The Thermo Scientific DCT6088

Product Specifications
advanced transit time flowmeter
employs a unique digital correlation
technique to reliably measure the flow
of clean liquids. Designed for use
on pipes of all sizes, the non-intrusive
device is easy-to-install, simple
to operate, and eliminates pressure
loss and leakage which reduces
downtime and increases profit potential.
Thermo Scientific DCT6088
Dedicated Transit Time Flowmeter

Flexible & Easy-to-Use Programmable Relays for Remote Output


Combining digital signal processing (DSP) Up to four programmable relays can be
with correlation detection methods, the specified. The relays may be used as a contact
Thermo Scientific DCT6088 features output to a remote device such as an alarm,
exceptional performance and flexibility. totalizer, sampler or chlorinator. A powerful
It tolerates higher concentrations of gas 30,000 point data logger programmable
bubbles or entrained solids compared to in intervals of one second or more is also
traditional transit time flowmeters which are incorporated in the flowmeter.
principally designed for extremely clean liquid
Modular & Simple to Service
applications only. The non-intrusive, clamp-
The plug-in, modular construction of the
on transducers can be installed without flow
instrument simplifies field service and,
interruption and ensure leak-free measurements
in the unlikely event of failure, permits
with zero pressure drop. The simple, menu-
The Thermo Scientific the boards to be replaced in seconds.
driven operation of the DCT6088 allows the
UltraScan program offers The DCT6088 features many parts which
meter to be commissioned in a fraction of
a simple method to configure are common to other Thermo Scientific
the flowmeter and access the time necessary for competitive transit
flowmeters, dramatically reducing spare
to the extensive waveform time flowmeters.
parts inventory at sites where multiple
diagnostics.
Engineered for Maximum Uptime meters are in service.
Housed in a rugged Nema 4X (IP65) enclosure
Features Sample Applications
and qualified for -40°C (-40°F) operation, the
• Accuracy to ±0.5% of velocity full scale • HVAC
DCT6088 is well-suited to most industrial
• 0.01 ft/sec flow sensitivity • Potable water
environments. The high resolution, backlit
• Up to 4 programmable relays • Ultrapure liquid
LCD provides excellent visibility even
• Easy to install, clamp-on design • Deionized water
in poorly lit conditions. Outputs include
• Bi-directional flow measurement • Petroleum products
a 12-bit digital, optically-isolated, 4-20 mA
• Powerful 30,000 point data logger • Water and waste management
analog signal and RS232 serial interface.
Specifications and Ordering Information

Thermo Scientific DCT6088

Performance Specifications
Velocity Range ±0 m/s to 15 m/s (±0 m/s to 50 ft/s)
Accuracy ±0.5% of velocity or ±0.05 ft/sec typical
Fluids Potable water, ultrapure liquids, deionized water, petroleum products
Pipe Size 25 mm to 5 m (1 in to 200 in)
Physical Specifications
Transmitter NEMA 4X (IP65), flame retardant, fiberglass reinforced polyester
Transducers Two encapsulated transducers suitable for submersion or underground service; 9 m (30 ft) standard cable length
Weight Approximately 5.4 kg (12 lbs)
Functional Specifications
Outputs 4-20 mA (into 1k - 5k ohms), 12-bit, 5 kV, opto-isolated, loop or self-powered;
RS232 serial interface
Power Supply 90-132 Vac or 190-250 Vac, 50/60 Hz (switch selectable); 11-28 Vdc
Temperature Range Transducers: (surface) -40°C to +100°C (-40°F to +212°F); (ambient) -28°C to +80°C (-20°F to +176°F)
Transmitters: -40°C to +60°C (-40°F to +140°F)
Contact factory for higher temperature range requirements
Keypad 19-key with tactile action
Display 2-line, 40-character, alphanumeric, backlit LCD indicating present and total flow, velocity and signal strength
Data Logger 30,000 point data logger; programmable in 1 second intervals

DCT6088 Dimensional Diagram Ordering Information

MODEL NUMBER
285 mm
DCT6088: Dedicated Digital Correlation Transit Time Flowmeter
(11.20 in)

A. POWER SUPPLY
1: 90 to 132 Vac, 50/60 Hz 3: 12 to 24 Vdc nominal
2: 190 to 250 Vac, 50/60 Hz
(13.19 in)

B. OUTPUT
335 mm

167 mm
(6.60 in)

AC POWER/ 4-20mA DOWNSTREAM UPSTREAM


RELAY OUTPUT TRANSDUCER TRANSDUCER

0: 4-20 mA DC, no relay 3: Three relays


1: One relay 4: Four relays
2: Two relays

C. TRANSMITTER ENCLOSURE
1: NEMA 4X 2: NEMA 7

D. TRANSDUCER TYPE
S: Standard cable (100∞C/212∞F max)
DCT6088 Mounting Methods H: High temp cable (200∞C/392∞F max)

E. CABLE LENGTH
Z Method: directly across the pipe 030: 9 m (30 ft) cable
~ 203 mm (8 in) and larger XXX: XXX = length in feet

F. TRANSDUCER
TRANSMITTER ENCLOSURE

V Method: single reflex HAZARDOUS AREA


~ 101 mm (4 in) and larger CERTIFICATION
TRANSDUCER TYPE

A: None
MODEL NUMBER

POWER SUPPLY

CABLE LENGTH

CERTIFICATION

B: CSA: Class I, Div. 2


W Method: double reflex Groups A, B, C, D
~ 50 mm (2 in) and larger or Class II, Div. 2
OUTPUT

Groups E, F, G
C: CSA: Class I, Div. 1
WW Method: multi reflex Groups C, D or Class II,
~ 25 mm (1 in) DCT A B C D E F Div. 1 Groups E, F, G
6088
©2008 Thermo Fisher Scientific Inc. All rights reserved. Results may vary under different operating conditions. Specifications, terms and pricing are subject to change.
Not all products are available in all countries. Please consult your local sales representatives for details. Literature Code PI.2018.0108
Room 1010 - 1019 +86 (10) 5850-3588
Ping’an Mansion No. 23 Jinrong Street +86 (10) 6621-0847 fax
Xicheng Dist, Beijing 100032 CHINA
A-101, ICC Trade Tower, Senapati Bapat Road +91 (20) 6626 7000
Pune 411016 Maharashtra, INDIA +91 (20) 6626 7001 fax
Ion Path, Road Three, Winsford +44 (0) 1606 548700
Cheshire CW7 3GA UNITED KINGDOM +44 (0) 1606 548711 fax
Process Instruments 1410 Gillingham Lane +1 (800) 437-7979 www.thermo.com
Sugar Land, TX 77478 USA +1 (713) 272-0404
+1 (713) 272-4573 fax

You might also like