Ds kt671ml
Ds kt671ml
Ds kt671ml
User Manual
DS-K1T671 Series Face Recognition Terminal User Manual
Legal Information
LEGAL DISCLAIMER
● TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS DOCUMENT AND THE
PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED "AS
IS" AND "WITH ALL FAULTS AND ERRORS". HIKVISION MAKES NO WARRANTIES, EXPRESS OR
i
DS-K1T671 Series Face Recognition Terminal User Manual
Data Protection
● To protect data, the development of Hikvision Products incorporates privacy by design
principles. For example, for Products with facial recognition features, biometrics data is stored in
your Products with encryption method; for fingerprint Products, only fingerprint template will be
saved, which is impossible to reconstruct a fingerprint image.
● As a data controller/processor, you may process personal data, including collection, storage, use,
processing, disclosure, deletion, etc. You are advised to pay attention to and comply with
applicable laws and regulations related to the protection of personal data, including without
limitation, conducting security controls to safeguard personal data, such as, implementing
reasonable administrative and physical security controls, conduct periodic reviews and the
assessments of the effectiveness of your security controls.
ii
DS-K1T671 Series Face Recognition Terminal User Manual
Symbol Conventions
The symbols that may be found in this document are defined as follows.
Symbol Description
Indicates a hazardous situation which, if not avoided, will or could
Danger result in death or serious injury.
iii
DS-K1T671 Series Face Recognition Terminal User Manual
Regulatory Information
FCC Information
Please take attention that changes or modification not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
FCC compliance: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help
This equipment should be installed and operated with a minimum distance 20cm between the
radiator and your body.
FCC Conditions
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause
undesired operation.
EU Conformity Statement
This product and - if applicable - the supplied accessories too are marked with "CE"
and comply therefore with the applicable harmonized European standards listed
iv
DS-K1T671 Series Face Recognition Terminal User Manual
v
DS-K1T671 Series Face Recognition Terminal User Manual
Safety Instruction
These instructions are intended to ensure that user can use the product correctly to avoid danger
or property loss.
The precaution measure is divided into Dangers and Cautions:
Dangers: Neglecting any of the warnings may cause serious injury or death.
Cautions: Neglecting any of the cautions may cause injury or equipment damage.
Dangers: Follow these safeguards to prevent Cautions: Follow these precautions to prevent
serious injury or death. potential injury or material damage.
Danger:
● All the electronic operation should be strictly compliance with the electrical safety regulations,
fire prevention regulations and other related regulations in your local region.
● Please use the power adapter, which is provided by normal company. This equipment is
intended to be supplied from the Class 2 surge protected power source rated 12 VDC, 2 A.
● Do not connect several devices to one power adapter as adapter overload may cause over-heat
or fire hazard.
● Please make sure that the power has been disconnected before you wire, install or dismantle the
device.
● When the product is installed on wall or ceiling, the device shall be firmly fixed.
● If smoke, odors or noise rise from the device, turn off the power at once and unplug the power
cable, and then please contact the service center.
● Do not ingest battery, Chemical Burn Hazard.
This product contains a coin/button cell battery. If the coin/button cell battery is swallowed, it
can cause severe internal burns in just 2 hours and can lead to death.
Keep new and used batteries away from children. If the battery compartment does not close
securely, stop using the product and keep it away from children. If you think batteries might have
been swallowed or placed inside any part of the body, seek immediate medical attention.
● If the product does not work properly, please contact your dealer or the nearest service center.
Never attempt to disassemble the device yourself. (We shall not assume any responsibility for
problems caused by unauthorized repair or maintenance.)
vi
DS-K1T671 Series Face Recognition Terminal User Manual
Cautions:
● Do not drop the device or subject it to physical shock, and do not expose it to high
electromagnetism radiation. Avoid the equipment installation on vibrations surface or places
subject to shock (ignorance can cause equipment damage).
● Do not place the device in extremely hot (refer to the specification of the device for the detailed
operating temperature), cold, dusty or damp locations, and do not expose it to high
electromagnetic radiation.
● The device cover for indoor use shall be kept from rain and moisture.
● Exposing the equipment to direct sun light, low ventilation or heat source such as heater or
radiator is forbidden (ignorance can cause fire danger).
● Do not aim the device at the sun or extra bright places. A blooming or smear may occur
otherwise (which is not a malfunction however), and affecting the endurance of sensor at the
same time.
● Please use the provided glove when open up the device cover, avoid direct contact with the
device cover, because the acidic sweat of the fingers may erode the surface coating of the device
cover.
● Please use a soft and dry cloth when clean inside and outside surfaces of the device cover, do
not use alkaline detergents.
● Please keep all wrappers after unpack them for future use. In case of any failure occurred, you
need to return the device to the factory with the original wrapper. Transportation without the
original wrapper may result in damage on the device and lead to additional costs.
● Improper use or replacement of the battery may result in hazard of explosion. Replace with the
same or equivalent type only. Dispose of used batteries according to the instructions provided by
the battery manufacturer.
● Biometric recognition products are not completely applicable to anti-spoofing environments. If
you require a higher security level, use multiple authentication modes.
● Working temperature: 0 °C to 50 °C; Working humidity: 10% to 90% (no condensing)
● Indoor use. The device should be at least 2 meters away from the light, and at least 3 meters
away from the window.
● Version: 1.0, Issue Date: 20200519
● Outdoor use or use in environment exceeding the device temperature measurement will affect
the temperature measurement accuracy.
vii
DS-K1T671 Series Face Recognition Terminal User Manual
Available Models
viii
DS-K1T671 Series Face Recognition Terminal User Manual
Contents
Chapter 1 Overview .................................................................................................................... 1
1.1 Overview ................................................................................................................................ 1
1.2 Features ................................................................................................................................. 1
Chapter 2 Appearance ................................................................................................................ 3
Chapter 3 Installation ................................................................................................................. 5
3.1 Installation Environment ........................................................................................................ 5
3.2 Install with Gang Box ............................................................................................................. 5
3.3 Install without Gang Box ...................................................................................................... 11
Chapter 4 Wiring ...................................................................................................................... 17
4.1 Terminal Description ............................................................................................................ 17
4.2 Wire Normal Device ............................................................................................................. 20
4.3 Wire Secure Door Control Unit ............................................................................................ 21
Chapter 5 Activation ................................................................................................................. 22
5.1 Activate via Device ............................................................................................................... 22
5.2 Activate via Web Browser .................................................................................................... 24
5.3 Activate via SADP ................................................................................................................. 24
5.4 Activate Device via Client Software ...................................................................................... 26
Chapter 6 Quick Operation ....................................................................................................... 27
6.1 Select Language ................................................................................................................... 27
6.2 Set Password Change Type ................................................................................................... 29
6.3 Set Network Parameters ...................................................................................................... 31
6.4 Access to Platform ............................................................................................................... 33
6.5 Privacy Settings .................................................................................................................... 35
6.6 Set Administrator ................................................................................................................. 36
Chapter 7 Basic Operation ........................................................................................................ 39
7.1 Login .................................................................................................................................... 39
ix
DS-K1T671 Series Face Recognition Terminal User Manual
x
DS-K1T671 Series Face Recognition Terminal User Manual
xi
DS-K1T671 Series Face Recognition Terminal User Manual
xii
DS-K1T671 Series Face Recognition Terminal User Manual
Chapter 1 Overview
1.1 Overview
Face recognition terminal is a kind of access control device for face recognition, which is mainly
applied in security access control systems, such as logistic centers, airports, university campuses,
alarm centrals, dwellings, etc.
1.2 Features
Note
Parts of the models support fingerprint module, refer to the actual products.
● Multiple authentication modes
● Face recognition duration < 0.2 s/User; face recognition accuracy rate ≥ 99%
● Transmits card and user data from or to the client software via TCP/IP protocol and saves the
data on the client software
● Imports pictures from the USB flash drive to the device or export pictures, events, from the
device to the USB flash drive
● Device management, log search, and parameter settings via the device
● Stand-alone operation
● Capture linkage and captured pictures saving
● Connects to one external card reader or access controller via RS-485 protocol
● Connects to external access controller or Wiegand card reader via Wiegand protocol
● Connects to secure door control unit via RS-485 protocol to avoid the door opening when the
terminal is destroyed
● Remote live view via RTSP protocol; encoding mode: H.264
● NTP, manually time synchronization, and auto synchronization
● Voice prompt
● Watchdog design and tamper function
1
DS-K1T671 Series Face Recognition Terminal User Manual
Note
Parts of the models support fingerprint module, refer to the actual products.
● Multiple authentication modes
● Face recognition duration < 0.2 s/User; face recognition accuracy rate ≥ 99%
● Transmits card and user data from or to the client software via TCP/IP protocol and saves the
data on the client software
● Imports pictures from the USB flash drive to the device or export pictures, events, from the
device to the USB flash drive
● Device management, log search, and parameter settings via the device
● Stand-alone operation
● Capture linkage and captured pictures saving
● Connects to one external card reader or access controller via RS-485 protocol
● Connects to secure door control unit via RS-485 protocol to avoid the door opening when the
terminal is destroyed
● Connects to external access controller or Wiegand card reader via Wiegand protocol
● Remote live view via RTSP protocol; encoding mode: H.264
● NTP, manually time synchronization, and auto synchronization
● Voice prompt
● Watchdog design and tamper function
● Support English, Spanish (South America), Arabic, Thai, Indonesian, Russian, Vietnamese,
Portuguese (Brazil)
2
DS-K1T671 Series Face Recognition Terminal User Manual
Chapter 2 Appearance
Refer to the following contents for detailed information of the face recognition terminal:
Note
Parts of models support fingerprint recognition
function.
3
DS-K1T671 Series Face Recognition Terminal User Manual
4
DS-K1T671 Series Face Recognition Terminal User Manual
Chapter 3 Installation
5
DS-K1T671 Series Face Recognition Terminal User Manual
6
DS-K1T671 Series Face Recognition Terminal User Manual
7
DS-K1T671 Series Face Recognition Terminal User Manual
8
DS-K1T671 Series Face Recognition Terminal User Manual
9
DS-K1T671 Series Face Recognition Terminal User Manual
Note
● The installation height here is the recommended height. You can change it according to your
actual needs.
● For easy installation, drill holes on mounting surface according to the supplied mounting
template.
12. After installation, for the proper use of the device (outdoor use), stick the protection film (parts
of models supplied) on the screen.
10
DS-K1T671 Series Face Recognition Terminal User Manual
11
DS-K1T671 Series Face Recognition Terminal User Manual
12
DS-K1T671 Series Face Recognition Terminal User Manual
7. Install the sheet back to the device with the two screws.
8. Apply Silicone sealant among the cable wiring area to keep the raindrop from entering.
13
DS-K1T671 Series Face Recognition Terminal User Manual
14
DS-K1T671 Series Face Recognition Terminal User Manual
15
DS-K1T671 Series Face Recognition Terminal User Manual
Note
● The installation height here is the recommended height. You can change it according to your
actual needs.
● For easy installation, drill holes on mounting surface according to the supplied mounting
template.
12. After installation, for the proper use of the device (outdoor use), stick the protection film (parts
of models supplied) on the screen.
16
DS-K1T671 Series Face Recognition Terminal User Manual
Chapter 4 Wiring
You can connect the RS-485 terminal with the RS-485 card reader, connect the NC and COM
terminal with the door lock, connect the SENSOR terminal with the door contact, the BTN/GND
terminal with the exit button, connect the alarm output and input terminal with the alarm output/
input devices, and connect the Wiegand terminal with the Wiegand card reader or the access
controller.
If connect the WIEGAND terminal with the access controller, the face recognition terminal can
transmit the authentication information to the access controller and the access controller can
judge whether to open the door or not.
Note
● If cable size is 18 AWG, you should use a 12 V power supply. And the distance between the
power supply and the device should be no more than 20 m.
● If the cable size is 15 AWG, you should use a 12 V power supply. And the distance between the
power supply and the device should be no more than 30 m.
● If the cable size is 12 AWG, you should use a 12 V power supply. And the distance between the
power supply and the device should be no more than 40 m.
17
DS-K1T671 Series Face Recognition Terminal User Manual
18
DS-K1T671 Series Face Recognition Terminal User Manual
19
DS-K1T671 Series Face Recognition Terminal User Manual
Note
● You should set the face recognition terminal's Wiegand direction to "Input" to connect to a
Wiegand card reader. If connects to an access controller, you should set the Wiegand direction to
"Output" to transmit authentication information to the access controller.
● For details about Wiegand direction settings, see Setting Wiegand Parameters in Communication
Settings.
● The suggested external power supply for door lock is 12 V, 1 A. The suggested external power
supply for the Wiegand card reader is 12 V, 1A.
● The suggested power cable's diameter: 22 AWG. The suggested other cable's diameter: 26 AWG.
● Do not wire the device to the electric supply directly.
Warning
The face recognition terminal shall adapt an external listed Class 2 power supply with surge
protected function.
20
DS-K1T671 Series Face Recognition Terminal User Manual
Note
The secure door control unit should connect to an external power supply separately. The suggested
external power supply is 12V, 0.5A.
21
DS-K1T671 Series Face Recognition Terminal User Manual
Chapter 5 Activation
You should activate the device before the first login. After powering on the device, the system will
switch to Device Activation page.
Activation via the device, SADP tool and the client software are supported.
The default values of the device are as follows:
● The default IP address: 192.0.0.64
22
DS-K1T671 Series Face Recognition Terminal User Manual
Caution
The password strength of the device can be automatically checked. We highly recommend you
change the password of your own choosing (using a minimum of 8 characters, including at least
three kinds of following categories: upper case letters, lower case letters, numbers, and special
23
DS-K1T671 Series Face Recognition Terminal User Manual
characters) in order to increase the security of your product. And we recommend you change your
password regularly, especially in the high security system, changing the password monthly or
weekly can better protect your product.
Proper configuration of all passwords and other security settings is the responsibility of the
installer and/or end-user.
Note
Characters containing admin and nimda are not supported to be set as activation password.
After activation, you should select language, set password change type, set application mode, set
network, set platform parameters, set privacy parameters, and set administrator.
Note
Make sure the device IP address and the computer's should be in the same IP segment.
2. Create a new password (admin password) and confirm the password.
Caution
STRONG PASSWORD RECOMMENDED-We highly recommend you create a strong password of
your own choosing (using a minimum of 8 characters, including upper case letters, lower case
letters, numbers, and special characters) in order to increase the security of your product. And
we recommend you reset your password regularly, especially in the high security system,
resetting the password monthly or weekly can better protect your product.
Note
Characters containing admin and nimda are not supported to be set as activation password.
3. Click Activate.
4. Edit the device IP address. You can edit the IP address via the SADP tool, the device, and the
client software.
24
DS-K1T671 Series Face Recognition Terminal User Manual
The following steps show how to activate a device and modify its IP address. For batch activation
and IP addresses modification, refer to User Manual of SADP for details.
Steps
1. Run the SADP software and search the online devices.
2. Find and select your device in online device list.
3. Input new password (admin password) and confirm the password.
Caution
STRONG PASSWORD RECOMMENDED-We highly recommend you create a strong password of
your own choosing (using a minimum of 8 characters, including upper case letters, lower case
letters, numbers, and special characters) in order to increase the security of your product. And
we recommend you reset your password regularly, especially in the high security system,
resetting the password monthly or weekly can better protect your product.
Note
Characters containing admin and nimda are not supported to be set as activation password.
4. Click Activate to start activation.
25
DS-K1T671 Series Face Recognition Terminal User Manual
2) Change the device IP address to the same subnet as your computer by either modifying the IP
address manually or checking Enable DHCP.
3) Input the admin password and click Modify to activate your IP address modification.
Note
This function should be supported by the device.
1. Enter the Device Management page.
2. Click on the right of Device Management and select Device.
3. Click Online Device to show the online device area.
The searched online devices are displayed in the list.
4. Check the device status (shown on Security Level column) and select an inactive device.
5. Click Activate to open the Activation dialog.
6. Create a password in the password field, and confirm the password.
Caution
The password strength of the device can be automatically checked. We highly recommend you
change the password of your own choosing (using a minimum of 8 characters, including at least
three kinds of following categories: upper case letters, lower case letters, numbers, and special
characters) in order to increase the security of your product. And we recommend you change
your password regularly, especially in the high security system, changing the password monthly
or weekly can better protect your product.
Proper configuration of all passwords and other security settings is the responsibility of the
installer and/or end-user.
Note
Characters containing admin and nimda are not supported to be set as activation password.
7. Click OK to activate the device.
26
DS-K1T671 Series Face Recognition Terminal User Manual
27
DS-K1T671 Series Face Recognition Terminal User Manual
28
DS-K1T671 Series Face Recognition Terminal User Manual
29
DS-K1T671 Series Face Recognition Terminal User Manual
30
DS-K1T671 Series Face Recognition Terminal User Manual
Note
You can only select one type to change password. If you need, you can enter the web page to set
both of the changing types.
Note
Parts of the device models supports wi-fi function. Refers to the actual device for details.
1. When you enter the Select Network page, tap Wired Network or Wi-Fi for your actual needs.
31
DS-K1T671 Series Face Recognition Terminal User Manual
Note
Disconnect the wired network before connecting a Wi-Fi.
2. Tap Next.
Wired Network
Note
Make sure the device has connected to a network.
32
DS-K1T671 Series Face Recognition Terminal User Manual
If enable DHCP, the system will assign the IP address and other parameters automatically.
If disable DHCP, you should set the IP address, the subnet mask, and the gateway.
Note
IP address of 192.168.1.64, and 192.168.1.7 are not suggested to use.
Wi-Fi
Select a Wi-Fi and enter the Wi-Fi's password to get connected.
Or tap Add Wi-Fi and enter the Wi-Fi's name and the password to get connected.
3. Optional: Tap Skip to skip network settings.
Note
Parts of the device models supports function. Refers to the actual device for details.
1. Enable Access to Hik-Connect, and set the server IP and verification code.
33
DS-K1T671 Series Face Recognition Terminal User Manual
Note
If you tap Previous to return to the Wi-Fi configuration page, you need to tap the connected Wi-
Fi or connect another Wi-Fi to enter the platform page again.
34
DS-K1T671 Series Face Recognition Terminal User Manual
35
DS-K1T671 Series Face Recognition Terminal User Manual
Upload Captured Pic. When Auth. (Upload Captured Picture When Authenticating)
Upload the pictures captured when authenticating to the platform automatically.
Save Captured Pic. When Auth. (Save Captured Picture When Authenticating)
If you enable this function, you can save the picture when Authenticating to the device.
Save Registered Pic. (Save Registered Picture)
The registered face picture will be saved to the system if you enable the function.
Upload Pic. After Linked Capture (Upload Picture After Linked Capture)
Upload the pictures captured by linked camera to the platform automatically.
Save Pic. After Linked Capture (Save Pictures After Linked Capture)
If you enable this function, you can save the picture captured by linked camera to the device.
Tap Next to complete the settings.
36
DS-K1T671 Series Face Recognition Terminal User Manual
Note
Up to one credential should be added.
- : Face forward at the camera. Make sure the face is in the face recognition area. Click to
capture and click to confirm.
37
DS-K1T671 Series Face Recognition Terminal User Manual
- : Enter the card No. or present card on the card presenting area. Click OK.
4. Click OK.
You will enter the authentication page.
Status Icon Description
/
Device is armed/not armed.
/
Hik-Connect is enabled/disabled.
/ /
The device wired network is connected/not connected/connecting failed.
/ /
The device' Wi-Fi is enabled and connected/not connected/enabled but not connected.
Shortcut Keys Description
Note
You can configure those shortcut keys displayed on the screen. For details, see Basic Settings .
Note
The device should be added to the center, or the calling operation will be failed.
38
DS-K1T671 Series Face Recognition Terminal User Manual
7.1 Login
Login the device to set the device basic parameters.
39
DS-K1T671 Series Face Recognition Terminal User Manual
40
DS-K1T671 Series Face Recognition Terminal User Manual
Note
The device will be locked for 30 minutes after 5 failed attempts.
3. Optional: Tap and you can enter the device activation password for login.
4. Optional: Tap and you can exit the admin login page.
41
DS-K1T671 Series Face Recognition Terminal User Manual
Note
The device will be locked for 30 minutes after 5 failed password attempts.
42
DS-K1T671 Series Face Recognition Terminal User Manual
43
DS-K1T671 Series Face Recognition Terminal User Manual
Steps
1. Hold the initial page for 3 s and slide to the left/right by following the gesture and log in the
page.
2. Optional: If you have set an administrator, tap in the pop-up admin authentication page.
44
DS-K1T671 Series Face Recognition Terminal User Manual
Note
If you have only set 1 password change type, you will go to the corresponded password change
page for further settings.
5. Answer the security questions or change the password according to email address.
- Security Questions: Answer the security questions that configured when activation.
- Email Address
Note
Make sure the device has added to the Hik-Connect account.
a. Download Hik-Connect app.
b. Go to More → Reset Device Password .
c. Scan the QR code on the device and a verification code will be popped up.
Note
Tap the QR code to get a larger picture.
d. Enter the verification code on the device page.
6. Create a new password and confirm it.
7. Tap OK.
45
DS-K1T671 Series Face Recognition Terminal User Manual
Note
● The device's IP address and the computer IP address should be in the same IP segment.
4. Set the DNS parameters. You can enable Auto Obtain DNS, set the preferred DNS server and the
alternate DNS server.
46
DS-K1T671 Series Face Recognition Terminal User Manual
Steps
Note
The function should be supported by the device.
1. Tap Comm. (Communication Settings) on the Home page to enter the Communication Settings
page.
2. On the Communication Settings page, tap.
47
DS-K1T671 Series Face Recognition Terminal User Manual
Note
Only digits, letters, and special characters are allowed in the password.
5. Set the Wi-Fi's parameters.
- By default, DHCP is enable. The system will allocate the IP address, the subnet mask, and the
gateway automatically.
- If disable DHCP, you should enter the IP address, the subnet mask, and the gateway manually.
6. Tap OK to save the settings and go back to the Wi-Fi tab.
7. Tap to save the network parameters.
48
DS-K1T671 Series Face Recognition Terminal User Manual
Note
If you select Access Controller: If connect the device to a terminal via the RS-485 interface, set
the RS-485 address as 2. If you connect the device to a controller, set the RS-485 address
according to the door No.
4. Tap the back icon at the upper left corner and you should reboot the device if you change the
parameters.
49
DS-K1T671 Series Face Recognition Terminal User Manual
devices will transmit the card No. via Wiegand 26 or Wiegand 34.
● Input: A face recognition terminal can connect a Wiegand card reader.
Note
If you change the external device, and after you save the device parameters, the device will
reboot automatically.
50
DS-K1T671 Series Face Recognition Terminal User Manual
51
DS-K1T671 Series Face Recognition Terminal User Manual
Address Type
Select an address type according to your actual needs.
IP Address
Set the ISUP server's IP address.
Port No.
Set the ISUP server's port No.
Note
Port No. Range: 0 to 65535.
Device ID
Set device serial no.
ISUP Key
If you choose V5.0, you should create an account and ISUP key. If you choose other version,
you should create an ISUP account only.
Note
● Remember the ISUP account and ISUP key. You should enter the account name or the key
when the device should communicate with other platforms via ISUP protocol.
● ISUP key range: 8 to 32 characters.
Note
Parts of the device models supports function. Refers to the actual device for details.
1. Tap Comm. (Communication Settings) on the Home page to enter the Communication Settings
page.
2. On the Communication Settings page, tap Access to Hik-Connect.
3. Enable Access to Hik-Connect
4. Enter Server IP.
5. Create the Verification Code, and you need to enter the verification code when you manage the
devices via Hik-Connect.
52
DS-K1T671 Series Face Recognition Terminal User Manual
Note
● The employee ID should be less than 32 characters. And it can be a combination of lower
4. Tap the Name field and input the user name on the soft keyboard.
Note
● Numbers, upper case letters, lower case letters, and special characters are allowed in the user
name.
● Up to 32 characters are allowed in the user name.
Note
● For details about adding a face picture, see Add Face Picture .
Note
For details about setting the authentication type, see Set Authentication Mode .
7. Enable the Administrator Permission function.
Enable Administrator Permission
The user is the administrator. Except for the normal attendance function, the user can also
enter the Home page to operate after authenticating the permission.
8. Tap to save the settings.
53
DS-K1T671 Series Face Recognition Terminal User Manual
Note
● The employee ID should be less than 32 characters. And it can be a combination of lower
4. Tap the Name field and input the user name on the soft keyboard.
Note
● Numbers, upper case letters, lower case letters, and special characters are allowed in the user
name.
● The suggested user name should be within 32 characters.
5. Tap the Face Picture field to enter the face picture adding page.
54
DS-K1T671 Series Face Recognition Terminal User Manual
55
DS-K1T671 Series Face Recognition Terminal User Manual
Note
● Make sure your face picture is in the face picture outline when adding the face picture.
● Make sure the captured face picture is in good quality and is accurate.
● For details about the instructions of adding face pictures, see Tips When Collecting/
Comparing Face Picture .
After completely adding the face picture, a captured face picture will be displayed at the upper
right corner of the page.
7. Tap Save to save the face picture.
8. Optional: Tap Try Again and adjust your face position to add the face picture again.
9. Set the user role.
Administrator
The user is the administrator. Except for the normal attendance function, the user can also
enter the Home page to operate after authenticating the permission.
Normal User
The User is the normal user. The user can only authenticate or take attendance on the initial
page.
10. Tap to save the settings.
Note
● The employee ID should be less than 32 characters. And it can be a combination of lower
5. Tap the Name field and input the user name on the soft keyboard.
Note
● Numbers, upper case letters, lower case letters, and special characters are allowed in the user
name.
● The suggested user name should be within 32 characters.
56
DS-K1T671 Series Face Recognition Terminal User Manual
Note
● The card No. cannot be empty.
Note
● The employee ID should be less than 32 characters. And it can be a combination of lower
4. Tap the Name field and input the user name on the soft keyboard.
Note
● Numbers, upper case letters, lower case letters, and special characters are allowed in the user
name.
● The suggested user name should be within 32 characters.
57
DS-K1T671 Series Face Recognition Terminal User Manual
Note
The password cannot be edited. It can only be applied by the platform.
6. Set the user role.
Administrator
The user is the administrator. Except for the normal attendance function, the user can also
enter the Home page to operate after authenticating the permission.
Normal User
The User is the normal user. The user can only authenticate or take attendance on the initial
page.
7. Tap to save the settings.
Search User
On the User Management page, Tap the search area to enter the Search User page. Tap Card on
the left of the page and select a search type from the drop-down list. Enter the employee ID, card
No., or the user name for search. Tap to search.
58
DS-K1T671 Series Face Recognition Terminal User Manual
Edit User
On the User Management page, select a user from the user list to enter the Edit User page. Follow
the steps in User Management to edit the user parameters. Tap to save the settings.
Note
The employee ID cannot be edited.
Note
● If you want to transfer all user information from one device (Device A) to another (Device B),
you should export the information from Device A to the USB flash drive and then import from
the USB flash drive to Device B. In this case, you should import the user data before importing
the profile photo.
● The supported USB flash drive format is FAT32.
● The imported pictures should be saved in the folder (named enroll_pic) of the root directory
and the picture's name should be follow the rule below:
Card No._Name_Department_Employee ID_Gender.jpg
● If the folder enroll_pic cannot save all imported pictures, you can create another folders,
named enroll_pic1, enroll_pic2, enroll_pic3, enroll_pic4, under the root directory.
59
DS-K1T671 Series Face Recognition Terminal User Manual
● The employee ID should be less than 32 characters. It can be a combination of lower letters,
upper letters, and numbers. It should not be duplicated, and should not start with 0.
● Requirements of face picture should follow the rules below: It should be taken in full-face
view, directly facing the camera. Do not wear a hat or head covering when taking the face
picture. The format should be JPEG or JPG. The resolution should be 640 × 480 pixel or more
than of 640 × 480 pixel. The picture size should be between 60 KB and 200 KB.
Note
● The supported USB flash drive format is DB.
● The system supports the USB flash drive with the storage of 1G to 32G. Make sure the free
space of the USB flash drive is more than 512M.
● The exported user data is a DB file, which cannot be edited.
60
DS-K1T671 Series Face Recognition Terminal User Manual
Note
The card can be normal IC card, or encrypted card.
QR Code
Put the QR code in front of the device camera to authenticate via QR code.
Note
Authentication via QR code should be supported by the device.
If authentication completed, a prompt "Authenticated" will pop up.
Note
● The card can be normal IC card, or encrypted card.
● If the QR Code Scanning function is enabled, you can put the QR code in front of the device
Note
For detailed information about authenticating face, see Tips When Collecting/Comparing Face
Picture.
If authentication succeeded, the prompt "Authenticated" will pop up.
61
DS-K1T671 Series Face Recognition Terminal User Manual
Note
You can set the voice volume between 0 and 10.
Time Settings
62
DS-K1T671 Series Face Recognition Terminal User Manual
Set the time zone, the device time and the DST.
Sleeping (s)
Set the device sleeping waiting time (minute). When you are on the initial page and if you set
the sleeping time to 30 min, the device will sleep after 30 min without any operation.
Note
If you set the sleeping time to 0, the device will not enter sleeping mode.
Select Language
Select the language according to actual needs.
Community No.
Set the device installed community No.
Building No.
Set the device installed building No.
Unit No.
Set the device installed unit No.
Beauty
You can enable the beauty function and set the smooth and the whiten parameter. Tap + or - to
control the effect strength.
Note
By default, the function is disabled.
63
DS-K1T671 Series Face Recognition Terminal User Manual
Parameter Description
Note
After disabling face anti-spoofing function, there will be spoofing
recognition risks.
Face Recognition Set the valid distance between the user and the camera when
Distance authenticating.
Face Recognition The time interval between two continuous face recognitions when
Interval authenticating.
Note
You can input the number from 1 to 10.
Wide Dynamic It is suggested to enable the WDR function if installing the device
outdoors.
When there are both very bright and very dark areas simultaneously in
the view, you can enable the WDR function to balance the brightness of
the whole image and provide clear images with details.
Face 1:N Security Level Set the matching threshold when authenticating via 1:N matching mode.
The larger the value, the smaller the false accept rate and the larger the
false rejection rate.
Note
You are recommended to retain the default value. The adjustment will
affect the face misidentification rate and rejection rate.
Face 1:1 Security Level Set the matching threshold when authenticating via 1:1 matching mode.
The larger the value, the smaller the false accept rate and the larger the
false rejection rate.
Note
You are recommended to retain the default value. The adjustment will
affect the face misidentification rate and rejection rate.
ECO Settings After enabling the ECO mode, the device will use the IR camera to
authenticate faces in the low light or dark environment. And you can set
the ECO mode threshold, ECO mode (1:N), and ECO mode (1:1).
64
DS-K1T671 Series Face Recognition Terminal User Manual
Parameter Description
Note
After enabling ECO mode, the face will be recognized in weak light or no
light environment. After disabling ECO mode, face recognition effect will
decline in weak light or no light environment.
ECO Mode Threshold
When enabling the ECO mode, you can set the ECO mode's threshold.
The larger the value, the easier the device entering the ECO mode.
ECO Mode (1:1)
Set the matching threshold when authenticating via ECO mode 1:1
matching mode. The larger the value, the smaller the false accept rate
and the larger the false rejection rate.
ECO Mode (1:N)
Set the matching threshold when authenticating via ECO mode 1:N
matching mode. The larger the value, the smaller the false accept rate
and the larger the false rejection rate
Face with Mask & Face(1:N ECO)
Set the matching value when authenticating with face mask via ECO
mode 1:N matching mode. The larger the value, the smaller the false
accept rate and the larger the false rejection rate.
Face with Mask After enabling the face with mask detection, the system will recognize
Detection the captured face with mask picture. You can set face with mask & face
1:N level and the strategy.
Note
After enabling Face with Mask Detection function, recognition effect of
people without mask will be influenced.
Reminder of Wearing
If the person do not wear a face mask when authenticating, the
device prompts a notification and the door will open.
Must Wear
If the person do not wear a face mask when authenticating, the
device prompts a notification and the door keeps closed.
None
65
DS-K1T671 Series Face Recognition Terminal User Manual
Parameter Description
If the person do not wear a face mask when authenticating, the
device will not prompt a notification.
Hard Hat Detection After enabling the hard hat detection, you can set the strategy.
Reminder of Wearing
If the person do not wear the hard hat when authenticating, the
device will pop up a prompt and the door will open.
Must Wear
If the person do not wear the hard hat when authenticating, the
device will pop up a prompt and the door will keep closed.
None
If the person do not wear a face mask when authenticating, the
device will not prompt a notification.
66
DS-K1T671 Series Face Recognition Terminal User Manual
Note
● Biometric recognition products are not completely applicable
to anti-spoofing environments. If you require a higher
security level, use multiple authentication modes.
● If you adopt multiple authentication modes, you should
authenticate other methods before authenticating face.
Reader Auth. Mode (Card Select the card reader's authentication mode.
Reader Authentication Mode)
Enable NFC Card Enable the function and you can present the NFC card to
authenticate. In order to prevent the mobile phone from getting
the data of the access control, you can disable NFC card to
increase the security level of the data.
67
DS-K1T671 Series Face Recognition Terminal User Manual
Parameter Description
Note
Disable NFC card cannot completely avoid presenting NFC card.
Door Contact You can select "Open (Remain Open)" or "Close (Remian
Closed)" according to your actual needs. By default, it is Close
(Remian Closed).
Open Duration Set the door unlocking duration. If the door is not opened for
the set time, the door will be locked. Available door locked time
range: 1 to 255s.
Authentication Interval Set the device authenticating interval. Available authentication
interval range: 0 to 65535.
Note
The function should be used cooperatively with time and attendance function on the client
software.
68
DS-K1T671 Series Face Recognition Terminal User Manual
69
DS-K1T671 Series Face Recognition Terminal User Manual
Note
The Attendance Property will not be changed.
5. Optional: Select an status and change its name if required.
The name will be displayed on the T & A Status page and the authentication result page.
Result
You should select an attendance status manually after authentication.
Note
If you do not select a status, the authentication will be failed and it will not be marked as a valid
attendance.
70
DS-K1T671 Series Face Recognition Terminal User Manual
Note
The Attendance Property will not be changed.
5. Optional: Select an status and change its name if required.
The name will be displayed on the T & A Status page and the authentication result page.
6. Set the status' schedule.
1) Tap Attendance Schedule.
2) Select Monday, Tuesday, Wednesday, Thursday, Friday, Saturday, or Sunday.
3) Set the selected attendance status's start time of the day.
4) Tap Confirm.
5) Repeat step 1 to 4 according to your actual needs.
Note
The attendance status will be valid within the configured schedule.
71
DS-K1T671 Series Face Recognition Terminal User Manual
Result
When you authenticate on the initial page, the authentication will be marked as the configured
attendance status according to the configured schedule.
Example
If set the Break Out as Monday 11:00, and Break In as Monday 12:00, the valid user's
authentication from Monday 11:00 to 12:00 will be marked as break.
72
DS-K1T671 Series Face Recognition Terminal User Manual
Note
The Attendance Property will not be changed.
5. Optional: Select an status and change its name if required.
The name will be displayed on the T & A Status page and the authentication result page.
6. Set the status' schedule.
1) Tap Attendance Schedule.
2) Select Monday, Tuesday, Wednesday, Thursday, Friday, Saturday, or Sunday.
3) Set the selected attendance status's start time of the day.
4) Tap OK.
5) Repeat step 1 to 4 according to your actual needs.
Note
The attendance status will be valid within the configured schedule.
Result
On the initial page and authenticate. The authentication will be marked as the configured
attendance status according to the schedule. If you tap the edit icon on the result tab, you can
select a status to take attendance manually, the authentication will be marked as the edited
attendance status.
Example
If set the Break Out as Monday 11:00, and Break In as Monday 12:00, the valid user's
authentication from Monday 11:00 to 12:00 will be marked as break.
73
DS-K1T671 Series Face Recognition Terminal User Manual
System Information
You can view the device model, serial No., versions, address, production data, QR code, and
open source code license.
Note
The page may vary according to different device models. Refers to the actual page for details.
Capacity
You can view the number of, user, face picture, card, and event.
Device Upgrade
Online Update
If the device has been connected to Hik-Connect and network, when there is a new
installation package in Hik-Connect, you can tap Device Upgrade → Online Update to
upgrade the device system.
Update via USB
74
DS-K1T671 Series Face Recognition Terminal User Manual
Plug the USB flash drive in the device USB interface. Tap Device Upgrade → Update via USB ,
and the device will read the digicap.dav file in the USB flash drive to start upgrading.
Unlink APP Account
After unlinking APP account, you cannot operate via APP.
Restore to Default Settings
All parameters, except for the communication settings, remotely imported user information, will
be restored to the default settings. The system will reboot to take effect.
Restore to Factory Settings
All parameters will be restored to the factory settings. The system will reboot to take effect.
Reboot
Reboot the device.
Advanced Settings
Long Tap ? on the right corner to enter the advanced settings page. Enter the password.
Face Parameter
Custom Anti-Spoofing Detection
Face Liveness Level
After enabling face anti-spoofing function, you can set the matching security level
when performing live face authentication.
Anti-Spoofing Detection Threshold
The larger the value, the smaller the false accept rate and the larger the false rejection
rate. The smaller the value, the larger the false accept rate and the smaller the false
rejection rate.
Lock Face for Anti-Spoofing Protection
After enabling this function, the device will lock automatically when anti-spoofing
detection failed.
Lock Duration
The lock duration after enabling Lock Face for Anti-Spoofing Protection when anti-
spoofing detection failed.
Version Information
You can view the device information.
75
DS-K1T671 Series Face Recognition Terminal User Manual
Note
You can select call type from Call Room, Call Center, Call Specified Room No. and Call APP.
76
DS-K1T671 Series Face Recognition Terminal User Manual
Call Room
When you tap the call button on the authentication page, you should dial a room No. to
call.
Call Center
When you tap the call button on the authentication page, you can call the center directly.
Call Specified Room No.
You should set a room No. When you tap the call button on the authentication page, you
can call the configured room directly without dialing.
Call APP
When you tap the call button on the authentication page, you will call the mobile client
where the device is added.
Password
Enable this function amd you can enter the password to authenticate via password.
Theme
You can set the theme of the prompt window on the authentication page. You can select
Theme as Default, Simple, or Advertisement.
Default
The device authentication page will display the live view page. And the person's name,
employee ID, face pictures will all be displayed after authentication.
Simple
After selecting this mode, the live view of the authentication page will be disabled, and in
the meanwhile, the person's name, employee ID, face pictures will all be hidden after
authentication.
Advertisement
After selecting this mode, the advertising area and identification authentication area of
the device will be displayed on separate screens. Video and advertising information
playback, welcome speech display are supported.
77
DS-K1T671 Series Face Recognition Terminal User Manual
Note
For details about adding device, see Add Device.
5. Call the client software.
1) Tap on the device initial page.
2) Enter 0 in the pop-up window.
3) Tap to call the client software.
6. Tap Answer on the pop-up page of the client software and you can start two-way audio between
the device and the client software.
Note
If the device is added to multiple client softwares and when the device is calling the client
software, only the first client software added the device will pop up the call receiving window.
Note
For details about adding device, see Add Device.
5. Set the main station's IP address and SIP address in the remote configuration page.
Note
For details about the operation, see the user manual of the main station.
6. Call the center.
- If you have configured to call center in the Basic Settings , you can tap to call the center.
- If you have not configured to call center in the Basic Settings , you should tap → to call
the center
7. Answers the call via the main station and starts two-way audio.
78
DS-K1T671 Series Face Recognition Terminal User Manual
Note
The device will call the main station in priority.
Note
For details about adding device, see Add Device.
5. Enter the Live View page and double-click the added device to start live view.
Note
For details about operations in the Live View page, see Live View in the user manual of the client
software.
6. Right click the live view image to open the right-click menu.
7. Click Start Two-Way Audio to start two-way audio between the device and the client software.
Note
For details about adding device, see Add Device.
5. Link a user to an indoor station and set a room No. for the indoor station.
6. Call the room.
- If you have configured a specified room No. in the Basic Settings , you can tap to call the
room.
- If you have not configured a specified room No. in the Basic Settings , you should tap on
the authentication page of the device. Enter the room No. on the dial page and tap to call
the room.
7. After the indoor station answers the call, you can start two-way audio with the indoor station.
79
DS-K1T671 Series Face Recognition Terminal User Manual
Note
For details, see the user manual of the mobile client.
3. Enter Basic Settings → Shortcut Key and enable Call APP.
4. Go back to the initial page and call the mobile client.
1) Tap on the device initial page.
2) Tap to call the mobile client.
80
DS-K1T671 Series Face Recognition Terminal User Manual
Note
After you change the system language, the device will reboot automatically.
81
DS-K1T671 Series Face Recognition Terminal User Manual
Note
You should select at least one credential.
1) Click Add Face to upload a face picture from local storage.
Note
The uploaded picture should be within 200 K, in JPG、JPEG、PNG format.
2) Click Add Card to enter the Card No. and select the property of the card.
Note
Up to 5 cards can be supported.
3) Click Add Fingerprint to add fingerprints.
Note
Up to 10 fingerprints are allowed.
Click Complete to complete the settings.
82
DS-K1T671 Series Face Recognition Terminal User Manual
Note
The main door station No. is 0, and the sub door station No. ranges from 1 to 16.
Community No.
Set the device community No.
Building No.
Set the device building No.
Unit No.
Set the device unit No.
83
DS-K1T671 Series Face Recognition Terminal User Manual
9.1 Login
You can login via the web browser.
Note
Make sure the device is activated. For detailed information about activation, see Activation .
Note
You can change the device password via PC web.
1. ClickForgot Password on the login page.
2. Select the verification method.
3. Answer the reserved security questions.
Note
The answers are configured when you first activate the device.
4. Create a new password and confirm the password.
5. Click Next to save the settings.
9.3 Overview
You can view the live video of the device, person information, network status, basic information,
and device capacity.
84
DS-K1T671 Series Face Recognition Terminal User Manual
Note
If you adjust the volume when starting two-way audio, you may hear a repeated sounds.
Select the streaming type when starting live view. You can select from the main stream, sub
stream or third stream.
85
DS-K1T671 Series Face Recognition Terminal User Manual
86
DS-K1T671 Series Face Recognition Terminal User Manual
87
DS-K1T671 Series Face Recognition Terminal User Manual
Note
The picture format should be JPG or JPEG or PNG, and the size should be less than 200 K.
Note
Up to 50 cards can be added.
Click Save to save the settings.
Add Fingerprint
Note
Only devices supporting the fingerprint function can add the fingerprint.
88
DS-K1T671 Series Face Recognition Terminal User Manual
9.6 Configuration
89
DS-K1T671 Series Face Recognition Terminal User Manual
Click Configuration → System → System Settings → Basic Information to enter the configuration
page.
You can view device name, language, model, serial No., version, IO input, IO output, Lock, Local
RS-485,alarm input, alarm output, and device capacity, etc.
90
DS-K1T671 Series Face Recognition Terminal User Manual
Caution
The password strength of the device can be automatically checked. We highly recommend you
change the password of your own choosing (using a minimum of 8 characters, including at least
three kinds of following categories: upper case letters, lower case letters, numbers, and special
characters) in order to increase the security of your product. And we recommend you change
your password regularly, especially in the high security system, changing the password monthly
or weekly can better protect your product.
Proper configuration of all passwords and other security settings is the responsibility of the
installer and/or end-user.
Note
Some device models do not support Wi-Fi or mobile data settings. Refer to the actual products
when configuration.
91
DS-K1T671 Series Face Recognition Terminal User Manual
92
DS-K1T671 Series Face Recognition Terminal User Manual
Note
The function should be supported by the device.
1. Click Configuration → Network → Network Settings → Wi-Fi .
93
DS-K1T671 Series Face Recognition Terminal User Manual
HTTP
It refers to the port through which the browser accesses the device. For example, when the
HTTP Port is modified to 81, you need to enter http://192.0.0.65:81 in the browser for login.
HTTPS
Set the HTTPS for accessing the browser. Certificate is required when accessing.
HTTP Listening
The device can send alarm information to the event alarm IP address or domain name via HTTP
protocol/HTTPS protocol. Edit the event alarm IP address or domain name, URL, port, and
protocol.
Note
The event alarm IP address or domain name should support the HTTP protocol/HTTPS protocol
to receive the alarm information.
Click Configuration → Network → Network Service → RTSP .
RTSP
It refers to the port of real-time streaming protocol.
Click Configuration → Network → Device Access → SDK Server .
SDK Server
It refers to the port through which the client adds the device.
Platform Access
Platform access provides you an option to manage the devices via platform.
Steps
1. Click Configuration → Network → Device Access → Hik-Connect to enter the settings page.
Note
Hik-Connect is an application for mobile devices. With the App, you can view live image of the
device, receive alarm notification and so on.
2. Check Enable to enable the function.
3. Optional: Check the checkbox of Custom, and you can set the server address by yourself.
4. Enter the server IP address, and verification code.
Note
6 to 12 letters (a to z, A to Z) or numbers (0 to 9), case sensitive. You are recommended to use a
combination of no less than 8 letters or numbers.
5. Enable Video Encryption, and create the password and confirm it.
94
DS-K1T671 Series Face Recognition Terminal User Manual
Note
After adding the device to APP, you need to enter the video encryption password to live view the
device.
6. Optional: Click View to view the device QR code. Scan the QR code to account.
Note
Scan the QR code before it loses efficacy.
7. Optional: Click More to set the network connection priority.
1) Enable WLAN or Wired Network according to your actual needs.
1) Hold and drag to adjust the access priority.
8. Click Save to enable the settings.
Note
The function should be supported by the device.
1. Click Configuration → Network → Device Access → ISUP .
2. Check Enable.
3. Set the ISUP version, server address, port, device ID, and the ISUP status.
Note
If you select 5.0 as the version, you should set the encryption key as well.
4. Set the ISUP listening parameters, including ISUP alarm center IP address/domain name, ISUP
alarm center URL, and ISUP alarm center port.
5. Click Save.
95
DS-K1T671 Series Face Recognition Terminal User Manual
Note
The functions vary according to different models. Refers to the actual device for details.
96
DS-K1T671 Series Face Recognition Terminal User Manual
Note
The functions vary according to different models. Refers to the actual device for details.
97
DS-K1T671 Series Face Recognition Terminal User Manual
You can set the authentication interval of the same person when authenticating. The same
person can only authenticate once in the configured interval. A second authentication will be
failed.
Alarm of Max. Failed Attempts
Enable to report alarm when the card reading attempts reach the set value.
Tampering Detection
Enable the anti-tamper detection for the card reader.
Card No. Reversing
The read card No. will be in reverse sequence after enabling the function.
If select Terminal 2:
Terminal/Terminal Type/Terminal Model
Select terminal and get the terminal description. They are read-only.
Enable Authentication Device
Enable the authentication function.
Sub Card Reader Position
You can select sub card reader position as different or same side as the main card reader.
Authentication
Select an authentication mode according to your actual needs from the drop-down list.
Recognition Interval
You can set the interval between 2 continuous recognition of a same person during the
authentication. In the configured interval, Person A can only recognized once. If another person
(Person B) has recognized during the interval, Person A can recognized again.
Alarm of Max. Failed Attempts
Enable to report alarm when the card reading attempts reach the set value.
Communication with Controller Every
When the access control device cannot connect with the card reader for longer than the set
time, the card reader will turn offline automatically.
Max. Interval When Entering Password
When you entering the password on the card reader, if the interval between pressing two digits
is longer than the set value, the digits you pressed before will be cleared automatically.
OK LED Polarity/Error LED Polarity
Set OK LED Polarity/Error LED Polarity of the access control device according to the card reader
parameters. Generally, adopts the default settings.
Tampering Detection
Enable the anti-tamper detection for the card reader.
98
DS-K1T671 Series Face Recognition Terminal User Manual
99
DS-K1T671 Series Face Recognition Terminal User Manual
You can set the door lock status when the door lock is powering off. By default, it is Remain
Closed.
Extended Open Duration
The door contact can be enabled with appropriate delay after person with extended access
needs swipes her/his card.
Door Remain Open Duration with First Person
Set the door open duration when first person is in. After the first person is authorized, it allows
multiple persons access the door or other authentication actions.
Duress Code
The door can open by inputting the duress code when there is duress. At the same time, the
client can report the duress event.
Super Password
The specific person can open the door by inputting the super password.
Note
The duress code and the super code should be different.
Note
After the peripheral is changed and saved, the device will reboot automatically.
RS-485 Address
Set the RS-485 Address according to your actual needs.
100
DS-K1T671 Series Face Recognition Terminal User Manual
Note
If you select Access Controller: If connect the device to a terminal via the RS-485 interface, set
the RS-485 address as 2. If you connect the device to a controller, set the RS-485 address
according to the door No.
Baud Rate
The baud rate when the devices are communicating via the RS-485 protocol.
Note
Some device models do not support this function. Refer to the actual products when configuration.
1. Click Configuration → Access Control → Wiegand Settings .
2. Check Wiegand to enable the Wiegand function.
3. Set a transmission direction.
Input
The device can connect a Wiegand card reader.
Output
The can connect an external access controller. And the two devices will transmit the card No.
via Wiegand 26 or 34.
4. Click Save to save the settings.
Note
If you change the peripheral, and after you save the device parameters, the device will reboot
automatically.
101
DS-K1T671 Series Face Recognition Terminal User Manual
Note
If you change the device type, you should reboot the device.
Floor No.
Set the device installed floor No.
102
DS-K1T671 Series Face Recognition Terminal User Manual
Note
● If you change the No., you should reboot the device.
● The main door station No. is 0, and the sub door station No. ranges from 1 to 16.
Community No.
Set the device community No.
Building No.
Set the device building No.
Unit No.
Set the device unit No.
Note
If you change the No., you should reboot the device.
If set the device type as Outer Door Station, you can set outer door station No., and community
No.
Outer Door Station No.
If you select outer door station as the device type, you should enter a number between 1 and
99.
Note
If you change the No., you should reboot the device.
Community No.
Set the device community No.
103
DS-K1T671 Series Face Recognition Terminal User Manual
2. Check Call Indoor Station, Call Specified Indoor Station, Call Management Center or APP at
your needs.
Note
If you check Call Specified Indoor Station, you need to enter the number of the indoor station.
3. Click Save.
Note
Disable NFC card cannot completely avoid presenting NFC card.
Enable M1 Card
Enable M1 card and authenticating by presenting M1 card is available.
M1 Card Encryption
Sector
M1 card encryption can improve the security level of authentication.
104
DS-K1T671 Series Face Recognition Terminal User Manual
Enable the function and set the encryption sector. By default, Sector 13 is encrypted. It is
recommended to encrypt sector 13.
Enable EM Card
Enable EM card and authenticating by presenting EM card is available.
Enable DESFire Card
The device can read the data from DESFire card when enabling the DESFire card function.
Enable FeliCa Card
The device can read the data from FeliCa card when enabling the FeliCa card function.
105
DS-K1T671 Series Face Recognition Terminal User Manual
Note
The Attendance Property will not be changed.
5. Optional: Select an status and change its name if required.
Result
You should select an attendance status manually after authentication.
Note
If you do not select a status, the authentication will be failed and it will not be marked as a valid
attendance.
Note
The Attendance Property will not be changed.
5. Optional: Select an status and change its name if required.
6. Set the status' schedule. Refers to for details.
106
DS-K1T671 Series Face Recognition Terminal User Manual
Note
The Attendance Property will not be changed.
5. Optional: Select an status and change its name if required.
6. Set the status' schedule. Refers to for details.
Result
On the initial page and authenticate. The authentication will be marked as the configured
attendance status according to the schedule. If you tap the edit icon on the result tab, you can
select a status to take attendance manually, the authentication will be marked as the edited
attendance status.
Example
If set the Break Out as Monday 11:00, and Break In as Monday 12:00, the valid user's
authentication from Monday 11:00 to 12:00 will be marked as break.
Authentication Settings
Display Authentication Result
You can check Face Picture, Name, Employee ID and Temperature to display the authentication
result.
Name De-identification
107
DS-K1T671 Series Face Recognition Terminal User Manual
You can check Name De-identification, and the whole name will not be displayed.
Note
All pictures cannot be restored once they are deleted.
Clear Registered Face Pictures
All registered pictures in the device will be deleted.
Clear Captured Pictures
All captured pictures in the device will be deleted.
108
DS-K1T671 Series Face Recognition Terminal User Manual
Note
The functions vary according to different models. Refers to the actual device for details.
109
DS-K1T671 Series Face Recognition Terminal User Manual
Enable or disable the live face detection function. If enabling the function, the device can
recognize whether the person is a live one or not.
Note
● Biometric recognition products are not 100% applicable to anti-spoofing environments. If you
require a higher security level, use multiple authentication modes.
● After disabling face anti-spoofing function, there will be spoofing recognition risks.
Note
You are recommended to retain the default value. The adjustment will affect the face
misidentification rate and rejection rate.
1:N Matching Threshold
Set the matching threshold when authenticating via 1:N matching mode. The larger the value,
the smaller the false accept rate and the larger the false rejection rate.
Note
You are recommended to retain the default value. The adjustment will affect the face
misidentification rate and rejection rate.
Face Recognition Timeout Value
Set the timeout value when face recognizing. If the face recognition time is longer than the
configured value, the system will pop up a prompt.
ECO Mode
110
DS-K1T671 Series Face Recognition Terminal User Manual
After enabling the ECO mode, the device will use the IR camera to authenticate faces in the low
light or dark environment. And you can set the ECO mode threshold, ECO mode (1:N), and ECO
mode (1:1).
Note
After enabling ECO mode, the face will be recognized in weak light or no light environment.
After disabling ECO mode, face recognition effect will decline in weak light or no light
environment.
ECO Mode Threshold
The larger the value, the device enter the ECO Mode easier.
ECO Mode (1:1)
Set the matching threshold when authenticating via ECO mode 1:1 matching mode. The larger
the value, the smaller the false accept rate and the larger the false rejection rate.
ECO Mode (1:N)
Set the matching threshold when authenticating via ECO mode 1:N matching mode. The larger
the value, the smaller the false accept rate and the larger the false rejection rate
Face with Mask Detection
After enabling the face with mask detection, the system will recognize the captured face with
mask picture or not. You can set face with mask1:N matching threshold, it's ECO mode, and the
strategy.
Note
After enabling Face with Mask Detection function, recognition effect of people without mask
will be influenced.
None
The function is disabled. The device will not detect whether a person is wearing a face mask
or not.
Reminder of Wearing Face Mask
If the person do not wear the face mask when authenticating, the device will pop up a
prompt and the door will open.
Must Wear Face Mask
If the person do not wear the face mask when authenticating, the device will pop up a
prompt and the door will keep closed.
Face with Mask & Face (1:1)
Set the matching value when authenticating with face mask via 1:1 matching mode. The larger
the value, the smaller the false accept rate and the larger the false rejection rate.
Face with Mask 1:N Matching Threshold
111
DS-K1T671 Series Face Recognition Terminal User Manual
Set the matching threshold when authenticating with face mask via 1:N matching mode. The
larger the value, the smaller the false accept rate and the larger the false rejection rate.
Face with Mask & Face (1:1 ECO)
Set the matching value when authenticating with face mask via ECO mode 1:1 matching mode.
The larger the value, the smaller the false accept rate and the larger the false rejection rate.
Face with Mask 1:N Matching Threshold (ECO Mode)
Set the matching threshold when authenticating with face mask via ECO mode 1:N matching
mode. The larger the value, the smaller the false accept rate and the larger the false rejection
rate.
Enable Hard Hat Detection
After enabling the hard hat detection, you can set the strategy.
None
The function is disabled. The device will not detect whether a person is wearing a hard hat or
not.
Reminder of Wearing
If the person do not wear the hard hat when authenticating, the device will pop up a prompt
and the door will open.
Must Wear
If the person do not wear the hard hat when authenticating, the device will pop up a prompt
and the door will keep closed.
Set Preference
You can set the display theme and the sleep time for the device.
Set Theme
Click Configuration → Preference .
112
DS-K1T671 Series Face Recognition Terminal User Manual
Sleep
Enable Sleep and the device will enter the sleep mode when no operation within the configured
sleep time.
Display Mode
You can select display theme for device authentication. You can select Display Mode as
Authentication, Simple or Advertisement. When you select Simple, the information of name,
ID, face picture will be not displayed.
Notice Publication
You can set the notice publication for the device.
Click Configuration → Preference → Notice Publication .
Theme Management
Click Media Library Management → + to upload the picture from the local PC.
You can click +, and set Name and Type to create a theme. After creating the theme, click + in
the Theme Management panel to select pictures in the media library. Click OK to add pictures
to the theme.
113
DS-K1T671 Series Face Recognition Terminal User Manual
Note
If authentication is succeeded in the configured time duration, the device will broadcast the
configured content.
3) Enter the audio content.
4) Optional: Repeat substep 1 to 3.
5) Optional: Click to delete the configured time duration.
6. Set the time duration when authentication failed.
1) Click Add Time Duration.
2) Set the time duration and the language.
114
DS-K1T671 Series Face Recognition Terminal User Manual
Note
If authentication is failed in the configured time duration, the device will broadcast the
configured content.
3) Enter the audio content.
4) Optional: Repeat substep 1 to 3.
5) Optional: Click to delete the configured time duration.
7. Click Save.
Note
The uploaded audio file should be less than 512 kb, in WAV format.
Reboot Device
Click Maintenance and Security → Maintenance → Restart .
Click Restart to reboot the device.
Upgrade
Click Maintenance and Security → Maintenance → Upgrade .
Select an upgrade type from the drop-down list. Click and select the upgrade file from your
local PC. Click Upgrade to start upgrading.
If the device has been connected to Hik-Connect and network, when there is a new installation
package in Hik-Connect, you can click Upgrade after Online Update to upgrade the device system.
115
DS-K1T671 Series Face Recognition Terminal User Manual
Note
Do not power off during the upgrading.
Restore Parameters
Click Maintenance and Security → Maintenance → Backup and Reset .
Restore All
All parameters will be restored to the factory settings. You should activate the device before
usage.
Restore
The device will restore to the default settings, except for the device IP address and the user
information.
Note
You can import the exported device parameters to another device.
Import
Click and select the file to import. Click Import to start import configuration file.
Click Advanced Settings, and enter the admin password.
Face Parameter
Custom Anti-Spoofing Detection
Face Liveness Level
After enabling face anti-spoofing function, you can set the matching security level when
performing live face authentication.
Anti-Spoofing Detection Threshold
The larger the value, the smaller the false accept rate and the larger the false rejection
rate. The smaller the value, the larger the false accept rate and the smaller the false
rejection rate.
Lock Face for Anti-Spoofing Protection
After enabling this function, the device will lock automatically when anti-spoofing detection
failed.
Lock Duration
116
DS-K1T671 Series Face Recognition Terminal User Manual
The lock duration after enabling Lock Face for Anti-Spoofing Protection when anti-spoofing
detection failed.
Unlock
You can click Unlock according to your needs.
Version Information
You can view the device information.
117
DS-K1T671 Series Face Recognition Terminal User Manual
Security Mode
High security level for user information verification when logging in the client software.
Compatible Mode
The user information verification is compatible with the old client software version when
logging in.
Note
The function is only supported by certain device models.
118
DS-K1T671 Series Face Recognition Terminal User Manual
3. Click Install.
Install CA Certificate
Before You Start
Prepare a CA certificate in advance.
Steps
1. Go to Configuration → System → Security → Certificate Management .
2. Create an ID in the Inport CA Certificate area.
Note
The input certificate ID cannot be the same as the existing ones.
3. Upload a certificate file from the local.
4. Click Install.
119
DS-K1T671 Series Face Recognition Terminal User Manual
120
DS-K1T671 Series Face Recognition Terminal User Manual
Recommended Finger
Forefinger, middle finger or the third finger.
Correct Scanning
The figure displayed below is the correct way to scan your finger:
You should press your finger on the scanner horizontally. The center of your scanned finger should
align with the scanner center.
Incorrect Scanning
The figures of scanning fingerprint displayed below are incorrect:
121
DS-K1T671 Series Face Recognition Terminal User Manual
Environment
The scanner should avoid direct sun light, high temperature, humid conditions and rain.
When it is dry, the scanner may not recognize your fingerprint successfully. You can blow your
finger and scan again.
Others
If your fingerprint is shallow, or it is hard to scan your fingerprint, we recommend you to use other
authentication methods.
If you have injuries on the scanned finger, the scanner may not recognize. You can change another
finger and try again.
122
DS-K1T671 Series Face Recognition Terminal User Manual
Expression
● Keep your expression naturally when collecting or comparing face pictures, just like the
expression in the picture below.
● Do not wear hat, sunglasses, or other accessories that can affect the facial recognition function.
● Do not make your hair cover your eyes, ears, etc. and heavy makeup is not allowed.
Posture
In order to get a good quality and accurate face picture, position your face looking at the camera
when collecting or comparing face pictures.
123
DS-K1T671 Series Face Recognition Terminal User Manual
Size
Make sure your face is in the middle of the collecting window.
124
DS-K1T671 Series Face Recognition Terminal User Manual
Bulb: 100~850Lux
2. Install the device at least 2 meters away from the light, and at least 3 meters away from the
window or door.
125
DS-K1T671 Series Face Recognition Terminal User Manual
Appendix D. Dimension
126
UD15654B-G