Intelis C&I EN Web
Intelis C&I EN Web
Intelis C&I EN Web
Intelis C&I is a meter designed to measure water to light commercial and industrial customers. Ideal for
billing, it leverages ultrasonic technology to offer precise measurements at all flow rates. Agile, it proves
equally valuable in district metering, set up ahead of residential networks to monitor water losses before
individual counting. Robust alternative to traditional mechanical meters of large diameters (DN 50 -
200), Intelis C&I’s technology offers a hassle-free option for heavy water clients.
INTELIS C&I IS LOW MAINTENANCE INTELIS C&I HELPS MONITOR WATER Technology
Relying on ultrasonic technology, Intelis LOSSES » Dual beam ultrasonic technology
C&I has no moving parts in comparison Intelis C&I goes beyond billing and brings adapted to large DN sizes
to mechanical meters, thus maintaining ultrasonic precision to district metering » Free bore hole diameter for very low
a high level of accuracy over its entire applications. Ahead of residential pressure loss
lifecycle with low to no field maintenance distribution networks, Intelis helps monitor
» Insensitive to harsh water conditions,
for utilities. water flows, improving the identification of
pressure peaks and peak flows for long
water losses.
lasting accuracy performances
INTELIS C&I SIMPLIFIES DATA
COLLECTION FEATURES » Capable of installation in any position
Compatible with Itron’s Cyble* technology » Highly accurate at both high and low
Communication
through pulse outputs, Intelis C&I flow rate
connects to wireless data collection » Pulse output for volume and flow
» IP68, compatible with pit conditions
systems to provide an accurate reading of direction
» Battery lifetime up to 15 years, based
water consumption. » 2-Pulse Option Available
on environmental conditions
» Ultrasonic technology resistant to the
Approval and Standards
adhesion of dirt and contaminants
» MID, Directive 2014/32/EU,
» Flow Measurement Bi-directional /
» ROHS 2 2011/65/EU
cumulated index
» ACS certification (compliance for
potable drinking water)
* With external communication module through pulse outputs (Itron’s or 3rd party).
WATER
TECHNOLOGY DESCRIPTION
5 4
DISPLAY DESCRIPTION
2 3 4 5 6 7
Intelis C&I features a pulse output for volume and flow direction with the following characteristics:
Intelis C&I is compatible through pulse output and remote modules with Itron mobile and
cellular solutions Pulse Anyquest & Watermind V2.
METROLOGICAL CHARACTERISTICS
Nominal Diameter DN mm 50 65 80 100 125 150 200
inches 2 2 1/2 3 4 5 6 8
Permanent flowrate Q3 m /h
3
40 63 63 100 150 250 400
Approved Ratio R 500
Overload flowrate Q4 m3/h 50 80 80 125 200 313 500
Minimum flowrate Q1 l/h 80 126 126 200 300 500 800
Starting flowrate l/h 20 31 31 50 78 125 200
Cut-off flowrate m /h
3
60 100 100 150 250 400 600
Maximum pressure MAP bar 16
Metrological Water
mAT - MAT +0.1°C .... +50°C
Temperature Range
Sensitivity class U0/D0
Pressure loss class 0.16
Maximum Admissible Water temperature +55°C
PRESSURE LOSS
1,00
DN50 - Q3 = 40
0.10
DN65 - Q3 = 63
Pressure Loss (bar)
DN80 - Q3 = 63
DN100 - Q3 = 100
DN125 - Q3 = 150
0.01
DN150 - Q3 = 250
DN200 - Q3 = 400
0.00
1 10 100 1000
Flow-rate (m3/h)
DIMENSIONS AND WEIGHT
Nominal Diameter mm 50 65 80 100 125 150 200
DN inches 2 2 1/2 3 4 5 6 8
Total length (L) mm 200 200 225 250 250 300 350
Flanging ISO PN10/16 ISO PN10
or PN16
Height (H1) mm 77 85 95 103 115 126 190
Total Height (H) mm 182 198.5 215.5 233.5 259.5 275.5 360
Flange diameter (W) mm 165 185 200 220 240 260 340
Housing diameter (L1) mm 110 110 110 110 110 110 110
Weight (kg) mm 10 12 13 15 18 20.5 26