Hilti PROFIS Engineering 3.0.

63

www.hilti.co.kr/r6502279
Company: HILTI KOREA Page: 1
Address: Specifier:
Phone I Fax: 010-9809-0982 | E-Mail: hyunseok.song@hilti.com
Design: bridge safety_anchor HSA R2 M16 Date: 2020. 8. 19.
Fastening point:

Specifier's comments:

1 Input data
Anchor type and diameter: HSA M16 hnom2
Return period (service life in years): 50
Item number: 2004163 HSA M16x137 40/25/-
Effective embedment depth: hef = 80.0 mm, hnom = 92.0 mm
Material:
Evaluation Service Report: ETA 11/0374
Issued I Valid: 2017. 8. 28. | -
Proof: Design Method ETAG (No. 001 Annex C/2010)
Stand-off installation: eb = 0.0 mm (no stand-off); t = 12.0 mm

Anchor plate :
R lx x ly x t = 300.0 mm x 300.0 mm x 12.0 mm; (Recommended plate thickness: not calculated)

Profile: Parallel flange channels Korea, KS 150x75; (L x W x T x FT) = 150.0 mm x 75.0 mm x 6.0 mm x 10.0
mm
Base material: uncracked concrete, 35MPa, fc,cube = 45.00 N/mm ; h = 200.0 mm
2

Installation: hammer drilled hole, Installation condition: Dry


Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement

R
- The anchor calculation is based on a rigid anchor plate assumption.

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

1
Hilti PROFIS Engineering 3.0.63

www.hilti.co.kr/r6502279
Company: HILTI KOREA Page: 2
Address: Specifier:
Phone I Fax: 010-9809-0982 | E-Mail: hyunseok.song@hilti.com
Design: bridge safety_anchor HSA R2 M16 Date: 2020. 8. 19.
Fastening point:

1.1 Load combination


Case Description Forces [kN] / Moments [kNm] Seismic Fire Max. Util. Anchor [%]
1 Combination 1 N = 0.600; Vx = 0.000; Vy = 10.100; no no 70
Mx = -11.300; My = 0.000; Mz = 0.000;

2 Load case/Resulting anchor forces y


3 4
Compression

Anchor reactions [kN]


Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 22.332 2.525 0.000 2.525
2 22.332 2.525 0.000 2.525 x
3 0.000 2.525 0.000 2.525
4 0.000 2.525 0.000 2.525

max. concrete compressive strain: 0.21 [‰]


max. concrete compressive stress: 6.22 [N/mm ]
2
1 2
resulting tension force in (x/y)=(0.0/-120.0): 44.664 [kN]
resulting compression force in (x/y)=(0.0/134.3): 44.064 [kN] Tension

Anchor forces are calculated based on the assumption of a rigid anchor plate.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

2
Hilti PROFIS Engineering 3.0.63

www.hilti.co.kr/r6502279
Company: HILTI KOREA Page: 3
Address: Specifier:
Phone I Fax: 010-9809-0982 | E-Mail: hyunseok.song@hilti.com
Design: bridge safety_anchor HSA R2 M16 Date: 2020. 8. 19.
Fastening point:

3 Tension load (ETAG, Annex C, Section 5.2.2)


Load [kN] Capacity [kN] Utilization bN [%] Status
Steel Strength* 22.332 59.000 38 OK
Pullout Strength* N/A N/A N/A N/A
Concrete Breakout Failure** 44.664 64.640 70 OK
Splitting failure** N/A N/A N/A N/A

* highest loaded anchor **anchor group (anchors in tension)

3.1 Steel Strength

NRk,s
NSd ≤ NRd,s = ETAG 001 Annex C, Table 5.2.2.1
gM,s

NRk,s [kN] gM,s NRd,s [kN] NSd [kN]


82.600 1.400 59.000 22.332

3.2 Concrete Breakout Failure

NRk,c
NSd ≤ NRd,c = ETAG 001 Annex C, Table 5.2.2.1
gM,c
0 Ac,N
NRk,c = NRk,c · 0
· y s,N · y re,N · y ec1,N · y ec2,N ETAG 001 Annex C, Eq. (5.2)
Ac,N
0 1,5
NRk,c = k1 · √fck,cube · hef ETAG 001 Annex C, Eq. (5.2a)
0
Ac,N = scr,N · scr,N ETAG 001 Annex C, Eq. (5.2b)
c
y s,N = 0.7 + 0.3 · ≤ 1.00 ETAG 001 Annex C, Eq. (5.2c)
ccr,N
hef
y re,N = 0.5 + ≤ 1.00 ETAG 001 Annex C, Eq. (5.2d)
200
1
y ec1,N = ≤ 1.00 ETAG 001 Annex C, Eq. (5.2e)
2 · ec1,N
1+
scr,N
1
y ec2,N = ≤ 1.00 ETAG 001 Annex C, Eq. (5.2e)
2 · ec2,N
1+
scr,N

2 0 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm]
115,200 57,600 120.0 240.0

ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N


0.0 1.000 0.0 1.000 1.000 1.000
0
k1 NRk,c [kN] gM,c NRd,c [kN] NSd [kN]
10.100 48.480 1.500 64.640 44.664

Group anchor ID
1, 2

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

3
Hilti PROFIS Engineering 3.0.63

www.hilti.co.kr/r6502279
Company: HILTI KOREA Page: 4
Address: Specifier:
Phone I Fax: 010-9809-0982 | E-Mail: hyunseok.song@hilti.com
Design: bridge safety_anchor HSA R2 M16 Date: 2020. 8. 19.
Fastening point:

4 Shear load (ETAG, Annex C, Section 5.2.3)


Load [kN] Capacity [kN] Utilization bV [%] Status
Steel Strength (without lever arm)* 2.525 40.800 7 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength** 10.100 374.912 3 OK
Concrete edge failure in direction ** N/A N/A N/A N/A

* highest loaded anchor **anchor group (relevant anchors)

4.1 Steel Strength (without lever arm)

VRk,s
VSd ≤ VRd,s = ETAG 001 Annex C, Table 5.2.3.1
gM,s

VRk,s [kN] gM,s VRd,s [kN] VSd [kN]


51.000 1.250 40.800 2.525

4.2 Pryout Strength

VRk,cp
VSd ≤ VRd,cp = ETAG 001 Annex C, Table 5.2.3.1
gM,c,p
VRk,cp = k · NRk,c ETAG 001 Annex C, Eq. (5.6)
0 A
NRk,c = NRk,c · 0c,N · y s,N · y re,N · y ec1,N · y ec2,N ETAG 001 Annex C, Eq. (5.2)
Ac,N
0 1,5
NRk,c = k1 · √fck,cube · hef ETAG 001 Annex C, Eq. (5.2a)
0
Ac,N = scr,N · scr,N ETAG 001 Annex C, Eq. (5.2b)
c
y s,N = 0.7 + 0.3 · ≤ 1.00 ETAG 001 Annex C, Eq. (5.2c)
ccr,N
hef
y re,N = 0.5 + ≤ 1.00 ETAG 001 Annex C, Eq. (5.2d)
200
1
y ec1,N = ≤ 1.00 ETAG 001 Annex C, Eq. (5.2e)
2 · ec1,V
1+
scr,N
1
y ec2,N = ≤ 1.00 ETAG 001 Annex C, Eq. (5.2e)
2 · ec2,V
1+
scr,N

2 0 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] k-factor
230,400 57,600 120.0 240.0 2.900

ec1,V [mm] y ec1,N ec2,V [mm] y ec2,N y s,N y re,N


0.0 1.000 0.0 1.000 1.000 1.000
0
NRk,c [kN] gM,c,p VRd,cp [kN] VSd [kN]
48.480 1.500 374.912 10.100

Group anchor ID
1-4

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

4
Hilti PROFIS Engineering 3.0.63

www.hilti.co.kr/r6502279
Company: HILTI KOREA Page: 5
Address: Specifier:
Phone I Fax: 010-9809-0982 | E-Mail: hyunseok.song@hilti.com
Design: bridge safety_anchor HSA R2 M16 Date: 2020. 8. 19.
Fastening point:

5 Combined tension and shear loads (ETAG, Annex C, Section 5.2.4)


Steel failure

bN bV a Utilization bN,V [%] Status


0.691 0.062 1.500 59 OK

a a
bN + bV ≤ 1.0

6 Displacements (highest loaded anchor)


Short term loading:

NSk = 16.542 [kN] dN = 1.2503 [mm]


VSk = 1.870 [kN] dV = 0.1414 [mm]
dNV = 1.2582 [mm]
Long term loading:

NSk = 16.542 [kN] dN = 1.6350 [mm]


VSk = 1.870 [kN] dV = 0.2121 [mm]
dNV = 1.6487 [mm]

Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!

The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

7 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2018, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering
calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions
explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results
must be checked for agreement with the existing conditions and for plausibility!
• Checking the transfer of loads into the base material is required in accordance with ETAG 001, Annex C(2010)Section 7! The software
considers that the grout is installed under the anchor plate without creating air voids and before application of the loads.
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of ETAG 001, Annex C! For larger
diameters of the clearance hole see Chapter 1.1. of ETAG 001, Annex C!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• The characteristic bond resistances depend on the return period (service life in years): 50

Fastening meets the design criteria!

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

5
Hilti PROFIS Engineering 3.0.63

www.hilti.co.kr/r6502279
Company: HILTI KOREA Page: 6
Address: Specifier:
Phone I Fax: 010-9809-0982 | E-Mail: hyunseok.song@hilti.com
Design: bridge safety_anchor HSA R2 M16 Date: 2020. 8. 19.
Fastening point:

8 Installation data
2 2
Anchor plate, steel: S 235; E = 210,000.00 N/mm ; fyk = 235.00 N/mm Anchor type and diameter: HSA M16 hnom2
Profile: Parallel flange channels Korea, KS 150x75; (L x W x T x FT) = 150.0 Item number: 2004163 HSA M16x137 40/25/-
mm x 75.0 mm x 6.0 mm x 10.0 mm
Hole diameter in the fixture: df = 18.0 mm Installation torque: 80 Nm
Plate thickness (input): 12.0 mm Hole diameter in the base material: 16.0 mm
Recommended plate thickness: not calculated Hole depth in the base material: 100.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 160.0 mm
Cleaning: Manual cleaning of the drilled hole according to instructions for use is
required.

Hilti HSA stud anchor with 92 mm embedment, M16 hnom2, Steel galvanized, installationwith torque control bar per ETA 11/0374

8.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Manual blow-out pump • Installation torque control bar with suitable
• Properly sized drill bit screw driver or torque wrench
• Hammer

y
150.0 150.0
30.0

3 4
150.0
40.0

240.0

x
150.0

1 2
30.0

30.0 240.0 30.0

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y
1 -120.0 -120.0 - - - -
2 120.0 -120.0 - - - -
3 -120.0 120.0 - - - -
4 120.0 120.0 - - - -

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

6
Hilti PROFIS Engineering 3.0.63

www.hilti.co.kr/r6502279
Company: HILTI KOREA Page: 7
Address: Specifier:
Phone I Fax: 010-9809-0982 | E-Mail: hyunseok.song@hilti.com
Design: bridge safety_anchor HSA R2 M16 Date: 2020. 8. 19.
Fastening point:

9 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted
prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the
data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be
put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly
with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or
suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

You might also like