Keystone Aktuator
Keystone Aktuator
Keystone Aktuator
The EPI-2 series are compact, intelligent quarter-turn electric actuators for the accurate control of valves
with torques from 35 to 2000 Nm / 308 to 17,700 lb.in.
Features
37 O-ring Di=52.07/W=2.62 1*
9 49
38 O-ring Di=6.07/W=1.78 1*
14 25 37
39 Plug 1
40 Position label 1
41 Power clamps protection 1 1 24
39 15 18 35 12 23 36 33
42 Ring 2
43 Ring for pins alignement 1
44 Ring RW 7 UNI7433 2
45 Seal washer 8.3 2
46 Sliding ring 1
47 Snap ring for shaft D.6 1
48 Terminal block cover 1
49 Terminal board gasket 1*
50 Wheel 1
2
Keystone EPI-2 electric actuators
Component parts - Model 2000/E171
3
Keystone EPI-2 electric actuators
Design features
4
Keystone EPI-2 electric actuators
Optional modules and performance
Optional modules
Notes
1. Each optional module (OMx) will be provided with its own installation and maintenance instructions.
2. All modules except OM13 are available for both single phase and 3-phase voltage versions.
3. Bluetooth component is integrated in the OM1, OM9 and OM11 card: not available for integration by local
organizations, as a stand alone unit.
4. OM13 is not available with 3-phase supply and for LV version (single phase voltage from 24 to 48 V DC/V AC).
5
Keystone EPI-2 electric actuators
Performance and approvals
Operating times
Nominal torque Operating time (secs 90°) at selected step
Model (Nm / lb.in.) 8 6 4
063/E006 63/600 15 28 48
125/E013 125/1300 15 28 48
250/E025 250/2500 15 28 48
500/E051 500/5100 15 28 48
1000/E091 1000/9100 24 45 80
2000/E171 2000/17700 53 100 180
Approvals
Waterproof IP66/68 or NEMA 4/4X/6 (NEMA ICS6/NEMA 250)
CAN/CSA C22.2 No 139-10 and UL 429-2009
Explosionproof Ex d e IIB T5 Gb (gas)
Ex tb IIIC T100°C Db (dust)
(prefix c for model 2000)
NEC 500 (FM approval)
Class I, Zone 1 Group IIB
Class II, III, Division 1, Groups E, F,G
Painting ESPC for 1000 hrs salt spray resistance (ASTM D 2247-02 and ASTM B117-97)
Vibration and noise 1 to 500 Hz with 2 g peak acceleration
(IEC60068-2-6-appendix B)
65 dB (grade A) (EN 21680)
6
Keystone EPI-2 electric actuators
Overall dimensions - Models 063/E006-125/E013-250/E025-500/E051-1000/E091
B
b3 b2 b1
X
W
H
øv
h3
h2
W
h1
W
e e F c
Ø
d
A
c
a1
Notes
W = Nr. 4 cable entries M25x1.5 acc. to ISO 724/965-1 (others available as special versions)
X = Space for cover removal
F = ISO 5211 Standard flange (others available)
7
Keystone EPI-2 electric actuators
Overall dimensions - Model 2000/E171
B
b3 b2 b1
X
W
W
øv
H
h2
h3
h1
W
e e
c
F
*
d
A
A1
c
a1
a11
Notes
W = Nr. 4 cable entries M25x1.5 acc. to ISO 724/965-1 (others available as special versions)
X = Space for cover removal
F = ISO 5211 Standard flange (others available)
8
Keystone EPI-2 electric actuators
Overall dimensions - optional modules
X/X1
H/H1
A/A1
a1/a11
Notes
1. Dimensions a1 and A are for the standard unit.
2. Dimensions a11 and A1 are for the standard unit plus a local interface option.
3. Dimensions H and X are for the standard unit.
4. Dimensions H1 and X1 are for the standard unit plus a Beacon type indicator.
5. X / X1 indicates the space for cover removal.
6. All other dimensions are as the standard unit.
9
Keystone EPI-2 electric actuators
Output drive dimensions
ℓ
ødx ødx
ød7
ax
ød7
m
SQ
Notes
1. Insert bush supplied with unmachined bore.
Largest bore can be supplied with solid piece bush.
2. Fixing bolts or rods supplied only on request.
3. dx: the maximum accepted diameter described by key, square or flat machining.
4. Position of the shaft with the valve closed.
10
Keystone EPI-2 electric actuators
Wiring diagram - base version
Blinker
local
Monitor selector
relay relay CLC1 CLC2 OPC1 OPC2
L1 L2 L3 35 36 32 33 34 1 2 3 4 20 21 22 23 24 25 26 27 28 29 30 31
Ground
Notes
1. Power connection L1-L2 for V DC or V AC single phase motor supply from 24 V to 48 V or from 100 V to 240 V.
Power connection L1-L2-L3 for 3 phase motor supply from 208 V to 575 V (check the actuator label for the correct voltage to be applied).
OP OP
34 35 35
OP
35 CL CL
36 36
CL
36 32 32
32
Internal supply 24 V DC External supply 24 / 120 V AC External supply 24 / 120 V DC
33
11
Keystone EPI-2 electric actuators
Current absorption - single phase and DC voltage
Notes
1. A = absorbed current (Amp) at nominal conditions (output torque 100%)
2. Max current (Amp) at stall conditions = 1.2 x A
3. Power factor for V AC supply = 0.60
4. Peak current: max 8xIn
5. Peak current duration: less than 0.1 secs
12
Keystone EPI-2 electric actuators
Current absorption - three phase voltage
Notes
1. A = absorbed current (Amp) at nominal conditions (output torque 100%)
2. Max current (Amp) at stall conditions = 1.2 x A
3. Power factor for V AC supply = 0.60
4. Peak current: max 8xIn
5. Peak current duration: less than 0.1 secs
13
Keystone EPI-2 electric actuators
Ordering information
Selection guide
Example KPD 063 LV PD P1 2 D4
Product
KPD ISO 5211 with double star insert
KPE ISO 5211 with flat or key insert
KPU Non-ISO flange
KPB ISO 5211 flange - insert not machined
KPK Key non-ISO flange - insert not machined
KEU (NPT) US version ISO 5211 flange
with ISO insert, 4x 1"NPT entries
Models
063 Model 063/E006 06B Model 063/E006 with Beacon
125 Model 125/E013 12B Model 125/E013 with Beacon
250 Model 250/E025 25B Model 250/E025 with Beacon
500 Model 500/E051 50B Model 500/E051 with Beacon
1K0 Model 1000/E091 1KB Model 1000/E091 with Beacon
2K0 Model 2000/E171 2KB Model 2000/E171 with Beacon
Voltage
LV 1-phase 24-48 V AC/DC 3A 3-phases 208-240 V AC
HV 1-phase 100-240 V AC/DC 3B 3-phases 380-480 V AC
3C 3-phases 500-575 V AC
Speed/Duty
PD Standard speed range and standard duties for model 063/E006 to 500/E051
PE Standard speed range and standard duties for model 1000/E091
PF Standard speed range and standard duties for model 2000/E171
Option modules
00 No optional modules P7 OM1/Bluetooth 5D OM11/Bluetooth
P1 OM1 P3 OM3 6D OM11/OM3/Bluetooth
PA OM1/OM3/Bluetooth 5P OM9/Bluetooth PG OM13
P6 OM1/OM3 6P OM9/OM3/Bluetooth
Approvals/Protections
0 Standard protection NEMA 4/4X/6 (IP66/68M) - CSA certificate T°amb from -40°C to +60°C / -40°F to +140°F
2 Standard protection NEMA 4/4X/6 (IP66/68M) T°amb from -25°C to +70°C / -13°F to +158°F
3 Standard protection NEMA 4/4X/6 (IP66/68M) T°amb from -40°C to +70°C / -40°F to +158°F
4 Explosionproof IP66/68 (NEMA 4/4X/6) + Ex d e IIB T5 Gb - EX tb IIC T100°C Db T°amb from -20°C to +65°C / -4°F to +149°F
(prefix c for model 2000)
9 Explosionproof IP66/68 (NEMA 4/4X/6) + Ex d e IIB T5 Gb - EX tb IIIC T100°C Db T°amb from -40°C to +65°C / -40°F to +149°F
(prefix c for model 2000)
6 Explosionproof NEC 500 (FM approval) Class I, Zone 1 Group IIB , Class II, III, Division 1, Groups E, F,G
Flange/Insert
00 No flange insert
B4 Model 063/E006 flange ISO 5211/F05/F07 - insert not machined (KPB)
B5 Model 125/E013 flange ISO 5211/F07/F10 - insert not machined (KPB)
B5 Model 250/E025 flange ISO 5211/F07/F10/F12 - insert not machined (KPB)
B6 Model 500/E051 flange ISO 5211/F10/F12 - insert not machined (KPB)
B7 Models 1000/E091-2000/E171 flange ISO 5211/F10/F14 - insert not machined (KPB)
BA Models 1000/E091-2000/E171 flange ISO 5211/F12/F16 - insert not machined (KPB)
D4 Model 063/E006 ISO 5211 (KPD)
D5 Models 125/E013-250/E025 ISO 5211 (KPD)
D6 Model 500/E051 ISO 5211 (KPD)
D7 Models 1000/E091-2000/E171 F10 to F14 ISO 5211 (KPD)
DA Models 1000/E091-2000/E171 F12 to F16 ISO 5211 (KPD)
E3 Model 063/E006 ISO 5211 (KPE)
E5 Models 125/E013-250/E025 ISO 5211 (KPE)
E6 Model 500/E051 ISO 5211 (KPE)
E9 Models 1000/E091-2000/E171 F12 to 16 ISO 5211 (KPE)
K4 Model 063/E006 flange key 44.45-82.6 - insert not machined (KPK)
K8 Model 125/E025 flange key 82.6 - insert not machined (KPK)
K8 Model 250/E025 flange key 82.6-127 - insert not machined (KPK)
KA Model 500/E051 flange key 82.6-127 - insert not machined (KPK)
KC Models 1000/E091-2000/E171 flange key 127-165 - insert not machined (KPK)
U4 Model 063/E006 non-ISO (KPU)
U8 Models 125/E013-250/E025 non-ISO (KPU)
UA Model 500/E051 non-ISO (KPU)
UC Models 1000/E091-2000/E171 non-ISO (KPU)
14
Keystone EPI-2 electric actuators
Ordering information
15
© 2017 Emerson. All rights reserved. 16