You are on page 1of 17

Hilti PROFIS Engineering 3.0.

85

www.hilti.co.za
Company: Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Apr 24, 2023 (2) Date: 2023/04/24
Fastening point:

Specifier's comments:

1 Anchor Design
1.1 Input data

Anchor type and diameter: HIT-HY 200 + HAS-U 5.8 M10


Return period (service life in years): 50
Item number: 2223705 HAS-U 5.8 M10x95 (element) / 2022696
HIT-HY 200-A (adhesive)
Effective embedment depth: hef,opti = 60.0 mm (hef,limit = 200.0 mm)
Material: 5.8
Evaluation Service Report: ETA 11/0493
Issued I Valid: 2021/12/10 | -
Proof: Design Method EN 1992-4, Chemical
Stand-off installation: eb = 0.0 mm (no stand-off); t = 8.0 mm

Anchor plate
CBFEM
: lx x ly x t = 69.3 mm x 103.0 mm x 8.0 mm;

Profile: U profile, U 100; (L x W x T x FT) = 100.0 mm x 50.0 mm x 6.0 mm x 8.5 mm


Base material: 2
cracked concrete, C25/30, fc,cyl = 25.00 N/mm ; h = 250.0 mm, Temp. short/long: 50/30 °C,
User-defined partial material safety factor gc = 1.500
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement

CBFEM
- The anchor calculation is based on a component-based Finite Element Method (CBFEM)

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

1
Hilti PROFIS Engineering 3.0.85

www.hilti.co.za
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Apr 24, 2023 (2) Date: 2023/04/24
Fastening point:

1.1.1 Load combination


Case Description Forces [kN] / Moments [kNm] Seismic Fire Max. Util. Anchor [%]
1 Combination 1 N = 0.000; Vx = 0.000; Vy = 1.950; no no 91
Mx = 0.500; My = 0.000; Mz = 0.000;
Nsus = 0.000; Mx,sus = 0.000; My,sus = 0.000;

1.2 Load case/Resulting anchor forces y

Anchor reactions [kN] 2


Tension force: (+Tension, -Compression) Tension
Anchor Tension force Shear force Shear force x Shear force y
1 0.000 0.981 0.154 0.969
2 6.998 0.993 -0.154 0.981 x

1
resulting tension force in (x/y)=(-4.0/30.7): 6.998 [kN]
resulting compression force in (x/y)=(-5.0/-42.9): 7.062 [kN]

Anchor forces are calculated based on a component-based Finite Element Method (CBFEM)
Compression

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

2
Hilti PROFIS Engineering 3.0.85

www.hilti.co.za
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Apr 24, 2023 (2) Date: 2023/04/24
Fastening point:

1.3 Tension load (EN 1992-4, Section 7.2.1)

Load [kN] Capacity [kN] Utilization bN [%] Status


Steel Strength* 6.998 19.333 37 OK
Combined pullout-concrete cone failure** 6.998 7.710 91 OK
Concrete Breakout Failure** 6.998 14.102 50 OK
Splitting failure** N/A N/A N/A N/A

* highest loaded anchor **anchor group (anchors in tension)

1.3.1 Steel Strength

N
NEd £ NRd,s = Rk,s EN 1992-4, Table 7.1
gM,s

NRk,s [kN] gM,s NRd,s [kN] NEd [kN]


29.000 1.500 19.333 6.998

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

3
Hilti PROFIS Engineering 3.0.85

www.hilti.co.za
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Apr 24, 2023 (2) Date: 2023/04/24
Fastening point:

1.3.2 Combined pullout-concrete cone failure

N
NEd £ NRd,p = Rk,p EN 1992-4, Table 7.1
gM,p
0 Ap,N
NRk,p = NRk,p · 0
· y g,Np · y s,Np · y re,N · y ec1,Np · y ec2,Np EN 1992-4, Eq. (7.13)
Ap,N
0
NRk,p = y sus · t Rk · p · d · hef EN 1992-4, Eq. (7.14)
y sus =1 EN 1992-4, Eq. (7.14a)

scr,Np = 7.3 · d · √y sus · t Rk £ 3 · hef EN 1992-4, Eq. (7.15)


0,5
y g,Np
0
= y g,Np -
s
s
( ) · (y g,Np - 1) ³ 1.00
cr,Np
0
EN 1992-4, Eq. (7.17)
1,5
0
y g,Np = √n - (√n - 1) · (tt )
Rk

Rk,c
³ 1.00 EN 1992-4, Eq. (7.18)
k3
t Rk,c = · √hef · fck EN 1992-4, Eq. (7.19)
p·d
c
y s,Np = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.20)
ccr,Np £
1
y ec1,Np = 1.00 EN 1992-4, Eq. (7.21)
2 · ec1,N £
1+ (
scr,Np )
1
y ec2,Np = 1.00 EN 1992-4, Eq. (7.21)
2 · ec2,N £
1+ (
scr,Np )
2 0 2 2 2
Ap,N [mm ] Ap,N [mm ] t Rk,ucr,20 [N/mm ] scr,Np [mm] ccr,Np [mm] cmin [mm] fc,cyl [N/mm ]
32,400 32,400 15.00 180.0 90.0 196.0 25.00
0
yc t Rk,cr [N/mm ]
2
k3 t Rk,c [N/mm ]
2
y g,Np y g,Np
1.023 6.14 7.700 9.49 1.000 1.000

ec1,N [mm] y ec1,Np ec2,N [mm] y ec2,Np y s,Np y re,Np


0.0 1.000 0.0 1.000 1.000 1.000
0
y sus asus y sus
0.890 0.000 1.000
0
NRk,p [kN] NRk,p [kN] gM,p NRd,p [kN] NEd [kN]
11.565 11.565 1.500 7.710 6.998

Group anchor ID
2

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

4
Hilti PROFIS Engineering 3.0.85

www.hilti.co.za
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Apr 24, 2023 (2) Date: 2023/04/24
Fastening point:

1.3.3 Concrete Breakout Failure

N
NEd £ NRd,c = Rk,c EN 1992-4, Table 7.1
gM,c
0 Ac,N
NRk,c = NRk,c · 0
· y s,N · y re,N · y ec1,N · y ec2,N · y M,N EN 1992-4, Eq. (7.1)
Ac,N
0 1,5
NRk,c = k1 · √fck · hef EN 1992-4, Eq. (7.2)
0
Ac,N = scr,N · scr,N EN 1992-4, Eq. (7.3)
c
y s,N = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.4)
ccr,N £
1
y ec1,N = 1.00 EN 1992-4, Eq. (7.6)
2 · eN,1 £
1+ (
scr,N )
1
y ec2,N = 1.00 EN 1992-4, Eq. (7.6)
2 · eN,2 £
1+ (
scr,N )
z
y M,N = 2.0 - 1.00 EN 1992-4, Eq. (7.7)
1.5 · hef ³

2 0 2 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] fc,cyl [N/mm ]
32,400 32,400 90.0 180.0 25.00

ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N


0.0 1.000 0.0 1.000 1.000 1.000
0
z [mm] y M,N k1 NRk,c [kN] gM,c NRd,c [kN] NEd [kN]
73.6 1.182 7.700 17.893 1.500 14.102 6.998

Group anchor ID
2

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

5
Hilti PROFIS Engineering 3.0.85

www.hilti.co.za
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Apr 24, 2023 (2) Date: 2023/04/24
Fastening point:

1.4 Shear load (EN 1992-4, Section 7.2.2)

Load [kN] Capacity [kN] Utilization bV [%] Status


Steel Strength (without lever arm)* 0.993 13.920 8 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength* 0.993 9.882 11 OK
Concrete edge failure in direction y+** 1.956 13.123 15 OK

* highest loaded anchor **anchor group (relevant anchors)

1.4.1 Steel Strength (without lever arm)

V
VEd £ VRd,s = Rk,s EN 1992-4, Table 7.2
gM,s
0
VRk,s = k7 · VRk,s EN 1992-4, Eq. (7.35)

0
VRk,s [kN] k7 VRk,s [kN] gM,s VRd,s [kN] VEd [kN]
17.400 1.000 17.400 1.250 13.920 0.993

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

6
Hilti PROFIS Engineering 3.0.85

www.hilti.co.za
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Apr 24, 2023 (2) Date: 2023/04/24
Fastening point:

1.4.2 Pryout Strength (Bond Strength controls)

V
VEd £ VRd,cp = Rk,cp EN 1992-4, Table 7.2
gM,c,p
VRk,cp = k8 · min {NRk,c; NRk,p} EN 1992-4, Eq. (7.39c)
0 A
NRk,p = NRk,p · 0p,N · y g,Np · y s,Np · y re,N · y ec1,Np · y ec2,Np EN 1992-4, Eq. (7.13)
Ap,N
0
NRk,p = y sus · t Rk · p · d · hef EN 1992-4, Eq. (7.14)
y sus =1 EN 1992-4, Eq. (7.14a)
scr,Np = 7.3 · d · √y sus · t Rk £ 3 · hef EN 1992-4, Eq. (7.15)
0,5
y g,Np
0
= y g,Np - (s s )
cr,Np
· (y g,Np - 1) ³ 1.00
0
EN 1992-4, Eq. (7.17)
1,5
0
y g,Np = √n - (√n - 1) · (tt ) Rk

Rk,c
³ 1.00 EN 1992-4, Eq. (7.18)
k3
t Rk,c = · √hef · fck EN 1992-4, Eq. (7.19)
p·d
c
y s,Np = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.20)
ccr,Np £
1
y ec1,Np = 1.00 EN 1992-4, Eq. (7.21)
2 · ec1,N £
1+ (
scr,Np )
1
y ec2,Np = 1.00 EN 1992-4, Eq. (7.21)
2 · ec2,N £
1+ (
scr,Np )
2 0 2 2 2
Ap,N [mm ] Ap,N [mm ] t Rk,ucr,20 [N/mm ] ccr,Np [mm] scr,Np [mm] cmin [mm] fc,cyl [N/mm ]
20,765 32,400 15.00 90.0 180.0 196.0 25.00
0
yc t Rk,cr [N/mm ]
2
k3 t Rk,c [N/mm ]
2
k8 y g,Np

1.023 6.14 7.700 9.49 2.000 0.000

y g,Np ec1,V [mm] y ec1,Np ec2,V [mm] y ec2,Np y s,Np


1.000 0.0 1.000 0.0 1.000 1.000
0
y re,Np y sus asus y sus
1.000 0.890 0.000 1.000
0
NRk,p [kN] NRk,p [kN] gM,c,p VRd,cp [kN] VEd [kN]
11.565 7.412 1.500 9.882 0.993

Group anchor ID
2

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

7
Hilti PROFIS Engineering 3.0.85

www.hilti.co.za
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Apr 24, 2023 (2) Date: 2023/04/24
Fastening point:

1.4.3 Concrete edge failure in direction y+

V
VEd £ VRd,c = Rk,c EN 1992-4, Table 7.2
gM,c
0 Ac,V
VRk,c = kT · VRk,c · 0
· y s,V · y h,V · y a,V · y ec,V · y re,V EN 1992-4, Eq. (7.40)
Ac,V
0 a b 1,5
VRk,c = k9 · dnom · lf · √fck · c1 EN 1992-4, Eq. (7.41)
0,5
a = 0.1 · () lf
c1
EN 1992-4, Eq. (7.42)
0,2

= 0.1 · (
c )
d nom
b EN 1992-4, Eq. (7.43)
1
0 2
Ac,V = 4.5 · c1 EN 1992-4, Eq. (7.44)
c2
y s,V = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.45)
1.5 · c1 £
0,5
y h,V = (1.5h· c ) 1
³ 1.00 EN 1992-4, Eq. (7.46)
1
y ec,V = £ 1.00 EN 1992-4, Eq. (7.47)
1+ ( 2 · eV
3 · c1 )
y a,V = √(cos a ) + (10.5 · sin a )
V
2
V
2 ³ 1.00 EN 1992-4, Eq. (7.48)

'
c1 = max (c1.5 , 1.5h , s 3 )
2,max 2,max
EN 1992-4, Eq. (7.50)

lf [mm] dnom [mm] k9 a b 2


fc,cyl [N/mm ]
60.0 10.00 1.700 0.060 0.057 25.00
' 2 0 2
c1 [mm] c1 [mm] Ac,V [mm ] Ac,V [mm ]
570.0 166.7 99,000 125,000

y s,V y h,V y a,V ec,V [mm] y ec,V y re,V


0.935 1.000 1.002 0.0 1.000 1.000
0
VRk,c [kN] kT gM,c VRd,c [kN] VEd [kN]
26.515 1.0 1.500 13.123 1.956

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

8
Hilti PROFIS Engineering 3.0.85

www.hilti.co.za
Company: Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Apr 24, 2023 (2) Date: 2023/04/24
Fastening point:

1.5 Combined tension and shear loads (EN 1992-4, Section 7.2.3)
Steel failure

bN bV a Utilization bN,V [%] Status


0.362 0.071 2.000 14 OK

a a
bN + bV £ 1.0

Concrete failure

bN bV a Utilization bN,V [%] Status


0.908 0.149 1.000 89 OK

(bN + bV) / 1.2 £ 1.0

1.6 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates as per current regulations (ETAG 001/Annex C, EOTA
TR029, etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor
plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates
the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above.
The proof if the rigid base plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for
agreement with the existing conditions and for plausibility!
• Checking the transfer of loads into the base material is required in accordance with EN 1992-4, Annex A!
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 6.1 of EN 1992-4! For larger diameters
of the clearance hole see section 6.2.2 of EN 1992-4!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• For the determination of the y re,v (concrete edge failure) the minimum concrete cover defined in the design settings is used as the concrete
cover of the edge reinforcement.
• Bore hole cleaning must be performed according to instructions for use (blow twice with oil-free compressed air (min. 6 bar), brush twice,
blow twice with oil-free compressed air (min. 6 bar)).
• Characteristic bond resistances depend on short- and long-term temperatures.
• Edge reinforcement is not required to avoid splitting failure
• The anchor design methods in PROFIS Engineering require rigid anchor plates, as per current regulations (AS 5216:2021, ETAG 001/Annex
C, EOTA TR029 etc.). This means that the anchor plate should be sufficiently rigid to prevent load re-distribution to the anchors due to
elastic/plastic displacements. The user accepts that the anchor plate is considered close to rigid by engineering judgment."
• The characteristic bond resistances depend on the return period (service life in years): 50

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

9
Hilti PROFIS Engineering 3.0.85

www.hilti.co.za
Company: Page: 10
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Apr 24, 2023 (2) Date: 2023/04/24
Fastening point:

1.7 Installation data


2 2
Anchor plate, steel: S 235; E = 210,000.00 N/mm ; fyk = 235.00 N/mm Anchor type and diameter: HIT-HY 200 + HAS-U 5.8 M10
Profile: U profile, U 100; (L x W x T x FT) = 100.0 mm x 50.0 mm x 6.0 mm x Item number: 2223705 HAS-U 5.8 M10x95 (element) /
8.5 mm 2022696 HIT-HY 200-A (adhesive)
Hole diameter in the fixture: df = 12.0 mm Maximum installation torque: 20 Nm
Plate thickness (input): 8.0 mm Hole diameter in the base material: 12.0 mm
Hole depth in the base material: 60.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 100.0 mm
Cleaning: Compressed air cleaning of the drilled hole according to instructions
for use is required

Hilti HAS-U threaded rod with HIT-HY 200 injection mortar with 60 mm embedment h_ef, M10, Steel galvanized, Hammer drilled installation
per ETA 11/0493

1.7.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Compressed air with required • Dispenser including cassette and mixer
• Properly sized drill bit accessories to blow from the bottom of • Torque wrench
the hole
• Proper diameter wire brush

y
34.6 34.6
20.8

2
51.5
50.7

1
51.5
31.5

30.6 38.6

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y
1 -4.0 -20.0 196.0 200.0 570.0 620.7
2 -4.0 30.7 196.0 200.0 620.7 570.0

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

10
Hilti PROFIS Engineering 3.0.85

www.hilti.co.za
Company: Page: 11
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Apr 24, 2023 (2) Date: 2023/04/24
Fastening point:

2 Anchor plate design

2.1 Input data


Anchor plate: Shape: Rectangular
lx x ly x t = 69.3 mm x 103.0 mm x 8.0 mm
Calculation: CBFEM
Material: S 235; Fy = 235.00 N/mm²; εlim = 5.00%
Anchor type and size: HIT-HY 200 + HAS-U 5.8 M10, hef = 60.0 mm
Anchor stiffness: The anchor is modeled considering stiffness values determined from load displacement curves tested in an
independent laboratory. Please note that no simple replacement of the anchor is possible as the anchor
stiffness has a major impact on the load distribution results.
Design method: EN-based design using component-based FEM
Stand-off installation: eb = 0.0 mm (No stand-off); t = 8.0 mm
Profile: U 100; (L x W x T x FT) = 100.0 mm x 50.0 mm x 6.0 mm x 8.5 mm
Material: S 235; Fy = 235.00 N/mm²; εlim = 5.00%
Eccentricity x: 0.0 mm
Eccentricity y: 0.0 mm
Base material: Cracked concrete; C25/30; fc,cyl = 25.00 N/mm²; h = 250.0 mm; E = 31,000.00 N/mm²; G = 12,916.67
N/mm²; v = 0.20
Welds (profile to anchor plate): Type of redistribution: Plastic
Material: S 235
Mesh size: Number of elements on edge: 8
Min. size of element: 10.0 mm
Max. size of element: 50.0 mm

2.2 Summary
Description Profile Anchor plate Concrete [%]
sEd [N/mm²] ePl [%] sEd [N/mm²] ePl [%] Hole bearing [%]
1 Combination 1 48.63 0.00 68.53 0.00 2 14
2.3 Anchor plate classification
Results below are displayed for the decisive load combinations: Combination 1
Anchor tension forces Equivalent rigid anchor plate (CBFEM) Component-based Finite Element Method
(CBFEM) anchor plate design
Anchor 1 0.000 kN 0.000 kN
Anchor 2 7.032 kN 6.998 kN

User accepted to consider the selected anchor plate as rigid by his/her engineering judgement. This means the anchor design guidelines can
be applied.

2.4 Profile/Stiffeners/Plate
Profile and stiffeners are verified at the level of the steel to concrete connection. The connection design does not replace the steel design for
critical cross sections, which should be performed outside of PROFIS Engineering.

2.4.1 Equivalent stress and plastic strain


Limit state criteria as per EN1993-1-5 Annex C.8, (1) 2.

Results
Part Load Material sEd [N/mm²] ePl [%] fy [N/mm²] gM0 fy/gM0 elim [%] Status
combination [N/mm²]
Plate Combination S 235 68.53 0.00 235.00 1.00 235.00 5.00 OK
1
Profile Combination S 235 48.63 0.00 235.00 1.00 235.00 5.00 OK
1
Profile Combination S 235 31.76 0.00 235.00 1.00 235.00 5.00 OK

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

11
Hilti PROFIS Engineering 3.0.85

www.hilti.co.za
Company: Page: 12
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Apr 24, 2023 (2) Date: 2023/04/24
Fastening point:

Part Load Material sEd [N/mm²] ePl [%] fy [N/mm²] gM0 fy/gM0 elim [%] Status
combination [N/mm²]
1
Profile Combination S 235 45.23 0.00 235.00 1.00 235.00 5.00 OK
1

2.4.1.1 Equivalent stress


Results below are displayed for the decisive load combination: 1 - Combination 1

235.00 N/mm²

0.00 N/mm²

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

12
Hilti PROFIS Engineering 3.0.85

www.hilti.co.za
Company: Page: 13
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Apr 24, 2023 (2) Date: 2023/04/24
Fastening point:

2.4.1.2 Plastic strain


Results below are displayed for the decisive load combination: 1 - Combination 1

5.00%

0.00%
2.4.2 Hole bearing
Decisive load combination: 1 - Combination 1
Plate hole bearing resistance, EN1993-1 - 8 section 3.6.1:

Equations

k1 ab fu d t
Fb,Rd =
gM2
VEd
Utilization =
Fb,Rd

Variables
k1 ab fu [N/mm²] d [mm] t [mm] gM2
Anchor 1 2.50 0.89 360.00 10.0 8.0 1.25
Anchor 2 2.50 1.00 360.00 10.0 8.0 1.25

Results
VEd [kN] Fb,Rd [kN] Utilization [%] Status
Anchor 1 0.981 51.031 2 OK
Anchor 2 0.993 57.600 2 OK

2.5 Concrete
Decisive load combination: 1 - Combination 1
According to EN1992-1-1 section 6.7(4), the concrete should have sufficient reinforcement to take into account the tensile forces that develop
due to the fixture attachment. The definition of the reinforcement in the concrete is out of scope of PROFIS Engineering.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

13
Hilti PROFIS Engineering 3.0.85

www.hilti.co.za
Company: Page: 14
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Apr 24, 2023 (2) Date: 2023/04/24
Fastening point:

2.5.1 Compression in concrete under the anchor plate


7.71 N/mm²

0.00 N/mm²

2.5.2 Verification of compression in concrete under the anchor plate around the profile as per EN1992-1 section 6.7 and EN1993-1-8,
section 6.2.5

Equations

fjd
bj kj acc fck
=
gc
N
s = Aeff

Utilization =
s
fjd

Variables
N [kN] Aeff [mm²] bj kj acc fck [N/mm²] gc
7.062 1,567 0.67 3.00 1.00 25.00 1.50

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

14
Hilti PROFIS Engineering 3.0.85

www.hilti.co.za
Company: Page: 15
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Apr 24, 2023 (2) Date: 2023/04/24
Fastening point:

Results
s [N/mm²] fjd [N/mm²] Utilization [%] Status
4.51 33.50 14 OK

2.6 Symbol explanation


ab Factor
acc Long-term effects on maximum strength of concrete
Aeff Effective area
bj Joint coefficient βj
d Nominal diameter of the bolt
elim Limit plastic strain
ePl Plastic strain from CBFEM results
Fb,Rd Plate bearing resistance EN 1993-1-8 tab. 3.4
fck Characteristic compressive concrete strength
fjd The ultimate bearing strength of the concrete block
fu Ultimate strength
fy Yield strength
gc Service factor - SP 16, Table 41
gM0 Steel safety factor gamma M0
gM2 Steel safety factor gamma M2
k1 Factor for edge distance and bolt spacing perpendicular to the direction of load transfer - EN 1993-1-8 - Table 3.4
kj Concentration factor
N Resulting compression force
s Average stress in concrete
sEd Equivalent stress
t Thickness of the anchor plate
VEd Anchor shear force

2.7 Warnings
● By using the CBFEM calculation functionality of PROFIS Engineering you may act outside the applicable design codes and your specified
anchor plate may not behave rigid. Please, validate the results with a professional designer and/or structural engineer to ensure suitability
and adequacy for your specific jurisdiction and project requirements.
● The anchor is modeled considering stiffness values determined from load displacement curves tested in an independent laboratory.
Please note that no simple replacement of the anchor is possible as the anchor stiffness has a major impact on the load distribution
results.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

15
Hilti PROFIS Engineering 3.0.85

www.hilti.co.za
Company: Page: 16
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Apr 24, 2023 (2) Date: 2023/04/24
Fastening point:

3 Summary of results
Design of the anchor plate, anchor, welds and other elements are based on CBFEM (component based finite element method) and Eurocode
regulations.
Load combination Max. utilization Status
Anchors Combination 1 91% OK
Anchor plate Combination 1 30% OK
Concrete Combination 1 14% OK
Profile Combination 1 21% OK

Fastening meets the design criteria!

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

16
Hilti PROFIS Engineering 3.0.85

www.hilti.co.za
Company: Page: 17
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Apr 24, 2023 (2) Date: 2023/04/24
Fastening point:

4 Remarks; Your Cooperation Duties


● Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles,
formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc.,
that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be
conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based
essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the
relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and
cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility.
The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and
the relevance of the results or suitability for a specific application.
● You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you
do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the
Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery
of lost or damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

17

You might also like