Venturi Meter
Venturi Meter
DATE:
EXPERIMENT NO : 04
The most important class of the flow meter is that in which the flow is
either accelerated or retarded at the measuring sections by reducing the
flow area, and the change in the kinetic energy in measuring section by
reducing the flow area and the change in the kinetic energy is measuring
by recording the pressure difference produced.
5) The nozzle
Venturi meter
Like orifice meter, a venturi meter is also used for the measurement of
the discharge in pipeline. Since head loss cause due to the installation of
the venturi meter in a pipeline is less than that caused due to installation
of orifice meter, the former is usually preferred particularly for higher
flow rates. A venturi meter consists of a converging tube which is flowed
by diverging tube. The junction of two is termed as throat which is
section of minimum cross-section.
1
CHEMICAL ENGINEERING DEPARTMENT, SVMIT, BHARUCH
DATE:
Apparatus Description:
All the flow meters are mounted along pipeline with sufficient distance
to stabilize flow between two meters. The pressure taps are provided at
the section as given in the figure. The pressure head difference between
sections can be read on manometer having the mercury as the
manometer fluid. A valve, fitted at the end of the pipeline is used for
regulating the discharge in pipeline
Technical specifications:-
Venturimeter:
Size = 26mm
Throat size=16mm
Dia ratio =0.6
Experimental procedure:
2
CHEMICAL ENGINEERING DEPARTMENT, SVMIT, BHARUCH
DATE:
7)Close the drain valve of the collection tank and note down the initial
level of the water in the collection tank.
8)Collect known quantity of the water in the collection tank and note
down the time required for the same.
9)Change the flow rate of water through the meter with the help of
control valve and repeat the above procedure.
10)Take about 2-3 reading.
Observation:
For venturi meter
Diameter at inlet D1 =26mm; Area A1 = 5.31*10-4 m2
Diameter at throat D2 =16mm; Area A2 = 2.01*10-4 m
2
Sr No.
Manometer Difference in mm of hg Flow rate (time for
10lit) t in secs
1
2
3
Calculation:
3
CHEMICAL ENGINEERING DEPARTMENT, SVMIT, BHARUCH
DATE:
Put the value of Q and (h1-h2) from observations
Cd=
Conclusion:
Average value of the co-efficient of discharge for
Flow meter Discharge Co-efficient, Cd
Venturimeter