GIC Alarm Annunciators
GIC Alarm Annunciators
GIC Alarm Annunciators
• Standard models available from 2 to 48 windows • Four SPDT relay outputs (2 for grouping,
• Choice of 3 window sizes and 6 different 1 for external hooter, 1 for ring back sequence)
window colours • 7 Field selectable operation sequences
• Optically isolated fault inputs with wide fault as per ISA standard
input voltage range (12 - 240V AC/DC +/-10%) • Integral buzzer for audible alarm output of
• Field selection for NO / NC fault input contacts, 80 dB
grouping of alarms, window size configuration • Communication interface with
• Space saving due to lower depth of only 100mm RS485 Modbus RTU protocol
• Integral push buttons for Test, Acknowledge, • Replaceable LEDs, Fast Scan, Manned /
Mute and Reset operations Unmanned, Supervisory Relay & Supply fail
annunciation available
Working Principle
Whenever there is a change of input contacts from Normally Open to Close or from Normally Close to Open position,
annunciator changes from rest condition to alarm condition.
Hence there is an immediate recognition of fault input which will have a corresponding visual and audio alarm as per the
particular selected program sequence.
The base unit of alarm annunciator has four programmable keys for Mute, Acknowledge, Reset & Test function.
On pressing the Mute key the internal buzzer can be deactivated. Acknowledge key is used to accept the fault condition,
Reset key enables to reset the alarm annunciator to its default state and Test key helps to perform the complete test of
the system.
226
Technical Specifications
Parameters Fast Scan Normal Scan
Supply Voltage ( ) 90 - 270 V AC/DC or 18 - 60 V DC
Supply Frequency (AC) 50/60 Hz
LED Indication (Green) ON - Healthy / Manned Mode ON - Healthy
Blinking - Unmanned Mode Blinking - Error [Fast Blinking Rate -
[Slow Blinking Rate - 300msec ON, 3sec OFF] 500msec Cyclic ON/OFF]
Blinking - Error Error:
[Fast Blinking Rate - 500msec Cyclic ON/OFF] 1) User selected wrong windows configuration
Error: 1) User selected wrong windows configuration 2) Number of windows are more than
2) Slave Communication error number of fault inputs.
No. of Windows 2 to 48 windows in different configurations
Window Size Small: 34x31mm, Medium: 68x31mm, Large: 68x63mm
Window Colour Red, Yellow, Blue, Green, Amber and White
Illumination Low power super bright white LEDs Low power super bright white LEDs
(replacable LEDs available)
Fault Input Signal Potential free (NO/NC field selectable)
Fault Input Voltage Internal: 12V DC (Potential free) Internal: 12V DC / External: 12V-270V AC/DC
Scan Time 10 msec 100 msec
Flash Rate 1) Fast flash - 0.5 Sec ON / 0.5 Sec OFF (60 flashes/Min)
2) Slow flash - 0.5 Sec ON / 1.5 Sec OFF (30 flashes/Min)
Terminal Pluggable terminal blocks for conductor up to 2.5mm²
Output Relay Contact 4 C/O Relays (2 for grouping + 1 for external hooter + 1 for Ring back sequence)
Relay Contact Rating NO - 5A / NC - 3A @250V AC & NO - 5A / NC - 3A NO - 5A / NC - 3A @ 250V AC & NO - 5A /
@ 30V DC (resistive), (Relay Actuation time NC - 3A @ 30V DC (resistive), (Relay Actuation
10 to 130ms after signal detection) time 130ms after signal detection)
Audible Alarm Output 80 dB at 1 metre distance (In-built configurable Buzzer)
Facia Type Individual window lens, replaceable from front.
Alarm Sequences As per ISA standard (Field configurable)
1) Manual Reset (M-1) 2) Auto Reset (A-1) 3) Ring Back (R-1-12) 4) Auto Reset with No-lock(A-1-4)
5) Manual reset first out with no subsequent alarm flashing and silence push button (F2M-1)
6) Auto reset first out with no subsequent alarm flashing and silence push button (F2A-1)
7) Manual Reset (M-2) [Applicable for Fast Scan Module]
Push Button Controls Integral Push buttons for Test, Mute, Acknowledge and Reset functions.
Provision of output connections for remote access of push buttons.
Communication Port Computer interface with RS 485 Modbus RTU protocol.
Operating Temperature -10oC to +55oC
Storage Temperature -15oC to +60oC
Humidity 95% R.H.
Mounting Type Panel Mounting
227
Ordering Information
A X XX X X X
Note 1 : For other customised products, use live product configurator available on our website to
generate part number & enquiry request form: www.gicindia.com
228
MOUNTING DIMENSIONS (mm)
100 66
72 16 72
1 2
3 4
138
144
144
1D
144
5 6
7 8
Panel cutout
100 138
144
144 16
1 2 9 10
3 4 11 12
138
2D
144
144
5 6 13 14
144
7 8 15 16
Panel cutout
210
100 216
216 16
1 2 9 10 17 18
3 4 11 12 19 20
138
3D
144
144
144
5 6 13 14 21 22
7 8 15 16 23 24
Panel cutout
282
100
288
288 16
1 2 9 10 17 18 25 26
3 4 11 12 19 20 27 28
138
4D
144
144
144
5 6 13 14 21 22 29 30
7 8 15 16 23 24 31 32
Panel cutout
Weight with box (approx.): 1D=580g, 2D=950g, 3D=1320g, 4D=1690g, 5D=2060g, 6D=2430g
229
CONNECTION DIAGRAM
F9 F9
NO F1 NO F1
P Relay for G2 Alarms.
F2 F10 P Relay for G2 Alarms. F2 F10
It is Fault Follower. It is Fault Follower.
NC F11 NC F11
F3 F3
F12 F12
NO F4 NO F4
P
Relay for G1 Alarms. Up to F13 Relay for G1 Alarms. Up to
F13
It is Fault Follower. F5 Extension 1 P It is Fault Follower. F5 Extension 1
to to
F6 F14 F6 F14
NC Extension 3 NC Extension 3
F15 F15
NO F7 NO F7
Supervisory / Ring F16 Supervisory / Ring F16
P Back Relay
F8 P F8
Back Relay
C FG
NC C NC FG
NO NO
Relay for Hooter. Relay for Hooter.
P It follows internal U/M P It follows internal
buzzer. buzzer.
NC C NC TEST
MANNED /
D+ UNMANNED
RESET
RS-485
D+
D- RS-485 MUTE
D- ACK
GND TEST
RESET
GND C
PUSH BUTTON
MUTE
FOR REMOTE ACCESS
L/+
ACK
L/+ +V
N/-
C
N/- -V
POWER SUPPLY
PUSH BUTTON
FOR REMOTE ACCESS POWER SUPPLY INTERNAL 12V DC, 50 mA
230