Skan C
Skan C
Skan C
7
150,000+
Business
Units
Installations across
the Globe
50+ Installations in
World-class
Products
80+
Countries
80+ Worldwide
Advanced
Technology
600+
Patents
Professionals
Key Features
Exposure
Lamp Dual high definition
LED monitors
1k x 1k High-resolution
Camera
Ergonomic C handles
Rear wheel
with cable
deflector
Hermetically sealed
exposure foot switch
Microprocessor controlled Integrated
high-frequency generator circular collimator
►► Safest C-Arm in its class with virtually very low leakage radiation.
►► 40 - 110 kV and 0.2 - 8 mA in continuous Fluoroscopy and up to 10mA in Snapshot mode: Wide parameter range
covers most procedures including obese patients.
►► 3.5kW (220VAC - 240VAC)/2.2kW (110VAC) RAD mode with high performance switching range from 80 - 250kHz.
►► Pulse Fluoroscopy Mode up to 12mA for good quality images at reduced radiation dose.
►► Vascular Mode with DSA, Pixel Shifting, Trace, and Road Map tools for effective intervention.
►► Image Capture with 1k x 1k resolution for exceptional image quality.
►► Advanced denoising algorithm for improved image quality.
►► Multi-Mode functionality accommodates vascular, pulsed fluoroscopy, RAD, and fluoroscopy.
►► Virtual Collimation allows ROI selection without additional exposure, reducing the dose induced to the patient.
►► Storage of over 100,000 images eliminates the need for constant image backup.
►► Laser Aimer for accurate positioning of the patient, without irradiating.
Procedures
Orthopaedic
►► Closed Reduction Internal Fixation (CRIF).
►► Open Reduction Internal Fixation (ORIF).
►► Hip Fixation.
►► Long Bone Nailing.
►► Vertebroplasty / Kyphoplasty.
►► Bone Biopsy.
►► Intra-articular Steroid Injections.
►► Arthrography.
►► Joint Aspiration.
Pain Management
►► Epidurals
►► Facet Blocks
►► Nerve Blocks
►► Rhizotomies
►► Spinal Cord Stimulator
►► Vertebroplasty / Kyphoplasty
►► RF Ablation
Gastrointestinal
►► Endoscopic Retrograde Cholangiopancreatography.
►► Barium Solvent.
►► Gastric Band Adjustment.
►► Small Bowel Series.
►► Nasojejunal Intubation.
►► Colostomy/Ileostomy Studies.
►► Percutaneous Transhepatic Biliary Drainage (PTBD).
►► Paracentesis and Peritoneal Port Placement.
►► Percutaneous Endoscopic Gastronomy (PEG).
►► Transjugular Liver Biopsy.
►► Laparoscopic Cholangiography.
►► Biliary Stent Placement.
►► Feeding Tube Placement.
Urology
►► Extracorporeal shock wave lithotripsy.
►► Ureteroscopic Lithotripsy (URSL).
►► Percutaneous Nephrolithotomy (PCNL).
►► Cystogram ± Micturating Cystourethrogram.
►► Retrograde Urethrogram.
►► Retrograde Pyelogram.
►► Intravenous Pyelogram (IVP).
►► Urostomy (Ileal Conduit) Studies.
►► Renal Biopsy & Renal Artery Stenting.
Procedures
Neurosurgery
►► Lumbar Puncture & Discectomy.
►► Epidural Steroid Injections.
►► Carotid Artery Stenting.
►► Diagnostic and Therapeutic Spinal.
►► Angiography & Spine Biopsy.
Other Applications
►► Uterine Artery Embolisation / Uterine
Fibroid Embolisation.
►► Hysterosalpingogram (HSG).
►► Varicocele Embolisation.
Multi-Window
►► Multi-Window Interface for reference images.
►► Freeze/Unfreeze option.
Panning
►► The Panning feature allows moving the image
around the canvas.
►► Helpful when the image is zoomed in.
Airkerma on display
►► The total Airkerma for each patient at the normal patient distance from the
X-ray source is displayed along with Dose per procedure, Dose rate, and Dose
Area Product on the Live Monitor.
Other Features
►► Small footprint.
►► Clean power from mains through UPF control.
►► Counterbalanced C for fast and ease of positioning to the clinical need.
►► Overscan/Underscan: -40°/+90°.
►► Length or width determination for screws or tools or bone.
►► Image Intensifier Magnification from 9, 6, and 4.5 inches.
►► Auto Technique for consistent image quality under varying anatomy densities.
►► Image processing includes zoom, flip, invert, torch and median.
►► Image rotation on both active and passive monitors when offline.
►► Snapshot feature to produce similar quality as in Radiography images, in fluoroscopy mode.
►► Image Annotations feature to record and communicate the observations.
►► Studies can be saved in MKV video, JPEG & DCM image formats for publication and sharing.
►► Secure access to sensitive settings to prevent accidental modifications.
►► DICOM 3 Compliant - Send, Receive, Print, DicomCD, MWL, MPPS.
►► Manual and Auto-save option for images and videos.
►► Manual APF table and APR to select kVp and mA.
Dose Reduction Features
Virtual Collimation
►► Virtual simulation of the collimated area without
exposure.
►► Controls soft shutter for dense anatomy display
along with soft tissue.
►► Collimator rotation control to align with the ROI.
Iris Collimation
►► Perfect circular collimation.
►► 9 steps of Iris collimation.
Laser Aimer*
►► Console operated Laser Aimer for accurate
beam positioning.
►► Laser Crosshair on ROI.
►► Precise positioning without continuous
X-ray exposure.
►► Minimizes patient radiation dose by targeting
the area of interest.
►► Reduces radiation to technicians and doctors.
Torch
►► Provides increased image contrast for the
selected area.
►► Helps to enhance the visualization of
tissue areas.
Technical Specifications
X-Ray Tube
X-ray tube type Fixed anode
Nominal Focal Spot Value 0.6/1.8 as per IEC60336
Maximum Anode Heat Capacity 56kHU
Maximum Housing Heat Capacity 1150kHU
Total Filtration >0.1inches of Al eq.
HF X-Ray Generator
Mode of Operation Fluoroscopy, Radiography
Maximum Output in Large Focus [3.5kW (220 - 240V) / 2.2kW (110V)] for 100mS
Maximum Continuous Output in Small Focus 500W [10 min]
kV Range 40 - 110kV
Maximum Tube Current(Large Focus) 70mA @ 50kV, 32mA @ 110kV [220 - 240VAC]
55mA @ 40kV, 20mA @ 110kV [110VAC]
Frequency 80 - 250kHz
Continuous/Pulsed Fluoroscopy
mA Range for Continuous Fluoro 0.2 - 8mA
mA Range for Pulsed Fluoro 0.2 - 12mA
Digital Snap Shot 0.2 - 10mA
Radiography
40 - 110kV, [0.5 to 200mAs (110VAC) / 0.5 - 240mAs
kV and mAs Range
(220 - 240VAC)]
Collimator
Collimation Types Hard & Soft Shutters with Circular IRIS
Mechanical Specifications
Immersion Depth 26 inches
Clear space (free space) 30 inches
Vertical Travel 18 inches
Horizontal Travel 8 inches
Orbital Motion -40° to +90° Max
skanrayamericas.com
Manufactured by:
Skanray Technologies Limited
Reg. Office: #15-17 Hebbal Industrial Area, Mysore - 570016, Karnataka, INDIA. Ph: +91 821 2415559, Fax: +91 821 2403344
Healthcare Division: Plot #360, KIADB Indl. Area, Hebbal, Mysore - 570018, Karnataka, India. Ph: +91 821 2407000, Fax: +91 821 2407001
Skanray continuously upgrades its technology, performance and safety features. Pictures and specifications featured in this catalogue are only indicative.
Please refer to the commercial offer document for exact specifications and performance.
RAD_USA_Draft Rev
MEDICA-NOV2023_US 1
_Skan-C