힐티코리아 - bridge Safety - anchor HSA R2 M16 - 08 용암1교
힐티코리아 - bridge Safety - anchor HSA R2 M16 - 08 용암1교
힐티코리아 - bridge Safety - anchor HSA R2 M16 - 08 용암1교
63
www.hilti.co.kr/r6502279
Company: HILTI KOREA Page: 1
Address: Specifier:
Phone I Fax: 010-9809-0982 | E-Mail: hyunseok.song@hilti.com
Design: bridge safety_anchor HSA R2 M16 Date: 2020. 8. 19.
Fastening point:
Specifier's comments:
1 Input data
Anchor type and diameter: HSA M16 hnom2
Return period (service life in years): 50
Item number: 2004163 HSA M16x137 40/25/-
Effective embedment depth: hef = 80.0 mm, hnom = 92.0 mm
Material:
Evaluation Service Report: ETA 11/0374
Issued I Valid: 2017. 8. 28. | -
Proof: Design Method ETAG (No. 001 Annex C/2010)
Stand-off installation: eb = 0.0 mm (no stand-off); t = 12.0 mm
Anchor plate :
R lx x ly x t = 300.0 mm x 300.0 mm x 12.0 mm; (Recommended plate thickness: not calculated)
Profile: Parallel flange channels Korea, KS 150x75; (L x W x T x FT) = 150.0 mm x 75.0 mm x 6.0 mm x 10.0
mm
Base material: uncracked concrete, 35MPa, fc,cube = 45.00 N/mm ; h = 200.0 mm
2
R
- The anchor calculation is based on a rigid anchor plate assumption.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
1
Hilti PROFIS Engineering 3.0.63
www.hilti.co.kr/r6502279
Company: HILTI KOREA Page: 2
Address: Specifier:
Phone I Fax: 010-9809-0982 | E-Mail: hyunseok.song@hilti.com
Design: bridge safety_anchor HSA R2 M16 Date: 2020. 8. 19.
Fastening point:
Anchor forces are calculated based on the assumption of a rigid anchor plate.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
2
Hilti PROFIS Engineering 3.0.63
www.hilti.co.kr/r6502279
Company: HILTI KOREA Page: 3
Address: Specifier:
Phone I Fax: 010-9809-0982 | E-Mail: hyunseok.song@hilti.com
Design: bridge safety_anchor HSA R2 M16 Date: 2020. 8. 19.
Fastening point:
NRk,s
NSd ≤ NRd,s = ETAG 001 Annex C, Table 5.2.2.1
gM,s
NRk,c
NSd ≤ NRd,c = ETAG 001 Annex C, Table 5.2.2.1
gM,c
0 Ac,N
NRk,c = NRk,c · 0
· y s,N · y re,N · y ec1,N · y ec2,N ETAG 001 Annex C, Eq. (5.2)
Ac,N
0 1,5
NRk,c = k1 · √fck,cube · hef ETAG 001 Annex C, Eq. (5.2a)
0
Ac,N = scr,N · scr,N ETAG 001 Annex C, Eq. (5.2b)
c
y s,N = 0.7 + 0.3 · ≤ 1.00 ETAG 001 Annex C, Eq. (5.2c)
ccr,N
hef
y re,N = 0.5 + ≤ 1.00 ETAG 001 Annex C, Eq. (5.2d)
200
1
y ec1,N = ≤ 1.00 ETAG 001 Annex C, Eq. (5.2e)
2 · ec1,N
1+
scr,N
1
y ec2,N = ≤ 1.00 ETAG 001 Annex C, Eq. (5.2e)
2 · ec2,N
1+
scr,N
2 0 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm]
115,200 57,600 120.0 240.0
Group anchor ID
1, 2
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
3
Hilti PROFIS Engineering 3.0.63
www.hilti.co.kr/r6502279
Company: HILTI KOREA Page: 4
Address: Specifier:
Phone I Fax: 010-9809-0982 | E-Mail: hyunseok.song@hilti.com
Design: bridge safety_anchor HSA R2 M16 Date: 2020. 8. 19.
Fastening point:
VRk,s
VSd ≤ VRd,s = ETAG 001 Annex C, Table 5.2.3.1
gM,s
VRk,cp
VSd ≤ VRd,cp = ETAG 001 Annex C, Table 5.2.3.1
gM,c,p
VRk,cp = k · NRk,c ETAG 001 Annex C, Eq. (5.6)
0 A
NRk,c = NRk,c · 0c,N · y s,N · y re,N · y ec1,N · y ec2,N ETAG 001 Annex C, Eq. (5.2)
Ac,N
0 1,5
NRk,c = k1 · √fck,cube · hef ETAG 001 Annex C, Eq. (5.2a)
0
Ac,N = scr,N · scr,N ETAG 001 Annex C, Eq. (5.2b)
c
y s,N = 0.7 + 0.3 · ≤ 1.00 ETAG 001 Annex C, Eq. (5.2c)
ccr,N
hef
y re,N = 0.5 + ≤ 1.00 ETAG 001 Annex C, Eq. (5.2d)
200
1
y ec1,N = ≤ 1.00 ETAG 001 Annex C, Eq. (5.2e)
2 · ec1,V
1+
scr,N
1
y ec2,N = ≤ 1.00 ETAG 001 Annex C, Eq. (5.2e)
2 · ec2,V
1+
scr,N
2 0 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] k-factor
230,400 57,600 120.0 240.0 2.900
Group anchor ID
1-4
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
4
Hilti PROFIS Engineering 3.0.63
www.hilti.co.kr/r6502279
Company: HILTI KOREA Page: 5
Address: Specifier:
Phone I Fax: 010-9809-0982 | E-Mail: hyunseok.song@hilti.com
Design: bridge safety_anchor HSA R2 M16 Date: 2020. 8. 19.
Fastening point:
a a
bN + bV ≤ 1.0
Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
7 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2018, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering
calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions
explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results
must be checked for agreement with the existing conditions and for plausibility!
• Checking the transfer of loads into the base material is required in accordance with ETAG 001, Annex C(2010)Section 7! The software
considers that the grout is installed under the anchor plate without creating air voids and before application of the loads.
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of ETAG 001, Annex C! For larger
diameters of the clearance hole see Chapter 1.1. of ETAG 001, Annex C!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• The characteristic bond resistances depend on the return period (service life in years): 50
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
5
Hilti PROFIS Engineering 3.0.63
www.hilti.co.kr/r6502279
Company: HILTI KOREA Page: 6
Address: Specifier:
Phone I Fax: 010-9809-0982 | E-Mail: hyunseok.song@hilti.com
Design: bridge safety_anchor HSA R2 M16 Date: 2020. 8. 19.
Fastening point:
8 Installation data
2 2
Anchor plate, steel: S 235; E = 210,000.00 N/mm ; fyk = 235.00 N/mm Anchor type and diameter: HSA M16 hnom2
Profile: Parallel flange channels Korea, KS 150x75; (L x W x T x FT) = 150.0 Item number: 2004163 HSA M16x137 40/25/-
mm x 75.0 mm x 6.0 mm x 10.0 mm
Hole diameter in the fixture: df = 18.0 mm Installation torque: 80 Nm
Plate thickness (input): 12.0 mm Hole diameter in the base material: 16.0 mm
Recommended plate thickness: not calculated Hole depth in the base material: 100.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 160.0 mm
Cleaning: Manual cleaning of the drilled hole according to instructions for use is
required.
Hilti HSA stud anchor with 92 mm embedment, M16 hnom2, Steel galvanized, installationwith torque control bar per ETA 11/0374
y
150.0 150.0
30.0
3 4
150.0
40.0
240.0
x
150.0
1 2
30.0
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
6
Hilti PROFIS Engineering 3.0.63
www.hilti.co.kr/r6502279
Company: HILTI KOREA Page: 7
Address: Specifier:
Phone I Fax: 010-9809-0982 | E-Mail: hyunseok.song@hilti.com
Design: bridge safety_anchor HSA R2 M16 Date: 2020. 8. 19.
Fastening point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan