Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

CECO Sethco Model P90

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Sethco

P90 DRUM PUMP


For Safe And Fast
Transfer Of Chemicals

• Corrosive Liquids In
Hazardous Or
Non Hazardous
Environments
• Solvents

• SEALLESS
• EMPTIES 55 GALLON DRUMS IN LESS
THAN 2 MINUTES
• SELF PRIMING
• HIGH POWER DOUBLE INSULATED
1150 WATT MOTOR
• EASY MAINTENANCE, FIELD
REPAIRABLE
• ONE PIECE TUBE INSURES SAFE,
LEAKPROOF OPERATION
• CHOICE OF POLYPROPYLENE, KYNAR®,
OR STAINLESS STEEL PUMPS

700 Emlen Way, Telford, PA 18969 • P: 800.645.0500 • https://www.cecoenviro.com/sethco


SETHCO MODEL P-90 DRUM PUMPS

THE RIGHT CHOICE FOR TRANSFERRING CORROSIVE LIQUIDS FROM


CARBOYS, DRUMS, VATS, TANKS OR ANY OTHER CONTAINER

Pump Tube Features: Motor Features:


• Polypropylene, Kynar or stainless steel • High power, double
pump construction insulated 1150 watt motor
Choose from 3 materials of construction to Protected in a corrosion
transfer most corrosive liquids. resistant,high-strength, impact
resistant case.
• Sealless construction
Eliminates the major cause of pump • Large handle grip
failure. Ensures grasp when wearing
bulky safety rubber gloves.
• 1.66” (42mm) tube diameter
Designed to fit any bung to empty any • Impact resistant housing
drum or carboy around the world. Holds up to rough handling.

• More effective vapor seal • 15 foot cord


Motor is equipped with a heavy
• High quality design duty oil and acid resistant
One piece tube construction, fewer pump electrical cord and molded plug.
parts and bearing cup ensure reliability
and extends pump life. • On/Off switch with safety reset
circuit breaker
• Self priming Unlike hazardous automatic
A flip of the switch and pumping action restart units, the motor will
begins immediately. not restart until on/off switch
resets the circuit breaker.
• Quick draining
Pump drains quickly when • Continuous duty rated
removed from liquid. The powerful electric motor
will pump liquids continuously
• Wide vane axial impeller drum after drum without
Efficiently moves high viscosity and overloading the motor, even
specific gravity liquids up to 4000 ssu. when pumping high specific
gravity solutions.
• High flow
Empties a 55 gallon drum in less than 2 • Hazardous duty air motors
minutes. Empties a 500 gallon tank in less available
than 13 minutes. For safe transfer of hazardous,
flammable or combustible
• Easy to maintain liquids.
Bearing cup design allows fast,
inexpensive, easy to do repairs. No special • Lightweight
tools needed. Weighs only 9 pounds.
SELECT FROM HIGH POWER
INTERCHANGEABLE MOTORS

High-Power Double Insulated Hazardous Duty Air Motor


1150 Watt Motor Can be used in place of electric motor when desired.
Lightweight, impact resistant and easy to handle, this Completely interchangeable on any P90 pump.
motor is the most widely used. Select this motor when Recommended for use in areas where flammable vapors
transferring liquids that are non-hazardous. Can be used or other hazardous duty conditions exist.
with any P90 pump tube.

THREE INTERCHANGEABLE 30”, 40” 50” and 60” Standard Pump Tube Lengths
PUMP TUBE ASSEMBLIES
POLYPROPYLENE
Economical and Dependable
Wetted Parts
Polypropylene, Hastelloy C®, Tefzel®,
Viton®, Kynar®.
Typical Applications
Hydrochloric acid, sulfuric acid, nitric
acid, most electroplating solutions mild
alkaline solutions, chromic acid and other
non flammable solutions.
Temperature Limits
32° to 130°F (0° to 55°C)

STAINLESS STEEL
Heavy Duty design for
extended life
Wetted Parts
Stainless Steel, Teflon®, Kynar®.
Typical Applications
Alkalies, aqueous caustic, light oils, and
solvents.
ACCESSORIES
Temperature Limits
0° to 250°F (-18° to 121°C)

KYNAR®
Superior corrosion resistance,
withstands higher temperature.
Wetted Parts Bottom Inlet Strainer Bung Adapter Bonding Wire
Fits over pump tube Holds pump tube securely Required when pumping
Kynar®, Hastelloy C, Tefzel®, Viton®. flammables to bond and
to prevent debris from in the bung opening
ground equipment.
Typical Applications entering pump. Stainless (optional).
Strong mineral and oxidizing acids, alkalies, steel pump tube has built
metal etchants, chlorine, aqueous caustic, in strainer. (Supplied with
organic and nonflammable solvents. each complete P90 pump
and motor).
Temperature Limits
0° to 250° F (-18° to 121°C)
HIGH VOLUME PUMPING TO 35 GPM (132 LPM)

PUMP AND MOTOR SPECIFICATIONS


PUMP TUBES
Tube Maximum Shipping
Maximum
Tube Diameter Flow Maximum Specific Maximum Net Weight
Length Wetted (at widest point) Discharge (water at Head Gravity Viscosity** Weight w/o Hose
MODEL (in / cm) Materials (in / cm) (in / cm) 70°F / 21°C) Gravity** (reduced flow and pressure) (lbs. / kg) (lbs. / kg)

POLYPROPYLENE PUMP TUBE


P90H-30 30 / 76 Polypropylene, 1.75 / .80 5 / 2.3
P90H-40 40 / 101 Tefzel®†, for 1” I.D. 4000 SSU 2.75 / 2 5.5 / 2.5
35 GPM / 39 ft. /
Hastelloy C®, 1-2/3” / 4.2 cm 1.86
P90H-50 50 / 127 Hose 132 LPM 1189 cm (850 cks) 2.75 / 1.25 6 / 2.7
Viton®
P90H-60 60 / 152 Kynar® 3.25 / 1.5 6.5 / 2.9

PVDF PUMP TUBE


P90H-30K 30 / 76 PVDF 2.75 / 1.25 5 / 2.3
Tefzel®†,
P90H-40K 40 / 101 for 1” I.D. 35 GPM / 39 ft. / 4000 SSU 3.25 / 1.5 6.5 / 2.9
Hastelloy C®, 1-2/3” / 4.2 cm 1.86
P90H-50K 50 / 127 Hose 132 LPM 11.5 m (850 cks) 3.75 / 1.7 6 / 2.7
Viton®
P90H-60K 60 / 152 Kynar® 4.25 / 1.9 7.5 / 3.4

STAINLESS STEEL PUMP TUBE


SS-316,
Both 3/4”
Carp. 20, 4000 SSU
(1.9 cm) FNPT 35 GPM / 40 ft. /
P90S-40S 40 / 101 PVDF 1-3/4” / 4.4 cm 1.86 (850 cks) 8 / 3.6 11.5 / 5.2
® & 1-1/4” ID 132 LPM 11.5 m
Teflon
Kynar® Hose

† Available with Nylon in place of Teflon for nuclear service.

MOTORS

Net Weight Shipping Weight


Motor Description (lbs. / kg.) lbs. / kg.)

Air Drive-100 PSI @ 18 CFM


A With inlet air valve for motor speed and flow control, and 2 lbs. / .9 kg. 5 lbs. / 2.2 kg.
muffler for quiet operation

Electric - 115V, 50/60Hz, 1 ph, ODP, double-insulated with


15 feet of line cord, plug and on/off switch with built-in safety
B 7 lbs. / 3.2 kg. 9 lbs. / 4 kg.
manual reset circuit breaker. Motor cannot accidentally restart after
breaker trips. Switch must be manually turned back on to reset breaker.

Electric - 230V, 50/60Hz, 1 ph. ODP, as per “B” above.


C 7 lbs. / 3.2 kg. 9 lbs. / 4 kg.
Plug is not provided.

You might also like