Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Telematic Supplement

Download as pdf or txt
Download as pdf or txt
You are on page 1of 14

Service Manual Supplement

Telematics

Part No. 1262580


Rev A
December 2014
Service Manual Supplement December 2014

Introduction
Introduction Introduction

Compliance
Wireless Certifications
Telematic device(s) should comply with specific
wireless carrier certifications where applicable and
comply with the following:
N. America — PTCRB, FCC/IC
Europe — CE, R&TTE

Technical Publications
Genie has endeavored to deliver the highest
degree of accuracy possible. However, continuous
improvement of our products is a Genie policy.
Therefore, product specifications are subject to
change without notice.
Readers are encouraged to notify Genie of errors
and send in suggestions for improvement. All
communications will be carefully considered for
future printings of this and all other manuals.

Contact Us:
Internet: www.genielift.com
E-mail: awp.techpub@terex.com

Copyright © 2014 by Terex Corporation


1262580 Rev A, December 2014

First Edition, First Printing

Genie is a registered trademark of Terex South Dakota, Inc. in


the U.S.A. and many other countries.

“GS”, "GR", "QS", "S", "Z" and "GTH" are trademarks of Terex
South Dakota, Inc.

ii Telematics Part No. 1262580


December 2014

Table of Contents

Introduction Introduction........................................................................................................... ii
Wireless Certifications ............................................................................................ ii

Section 1 Telematics Pin Legend ........................................................................................ 4


S and Z Booms, IC and Bi-Energy Models ............................................................ 4
Z-30N, Z-34 DC and Z-45 DC Models ................................................................... 6
GR, GRC, QS and Slab Scissors Models .............................................................. 8
GS-2669, GS-3369 and GS-4069 DC and Bi-Energy Models ............................... 9
GS-69 RT, GS-84 RT and GS-90 RT Models ...................................................... 10
GTH-636, GTH-844 and GTH-1056 Models ........................................................ 12

Part No. 1262580 Telematics iii


Service Manual Supplement December 2014

Telematics Pin Legend


Section 1 Telematics Pin Legend
S and Z Booms, IC and Bi-Energy Models

This Legend Only Applies to the Following Genie Models


S-40 S-60 S-80 S-100 Z-34/22 (BE)
S-40 TRAX S-60 X S-80 X S-105 Z-34/22 (IC)
S-45 S-60 XC S-85 S-120 Z-45/25 (BE)
S-45 TRAX S-60 TRAX S-125 Z-45/25 (IC)
S-65 S-100 HD Z-45/25J (IC)
S-65 TRAX S-120 HD Z-51/30
SX-150 Z-62/40
SX-180 Z-80/60
ZX-135/70

Genie installed Telematics connector is wired with an Active High digital input.

8 7 6 5
1 2 3 4

Pin Circuit Type Circuit Properties Genie Machine Function(s) Telematics Use Case
1 System Power 12 VDC Battery Positive — constant power Supply power to device
5 Amp Max. allowed
draw
2 System Ground 0 VDC Battery Negative Device Ground
3 Digital Output 1 12 VDC Engine Run Hour Meter Monitor Engine Hours
12V = engine run, 0V = engine off
4 Digital Output 2 12 VDC Key Switch Activation Monitor Machine Utilization
12V = Key SW On, 0V = Key SW
Off
5 Digital Output 3 12 VDC Foot Switch Monitor Machine Utilization
12V = active, 0V = inactive
6 Digital Input 1 12 VDC (standard) Remote Disable Engine Start Remotely Prevent Engine
or ground (optional) Start
7* Databus H CAN HIGH Genie Databus J1939 Engine Messages,
Receive Proprietary Genie
Telematics Message
8* Databus L CAN LOW Genie Databus J1939 Engine Messages,
Receive Proprietary Genie
Telematics Message
* Tier IV engine models only, J1939 engine message available
* Genie proprietary databus support

4 Telematics Part No. 1262580


December 2014 Service Manual Supplement

Telematics Pin Legend

Remote Disable Engine Start Relay Configuration

Telematics Active High - Schematic Telematics Active Low - Schematic


(standard wiring) (optional wiring)

1 1 1 1
30 87A 30 87A

2 2 12V
12V 3 86 85 4 86 85
SPST
SPST

1 Ignition Start Input


2 Relay
3 Telematics with Active High input
4 Telematics with Active Low input

Part No. 1262580 Telematics 5


Service Manual Supplement December 2014

Telematics Pin Legend


Z-30N, Z-34 DC and Z-45 DC Models

This Legend Only Applies to the Following Genie Models


Z-30/20N Z-45/25 DC
Z-30/20N RJ Z-45/25J DC
Z-34/22 DC
Genie installed Telematics connector is wired with an Active High digital input.

8 7 6 5
1 2 3 4

Pin Circuit Type Circuit Properties Genie Machine Function(s) Telematics Use Case
1 System Power 24 VDC Battery Positive — constant power Supply power to device
5 Amp Max. allowed
draw
2 System Ground 0 VDC Battery Negative Device Ground
3 Digital Output 1 24 VDC Hour Meter Monitor Machine Run Hours
24V = active, 0V = inactive
4 Digital Output 2 24 VDC Key Switch Activation Monitor Machine Utilization
24V = Key SW On, 0V = Key SW
Off
5 Digital Output 3 24 VDC Foot Switch Monitor Machine Utilization
24V = active, 0V = inactive

6 Digital Input 1 24 VDC (standard) Remote Machine Disable Remote Motor Controller
or Ground (optional) Shutdown
7 No Connection No Connection
8 No Connection No Connection

6 Telematics Part No. 1262580


December 2014 Service Manual Supplement

Telematics Pin Legend

Remote Disable relay Configuration

Telematics Active High - Schematic Telematics Active Low - Schematic


(standard wiring) (optional wiring)

1 1 1 1
30 87A 30 87A

2 2 24V
24V 3 86 85 4 86 85
SPST
SPST

1 Ignition Start Input


2 Relay
3 Telematics with Active High input
4 Telematics with Active Low input

Part No. 1262580 Telematics 7


Service Manual Supplement December 2014

Telematics Pin Legend


GR, GRC, QS and Slab Scissors Models

This Legend Only Applies to the Following Genie Models


GS-1530 GS-1532 GS-2046 GR-12 QS-12
GS-1930 GS-1932 GS-2646 GR-15 QS-15
GS-2032 GS-2646 AV GR-20 QS-20
GS-2632 GS-3246 GRC-12
GS-3232 GS-4047

Genie installed Telematics connector is wired with an Active High digital input.

8 7 6 5
1 2 3 4

Pin Circuit Type Circuit Properties Genie Machine Function(s) Telematics Use Case
1 System Power 24 VDC Battery Positive — constant power Supply power to device
5 Amp Max. allowed
draw
2 System Ground 0 VDC Battery Negative Device Ground
3 Digital Output 1 24 VDC Motor Controller Enable Monitor Machine Run Hours
24V = enabled, 0V = disabled
4 No Connection No Connection
5 No Connection No Connection
6 No Connection No Connection
7* Databus H CAN HIGH Genie Databus Receive Proprietary Genie
Telematics Message
8* Databus L CAN LOW Genie Databus Receive Proprietary Genie
Telematics Message
* Genie proprietary databus support

8 Telematics Part No. 1262580


December 2014 Service Manual Supplement

Telematics Pin Legend


GS-2669, GS-3369 and GS-4069 DC and Bi-Energy Models

This Legend Only Applies to the Following Genie Models


GS-2669 DC GS-2669 BE
GS-3369 DC GS-3369 BE
GS-4069 DC GS-4069 BE
Genie installed Telematics connector is wired with an Active High digital input.

8 7 6 5
1 2 3 4

Pin Circuit Type Circuit Properties Genie Machine Function(s) Telematics Use Case
1 System Power 24 VDC Battery Positive — constant power Supply power to device
5 Amp Max. allowed
draw
2 System Ground 0 VDC Battery Negative Device Ground
3 No Connection No Connection
4 No Connection No Connection
5 No Connection No Connection
6 No Connection No Connection
7* Databus H CAN HIGH Genie Databus Receive Proprietary Genie
Telematics Message
8* Databus L CAN LOW Genie Databus Receive Proprietary Genie
Telematics Message
* Genie proprietary databus support

Part No. 1262580 Telematics 9


Service Manual Supplement December 2014

Telematics Pin Legend


GS-69 RT, GS-84 RT and GS-90 RT Models

This Legend Only Applies to the Following Genie Models


GS-2669 RT GS-3384 RT GS-3390 RT
GS-3369 RT GS-4390 RT
GS-4069 RT GS-5390 RT

Genie installed Telematics connector is wired with an Active High digital input.

8 7 6 5
1 2 3 4

Pin Circuit Type Circuit Properties Genie Machine Function(s) Telematics Use Case
1 System Power 12 VDC Battery Positive — constant power Supply power to device
5 Amp Max. allowed
draw
2 System Ground 0 VDC Battery Negative Device Ground
3 Digital Output 1 12 VDC Engine Run Hour Meter Monitor Engine Hours
12V = engine run, 0V = engine off
4 Digital Output 2 12 VDC Key Switch
12V = Key SW On, 0V = Key SW
Off
5 No Connection No Connection Monitor machine utilization
6 Digital Input 1 12 VDC (standard) Remote Disable Engine Start Remote Engine Shutdown
or ground (optional)
7* Databus H CAN HIGH Genie Databus Receive Proprietary Genie
Telematics Message
8* Databus L CAN LOW Genie Databus Receive Proprietary Genie
Telematics Message
* Tier IV engine models only, J1939 engine message available
* Genie proprietary databus support

10 Telematics Part No. 1262580


December 2014 Service Manual Supplement

Telematics Pin Legend

Remote Disable Engine Start Relay Configuration

Telematics Active High - Schematic Telematics Active Low - Schematic


(standard wiring) (optional wiring)

1 1 1 1
30 87A 30 87A

2 2 12V
12V 3 86 85 4 86 85
SPST
SPST

1 Ignition Start Input


2 Relay
3 Telematics with Active High input
4 Telematics with Active Low input

Part No. 1262580 Telematics 11


Service Manual Supplement December 2014

Telematics Pin Legend


GTH-636, GTH-844 and GTH-1056 Models

This Legend Only Applies to the Following Genie Models


GTH-636
GTH-844
GTH-1056
Genie installed Telematics connector is wired with an Active High digital input.

8 7 6 5
1 2 3 4

Pin Circuit Type Circuit Properties Genie Machine Function(s) Telematics Use Case
1 System Power 12 VDC Battery Positive — constant power Supply power to device
5 Amp Max. allowed
draw
2 System Ground 0 VDC Battery Negative Device Ground
3 Digital Output 1 12 VDC Engine Run Hour Meter Monitor Engine Hours
12V = engine run, 0V = engine off
4* Digital Output 2 12 VDC Boom Angle Status Monitor Machine Utilization
12V = boom >55°, 0V <55°
5 Digital Output 3 12 VDC Parking Brake Monitor Machine Utilization
12V = active, 0V = inactive
6 Digital Input 1 12 VDC (standard) Remote Disable Engine Start Remotely Prevent Engine
or Ground (optional) Start
7 CAN HIGH J1939 Databus HIGH J1939 Receive J1939 Engine Data
8 CAN LOW J1939 Databus LOW J1939 Receive J1939 Engine Data
* Not available on GTH-636

12 Telematics Part No. 1262580


December 2014 Service Manual Supplement

Telematics Pin Legend

Remote Disable Engine Start Relay Configuration

Telematics Active High - Schematic Telematics Active Low - Schematic


(standard wiring) (optional wiring)

1 1 1 1
30 87A 30 87A

2 2 12V
12V 3 86 85 4 86 85
SPST
SPST

1 Ignition Start Input


2 Relay
3 Telematics with Active High input
4 Telematics with Active Low input
Telematics Part No. 1262580 Service Manual Supplement December 2014

Part No. 1262580 Telematics 13


Genie North America
Phone 425.881.1800
Toll Free USA and Canada
Distributed By:

800.536.1800
Fax 425.883.3475

Genie Australia Pty Ltd.


Phone +61 7 3456 4444
Fax +61 7 3375 1002
Genie Scandinavia
Phone 0046 3157 5154 Genie China
Fax 0046 3157 5104 Phone +86 21 53853768
Fax +86 21 53852569
Genie France
Phone 0033 237 260 986 Genie Sinapore
Fax 0033 237 260 998 Phone +65 67533544
Fax +65 67533544
Genie Iberica
Phone 0034 935 725 090 Genie Japan
Fax 0034 935 725 080 Phone +81 3 6436 2020
Fax +81 3 5445 1231
Genie Germany
Phone 0800 180 9017 Genie Korea
Phone 0049 4221 491 821 Phone +82 2 558 7267
Fax 0049 4221 491 820 Fax +82 2 558 3910

Genie U.K. Genie Brasil


Phone 0044 1476 584 333 Phone +55 11 4082 5600
Fax 0044 1476 584 330 Fax +55 22 4082 5630

Genie Mexico City Genie Holland


Phone +52 55 5666 5242 Phone +31 183 581 102
Fax +52 55 5666 3241 Fax +31 183 581 566

You might also like