WorkedExamplestoBS8110-min Removed
WorkedExamplestoBS8110-min Removed
WorkedExamplestoBS8110-min Removed
Faculty of Engineering
Department of Civil Engineering
Subject:
Reinforced Concrete Design
Worked Example 16 - Shear Wall
Checked by
Unless otherwise A reinforced concrete shear wall carries 𝐺 = 30 KN/m including self-
𝐾
stated, all
references are weight, 𝑄𝐾 = 15 KN/m and wind load 𝑊𝐾 as shown in the figure below.
from: BS8110-1 the wall thickness is 200 mm and the story height is 3m. Design the
wall if grade 30 and 460 are to be used for concrete and all steel
respectively.
Loading
Section 3.2.1.2.2 Fc = (1.4 x 30 + 1.6 x 15) x 5 = 990KN/m length
= 2346.6 𝐾𝑁/𝑚 OK
Section 3.2.1.2.2
Assume critical combination is (1.0 Gk + 1.4 wk)
N = 1.0 x 30 x 5 x 3 = 450 KN
Table 3.19 Referring to table 3.19 in the code the end conditions are condition
1 at top and bottom, so
29
University of Khartoum Job Title
Faculty of Engineering
Department of Civil Engineering
Subject:
Reinforced Concrete Design
Worked Example 17 - Axially loaded footing
Checked by
Size of base
Assume the base weight = 100 KN
Service load = 1000 + 500 + 100 = 1600 KN
Base area = 1600 / 300 = 5.33 m2
Let the base area = 2.4 m x 2.4 m
Base area provided = 5.76 m2
Bending
Section 3.2.1.2.2 ultimate load = 1.4 × 1000 + 1.6 × 500 = 2200 KN
ultimate pressure = 2200 ÷ 5.76 = 382 KN/m2
M 413.7 × 106
Section 3.4.4.4 = = 0.0217
bd fcu 2400 × 4762 × 35
2
K
z = d {0.5 + √(0.25 − )},
0.9
z = 0.95d = 452.2 mm
M 413.7 × 106
AS = = = 2093.5 mm2
0.95fy z 0.95 × 460 × 452.2
Vertical shear
30
Mohamed Elhassan-Civil Engineering Department-UofK
Punching shear
Punching shear is checked on a perimeter 1.5d from the column
face.
31
University of Khartoum Job Title
Faculty of Engineering
Department of Civil Engineering
Subject:
Reinforced Concrete Design
Worked Example 18 - Isolated footing subjected to axial load and moment
Checked by
Unless otherwise A reinforced concrete column 500 mm x 500 mm carries load and
stated, all
references are moment as shown in the table below. Design a square footing to resist
from: BS8110-97 the load if the safe bearing capacity is 300 KN/m2. The concrete is
grade 35 and the reinforcement is grade 460.
Dead 1000 44
Imposed 500 24
Table 3.2 The condition of exposure is moderate for non-aggressive soil. Take
the cover 50 mm.
Size of base
Assume the base weight = 100 KN
Total axial load = 1000 + 500 + 100 = 1600KN
Total moment = 44 + 24 = 68 KN.m
Assume base area = 6.25 m2
the base dimensions = 2.5 m x 2.5 m
total load Moment
pressure P = ±
base area modulus Z
Area = bl
Z = bl2 /6
1600 68 KN
Pmax = + 2
= 282.12 2 < 𝑏𝑒𝑎𝑟𝑖𝑛𝑔 𝑐𝑎𝑝𝑎𝑐𝑖𝑡𝑦 𝑂𝐾
6.25 2.5 × 2.5 /6 m
Bending
Section 3.2.1.2.2 ultimate load = 1.4 × 1000 + 1.6 × 500 = 2200 KN
ultimate moment = 1.4 × 44 + 1.6 × 24 = 100 KN. m
2200 100
ultimate pressure = + = 390.4 KN/m2
6.25 2.53 /6
32
Mohamed Elhassan-Civil Engineering Department-UofK
z = 0.95d = 547.2 mm
M 468.5 × 106
AS = = = 1959.2 mm2
0.95fy z 0.95 × 460 × 547.2
Vertical shear
Punching shear
Punching shear is checked on a perimeter 1.5d from the column
face.
33
View publication stats