Technical Service Document for PCB-100-MAIN-10

Checking Power :

1. With the power off, check 16 of JP5 is 14.5 to 14.8V .


2. With the power off, check 18 of JP5 is 5.5V.

3. Check 5 ~ 8 of JP5 is 14.5 ~ 14.8V when the power switch is turned on.
4. Check 12 of JP5 is 24V when the printer button is pressed.

Page 1 / 4
5.

6. Check 3 of U14 is +5.0V.


7. Check 3 of U13 is -5.0V.

Page 2 / 4
8. Check 2 of U39 is 3.3V.

Page 3 / 4
Checking Clocks :

1. Check the clock of U9 for CPU(U6) is 11.0592MHz.


2. Check the clock of U1for CPLD(U2) is 4MHz.
3. Check the clock of U34 for Ethernet LAN (U33) is 25MHz.

How to check whether U23 is working or not. :

1. Check the power (+5V, ground)


2. Check TxD and RxD.

+5VAD
U23
2 44
3 P1.0(T2) VCC 43
4 P1.1(T2EX) P0.0(AD0) 42
5 P1.2 P0.0(AD1) 41
6 P1.3 P0.0(AD2) 40
7 P1.4 P0.3(AD3) 39
8 P1.5 P0.4(AD4) 38
9 P1.6 P0.5(AD5) 37
P1.7 P0.6(AD6) 36
10 P0.7(AD7)
RST 24
RXD 11 P2.0(A8) 25
TXD 13 P3.0(RxD) P2.1(A9) 26
14 P3.1(TxD) P2.2(A10) 27
15 P3.2(/INT0) P2.3(A11) 28
16 P3.3(/INT1) P2.4(A12) 29
17 P3.4(T0) P2.5(A13) 30
18 P3.5(T1) P2.6(A14) 31
19 P3.6(/WR) P2.7(A15)
20 P3.7(/RD) 32
21 XTAL2 /PSEN 33
22 XTAL1 ALE 35
GND /EA
AT89C52_PLCC