Site Development Plan: Perspective
Site Development Plan: Perspective
Site Development Plan: Perspective
00
produced of workable concrete. 30 Arch'l- 03,,, Architectural
3
21
4. REINFORCING STEEL BARS 00
Unless otherwise specified on plain, reinforcing 03.01 ,,, GRND.FLOOR PLAN
steel bars shall be deformed bars and in accordance
00
03.02 ,,, SECOND FLOOR PLAN
40
38
with the metal reinforcing requirements of standard
20 0
specifications on highways and bridges as adopted 00 0 03.03 ,,, SECTION THRU "A-A"
by the government. when placed in work, it shall be LAND USE & ZONING
00
free dirt, paints, spills of other foreign substance.
03.04 ,,, SECTION THRU "B-B"
34
0
5. WOOD FORMS: 20 03.05 ,,, FRONT ELEVATION
00
00
10
Wood forms shall be sound, good quality, free from 03.06 ,,, RIGHT SIDE ELEVATION
00
large loose knots and otherwise suitable to facilitate
16
GA
finishing exposed concrete as specified. 20 03.07 ,,, REAR ELEVATION
13
6. CURING: 0 03.08 ,,, LEFT SIDE ELEVATION
RA
Use water curing which shall be affected by keeping
GE
the forms at all times sufficiently wet with clean
00
water to prevent the joints in the forms of opening. 84 Arch'l- 04,,, Architectural
13
06
0
Concrete surface not protected by forms shall be
0
covering with craft paper quilts or burlaps. Protected 04.02 ,,, SCHEDULE OF DOORS
materials shall be kept thoroughly wet for the
04.03 ,,, T&B-PLAN
00
PO
7. EXCAVATIONS FOOTING AND 04.05 ,,,STAIRCASE 1 PLAN
BE
FOUNDATIONS:
R
04.06 ,,,CASE 2 PLAN
EN
CH
The bottoms of all excavations for footing and
DR
1
04.07 ,,,STAIRCASE 2 PLAN
RD
foundation which shall be undisturbed, earth
2
47
O
GA
OM
the Architect. Excavations shall be entirely free
from water during the pouring of concrete.
Struct'l - 01,,, Structural
T&
8. CONCRETE FLOORS AND STEPS
B
01.01 ,,, FOUNDATION PLAN
02
A IN
ON FILL OR ON GROUND:
D
LIV
R
Concrete from steps on fill shall be laid on prepared 30 01.02 ,,, SECOND FLR. FRAMING PLAN
EA G
foundation which shall be placed as follow: 00
LOT 26 BLOCK 14
R ID
The earth or sand fill shall be laid to a uniform 01.03 ,,, ROOF BEAM FRAMING PLAN
O
MA
OM 'S
grade below the excavation of the finished floors, 40 AREA = 201 SQ. M.
4
0 10 01.04 ,,, TYP. LINTEL BEAM DETAIL
being placed in the layers not exceeding 15cm in 0 0
thickness,its layer being thoroughly wetted and 0 01.05 ,,, SCHED. OF BEAM ARCHITECTURAL
tampered.The said fill shall be made as concrete
D
01.06 ,,, TYP. WALL FOOTING DETAIL
I
walls and foundation shall have sufficient strength.
02
10
NI
00
D
Concrete floor surface and other surface exposed 00
NG
21
after removed of forms shall be kept moist for a Struct'l - 02,,, Structural
period of at least 7 days after being placed. 20 40
00 5 0 02.01 ,,, COLUMN & FOOTING
PERSPECTIVE
All concrete placed during hot weather shall be
KI
protected from the rays of the sun and thoroughly PLANS & DETAILS
A
TC
wetted at least three times during the first 7 days. 02.02 ,,, WALL FOOTING DETAIL
KI IRT
H
1 02 SCALE 1:100 M.
0
9. FOUNDATIONS:
EN
02.03 ,,, SLAB DETAIL
0
T
37
34
D
C
All foundations shall be Class "A" (1:2:4) concrete 00
HE
mixture with the necessary reinforcement indicated 02.04 ,,,STAIR SECTION PLAN
in the plans. All zocalos shall be 0.15m thick
N
Y
02.05 ,,,TYPICAL RAFTER AND
0
concrete hollow blocks and shall be filled with
20
00
class "B"(1:3:5) mortar mixture with the necessary 1 67 CONCRETE GUTTER SECTION
30
10
50
24 STRUCTURAL
N
reinforcement as indicated in the plan.
0 0 Plum - 01,,, Plumbing
10. FLOORINGS: (See Schedule on Plan)
Unless otherwise noted on the plan, all flooring 01.01 ,,, GRND. FLR PLUMBING
shall be 0.10m thick concrete slab on fill on
00
compacted gravel with 10mmØ Temp bars spaced 23 LAY-OUT
45
at 0.50m on center bothways. 00 01.02 ,,,SECOND FLR. PLUMBING
11. WALLS: 40 LAY-OUT
All exterior and interior walls shall be of concrete 06
hollow blocks with the necessary reinforcement
0 0 01.03 ,,,UNDERTAKING
1
unless otherwise indicated in the plans. W E 01.04 ,,,PLUMBING SPECIFICATIONS
12. CEILING:
All ceiling boards shall be of 6mm thick ordinary
plywoodnon 0.05x1.05m ceiling joist spaced at
0.60m on center bothways.
A SITE DEVELOPMENT PLAN 37
3 0
Plum - 02,,, Plumbing
02.01 ,,,CATCH BASIN DETAIL
1 01 SCALE 1:100 M. 02.02 ,,,SEPTIC VAULT DETAIL
13. DOORS AND WINDOWS :
(See schedule on Plans) S
02.03 ,,,PLUMBING LEGENDS ELECTRICAL
14. CABINETS: 02.04 ,,,ISOMETRIC LAY OUT
All cabinets shall be of ordinary plywood. 02.05 ,,,PLUMBING ANALYSIS
All cabinet doors shall be a 12mm thick plywood
and louver as indicated in the follow-up design. Elect'l - 01,,, Electrical
15. ROOFING: TECHNICAL DESCRIPTION 01.01 ,,, GRND. FLR. LIGHTING
Unless otherwise noted on the plan, concrete SYSTEM LAY-OUT
.
0M
roofing shall be 0.15m thick and shall be applied of LINES BEARINGS DISTANCES 01.02 ,,,SECOND FLR. LIGHTING
AD
0.0
.-1
center bothways. °2 TE
L
O S
P
A
3'E
E
L
SI
Z
J
A O
BANKERS VIL LAGE
E G
.-2
SE N
R
°3
E
A
.B S I
EN
TH
NO E
35
3M
E
WE
N.
ST
1-2 N.54°23'W.
Parks
ER
.
and
Playground SIO
NR
SYSTEM LAY-OUT
A
OA R
D
LOT 26,BLOCK 14
E
WESTWOODS SUBDIVISION
S
10.00 M.
U T.
N.35°37'E
A
S
2-3
R
17. PAINTINGS:
T
E
O
SANITARY
D
201 S.Q.M.
O
R
S
A
SYSTEM LAY-OUT
T.
J
A
F
20.13 M.
PLAZA
MANDURRIAO
01.06 ,,,RISER DIAGRAM
0.0
M.
01.07 ,,,SPICICATION
7'W
TAFT STREET
Y
18. ELECTRICAL:
A
ABETO STREET
W
N
°3
PLAZA
U
R
W E
ILOILO
AIRPORT
Elect'l - 02,,, Electrical
S.
A-1
STRUCTURAL ENGINEER contract documents duly signed, stamped or sealed, as instruments of service,
PROPOSED TWO STOREY OFFICE
OFFICE BUILDING
BUILDING MRS. EVE ENOJAS
are the intellectual property and documents of the architect, whether the object
for which they are made is executed or not. It shall be unlawful for any person
PERSPECTIVE, VICINITY MAP, &
REG. NO.: 67660 PLACE: ILOILO CITY TIN #: to duplicate to make copies of said documents for use in the repetition of and LOT DESCRIPTION
CLASSY & COMFORTABLE PTR NO.: APPROVED
for other projects or buildings, whether executed partly or in whole, without the
written consent of architect or author of said documents.
U N I QU E H OME S 5684473 DATE: 01/03/18 158-702-854 LOCATION : SAN DONISIO, ILOILO
REPUBLIC OF THE PHILIPPINES
A B B1 C
A B B1 C 6 5 4 3 2 1A 1
D P W H
10000
2500 2500 2500 2500 OFFICE OF THE BUILDING OFFICIALS
300 2050 300 2200 300 2200 300 300
150
FWF FWF FWF FWF ILOILO CITY
FF1 FF1 FF1 FF1
2576
2876
FWF
FIREWALL
300
FC1 FF1 DIRTY
KITCHEN
W
2576
2876
2
1 4000 3730
FWF
D
02
3698
1A
MAID'S
300
D
FC1 FF1 KITCHEN ARCHITECTURAL
2000
02
1500
1500
1500
1500
ROOM
800
2
2576
2876
FWF
T&B 1975 1825 3001000300 2300 2300
300
FC1 FF1
FENCE FRONT ELEVATION FENCE RIGHT SIDE ELEVATION
D
03
A A
3 DINING
2 04 SCALE 1:100 M.
20130
SCALE 1:100 M.
2576
2876
2 02
FWF
BEDROOM
300
FC1 FF1
1 C B1 B A 1 1A 2 3 4 5 6
LIVING
FWF
4 AREA
PORCH
5
8177
FWF
GARAGE
6
FF1
FWF
500
GARDEN
FWF
1700
12930 3000
FF1 FF1
3700
3700
FF1 FWF
300
1500
1500
1500
FC2 FC2 FC2 FC1 1500
3800 3001000300 4600
3950 1300 4750
E
10000 20130
N
150 650
NATURAL GRADE LINE
NATURAL GRADE LINE
800
600
3-10mm Ø RSB 3-12mm Ø RSB CONT. BARS
650
650
800
200
TIES @ 50mm O.C.
300
150
150
Fence Column/Footing Fence Column/Footing Fence Column/Footing Fence Wall Footing Fence Wall Footing
A FC1/FF1-PLAN A FC2/FF1-PLAN A FC1/FF1-SECTION A FWF-PLAN A FWF-SECTION
2 06 SCALE: 1:20M 2 07 SCALE: 1:20M 2 08 SCALE: 1:20M 2 09 SCALE: 1:20M 2 10 SCALE: 1:20M
CERTIFIED BY : PROJECT TITLE : OWNER : REPUBLIC ACT 9266: SHEET CONTENTS: SHEET NO.:
ENGR. NEIL EDWIN R. ESCALONA Article 4 section 33 , stipulates that all drawings and specifications and other
PERIMETER FENCE LAYOUT,
A-2
STRUCTURAL ENGINEER contract documents duly signed, stamped or sealed, as instruments of service,
MR. ERNIE ENOJAS & are the intellectual property and documents of the architect, whether the object
FRONT & RIGHT SIDE ELEVATION,
PROPOSED TWO STOREY OFFICE BUILDING MRS. EVE ENOJAS for which they are made is executed or not. It shall be unlawful for any person
REG. NO.: 67660 PLACE: ILOILO CITY TIN #: to duplicate to make copies of said documents for use in the repetition of and FENCE COL./FOOTING DET., &
CLASSY & COMFORTABLE PTR NO.: APPROVED
for other projects or buildings, whether executed partly or in whole, without the
written consent of architect or author of said documents.
FENCE WALL FOOTING DETAILS
U N I QU E H OME S 5684473 DATE: 01/03/18 158-702-854 LOCATION : SAN DONISIO, ILOILO
REPUBLIC OF THE PHILIPPINES
A B B1 C
10000 A A1
10000
B B1 C
APEX LINE
6 5 4 3 2 1A 1 D P W H
2100 3400 4500
OFFICE OF THE BUILDING OFFICIALS
2100 3400 4500
600 1300
TOP OF BEAM
2900 1600
ILOILO CITY
3130
3730
3730
4330
MASTER'
S
3000
B B BEDROOM BEDROOM
3
8600
DIRTY LOBBY D D
KITCHEN BALCONY SECOND FLOOR LEVEL 02 03
400 1200
W W
400600
400600
4 3
1 W
1
400
2 D
02 D
04
1A 1A
3200
MAID'S D LIVING
2300
2300
2300
2300
02 KITCHEN WALK DINING
MASTER'
S
3700
ROOM W T&B N
I D AREA
D D D
5 03 BEDROOM GROUND FLR. LEVEL 01 03 02 ARCHITECTURAL
2 2
500
SIDE WALK LEVEL
6750
T&B
D
2400
2400
2400
2400
A A A A SECTION THRU "B-B"
W 02
2
W
5 D A
03 3 08 SCALE 1:100 M.
3 3
3050
D DINING LOBBY T&B
20130
20130
20130
20130
02
D
02 D
03
3700
3700
3700
3700
W
2 BEDROOM W
BEDROOM
2
1 2
C B1 B A A B B1 C
APEX LINE
LIVING +8.60
OPEN
4050
4050
D
4 4
600 1300
PORCH
2000
2000
2000
2000
D
01 BEDROOM +6.70 TOP OF BEAM
4200
5 5 3
W W
1000
1000
W W
1 1 1 1 CANOPY
W
2000
MASTER'
S
3000
GARAGE 7 W
500600 1500
1000
B 6 BEDROOM STAIR
6 6
8600
D
5000
5000
W W
02
6 +3.70 SECOND FLOOR LEVEL
GARDEN B 7
4000
4000
FIXED GLASS W/
3000
3000
3000
AWNING WINDOW
3200
T&B
3200
DINING 50x50mm U-CUT
1300 3200 W W
GARAGE 1 1 +0.50 GROUND FLR. LEVEL
3800 1600 4600 4700
500
±0.00 SIDE WALK LEVEL
E
E
S
10000 10000
A SECTION THRU "A-A" A FRONT ELEVATION
N
1 1A 2 3 4 5 6 C B1 B A 6 5 4 3 2 1A 1
APEX LINE APEX LINE
+8.60
600 1300
TOP OF BEAM +6.70 TOP OF BEAM
CANOPR CANOPY
STAINLESS STEEL SLIDING DOOR
3000
RAILING W
W 7 STAINLESS STEEL
5
RAILING
8600
8600
8600
W W W
SECOND FLOOR LEVEL 2 2 3 SECOND FLOOR LEVEL FIREWALL
+3.70
D
04
CANOPY
3200
SLIDING WINDOW
600
W
5 W
DOOR PANEL
1500
W 4 W
1500
1500
GROUND FLR. LEVEL 2 D 2 GROUND FLR. LEVEL
01 +0.50
500
SIDE WALK LEVEL D SIDE WALK LEVEL
02
±0.00
CERTIFIED BY : PROJECT TITLE : OWNER : REPUBLIC ACT 9266: SHEET CONTENTS: SHEET NO.:
ENGR. NEIL EDWIN R. ESCALONA Article 4 section 33 , stipulates that all drawings and specifications and other GROUND FLOOR PLAN &
A-3
STRUCTURAL ENGINEER contract documents duly signed, stamped or sealed, as instruments of service,
MR. ERNIE ENOJAS & SECOND FLOOR PLAN, FRONT
PROPOSED TWO STOREY OFFICE BUILDING are the intellectual property and documents of the architect, whether the object
REG. NO.: 67660 PLACE: ILOILO CITY TIN #: MRS. EVE ENOJAS for which they are made is executed or not. It shall be unlawful for any person ELEVATION, RGIHT SIDE ELEV.,
to duplicate to make copies of said documents for use in the repetition of and
CLASSY & COMFORTABLE for other projects or buildings, whether executed partly or in whole, without the LEFT SIDE ELEV., REAR ELEV.,
U N I QU E H OME S PTR NO.: 5684473 DATE: 01/03/18 158-702-854 LOCATION : SAN DONISIO, ILOILO APPROVED written consent of architect or author of said documents. SECTION THRU "A-A" & "B-B"
REPUBLIC OF THE PHILIPPINES
D P W H
OFFICE OF THE BUILDING OFFICIALS
ILOILO CITY
3300
1200
1200
1200
Handrail
ARCHITECTURAL
900
900
2nd. Flr. Ln. 2nd. Flr. Ln. 1200 1200
1653
1653
600
753
5538
313
Ceiling Ln.
Vertical Clearance
690
690
1000 2100
Handrail 700
2035
T&B
250
2447
Ceiling Ln.
2685
2372
1996
1996
S S F
900
2100
2100
2100
2100
Grd. Flr. Ln. Grd. Flr. Ln.
1050
1050
1050
1050
A SECTION THRU "AA" A SECTION THRU "BB" 1
QUANTITY : 1 SET
LOCATION : ENTRANCE 2
QUANTITY : 6 SETS
LOCATI
ON
BED
: ROOMS 3
QUANTITY : 3 SETS
LOCATION : T & B 4
QUANTITY : 1 SET
LOCATION : BALCONY
4 03 SCA LE 1:50 M. 4 05 SCA LE 1:50 M. 1000
DESCRIPTION : SOLID CORE DESCRIPTION : SOLID CORE DESCRIPTION : HOLLOW CORE DESCRIPTION : SLIDING GLASS DOOR
PANEL TYPE DOOR PANEL TYPE DOOR W/ LOUVER
F SCHEDULE OF DOORS
1425
A
4 06 SCALE 1:50 M.
B B
1350 2250 300 1200 300x7=2100
1400
F 1500
575 425 1050
5200
750 750 1200 1200 600 800
1200
483
750
A A A A S S SS
600
S S
483
S S
900
1200
1200
F
1500
F F
1500
750
483
1500
1200
900
900
F
875
600
600
1200 900 fin.flr. line fin.flr. line fin.flr. line fin.flr. line fin.flr. line fin.flr. line fin.flr. line
1250 486 2164
W QUANTITY : 2 SETS W QUANTITY : 4 SETS W QUANTITY : 1 SET W QUANTITY : 1 SET W QUANTITY : 2 SETS W QUANTITY : 1 SET W QUANTITY : 1 SET
B 1 LOCATI
ON
LI
VI
:NG 2 LOCATI
ON
BEDROOMS
: 3 LOCATI
ON
M
: ASTER'
S 4 LOCATI
ON
K:TCHEN
I 5 LOCATI
ON
T&B
:
6 LOCATI
ON
BEDROOM
: 3
7 LOCATI
ON
BEDROOM
: 3
B
DESCRI
PTI
ON
FI
XED
: GLASS DESCRI
PTI
ON
SLI
:DI
NG
WI
NDOW DESCRI
PTI
ON
SLI
:DI
NG DESCRI
PTI
ON
SLI
:DI
NG DESCRI
PTI
ON
SLI
:DI
NG DESCRI
PTI
ON
FI
XED
: GLASS DESCRI
PTI
ON
FI
XED
: GLASS
W/
AWNI
NG
WI
NDOW WI
NDOW WI
NDOW WI
NDOW WI
NDOW W/
AWNI
NG
WI
NDOW
A Grd flr STAIRCASE 2 - PLAN A 2nd flr STAIRCASE 2 - PLAN A SCHEDULE OF WINDOWS
4 01 SCALE 1:50 M. 4 02 SCALE 1:50 M. 4 07 SCALE 1:50 M.
CERTIFIED BY : PROJECT TITLE : OWNER : REPUBLIC ACT 9266: SHEET CONTENTS: SHEET NO.:
ENGR. NEIL EDWIN R. ESCALONA Article 4 section 33 , stipulates that all drawings and specifications and other
SCHEDULE OF DOORS &
A-4
contract documents duly signed, stamped or sealed, as instruments of service,
STRUCTURAL ENGINEER MR. ERNIE ENOJAS &
PROPOSED TWO STOREY OFFICE BUILDING are the intellectual property and documents of the architect, whether the object
WINDOWS, STAIRCASE DETAILS, &
REG. NO.: 67660 PLACE: ILOILO CITY TIN #: MRS. EVE ENOJAS for which they are made is executed or not. It shall be unlawful for any person
to duplicate to make copies of said documents for use in the repetition of and T&B DETAILS
CLASSY & COMFORTABLE PTR NO.: APPROVED
for other projects or buildings, whether executed partly or in whole, without the
written consent of architect or author of said documents.
U N I QU E H OME S 5684473 DATE: 01/03/18 158-702-854 LOCATION : SAN DONISIO, ILOILO
A B B1 C A B B1 C A B B1 C
1439 661 3400 1300 3200 1439 661 3400 1300 3200 2100 3400 1300 3200
3780
3780
4185
4185
2"x4" C-PURLINS @
S1 500mm O.C.
C1/F1 WF <125>
950
950
1 FTB 1 1
550
550
400
400
B1 GUTTER
C2/F1 WF
1A WF 1A B1 1A GUTTER RB
RB
2700
2700
2700
2700
C1/F1
2300
2300
S1
B1
B1
RB
<125>
S1
FTB <125>
2 2 B1 2 RB
WF 1300
RB
C1/F1 C1/F1 C1/F1 RB
2400
2400
2400
2400
2400
2800
B1
STAIR B1
RAFTER
RAFTER
RAFTER
RAFTER
RAFTER
RAFTER
RAFTER
WF
3 3 3
2850
S1
B1
B1 S1 <125>
RB
<125>
1850
12600
12600
1450
12800
12800
12800
12800
C1/F1 C1/F1 C1/F1 RB
RB
3700
3700
S1
3700
3700
B1
B1
<125>
B1 gutter GUTTER
WF 2"x4" C-PURLINS @
S1
1850
1887
<125>
500mm O.C.
FTB
OPEN
RAFTER
RAFTER
RAFTER
RAFTER
4 4 4
B1
WF B1 B1 BELOW
C1/F1
2000
2000
2000
2000
2000
C1/F1 C1/F1
RB
RB
B1
S1
2963
WF RB
FTB
RB
<125>
RAFTER
RAFTER
RAFTER
RAFTER
5 5 B1 5
800 1000
FTB B1 RB
2000
2000
2000
2000
C1/F1 C1/F1
800
FTB
gutter RB
1555
GUTTER
6 6 6
550
B1
C1/F1
2450
2445
E
E
2100 3400 1300 3200 2100 3400 1300 3200 2100 3400 1300 3200
S
S
10000 10000 10000
N
N
N
W
W
W
CERTIFIED BY : PROJECT TITLE : OWNER : REPUBLIC ACT 9266: SHEET CONTENTS: SHEET NO.:
ENGR. NEIL EDWIN R. ESCALONA Article 4 section 33 , stipulates that all drawings and specifications and other FOUNDATION PLAN,
S-1
STRUCTURAL ENGINEER contract documents duly signed, stamped or sealed, as instruments of service,
MR. ERNIE ENOJAS & FLOOR FRAMING PLAN, &
PROPOSED TWO STOREY OFFICE BUILDING are the intellectual property and documents of the architect, whether the object
REG. NO.: 67660 PLACE: ILOILO CITY TIN #: MRS. EVE ENOJAS for which they are made is executed or not. It shall be unlawful for any person
to duplicate to make copies of said documents for use in the repetition of and
ROOF FRAMING PLAN
CLASSY & COMFORTABLE PTR NO.: APPROVED
for other projects or buildings, whether executed partly or in whole, without the
written consent of architect or author of said documents.
U N I QU E H OME S 5684473 DATE: 01/03/18 158-702-854 : LOCATION : SAN DONISIO, ILOILO
NOTE: fc' = 3,000 psi (20.70 MPa)
SCHEDULE OF SLABS : RSB: 20MM & BELOW (Gr. 33)
25MM & ABOVE (Gr. 40)
BOTTOM BARS T O P B A R S (BENT - UP BARS)
175
25MM MIN.
CONCRETE COVER
175
16MMØ @ 200 O.C.
SLAB Thick
(mm)
RSB
(mm) Short Span Long Span Short Span
Midspan Column Strip Midspan Column Strip Midspan Column Strip Midspan Column Strip
Long Span REMARKS SCHEDULE OF FOOTINGS
X (width) Y (length) REBARS ALONG X REBARS ALONG Y
LANDING SLAB FOOTING T (mm) D (mm)
S1 125 10 125 250 125 250 250 125 250 125 TWO WAY (mm) (mm) PCS BAR Ø PCS BAR Ø
TOP BARS
CS 125 10 150 300 150 300 300 150 300 150 ONE WAY
400
400
STIRRUPS F1 1500 1500 300 1200 9 16 MM 9 16 MM
@250MM O.C.
L/4
RB 200 400 12 33 4 2 2 4 - 10 mm 4@50, 4@100, Rest@ 200
GRAVEL FILL FTB 200 400 12 33 3 3 3 3 - 10 mm 4@50, 4@100, Rest@ 200
187.50
FGL
CANOPY
VARIABLE
500
L/2
12
680
4 PCS 12MMØ
L/4
@ 200MM OC BW
S STRUCTURAL STAIR DETAIL BEAM
2 01 SCALE 1:20 M.
150
VARIABLE
B O T T OB M
ARS
SCHEDULE OF COLUMNS
10mmØ straight matting bars sp.
SECTION
@ 300mm o.c. b.w.
L/4
400
400
200
ns)
42
url i
C-P
6"
L/2
"x
-2
125
REBARS: REBARS: REBARS:
6 PCS. - 16 MMØ 6 PCS. - 16 MMØ 6 PCS. - 16 MMØ PCS
PURLINS
R (2
@ 500 MM OC E
TIES: 10 MM Ø (1 SET) TIES: 10 MM Ø (1 SET) TIES: 10 MM Ø (1 SET) AFT 2 PCS - 2" x 6" C-PURLINS
6@50, 6@100, REST 6@50, 6@100, REST 6@50, 6@100, REST
R (JEA MAXX, 1.50 MM THK)
10mmØ temp bars
@150 TO MIDHEIGHT @150 TO MIDHEIGHT @150 TO MIDHEIGHT
RAFTER DETAIL
L/4
@ 300mm o.c. b.w.
S
2 02 SCALE NTS
COLUMN 1 PLANTED COLUMNS COLUMN 2
TOP BARS
100 VARIES 67 67
2 BARS STRAIGHT/CONTINUOUS
PURLINS
GA. 26 PRE-PAINTED S SLAB DETAIL
L/3 (TOP BARS) L/3 B 20MM MIN. B LONG SPAN ROOFING 2 06 SCALE 1:40 M.
VARIES
CONC COVER OR APPROVED EQUIVALENT
BARS CUT (@SUPPORT) 2-10MMØ BARS
2 PCS - 2"x 6"x (1.5MM THK)
TOP BARS 150MM CONCRETE C-PURLINS RAFTER
STIFFENER BAR PARAPET WALL
±110
STIRRUPS CONC.
4-12MMØ BARS GUTTER
400
STIFFENER BARS BUNDLED IN 2's
D
STIRRUPS
SPACING
100
10MMØ STIRRUPS CEILING (INTERIOR)
2 BARS STRAIGHT/CONTINUOUS 3@ 50MM, REST
(BOTTOM BARS) BOTTOM BARS @ 150MM RB
L/4 L/4
ADDITIONAL BOTTOM SEE ROOF BEAM
BARS CUT (@MIDSPAN) @ SUPPORT @ MIDSPAN
SPAN (L)
NOTE: NO SPLICE SHALL BE PERMITTED
S CONCRETE GUTTER DETAIL
S TYPICAL BEAM DETAIL AT MIDSPAN FOR BOTTOM BARS
OR NEAR THE SUPPORTS FOR TOP BARS
MIN. SPLICE LENGHT: 40 X BAR DIAM.
2 05 SCALE 1:15 M.
2 04 SCALE NTS
CERTIFIED BY : PROJECT TITLE : OWNER : REPUBLIC ACT 9266: SHEET CONTENTS: SHEET NO.:
ENGR. NEIL EDWIN R. ESCALONA Article 4 section 33 , stipulates that all drawings and specifications and other SCHEDULE OF FOOTINGS, SCHEDULE OF
S-2
STRUCTURAL ENGINEER
PROPOSED TWO STOREY OFFICE BUILDING MR. ERNIE ENOJAS & contract documents duly signed, stamped or sealed, as instruments of service,
are the intellectual property and documents of the architect, whether the object
COLUMNS, SCHEDULE OF SLABS,
STRUCTURAL STAIR DETAILS, RAFTER
REG. NO.: 67660 PLACE: ILOILO CITY TIN #: MRS. EVE ENOJAS for which they are made is executed or not. It shall be unlawful for any person
to duplicate to make copies of said documents for use in the repetition of and DETAIL, CONCRETE CANOPY DETAIL,
CLASSY & COMFORTABLE PTR NO.: APPROVED
for other projects or buildings, whether executed partly or in whole, without the
written consent of architect or author of said documents.
TYPICAL BEAM DETAIL, SLAB DETAIL, &
UNI QUE HOMES 5684473 DATE: 01/03/18 158-702-854 LOCATION : SAN DONISIO, ILOILO
CONCRETE GUTTER
3/4'' Ø uPVC PIPE
HB
SW
PUMP
DIRTY DIRTY
KITCHEN KS BALCONY KITCHEN BALCONY
FAU WATER
CB CB CB FD
DS CO DS DS DS 3/4'' Ø uPVC PIPE TANK
CB CB
LIVING OPEN LIVING OPEN
AREA BELOW AREA BELOW
PORCH PORCH
BEDROOM BEDROOM
3 3
CO
CO
GARAGE GARAGE HB
GV
HB
M
3/4'' Ø uPVC PIPE
P GROUND FLOOR PLAN P SECOND FLOOR PLAN P GROUND FLOOR PLAN P SECOND FLOOR PLAN
1 01 SCALE: 1:100 M. 1 02 SCALE 1:100 M. 1 03 SCALE 1:100 M. 1 04 SCALE 1:100 M.
CERTIFIED BY : PROJECT TITLE : OWNER : REPUBLIC ACT 9266: SHEET CONTENTS: SHEET NO.:
ERMAN G. GANGE Article 4 section 33 , stipulates that all drawings and specifications and other
GRD. & 2ND FLR.SANITARY LAYOUT,
P-1
MASTER PLUMBER contract documents duly signed, stamped or sealed, as instruments of service,
PROPOSED TWO STOREY OFFICE BUILDING MR. ERNIE ENOJAS & are the intellectual property and documents of the architect, whether the object GRD. & 2ND FLR. WATER LINE LAYOUT,
REG. NO.: 2187 PLACE: ILOILO CITY TIN #: MRS. EVE ENOJAS for which they are made is executed or not. It shall be unlawful for any person PLUMBING SPECIFICATION,
to duplicate to make copies of said documents for use in the repetition of and
PLUMBING LEGENDS, AND
CLASSY & COMFORTABLE PTR NO.: APPROVED
for other projects or buildings, whether executed partly or in whole, without the
written consent of architect or author of said documents. UNDERTAKING
U N I QU E H OME S 5811778 DATE: 01/05/18 183-771-266 : LOCATION : SAN DONISIO, ILOILO
M PM WM
M M
C11 C12
BALCONY BALCONY
I' I'
L
TEL ACU
S2,N,O G' I' REF CAB
M C3
S2,J',K' MAID'S C16
MAID'SO KITCHEN C6 KITCHEN WALK
N K K K' J'WALK
H'MASTER'S ROOM C7 C13 T&B MASTER'S
ROOM T&B IN RANGE IN
BEDROOM BEDROOM
C19
J
J S2,J,K C14
A' G' I'
P C1 S3,G,H,I
S2,L,M S3,G',H',I'
I
S2,P,Q I
Q R'
F A' B' C' C9
S2,B',C'
DINING H' S3W,A' T&B DINING T&B
S2,R,S F LOBBY C17 LOBBY
C5 C10
L' L' S2,R',S' S' ACU
R R B' C' C8
M G G
S2,L',M' S2,D',E',F' C15
E BEDROOM BEDROOM
B'
C2 M' 2 M'
D' D' TEL TV 2
S S S2,A,B ACU
S2,C,D E'
S2,E,F LIVING OPEN LIVING OPEN
F'
E AREA S2,N',O' C4 BELOW
WP AREA BELOW
PORCH S2,P',Q' PORCH
D O'
D O'
D' D' BEDROOM
BEDROOM C18
3 3
N' N' Q' Q' ACU
C GARAGE C
GARAGE
P'
A B B
A
CERTIFIED BY : PROJECT TITLE : OWNER : REPUBLIC ACT 9266: SHEET CONTENTS: SHEET NO.:
ENGR. IAN JAN R. HERNANDO Article 4 section 33 , stipulates that all drawings and specifications and other GROUND FLOOR LIGHTING LAYOUT,
SECOND FLOOR LIGHTING LAYOUT, &
E-1
PROFESSIONAL ELECTRICAL ENGINEER (P.E.E.) contract documents duly signed, stamped or sealed, as instruments of service,
PROPOSED TWO STOREY OFFICE BUILDING MR. ERNIE ENOJAS & are the intellectual property and documents of the architect, whether the object
GRD. FLR. POWER SYSTEM LAYOUT, &
REG. NO.: 2588-19 PLACE: ILOILO CITY TIN #: MRS. EVE ENOJAS for which they are made is executed or not. It shall be unlawful for any person
to duplicate to make copies of said documents for use in the repetition of and 2ND FLR. POWER SYSTEM LAYOUT
CLASSY & COMFORTABLE PTR NO.: APPROVED
for other projects or buildings, whether executed partly or in whole, without the
written consent of architect or author of said documents.
U N I QU E H OME S 5784187 DATE: 01/03/18 126-174-513 LOCATION : SAN DONISIO ILOILO
SPECIFICATIONS ELECTRICAL SYMBOLS DESIGN ANALYSIS
ALL WORKS SHALL CONFORM WITH THE LATEST EDITION OF THE PHILIPPINE PB MAIN PANEL BOARD C1 LIGHTING LOADS C9 CONVENIENT OUTLETS
ELECTRICAL CODE, THE RULES AND REGULATIONS OF THE LOCAL ENFORCING 84 I= 12(7VA) ÷ 220V= 0.38 A 1080 l= 6(180VA)÷220V= 5.00A
CIRCUIT BREAKER Ic= 0.48A
Ic= 5.12A
AUTHORITIES OF THE CITY OF ILOILO AND THE REQUIREMENTS OF PANAY USE: 2- 3.5MM² THHN Cu. WIRE ; 15MMØ PVC CONDUIT USE: 2- 3.5MM² THHN Cu. WIRE, 15MMØ PVC CONDUIT
KWHR METER 15AT,240V, 2P, 60HZ, 1Ø ITD CB 20AT,240V, 2P, 60HZ, 1Ø ITD CB
ELECTRIC COOPERATIVE. C2 LIGHTING LOADS C11 PUMP MOTOR LOAD
22 w 22 WATT PINLIGHT 105 I= 15(7VA) ÷ 220V= 0.48 A 1200 l = 5.50 A
NATURE OF SERVICE SHALL BE 220V., 1 Ø, 60 HZ, AND 2 WIRE. Ic= 0.6A Ic = 6.90A
WH WATER HEATER USE: 2- 3.5MM² THHN Cu. WIRE ; 15MMØ PVC CONDUIT USE: 2- 3.5MM² THHN Cu. WIRE, 15MMØ PVC CONDUIT
TYPE OF WIRING SHALL BE IN THWN IN METALLIC FOR SERVICE ENTRANCE 15AT,240V, 2P, 60HZ, 1Ø ITD CB 30AT,240V, 2P, 60HZ, 1Ø ITD CB
S SINGLE SWITCH
AND THHN FOR BRANCH CIRCUIT EMBEDDED IN CONCRETE WALLS, FLOORS
C3 LIGHTING LOADS C12 WASHING MACHINE LOAD
56 I= 8(7VA) ÷ 220V= 0.25 A 1200 l = 500 VA/ 220 V =1.14 A
S3W 3-WAY SWITCH 96 I= 12(7VA) +CHAN÷220V= 2.00 A 900 l = 250 VA / 220 V= 1.14A
SERVICE ENTRANCE Ic= 2.5A Ic = 1.43A
FEEDER LINE USE: 2- 3.5MM² THHN Cu. WIRE ; 15MMØ PVC CONDUIT
15AT,240V, 2P, 60HZ, 1Ø ITD CB
USE: 2- 3.5MM² THHN Cu. WIRE, 15MMØ PVC CONDUIT
20AT,240V, 2P, 60HZ, 1Ø ITD CB
SPECIAL OUTLET 2 - 3.5 SQ. MM. THHN. CU. WM WASHING MACHINE USE: 2- 3.5MM² THHN Cu. WIRE ; 15MMØ PVC CONDUIT
15AT,240V, 2P, 60HZ, 1Ø ITD CB
USE: 2- 3.5MM² THHN Cu. WIRE, 15MMØ PVC CONDUIT
30AT,240V, 2P, 60HZ, 1Ø ITD CB
C15,C16,C17,C18 ACU LOAD
MOUNTING HEIGHT SHALL NOT BE LESS THAN AS FOLLOWS : CIRCUIT LINE C6
70
LIGHTING LOADS
I= 10(7VA) ÷ 220V= 0.32 A 1760 l = 8.0 A
Ic= 0.4A Ic = 10.0A
DUPLEX RECEPTACLE OUTLET 0.40 M. ABOVE FINISH FLOOR LINE WP WEATHER PROOF
USE: 2- 3.5MM² THHN Cu. WIRE, 15MMØ PVC CONDUIT USE: 2- 3.5MM² THHN Cu. WIRE, 15MMØ PVC CONDUIT
Ic= 5.12A
FOR MAIN CIRCUIT PROTECTION;
IT =105.38 +2.0A =107.38 A
REF REFRIGERATOR USE: 2- 3.5MM² THHN Cu. WIRE, 15MMØ PVC CONDUIT USE : 2-38MM² THHN Cu WIRE + 1- 8.0MM² sq. THHN Cu GRNDG.
ALL WORKS SHALL BE DONE UNDER THE DIRECT SUPERVISION OF A DULY 20AT,240V, 2P, 60HZ, 1Ø ITD CB 40mmØ pvc conduit
DISTRIBUTION UTILITY
COMPANY
220 VOLTS, SCHEDULE OF LOADS: 220V, 2P, 60Hz, 1Ø, 2-WIRE+ 1- GRN; LINE-LINE UNDERGROUND SYSTEM
1Ø, 60 Hz AC MAINS CIRCUIT NO. LOAD DESCRIPTION NO. OF OUTLETS NO. SWITCHES CKT. VOLTS/ TYPES & SIZE OF
3No. 5.5mm² THHN Cu. VA AMPS BREAKERS SIZE OF CONDUIT
L.O. C.O. OTHERS S1 S2 S3 S3W PHASE CONDUCTOR
125AT,2P
1 LIGHTINGS 12 84 0.38 15 AT,2P 220V1Ø 2No. 3.5mm² THHN Cu. 15mmØ pvc conduit
2 LIGHTINGS 15 105 0.48 15 AT,2P 220V1Ø 2No. 3.5mm² THHN Cu. 15mmØ pvc conduit
2No. 3.5mm² THHN Cu. 2No. 3.5mm² THHN Cu. 3 8 56 0.25 15 AT,2P 220V1Ø 2No. 3.5mm² THHN Cu. 15mmØ pvc conduit
C1 C2
LIGHTINGS
LIGHTINGS LIGHTINGS 4 LIGHTINGS 12+CHAN 434 2.00 15 AT,2P 220V1Ø 2No. 3.5mm² THHN Cu. 15mmØ pvc conduit
2No. 3.5mm² THHN Cu. 2No. 3.5mm² THHN Cu. 5 LIGHTINGS 11 77 0.35 20 AT,2P 220V1Ø 2No. 3.5mm² THHN Cu. 15mmØ pvc conduit
LIGHTINGS C3 C4 LIGHTINGS 6 LIGHTINGS 10 70 0.32 20 AT,2P 220V1Ø 2No. 3.5mm² THHN Cu. 15mmØ pvc conduit
2No. 3.5mm² THHN Cu. 2No. 3.5mm² THHN Cu. 7 CONV. OUTLET 4 720 3.30 20 AT,2P 220V1Ø 2No. 3.5mm² THHN Cu. 15mmØ pvc conduit
LIGHTINGS C5 C6 LIGHTINGS 8 CONV. OUTLET 5 900 4.10 20 AT,2P 220V1Ø 2No. 3.5mm² THHN Cu. 15mmØ pvc conduit
9 CONV. OUTLET 6 1080 5.00 30 AT,2P 220V1Ø 2No. 3.5mm² THHN Cu. 15mmØ pvc conduit
2No. 3.5mm² THHN Cu. 2No. 3.5mm² THHN Cu.
CONV. OUTLETS C7 C8 CONV. OUTLETS 10 CONV. OUTLET 5 900 4.10 30 AT,2P 220V1Ø 2No. 3.5mm² THHN Cu. 15mmØ pvc conduit
11 PUMP MOTOR 1 1200 5.50 30 AT,2P 220V1Ø 2No. 5.5mm² THHN Cu. 15mmØ pvc conduit
2No. 3.5mm² THHN Cu. 2No. 3.5mm² THHN Cu.
CONV. OUTLETS C9 C10 CONV. OUTLETS 12 WASHING MACHINE 1 500 2.27 20 AT,2P 220V1Ø 2No. 3.5mm² THHN Cu. 15mmØ pvc conduit
13 REF. LOAD 1 20 AT,2P 220V1Ø 2No. 3.5mm² THHN Cu. 15mmØ pvc conduit
2No. 5.5mm² THHN Cu. 3No. 5.5mm² THHN Cu. 250 1.14
PUMP MOTOR C11 C12 WASHING MACHINE 14 RANGE LOAD 1 2800 13.00 30 AT,2P 220V1Ø 2No. 5.5mm² THHN Cu. 15mmØ pvc conduit
15 ACU LOAD 1 1760 8.0 30 AT,2P 220V1Ø 2No. 5.5mm² THHN Cu. 15mmØ pvc conduit
3No. 5.5mm² THHN Cu. 2No. 5.5mm² THHN Cu.
REF LOAD C13 C14 RANGE LOAD 16 ACU LOAD 1 1760 8.0 30 AT,2P 220V1Ø 2No. 5.5mm² THHN Cu. 15mmØ pvc conduit
17 ACU LOAD 1 1760 8.0 30 AT,2P 220V1Ø 2No. 5.5mm² THHN Cu. 15mmØ pvc conduit
3No. 5.5mm² THHN Cu. 2No. 5.5mm² THHN Cu.
ACU LOAD C15 C16 ACU LOAD 18 ACU LOAD 1 1760 8.0 30 AT,2P 220V1Ø 2No. 5.5mm² THHN Cu. 15mmØ pvc conduit
19 WATER HEATER 1 5500 25. 30 AT,2P 220V1Ø 2No. 5.5mm² THHN Cu. 15mmØ pvc conduit
2No. 5.5mm² THHN Cu. 2No. 5.5mm² THHN Cu.
ACU LOAD C17 C18 ACU LOAD 20 SPARE
21 SPARE
2No. 5.5mm² THHN Cu. 3No. 5.5mm² THHN Cu.
WATER HEATER C19 C20 SPARE 22 SPARE
3No. 5.5mm² THHN Cu. 3No. 5.5mm² THHN Cu. 2No. 1-14MM²THHN
SPARE C21 C22 SPARE TOTAL MAINS 69 20 9 21,716 99. 19 A 100 AT,2P
Cu WIRE GRNDNG.
40mmØ pvc conduit
8.0 mm. sq
IT = 99.19 + 2.0A =101.19 A USE: 8.0 MM. sq. THHN Cu GROUNDING ; 40MMØ PVC CONDUIT
CERTIFIED BY : PROJECT TITLE : OWNER : REPUBLIC ACT 9266: SHEET CONTENTS: SHEET NO.:
ENGR. IAN JAN R. HERNANDO Article 4 section 33 , stipulates that all drawings and specifications and other
SINGLE LINE DIAGRAM, ELECTRICAL
E-2
PROFESSIONAL ELECTRICAL ENGINEER (P.E.E.) contract documents duly signed, stamped or sealed, as instruments of service,
MR. ERNIE ENOJAS & are the intellectual property and documents of the architect, whether the object
SYMBOLS, SPECIFICATIONS, DESIGN
REG. NO.: 2588-19 PLACE: ILOILO CITY TIN #:
PROPOSED TWO STOREY OFFICE BUILDING MRS. EVE ENOJAS for which they are made is executed or not. It shall be unlawful for any person
ANALYSIS, & SCHEDULE OF LOADS
to duplicate to make copies of said documents for use in the repetition of and
CLASSY & COMFORTABLE PTR NO.: APPROVED
for other projects or buildings, whether executed partly or in whole, without the
written consent of architect or author of said documents.
U N I QU E H OME S 5784187 DATE: 01/03/18 126-174-513 LOCATION : SAN DONISIO, ILOILO