Stairs and Platform PDF
Stairs and Platform PDF
Stairs and Platform PDF
RECOMMENDING APPROVAL:
APPROVED BY:
A. GENERAL
1. CONSTRUCTION NOTES AND TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS
OTHERWISE SHOWN OR NOTED, MODIFY TYPICAL DETAILS AS DIRECTED TO MEET SPECIAL HEAD STRUCTURAL SEC. DATE
CONDITIONS.
2. SHOP DRAWINGS WITH ERECTION & PLACING DIAGRAMS OF ALL STRUCTURAL STEEL, BLDG. OFFICIAL DATE
MISCELLANEOUS IRON, PRE-CAST CONCRETE ETC. SHALL BE SUBMITTED FOR ENGINEER'S
APPROVAL BEFORE FABRICATION.
12.20
14.20
7.00
PH AND COAGULATION TANK CLARIFIER TANK MEMBRANE TANK
3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE ALL WORK IS TO BEGIN, CHECK
WITH MECHANICAL OR ELECTRICAL CONTRACTORS FOR CONDUITS, PIPE SLEEVES, ETC, TO
BE EMBEDDED IN CONCRETE.
SHORING & BRACINGS OF THE STRUCTURE FOR ALL LOADS THAT MAYBE IMPOSED DURING
CONSTRACTION.
2.00
1. ALL MATERIALS & WORKMANSHIP SHALL CONFIRM WITH THE LATEST BUILDING CODE OF UP
1.00
UP UP
FOUNDATION AND 3
3000 PSI IN. (19MM) 4 IN. (100MM)
RETAINING WALL 4
22.30 2.30 1.80
3. ALL REINFORCING BARS SHALL CONFORM TO ASTM A615 GRADE 40 FOR DIA.20MM &
4.80
PH AND COAGULATION TANK CLARIFIER TANK MEMBRANE TANK
SMALLER BARS & GRADE 60 FOR DAI. 25MM & LARGER BARS. COLUMN HOOPS ARE ALL
GRADE 40 BARS.
2.20
4. IN GENERAL, THE LATEST EDITION OF ACI - 315, MANUAL OF STANDARD PRACTICE
DETAILING REINFORCED CONCRETE STRUCTURES SHALL BE ADHERED TO UNLESS
OTHERWISE SHOWN OR NOTED.
5. MAINTAIN MINIMUM CONCRTE COVER FOR REINFORCING STEEL AS FOLLOWS:
SUSPENDED SLABS......................................................3/4 IN. (19MM.)
SLAB ON GRADE.........................................................1 1/2 IN. (38MM.)
WALLS ABOVE GRADE.....................................................1 IN. (25MM.)
BEAM STIRRUPS AND COLUMN TIES.......................1 1/2 IN. (38MM.)
FRONT ELEVATION
S C A L E 1 : 1 7 5 M T S
L
WHERE CONCRETE IS EXPOSED
L/4 L/4
TO EARTH BUT POURED AGAINST FORMS...................2 IN. (50MM.)
WHERE CONCRETE IS DEPOSITED 0.25 0.20
10mm.Ø @ 0.20m. O.C.
6. SPLICES SHALL BE SECURELY WIRED TOGETHER & SHALL LAP OR EXTEND IN 1OmmØ @ 0.20m. O.C. TEMP. BARS
1OmmØ @ 0.20m. O.C.
ACCORDANCE WITH TABLE 1 (TABLE OF LAP SLICE & ANCHORAGE LENGTH) UNLESS 1Omm EACH CORNER
OTHERWISE SHOWN ON DRAWINGS, SPLICES SHALL BE STAGGERED WHENEVER POSSIBLE.
0.20
3.THE CONTRACTOR SHALL NOTIFY THE ENGINEER AFTER FOOTING EXCAVATION HAVE
BEEN COMPLETED & PRIOR TO CONCRETING TO CONFIRM THE DESIGN SOIL BEARING
CAPACITY.
1.00
CONCRETE WALL OF TANK EVERY 1.00 METERS
0.180m. THICK
0.30
STAIRS AND PLATFORM 5-Ø16mm.
1.00
STAIR DETAILS
S C A L E 1 : 3 0 M T S
SEAL PROJECT TITLE: APPROVED AS TO PLAN AND SPECS: SHEET CONTENT: SHEET NUMBER:
CONSTRUCTION NOTES
FRONT ELEVATION S
PTR NO : DATE :
OWNER STAIR DETAILS
01 01
PLACE : LOCATION: CARIGARA, LEYTE LOCATION: CARIGARA, LEYTE