.15 1.18 0.67 0.79 1.26 0.94 1/8" 1.65 F05 + F07 1.97 2.76 M6 M8 0.55 0.63 6.0 6.8
VPVL250 9.49 4.53 4.06 M5 X 0.31 M5 X 0.31 3.15 1.18 0.67 0.79 1.26 0.94 1/8" 1.65 F05 + F07 1.97 2.76 M6 M8 0.75 0.83 8.2 9.5
VPVL300 10.20 5.00 4.67 M5 X 0.31 M5 X 0.31 3.15 1.18 0.67 0.79 1.26 0.94 1/4" 1.65 F07 + F10 2.76 4.02 M8 M10 0.75 0.83 11.5 13.4
VPVL350 11.97 5.71 5.39 M5 X 0.31 M5 X 0.31 3.15 1.18 1.06 1.18 1.26 0.94 1/4" 2.28 F07 + F10 2.76 4.02 M8 M10 0.87 0.94 17.6 20.5
VPVL400 13.11 6.18 5.79 M5 X 0.31 M5 X 0.31 3.15 1.18 1.06 1.18 1.26 0.94 1/4" 2.28 F07 + F10 2.76 4.02 M8 M10 0.87 0.94 21.6 25.8
VPVL450 15.53 6.97 6.54 M5 X 0.31 M5 X 0.31 3.15 1.18 1.06 1.18 1.26 0.94 1/4" 2.66 F10 + F12 4.02 4.92 M10 M12 1.06 1.38 31.3 38.4
VPVL500 16.63 7.72 7.13 M5 X 0.31 M5 X 0.31 3.15 1.18 1.06 1.18 1.26 0.94 1/4" 2.66 F10 + F12 4.02 4.92 M10 M12 1.06 1.38 39.9 49.2
VPVL550 18.66 8.68 7.87 M5 X 0.31 M5 X 0.31 5.12 1.18 1.42 1.97 1.26 0.94 1/4" 3.15 F14 5.51 5.51 M16 - 1.42 1.57 53.6 72.1
VPVL600 20.79 9.65 8.58 M5 X 0.31 M5 X 0.31 5.12 1.18 1.42 1.97 1.26 0.94 1/4" 3.15 F14 5.51 5.51 M16 - 1.42 1.57 75.2 92.4
VPVL650 23.82 11.75 10.16 M6 X0.39 M5 X 0.31 5.12 1.18 1.42 1.97 1.77 1.57 3/8" 4.53 F16 6.50 6.50 M20 - 1.81 1.89 116.2 148.4
VPVL700 27.95 12.99 12.56 M6 X0.39 M5 X 0.31 5.12 1.18 1.42 1.97 1.77 1.57 1/2" 4.53 F16 6.50 6.50 M20 - 1.81 1.97 163.1 205.0
VPVL800 34.49 16.14 16.46 M6 X0.39 M5 X 0.31 5.12 1.18 1.42 1.97 1.77 1.57 1/2" 4.53 F16 + F25 6.50 10.00 M20 M16 2.17 2.24 280.0 372.6
VPVL600 528.0 245 218 M5 X 8 M5 X 8 130 30 36 50 32 24 1/4" 80 F14 140 140 M16 - 36 40 34.1 41.9
VPVL650 605.0 299 258 M6 X10 M5 X 8 130 30 36 50 45 40 3/8" 115 F16 165 165 M20 - 46 48 52.7 67.3
VPVL700 710.0 330 319 M6 X10 M5 X 8 130 30 36 50 45 40 1/2" 115 F16 165 165 M20 - 46 50 74.0 93.0
7
METSO A111-5EN
65 17.3
17.2
06*
21* 17.1
19.5
19.6
60
17
07*
20*
HOW TO ORDER
To specify a complete Valv-Powr Value-Line® Actuator, simply make a selection from the code boxes below.
EXAMPLE: VPVL 400 SR4/5 B AS D, shown below, is a 59 FT•LBS 60-psi (84 N•m @ 4.2 bar) spring-return actuator with
spring-to-close rotation, hard-anodized PTFE-coated body, polyester-coated end caps, standard temperature rating, and
100% adjustable travel stops.
1 2 3 4 5 6 7
VPVL 400 SR4/5 B AS D —
NOTE: for multiple options, specify them in order as listed in Item 5, for example: VPVL400 SR4/5 B HT AS Model C.
7 Modifier Code
– Standard