Telematic Supplement
Telematic Supplement
Telematic Supplement
Telematics
Introduction
Introduction Introduction
Compliance
Wireless Certifications
Telematic device(s) should comply with specific
wireless carrier certifications where applicable and
comply with the following:
N. America — PTCRB, FCC/IC
Europe — CE, R&TTE
Technical Publications
Genie has endeavored to deliver the highest
degree of accuracy possible. However, continuous
improvement of our products is a Genie policy.
Therefore, product specifications are subject to
change without notice.
Readers are encouraged to notify Genie of errors
and send in suggestions for improvement. All
communications will be carefully considered for
future printings of this and all other manuals.
Contact Us:
Internet: www.genielift.com
E-mail: awp.techpub@terex.com
“GS”, "GR", "QS", "S", "Z" and "GTH" are trademarks of Terex
South Dakota, Inc.
Table of Contents
Introduction Introduction........................................................................................................... ii
Wireless Certifications ............................................................................................ ii
Genie installed Telematics connector is wired with an Active High digital input.
8 7 6 5
1 2 3 4
Pin Circuit Type Circuit Properties Genie Machine Function(s) Telematics Use Case
1 System Power 12 VDC Battery Positive — constant power Supply power to device
5 Amp Max. allowed
draw
2 System Ground 0 VDC Battery Negative Device Ground
3 Digital Output 1 12 VDC Engine Run Hour Meter Monitor Engine Hours
12V = engine run, 0V = engine off
4 Digital Output 2 12 VDC Key Switch Activation Monitor Machine Utilization
12V = Key SW On, 0V = Key SW
Off
5 Digital Output 3 12 VDC Foot Switch Monitor Machine Utilization
12V = active, 0V = inactive
6 Digital Input 1 12 VDC (standard) Remote Disable Engine Start Remotely Prevent Engine
or ground (optional) Start
7* Databus H CAN HIGH Genie Databus J1939 Engine Messages,
Receive Proprietary Genie
Telematics Message
8* Databus L CAN LOW Genie Databus J1939 Engine Messages,
Receive Proprietary Genie
Telematics Message
* Tier IV engine models only, J1939 engine message available
* Genie proprietary databus support
1 1 1 1
30 87A 30 87A
2 2 12V
12V 3 86 85 4 86 85
SPST
SPST
8 7 6 5
1 2 3 4
Pin Circuit Type Circuit Properties Genie Machine Function(s) Telematics Use Case
1 System Power 24 VDC Battery Positive — constant power Supply power to device
5 Amp Max. allowed
draw
2 System Ground 0 VDC Battery Negative Device Ground
3 Digital Output 1 24 VDC Hour Meter Monitor Machine Run Hours
24V = active, 0V = inactive
4 Digital Output 2 24 VDC Key Switch Activation Monitor Machine Utilization
24V = Key SW On, 0V = Key SW
Off
5 Digital Output 3 24 VDC Foot Switch Monitor Machine Utilization
24V = active, 0V = inactive
6 Digital Input 1 24 VDC (standard) Remote Machine Disable Remote Motor Controller
or Ground (optional) Shutdown
7 No Connection No Connection
8 No Connection No Connection
1 1 1 1
30 87A 30 87A
2 2 24V
24V 3 86 85 4 86 85
SPST
SPST
Genie installed Telematics connector is wired with an Active High digital input.
8 7 6 5
1 2 3 4
Pin Circuit Type Circuit Properties Genie Machine Function(s) Telematics Use Case
1 System Power 24 VDC Battery Positive — constant power Supply power to device
5 Amp Max. allowed
draw
2 System Ground 0 VDC Battery Negative Device Ground
3 Digital Output 1 24 VDC Motor Controller Enable Monitor Machine Run Hours
24V = enabled, 0V = disabled
4 No Connection No Connection
5 No Connection No Connection
6 No Connection No Connection
7* Databus H CAN HIGH Genie Databus Receive Proprietary Genie
Telematics Message
8* Databus L CAN LOW Genie Databus Receive Proprietary Genie
Telematics Message
* Genie proprietary databus support
8 7 6 5
1 2 3 4
Pin Circuit Type Circuit Properties Genie Machine Function(s) Telematics Use Case
1 System Power 24 VDC Battery Positive — constant power Supply power to device
5 Amp Max. allowed
draw
2 System Ground 0 VDC Battery Negative Device Ground
3 No Connection No Connection
4 No Connection No Connection
5 No Connection No Connection
6 No Connection No Connection
7* Databus H CAN HIGH Genie Databus Receive Proprietary Genie
Telematics Message
8* Databus L CAN LOW Genie Databus Receive Proprietary Genie
Telematics Message
* Genie proprietary databus support
Genie installed Telematics connector is wired with an Active High digital input.
8 7 6 5
1 2 3 4
Pin Circuit Type Circuit Properties Genie Machine Function(s) Telematics Use Case
1 System Power 12 VDC Battery Positive — constant power Supply power to device
5 Amp Max. allowed
draw
2 System Ground 0 VDC Battery Negative Device Ground
3 Digital Output 1 12 VDC Engine Run Hour Meter Monitor Engine Hours
12V = engine run, 0V = engine off
4 Digital Output 2 12 VDC Key Switch
12V = Key SW On, 0V = Key SW
Off
5 No Connection No Connection Monitor machine utilization
6 Digital Input 1 12 VDC (standard) Remote Disable Engine Start Remote Engine Shutdown
or ground (optional)
7* Databus H CAN HIGH Genie Databus Receive Proprietary Genie
Telematics Message
8* Databus L CAN LOW Genie Databus Receive Proprietary Genie
Telematics Message
* Tier IV engine models only, J1939 engine message available
* Genie proprietary databus support
1 1 1 1
30 87A 30 87A
2 2 12V
12V 3 86 85 4 86 85
SPST
SPST
8 7 6 5
1 2 3 4
Pin Circuit Type Circuit Properties Genie Machine Function(s) Telematics Use Case
1 System Power 12 VDC Battery Positive — constant power Supply power to device
5 Amp Max. allowed
draw
2 System Ground 0 VDC Battery Negative Device Ground
3 Digital Output 1 12 VDC Engine Run Hour Meter Monitor Engine Hours
12V = engine run, 0V = engine off
4* Digital Output 2 12 VDC Boom Angle Status Monitor Machine Utilization
12V = boom >55°, 0V <55°
5 Digital Output 3 12 VDC Parking Brake Monitor Machine Utilization
12V = active, 0V = inactive
6 Digital Input 1 12 VDC (standard) Remote Disable Engine Start Remotely Prevent Engine
or Ground (optional) Start
7 CAN HIGH J1939 Databus HIGH J1939 Receive J1939 Engine Data
8 CAN LOW J1939 Databus LOW J1939 Receive J1939 Engine Data
* Not available on GTH-636
1 1 1 1
30 87A 30 87A
2 2 12V
12V 3 86 85 4 86 85
SPST
SPST
800.536.1800
Fax 425.883.3475