Rs 232
Rs 232
Rs 232
Automation Portal
RS232
Project
Name: RS232 Creation time: 06/04/2023 03:41:10 Last change 06/26/2023 04:21:32 Author: Mai Anh
Last modified Mai Anh Version:
by:
Comment:
Operating system
Name Description
Operating system Microsoft Windows 10 Pro
Version of the operating system 6.3.9600.0
Operating system service pack
Version of the Internet Explorer 11.345.17134.0
Computer name DESKTOP-1VPGUG1
User name DESKTOP-1VPGUG1\Mai Anh
Installation path of the TIA Portal C:\Program Files\Siemens\Automation\Portal V17
Components
Name Version Release
TIA Portal Project Server V17 - TIA Portal Project Server Single SetupPackage V17.0 V17.00.00.00_43.02.00.01
V17.0 (MUSERVERV17)
Siemens Totally Integrated Automation Portal V17 - SIMATIC S7-PLCSIM V17.0 V17.00.00.00_43.00.39.01
V17.0 (S7_PLCSIM_V17)
TIA Administrator - AWB Licensing Module V1.0 + SP4 (TIAADMIN) V1.0 + SP4 V01.00.04.00_01.18.00.04
TIA Administrator - AWB Software Management V1.0 + SP4 (TIAADMIN) V1.0 + SP4 V01.00.04.00_01.18.00.04
TIA Administrator - TIA UMC Agent Configurator Module V1.0 + SP4 (TIAAD‐ V1.0 + SP4 V01.00.04.00_01.18.00.04
MIN)
TIA Administrator - TIA Administrator V1.0 SP4 (TIAADMIN) V1.0 + SP4 V01.00.04.00_01.18.00.04
Siemens Totally Integrated Automation Portal V17 - HM All Editions Single V17.0 V17.00.00.00_43.02.00.01
SetupPackage V17.0 (TIAP17)
Siemens Totally Integrated Automation Portal V17 - HM NoBasic Single V17.0 V17.00.00.00_43.02.00.01
SetupPackage V17.0 (TIAP17)
Siemens Totally Integrated Automation Portal V17 - Hardware Support Base V17.0 V17.00.00.00_41.01.00.01
Package 0 V17.0 (TIAP17)
Siemens Totally Integrated Automation Portal V17 - Multiuser Client Single V17.0 V17.00.00.00_43.02.00.01
SetupPackage V17.0 (TIAP17)
Siemens Totally Integrated Automation Portal V17 - Version Control Inter‐ V17.0 V17.00.00.00_43.02.00.01
face SetupPackage V17.0 (TIAP17)
Siemens Totally Integrated Automation Portal V17 - STEP 7 Safety Single V17.0 V17.00.00.00_43.02.00.01
SetupPackage V17.0 (TIAP17)
Siemens Totally Integrated Automation Portal V17 - STEP 7 Single Setup‐ V17.0 V17.00.00.00_43.02.00.01
Package V17.0 (TIAP17)
Siemens Totally Integrated Automation Portal V17 - Hardware Support Base V17.0 V17.00.00.00_41.01.00.01
Package 02 V17.0 (TIAP17)
Siemens Totally Integrated Automation Portal V17 - Hardware Support Base V17.0 V17.00.00.00_41.01.00.01
Package 03 V17.0 (TIAP17)
Siemens Totally Integrated Automation Portal V17 - Hardware Support Base V17.0 V17.00.00.00_41.01.00.01
Package 04 V17.0 (TIAP17)
Siemens Totally Integrated Automation Portal V17 - Support Base Package V17.0 V17.00.00.00_41.01.00.01
TO-01 V17.0 (TIAP17)
Siemens Totally Integrated Automation Portal V17 - Support Base Package V17.0 V17.00.00.00_41.01.00.01
TO-02 V17.0 (TIAP17)
Siemens Totally Integrated Automation Portal V17 - Hardware Support Base V17.0 V17.00.00.00_41.01.00.01
Package WCF-01 V17.0 (TIAP17)
Siemens Totally Integrated Automation Portal V17 - TIACOMPCHECK Single V17.0 V17.00.00.00_43.02.00.01
SetupPackage V17.0 (TIAP17)
Siemens Totally Integrated Automation Portal V17 - Simatic Single Setup‐ V17.0 V17.00.00.00_43.02.00.01
Package V17.0 (TIAP17)
Siemens Totally Integrated Automation Portal V17 - WinCC Single Setup‐ V17.0 V17.00.00.00_43.02.00.01
Package V17.0 (TIAP17)
Siemens Totally Integrated Automation Portal V17 - Openness SetupPack‐ V17.0 V17.00.00.00_43.02.00.01
age V17.0 (TIAP17)
Siemens Totally Integrated Automation Portal V17 - WinCC Transfer Manda‐ V17.0 V17.00.00.00_43.02.00.01
tory Single SetupPackage V17.0 (TIAP17)
User Management Component - UserManagementComponentx64 V2.9 V2.9 + SP3 V02.09.03.00_12.03.00.03
SP3 (UMC64)
User Management Component - umtrayiconx64 V2.9 + SP3 (UMC64) V2.9 + SP3 V02.09.03.00_12.03.00.03
WinCC Runtime Advanced V17.0 - HMIRTM Tagging Package 01 Single V17.0 V17.00.00.00_43.02.00.01
SetupPackage V17.0 (HMIRTM_V11)
WinCC Runtime Professional V17 - SIMATIC WinCC Runtime V17.0 (SCADA- V17.0 V07.05.77.00_01.46.00.02
RT_V11)
WinCC Runtime Professional V17 - OPCUA_Client V1.1 + SP2 (SCADA- V1.1 + SP2 V01.01.02.00_01.10.00.01
RT_V11)
WinCC Runtime Professional V17 - SCADA Simulation Single SetupPackage V17.0 V17.00.00.00_43.02.00.01
V17.0 (SCADA-RT_V11)
Siemens Totally Integrated Automation Portal V17 - Simatic Single Setup‐ V17.0 V17.00.00.00_43.02.00.01
Package 32 Bit V17.0 (TIAP17)
Siemens Totally Integrated Automation Portal V17 - WinCC Single Setup‐ V17.0 V17.00.00.00_43.02.00.01
Package 32 Bit V17.0 (TIAP17)
SIMATIC HMI License Manager Panel Plugin (x64) 17.0.0.0 V17.00.00.00_43.02.00.01
SIMATIC WinCC Runtime Advanced Driver (x64) 17.0.0.0 V17.00.00.00_43.02.00.01
ETWEventCollector 17.0.0.0 V17.00.00.00_43.02.00.01
SIMATIC NCM FWL 64 5.6.0.3 K5.6.0.3_1.1.0.2
NCM GPRS 64 01.02.00.00 V1.2.0.0_2.1.0.1
SIMATIC PLCSIM 64 17.00.00 17.00.00.00_01.00.37.01
SIMATIC Device Drivers 9.3 09.03.00.00_01.05.00.06
TelemetryConnector 1.3.0.5 V01.03.00.05_01.00.00.01
Totally Integrated
Automation Portal
Products
Name Version Release
TIA Portal Project Server V17.0 V17.00.00.00_43.02.00.01
SIMATIC S7-PLCSIM V17.0 V17.00.00.00_43.00.39.01
TIA Administrator V1.0 01.00.04.00_01.18.00.04
SIMATIC STEP 7 Prof - STEP 7 Safety - WinCC Prof V17.0 V17.00.00.00_43.02.00.01
User Management Component V2.9 V02.09.00.00_00.00.00.00
UMC Status Application V1.0 V01.00.00.00_01.01.00.01
SIMATIC WinCC Runtime Advanced Simulation V17.0 V17.00.00.00_43.02.00.01
SIMATIC WinCC Runtime Professional Simulation V17.0 V17.00.00.00_43.02.00.01
Automation License Manager V6.0 + SP9 + Upd2 06.00.09.02_01.01.00.02
S7-PLCSIM V5.4 + SP8 V05.04.08.01_01.24.00.01
SIMATIC ProSave V17.0 V17.00.00.00_43.02.00.01
Totally Integrated
Automation Portal
RS232
PLC_1 [CPU 1214C AC/DC/Rly]
PLC_1
General\Project information
Name PLC_1 Author Mai Anh Comment
Slot 1 Rack 0
General\Catalog information
Short designation CPU 1214C AC/DC/Rly Description Work memory 100 KB; 120/240VAC Article number 6ES7 214-1BG40-0XB0
power supply with DI14 x 24VDC
SINK/SOURCE, DQ10 x relay and AI2
on board; 6 high-speed counters
and 4 pulse outputs on-board; signal
board expands on-board I/O; up to
3 communication modules for serial
communication; up to 8 signal mod‐
ules for I/O expansion; PROFINET IO
controller, I-device, transport protocol
TCP/IP, secure Open User Communica‐
tion, S7 communication, Web server,
OPC UA: Server DA
Firmware version V4.5 False
General\Identification & Maintenance
Plant designation Location identifier Installation date 2023-06-04 08:45:37.714
Additional informa‐
tion
General\Checksums
Text lists FA 70 E8 75 1D 5A 8E 29 Software 34 BF E5 58 C2 8A 7D A5
PROFINET interface [X1]\General
Name PROFINET interface_1 Author Mai Anh Comment
PROFINET interface [X1]\General\Project information
Name DI 14/DQ 10_1 Comment Name AI 2_1
Comment
PROFINET interface [X1]\Ethernet addresses\Interface networked with
Subnet: PN/IE_1
PROFINET interface [X1]\Ethernet addresses\Internet protocol version 4 (IPv4)
IP configuration Set IP address in the project IP address: 192.168.0.1 Subnet mask: 255.255.255.0
Use router False
PROFINET interface [X1]\Ethernet addresses\PROFINET
PROFINET device False Generate PROFINET True PROFINET device plc_1
name is set directly at device name auto‐ name:
the device matically
Converted name: plcxb1d0ed Device number: 0
PROFINET interface [X1]\Time synchronization
Enable time synchro‐ Enable time synchronization via NTP IP addresses Server 1 0.0.0.0
nization via NTP serv‐ server
er
Server 2 0.0.0.0 Server 3 0.0.0.0 Server 4 0.0.0.0
Update interval 10sec CPU synchronizes the No synchronization
modules of the de‐
vice.
PROFINET interface [X1]\Digital inputs\Channel0
Channel address I0.0 Input filters 6.4 millisec Enable pulse catch 0
PROFINET interface [X1]\Digital inputs\Channel0\
Enable rising edge 0 Prefix Event Rising 49152 Event name: 0
detection Edge
Hardware interrupt: 0 Rising edge0 Rising edge0
PROFINET interface [X1]\Digital inputs\Channel0\
Enable falling edge 0 Prefix Event Falling 49280 Event name: 0
detection Edge
Hardware interrupt: 0 Falling edge0 Falling edge0
PROFINET interface [X1]\Digital inputs\Channel1
Channel address I0.1 Input filters 6.4 millisec Enable pulse catch 0
PROFINET interface [X1]\Digital inputs\Channel1\
Enable rising edge 0 Prefix Event Rising 49153 Event name: 0
detection Edge
Hardware interrupt: 0 Rising edge1 Rising edge1
PROFINET interface [X1]\Digital inputs\Channel1\
Enable falling edge 0 Prefix Event Falling 49281 Event name: 0
detection Edge
Hardware interrupt: 0 Falling edge1 Falling edge1
PROFINET interface [X1]\Digital inputs\Channel2
Channel address I0.2 Input filters 6.4 millisec Enable pulse catch 0
PROFINET interface [X1]\Digital inputs\Channel2\
Enable rising edge 0 Prefix Event Rising 49154 Event name: 0
detection Edge
Hardware interrupt: 0 Rising edge2 Rising edge2
PROFINET interface [X1]\Digital inputs\Channel2\
Enable falling edge 0 Prefix Event Falling 49282 Event name: 0
detection Edge
Hardware interrupt: 0 Falling edge2 Falling edge2
PROFINET interface [X1]\Digital inputs\Channel3
Channel address I0.3 Input filters 6.4 millisec Enable pulse catch 0
PROFINET interface [X1]\Digital inputs\Channel3\
Enable rising edge 0 Prefix Event Rising 49155 Event name: 0
detection Edge
Hardware interrupt: 0 Rising edge3 Rising edge3
Totally Integrated
Automation Portal
Type Addr. from Addr. to Module PIP Device name Device number Size Master / IO sys‐ Rack Slot
tem
I 0 1 DI 14/DQ 10_1 Automatic up‐ PLC_1 [CPU - 2 Bytes - 0 11
date 1214C AC/DC/
Rly]
O 0 1 DI 14/DQ 10_1 Automatic up‐ PLC_1 [CPU - 2 Bytes - 0 11
date 1214C AC/DC/
Rly]
I 64 67 AI 2_1 Automatic up‐ PLC_1 [CPU - 4 Bytes - 0 12
date 1214C AC/DC/
Rly]
I 1000 1003 HSC_1 Automatic up‐ PLC_1 [CPU - 4 Bytes - 0 1 16
date 1214C AC/DC/
Rly]
I 1004 1007 HSC_2 Automatic up‐ PLC_1 [CPU - 4 Bytes - 0 1 17
date 1214C AC/DC/
Rly]
I 1008 1011 HSC_3 Automatic up‐ PLC_1 [CPU - 4 Bytes - 0 1 18
date 1214C AC/DC/
Rly]
I 1012 1015 HSC_4 Automatic up‐ PLC_1 [CPU - 4 Bytes - 0 1 19
date 1214C AC/DC/
Rly]
I 1016 1019 HSC_5 Automatic up‐ PLC_1 [CPU - 4 Bytes - 0 1 20
date 1214C AC/DC/
Rly]
I 1020 1023 HSC_6 Automatic up‐ PLC_1 [CPU - 4 Bytes - 0 1 21
date 1214C AC/DC/
Rly]
O 1000 1001 Pulse_1 Automatic up‐ PLC_1 [CPU - 2 Bytes - 0 1 32
date 1214C AC/DC/
Rly]
O 1002 1003 Pulse_2 Automatic up‐ PLC_1 [CPU - 2 Bytes - 0 1 33
date 1214C AC/DC/
Rly]
O 1004 1005 Pulse_3 Automatic up‐ PLC_1 [CPU - 2 Bytes - 0 1 34
date 1214C AC/DC/
Rly]
O 1006 1007 Pulse_4 Automatic up‐ PLC_1 [CPU - 2 Bytes - 0 1 35
date 1214C AC/DC/
Rly]
Totally Integrated
Automation Portal
Network 1:
%DB3
"PORT_CFG_DB"
PORT_CFG
EN ENO
%M1.0 DONE False
"FirstScan" ERROR False
REQ STATUS 16#0
269
"Local~CM_1241_
(RS232)_1" PORT
0 PROTOCOL
6 BAUD
1 PARITY
1 DATABITS
1 STOPBITS
1 FLOWCTRL
'' XONCHAR
'' XOFFCHAR
2000 WAITTIME
Network 2:
%DB10
"RCV_PTP_DB_1"
RCV_PTP
EN ENO
%M0.0 NDR False
"Clock_10Hz" EN_R ERROR False
STATUS 16#0
269
"Local~CM_1241_ LENGTH 0
(RS232)_1" PORT
"DATA_RECIVE".
data_recive_
indica BUFFER
Network 3:
LEN
String
EN ENO
"DATA_RECIVE". "DATA_RECIVE".
data_recive_ data_recive_
indica IN OUT indica_len
Network 4:
%DB5
"IEC_Timer_0_DB_
"DATA_RECIVE". 1"
data_recive_ TP %M2.3
indica_len Time "Tag_8"
<>
Int IN Q
19 T#1100MS PT ET T#0ms
%M2.2
"Tag_7"
R
Totally Integrated
Automation Portal
Network 5:
"DATA_RECIVE".
data_recive_
indica_len %I0.0 %M2.2
"OK_signal" "Tag_7"
==
S
Int
19
Network 6:
%DB2
"IEC_Timer_0_DB"
%M2.2 TON %M2.3 %M2.5
"Tag_7" Time "Tag_8" "Tag_10"
IN Q
t#1000MS PT ET T#0ms
%M2.2
"Tag_7"
R
Network 7:
Network 8:
MOVE_BLK
EN ENO
"DATA_SEND". "DATA_SEND".
send_printer_ data_send_
weight[0] IN OUT printer[3]
4 COUNT
Network 9:
MOVE_BLK
EN ENO
"DATA_SEND". "DATA_SEND".
send_printer_ data_send_
start[0] IN OUT printer[0]
3 COUNT
Network 10:
MOVE_BLK
EN ENO
"DATA_SEND". "DATA_SEND".
send_printer_ data_send_
end[0] IN OUT printer[7]
1 COUNT
Network 11:
Totally Integrated
Automation Portal
%DB1
"SEND_PTP_DB"
SEND_PTP
EN ENO
%M2.5 DONE False
"Tag_10" ERROR False
REQ STATUS 16#0
269
"Local~CM_1241_
(RS232)_1" PORT
"DATA_SEND".
data_send_
printer BUFFER
False PTRCL
Network 12:
Totally Integrated
Automation Portal
Name Data type Start value Retain Accessible Writ‐ Visible in Setpoint Supervi‐ Comment
from able HMI engi‐ sion
HMI/OPC from neering
UA/Web HMI/
API OPC
UA/
Web
API
Static
send_printer_end Array[0..0] of True True True True False
Byte
send_printer_end[0] Byte 16#03 True True True True False
send_printer_start Array[0..2] of True True True True False
Byte
send_printer_start[0] Byte 16#02 True True True True False
send_printer_start[1] Byte 16#10 True True True True False
send_printer_start[2] Byte 16#34 True True True True False
send_printer_weight Array[0..3] of False True True True False
Byte
send_printer_weight[0] Byte 16#0 False True True True False
send_printer_weight[1] Byte 16#0 False True True True False
send_printer_weight[2] Byte 16#0 False True True True False
send_printer_weight[3] Byte 16#0 False True True True False
data_send_indica String '' False True True True False
data_send_printer Array[0..7] of False True True True False
Byte
data_send_printer[0] Byte 16#0 False True True True False
data_send_printer[1] Byte 16#0 False True True True False
data_send_printer[2] Byte 16#0 False True True True False
data_send_printer[3] Byte 16#0 False True True True False
data_send_printer[4] Byte 16#0 False True True True False
data_send_printer[5] Byte 16#0 False True True True False
data_send_printer[6] Byte 16#0 False True True True False
data_send_printer[7] Byte 16#0 False True True True False
countChar UInt 0 False True True True False
RE_VAL Word 16#0 False True True True False
data_send_dv Array[0..1] of True True True True False
Byte
data_send_dv[0] Byte 16#4B True True True True False
data_send_dv[1] Byte 16#47 True True True True False
Totally Integrated
Automation Portal
Name Data type Start value Retain Accessible Writ‐ Visible in Setpoint Supervi‐ Comment
from able HMI engi‐ sion
HMI/OPC from neering
UA/Web HMI/
API OPC
UA/
Web
API
Static
ret_val Word 16#0 False True True True False
weight_hex DWord 16#0 False True True True False
data_recive_indica String '' False True True True False
data_weight_len Int 0 False True True True False
data_weight String '44.55kg' False True True True False
data_recive_indica_len Int 0 False True True True False
data_weight_int Real 0.0 False True True True False
Totally Integrated
Automation Portal
RS232 / PLC_1 [CPU 1214C AC/DC/Rly] / Program blocks / System blocks / Program resources
PORT_CFG_DB [DB3]
PORT_CFG_DB Properties
General
Name PORT_CFG_DB Number 3 Type DB Language DB
Numbering Automatic
Information
Title Author SIMATIC Comment Family PtP_Comm
Version 1.0 User-defined ID PORT_CFG
Name Data type Start value Retain Accessible Writ‐ Visible in Setpoint Supervi‐ Comment
from able HMI engi‐ sion
HMI/OPC from neering
UA/Web HMI/
API OPC
UA/
Web
API
Input
REQ Bool False False True True True False
PORT PORT 0 False True True True False
PROTOCOL UInt 0 False True True True False
BAUD UInt 0 False True True True False
PARITY UInt 0 False True True True False
DATABITS UInt 0 False True True True False
STOPBITS UInt 0 False True True True False
FLOWCTRL UInt 0 False True True True False
XONCHAR Char '' False True True True False
XOFFCHAR Char '' False True True True False
WAITTIME UInt 2000 False True True True False
Output
DONE Bool False False True True True False
ERROR Bool False False True True True False
STATUS Word 16#0 False True True True False
InOut
Static
Totally Integrated
Automation Portal
RS232 / PLC_1 [CPU 1214C AC/DC/Rly] / Program blocks / System blocks / Program resources
RCV_PTP_DB_1 [DB10]
RCV_PTP_DB_1 Properties
General
Name RCV_PTP_DB_1 Number 10 Type DB Language DB
Numbering Automatic
Information
Title Author SIMATIC Comment Family PtP_Comm
Version 1.0 User-defined ID RCV_PTP
Name Data type Start value Retain Accessible Writ‐ Visible in Setpoint Supervi‐ Comment
from able HMI engi‐ sion
HMI/OPC from neering
UA/Web HMI/
API OPC
UA/
Web
API
Input
EN_R Bool False False True True True False
PORT PORT 0 False True True True False
BUFFER Variant False False False False False
Output
NDR Bool False False True True True False
ERROR Bool False False True True True False
STATUS Word 16#0 False True True True False
LENGTH UInt 0 False True True True False
InOut
Static
Totally Integrated
Automation Portal
RS232 / PLC_1 [CPU 1214C AC/DC/Rly] / Program blocks / System blocks / Program resources
SEND_PTP_DB [DB1]
SEND_PTP_DB Properties
General
Name SEND_PTP_DB Number 1 Type DB Language DB
Numbering Automatic
Information
Title Author SIMATIC Comment Family PtP_Comm
Version 1.0 User-defined ID SEND_PTP
Name Data type Start value Retain Accessible Writ‐ Visible in Setpoint Supervi‐ Comment
from able HMI engi‐ sion
HMI/OPC from neering
UA/Web HMI/
API OPC
UA/
Web
API
Input
REQ Bool False False True True True False
PORT PORT 0 False True True True False
BUFFER Variant False False False False False
LENGTH UInt 0 False True True True False
PTRCL Bool False False True True True False
Output
DONE Bool False False True True True False
ERROR Bool False False True True True False
STATUS Word 16#0 False True True True False
InOut
Static
Totally Integrated
Automation Portal
RS232 / PLC_1 [CPU 1214C AC/DC/Rly] / Program blocks / System blocks / Program resources
IEC_Timer_0_DB_1 [DB5]
IEC_Timer_0_DB_1 Properties
General
Name IEC_Timer_0_DB_1 Number 5 Type DB Language DB
Numbering Automatic
Information
Title Author Simatic Comment Family IEC
Version 1.0 User-defined ID IEC_TMR
Name Data type Start value Retain Accessible Writ‐ Visible in Setpoint Supervi‐ Comment
from able HMI engi‐ sion
HMI/OPC from neering
UA/Web HMI/
API OPC
UA/
Web
API
Static
PT Time T#0ms False True True True False
ET Time T#0ms False True False True False
IN Bool false False True True True False
Q Bool false False True False True False
Totally Integrated
Automation Portal
RS232 / PLC_1 [CPU 1214C AC/DC/Rly] / Program blocks / System blocks / Program resources
IEC_Timer_0_DB [DB2]
IEC_Timer_0_DB Properties
General
Name IEC_Timer_0_DB Number 2 Type DB Language DB
Numbering Automatic
Information
Title Author Simatic Comment Family IEC
Version 1.0 User-defined ID IEC_TMR
Name Data type Start value Retain Accessible Writ‐ Visible in Setpoint Supervi‐ Comment
from able HMI engi‐ sion
HMI/OPC from neering
UA/Web HMI/
API OPC
UA/
Web
API
Static
PT Time T#0ms False True True True False
ET Time T#0ms False True False True False
IN Bool false False True True True False
Q Bool false False True False True False
Totally Integrated
Automation Portal
RS232 / PLC_1 [CPU 1214C AC/DC/Rly] / PLC tags / Default tag table [56]
PLC tags
PLC tags
Name Data type Address Retain Accessi‐ Writable Visible in Supervision Comment
ble from from HMI engi‐
HMI/OPC HMI/OPC neering
UA/Web UA/Web
API API
OK_signal Bool %I0.0 False True True True
DATA_ SEND Char %MB0 False True True True
System_Byte Byte %MB1 False True True True
FirstScan Bool %M1.0 False True True True
DiagStatusUpdate Bool %M1.1 False True True True
AlwaysTRUE Bool %M1.2 False True True True
AlwaysFALSE Bool %M1.3 False True True True
Tag_1 Bool %M0.1 False True True True
Clock_Byte Byte %MB0 False True True True
Clock_10Hz Bool %M0.0 False True True True
Clock_5Hz Bool %M0.1 False True True True
Clock_2.5Hz Bool %M0.2 False True True True
Clock_2Hz Bool %M0.3 False True True True
Clock_1.25Hz Bool %M0.4 False True True True
Clock_1Hz Bool %M0.5 False True True True
Clock_0.625Hz Bool %M0.6 False True True True
Clock_0.5Hz Bool %M0.7 False True True True
Tag_2 Real %MD2 False True True True
Tag_3 Bool %M2.0 False True True True
Tag_4 Bool %I0.4 False True True True
Tag_5 Bool %I0.1 False True True True
Tag_6 Bool %M2.1 False True True True
Tag_7 Bool %M2.2 False True True True
Tag_8 Bool %M2.3 False True True True
Tag_9 Bool %M3.3 False True True True
Tag_10 Bool %M2.5 False True True True
Totally Integrated
Automation Portal
RS232 / PLC_1 [CPU 1214C AC/DC/Rly] / PLC tags / Default tag table [56]
User constants
User constants
Name Data type Value Comment
Totally Integrated
Automation Portal
Type Addr. from Addr. to Module PIP Device name Device number Size Master / IO sys‐ Rack Slot
tem
I 0 1 DI 14/DQ 10_1 Automatic up‐ PLC_1 [CPU - 2 Bytes - 0 11
date 1214C AC/DC/
Rly]
O 0 1 DI 14/DQ 10_1 Automatic up‐ PLC_1 [CPU - 2 Bytes - 0 11
date 1214C AC/DC/
Rly]
I 64 67 AI 2_1 Automatic up‐ PLC_1 [CPU - 4 Bytes - 0 12
date 1214C AC/DC/
Rly]
I 1000 1003 HSC_1 Automatic up‐ PLC_1 [CPU - 4 Bytes - 0 1 16
date 1214C AC/DC/
Rly]
I 1004 1007 HSC_2 Automatic up‐ PLC_1 [CPU - 4 Bytes - 0 1 17
date 1214C AC/DC/
Rly]
I 1008 1011 HSC_3 Automatic up‐ PLC_1 [CPU - 4 Bytes - 0 1 18
date 1214C AC/DC/
Rly]
I 1012 1015 HSC_4 Automatic up‐ PLC_1 [CPU - 4 Bytes - 0 1 19
date 1214C AC/DC/
Rly]
I 1016 1019 HSC_5 Automatic up‐ PLC_1 [CPU - 4 Bytes - 0 1 20
date 1214C AC/DC/
Rly]
I 1020 1023 HSC_6 Automatic up‐ PLC_1 [CPU - 4 Bytes - 0 1 21
date 1214C AC/DC/
Rly]
O 1000 1001 Pulse_1 Automatic up‐ PLC_1 [CPU - 2 Bytes - 0 1 32
date 1214C AC/DC/
Rly]
O 1002 1003 Pulse_2 Automatic up‐ PLC_1 [CPU - 2 Bytes - 0 1 33
date 1214C AC/DC/
Rly]
O 1004 1005 Pulse_3 Automatic up‐ PLC_1 [CPU - 2 Bytes - 0 1 34
date 1214C AC/DC/
Rly]
O 1006 1007 Pulse_4 Automatic up‐ PLC_1 [CPU - 2 Bytes - 0 1 35
date 1214C AC/DC/
Rly]
Totally Integrated
Automation Portal
RS232
Ungrouped devices
This folder is empty.
Totally Integrated
Automation Portal
RS232
Security settings
This folder is empty.
Totally Integrated
Automation Portal
Editing language
English (United States)