You are on page 1of 6

40QGV Series

Floor Standing Split System


18,100 - 60,700 BTU/H

Black Acrylic Front Panel


(Standard)

38TGV0131A1 38TGV(018-24)1A1 38TGV(025-040)1A* 38TGV0481A3 38TGV0601A3


 RoHS 1155-2557 1529-2561 TLS 8001-2020

www.carrier.co.th
)HDWXUH
¾œ|šƒ³¤®®ƒ¿››¾†¤¸Æ®‰˜¶Æ›³‰ƒ¤±˜²•¤²•˜´Á¬nœ¤±¬£²•Ÿ¸Çš˜¶ÆÁšƒ³¤–µ•–²Ç‰¾„n³ƒ²›¬n®‰Â•n¬¦³£¤ºœ¿››
Å
5HWXUQ$LU*ULOOHŒm®‰š´®³ƒ³©ƒ¦² ›¾„n³¾†¤¸Æ®‰—ºƒ®®ƒ¿››¢³Á¬n®£ºm•n³š„n³‰˜´Á¬nƒ³¤˜´‰³š„®‰¾†¤¸Æ®‰¾‰¶£›¿¦±‰m³£–m®ƒ³¤›´¤¹‰¤²ƒª³

5HPRWH&RQWURO
Š®/&'„š³•Á¬çm•¶Âšq¬¤º˜²š«¢²£‰m³£–m®ƒ³¤†¨›†¹¢•n¨£¤±››œ¹h¢«²¢²«¢¶ z‰ƒqŒ²Āš¬¦³ƒ¬¦³£
1HZ

SMART WiFi

Wired remote controller Wired remote controller Wired remote controller Wired remote controller Wireless remote controller Wired remote controller
CARR-AMT09E CARR-AMT09E-WIFI CARR-AMT32E 40VCW534SJEE CARR-ACXU31CP-E CARR-AMT0AE
(Standard) (Option) (Option) (Option) (Option) (Standard)
«´¬¤²›˜•¿˜š¤¹mš&$55$07(
¾¤µĀ¢Š´¬šĄ³£¾•¸®š«µ‰¬³†¢
5HPRWHKDQGVHW
Áš'LVSOD\SDQHOŠ±¢¶–²¨¤²›«²è賔†´«²Ā‰Š³ƒ–²¨£µ‰Â¤n«³£
5HPRWHKDQGVHW «³¢³¤—«²Ā‰ƒ³¤˜´‰³šŠ³ƒ¤±£±Âƒ¦Â•n :LUHG5HPRWH&RQWUROOHU&$55$07(ZLIL 2SWLRQ 
:LUHOHVVUHPRWHFRQWUROOHU «³¢³¤—†¨›†¹¢ƒ³¤˜´‰³šm³š6PDUW3KRQH7DEOHW
–²Ç‰®¹”¬¡º¢µÂ•n–²Ç‰¿–m& ·Ā‰‰m³£–m®ƒ³¤ÁŒn‰³š¢m¨m³Š±®£ºm˜¶Æ¬šƒÅ¾œc•œc•†¨›†¹¢®¹”¬¡º¢µ•n¨£
œ¤²›†¨³¢¾¤Å¨Ÿ²•¦¢Â•n¤±•²›/R0HG+LŸ¤n®¢À¬¢•)DQ$XWR $SSOLFDWLRQ&DUULHU6PDUWZLIL
6ZLQJ)XQFWLRQÀ¬¢•ƒ¤±Š³£¦¢Á¬n˜²Ā¨˜¹ƒ¢¹¢„®‰¬n®‰À•£®²–Àš¢²–µ

®¹œƒ¤”qœi®‰ƒ²š¾Ÿ¸Æ®¾ŸµĀ¢œ¤±«µ˜™µ¡³Ÿƒ³¤˜´‰³š
¿‰†®¦£q¾£Åš¿››%OXH)LQ¾†¦¸®›«³¤(SR[\˜¶Æµ¨)LQœi®‰ƒ²šƒ³¤ƒ²•ƒ¤m®š˜¶Æ¾ƒµ•Š³ƒ2[LGDWLRQ
Ÿ¤n®¢¾†¦¸®›«³¤+\GURSKLOLF˜´Á¬nšÇ´Â¢m¾ƒ³±¿mš)LQ¾ŸµĀ¢œ¤±«µ˜™µ¡³ŸÁšƒ³¤—m³£¾˜†¨³¢¤n®š

$FU\OLF)URQW3DQHO 2SWLRQ&RORU
ž³¬šn³¾†¤¸Æ®‰«³¢³¤—¾œ¦¶Æ£š«¶¿¦±¨²«•¹¾œ|š$FU\OLF•n–³¢˜¶Æ–n®‰ƒ³¤•¶Â•q¾¤¶£›¬¤º«¨£‰³¢ƒ¦¢ƒ¦¸šƒ²›˜¹ƒƒ³¤®®ƒ¿››
F100 920 303 222 913 238 940 299 919 911 926 941 917 914
¿‰†¨›†¹¢®²Š‹¤µ£± 1(:
¿‰†¨›†¹¢¤¹mšÁ¬¢m 6XUJHSURWHFWLRQ
—ºƒ®®ƒ¿››Á¬n˜š˜³š–m®ž¹hš¦±®®‰†¨³¢Œ¸Çš¿¦±«µĀ‰«ƒœ¤ƒÂ•n œi®‰ƒ²š¿¤‰•²šÂ i³ƒ¤±Œ³ƒŠ³ƒ¡³£š®ƒ
6WDEOHRSHUDWLRQ $ODUP/('
¾†¤¸Æ®‰«³¢³¤—˜´‰³šÂ•nÁšŒm¨‰†¨³¢–m³‰©²ƒ£q i³Š³ƒ†m
+ ³œƒ–µ ¢¶¬¦®•Â ¿Šn‰¾–¸®š¾¢¸Æ®¢¶ƒ³¤˜´‰³šµ•Ÿ¦³•
0LVVHGSKDVHZLULQJSURWHFWLRQ «´¬¤²›¤¹mš˜¶ÆÁŒnƒ²›¤±››Â i³¾ «
¢¶¿‰¨‰Š¤œi®‰ƒ²šƒ³¤–m®«³£Â ¾ ««¦²›ƒ²š
¾†¤¸Æ®‰«³¢³¤—˜´‰³šÂ•n¿¢n¨m³Š±¢¶ƒ³¤Šm³£Â i³«¦²›¾ «

¤±››ƒ³¤˜´‰³š˜¶Æ«¢›º¤”q¿›› %DW:LQJ)DQ 1(:


¤±››ƒ³¤˜´‰³š¾¤µĀ¢Á¬¢m®²–Àš¢²–µ¬¦²‰Š³ƒÂ i³„²•„n®‰ Á›Ÿ²•¦¢•¶ÂšqÁ¬¢mŒm¨£¾ŸµĀ¢œ¤±«µ˜™µ¡³ŸÁšƒ³¤¤±›³£†¨³¢¤n®š
$XWR5HVWDUWHYHQDIWHUDEODFNRXW  ¿¦±¦•¾«¶£‰Áš„”±˜´‰³š
¾¢¸Æ®Â i³ƒ¦²›«ºm¡³¨±œƒ–µ¤±››Š±˜´‰³šÁ¬¢m
®²–Àš¢²–µÁšÀ¬¢•ƒ³¤˜´‰³š˜¶Æ–²Ç‰†m³Â¨n··Ā‰¤±››
Š±›²š˜·ƒƒm®šÂ i³„²•„n®‰˜´Á¬n¢m–n®‰–²Ç‰†m³Á¬¢m˜¹ƒ†¤²Ç‰

&2035(6625 1(: 6WUDLQHU


7ZLQURWDU\FRPSUHVVRU¾œ|š†®¢¾Ÿ¤«¾®¤q˜¶ÆŸ²“š³„·ÇšÁ¬¢m ¡³£Áš¾†¤¸Æ®‰&'8¢¶®¹œƒ¤”q˜¶Æ¾¤¶£ƒ¨m³6WUDLQHU˜¶ÆŒm¨£ƒ¤®‰¿¦±
˜´Á¬n¢¶„š³•˜¶Æ¾¦Åƒ¦‰¿¦±¦•¿¤‰«²Āš„®‰†®¢¾Ÿ¤«¾®¤q„”±˜´‰³š œi®‰ƒ²š«µĀ‰«ƒœ¤ƒ¡³£Áš¤±››ƒ³¤˜´†¨³¢¾£Åš
¾¢¸Æ®¾œ¦¶Æ£š¾†¤¸Æ®‰œ¤²›®³ƒ³©˜¶ÆÁŒn«³¤˜´†¨³¢¾£Åš5
«³¢³¤—ÁŒn˜m®«³¤˜´†¨³¢¾£Åš¾•µ¢·Ā‰œ¤±¬£²•¾¨¦³Ášƒ³¤–µ•–²Ç‰ Refrigerant cycle diagram

5HPDUN–n®‰¦n³‰˜m®¿¦±–¤¨Š«®›„š³•˜m®ƒm®šƒ³¤–µ•–²Ç‰

®¹”¬¡º¢µ¡³£š®ƒ

XPower has wide operation range which satisfy user needs.

5HPRWHFRQWUROOHU
Wired Remote Controller

)XQFWLRQ

Lite vision plus Standards plus Standards WIFI Standards (new)*


Model Name CARR-AMT09E-
40VCW534SJEE CARR-AMT32E CARR-AMT09E CARR-AMT0AE
WIFI
Start / Stop
Mode
Setting Temperature

Fan Speed

Timer Function

Schedule Function - - - -
WIFI support - - - -

Energy Save Function - - - -


Filter dirty indicator - - -

Error Display

«Ë³¬¤²›˜•¿˜š¤¹mš&$55$07(¾¤µĀ¢ŠË³¬šĄ³£&$55$07$(¾•¸®š«µ‰¬³†¢
/&5(027(&21752//(5
Wired remote controller

Single controllers 2 Remote controllers Group n = 16

Only Wired remote control model 40VCW534SJEE / CARR-AMT32E

&RQGHQVLQJXQLW

'XUDELOLW\ 6HDOHGXSLQYHUWHUER[
$OXPLQXP$OOR\Š±¾›³ƒ¨m³˜®‰¿•‰ Œ¹•ƒ¦m®‰†¨›†¹¢,QYHUWHU„®‰;SRZHU—ºƒœc•š·ƒ
—·‰Áš ®£m³‰«¢›º¤”q¾Ÿ¸Æ®œi®‰ƒ²šž¹hš˜¤³£¿¦±«²–¨q„š³•¾¦Åƒ
¿‰†®¦£q¤n®š¦µ–Š³ƒ$OXPLQXP$OOR\
«¢«³¤Œšµ•Ÿµ¾©ª¾Ÿ¸Æ®œi®‰ƒ²šƒ³¤ƒ²•ƒ¤m®š Inverter box
Dust
)LQJXDUGLQVWDOOHG
Sands
¾ŸµĀ¢†¨³¢œ¦®•¡²£À•£ƒ³¤–µ•–²Ç‰)LQJXDUG«´¬¤²›
œi®‰ƒ²š®²š–¤³£Š³ƒ†¤¶›„®‰¿‰¤±›³£†¨³¢¤n®š
Small animal
3ODVWLFMRLQWFRYHUDQGUXEEHUVKHHWLQVWDOOHG $QWL&RUURVLRQ
£¸•®³£¹ƒ³¤ÁŒn‰³šÁ¬n£³¨š³š„·ÇšÀ•£ƒ³¤œi®‰ƒ²š ¾˜†ÀšÀ¦£¶Á¬¢m„®‰¿‰¤±›³£†¨³¢¤n®š˜¶Æ–n³š˜³š
˜¹ƒ¤®£–m®Ÿ¦³«–µƒ¿¦±¿mš£³‰Œšµ•Ÿµ¾©ª ƒ³¤ƒ²•ƒ¤m®š•n¨£$OXPLQLXP$OOR\˜¶Æ¢¶œ¤±«µ˜™µ¡³Ÿ
¤±¬¨m³‰¿‰¤±›³£†¨³¢¤n®š¿¦±–²¨¾†¤Æ¸Æ®‰ Ášƒ³¤¤±›³£†¨³¢¤n®š˜š˜³ššÇ´¬š²ƒ¾›³
˜¶Æ˜´Š³ƒ¾¬¦Åƒ¾†¦¸®›«¶¾Ÿ¸Æ®œi®‰ƒ²šƒ³¤¾«¶£•«¶ œ¤±¬£²•Ÿ¦²‰‰³š
¿¦±¦•ƒ³¤ƒ²•ƒ¤m®š
Rubber sheet
ÖŠĂîÖćøìéÿĂï ĀúĆÜÖćøìéÿĂï

3ODᑌLFMRLQWFRYHU
ÿõćóðÖêĉ õćóúąđĂĊ÷éõć÷ĔêšÖúšĂÜÝčúìøøýîŤ
¬¦²‰Š³ƒm³šƒ³¤˜•«®›6SUD\7HVW®£m³‰¬š²ƒ®¹œƒ¤”qŒ¹•¿¦ƒ¾œ¦¶Æ£š
†¨³¢¤n®š 3)& «³¢³¤—†‰¤ºœÂ•nÀ•£Â¢m¢¶ƒ³¤ƒ²•ƒ¤m®š¢¶†¨³¢˜š˜³š
3ODᑌLFFRYHU
¾œ|š®£m³‰•¶¿¢n®£ºmÁš«¡³¨±˜¶Æ¢¶ƒ³¤ƒ²•ƒ¤m®š«º‰

Adjustable Fan Speed with AUTO FAN cools down the room quickly. Evironmental friendly, with R-32 refrigerant
The latest innovation from the world
MICROPROCESSOR enables precise temperature control up to 1 degree Celsius. Blue fin with Epoxcy and Hydrophilic coating
leader in air conditioning, Carrier,
Washable filter enhances Indoor Air Quality. - Prevents dirt from sticking to the fins
introduces the all-new floor standing
split air conditioning system. New slim design and new color make 40QGV blended to your decor of any room. - Condensation water flows and water away dirt
The 40QGV millennium design, Durable anti-rust casing helps the unit last longer. - Anty-corrosion caused by oxidation
inside and out, will provide you with Automatic restart the air conditioner after the power failure. - Increases the efficiency of heat exchanger
cool comfort via a variety of control
functions.

Floor Standing - Inverter control


Specification (/>.1<I9A. 9I/CQ9)
(/Dô%!Eõ!=R*CR% J&&3&D->/#V>>% õ3.9@%I39/øI!9/ø)
Model Name (CQ9/Dô%) Outdoor Unit (I/CQ9,>.%9) 38TGV0181A1 38TGV0241A1 38TGV0301A1 38TGV0361A1 38TGV0361A3 38TGV0401A1 38TGV0401A3 38TGV0481A3 38TGV0601A3
Indoor Unit (I/CQ9,>.L%) 40QGV0181HP 40QGV0241HP 40QGV0301HP 40QGV0361HP 40QGV0361HP 40QGV0401HP 40QGV0401HP 40QGV0481HP 40QGV0601HP
Cooling Capacity (Min. Hz./Rate Hz./ Max Hz. ) Min Rate Max Min Rate Max Min Rate Max Min Rate Max Min Rate Max Min Rate Max Min Rate Max Min Rate Max Min Rate Max
(3>-6>->/"L%>/#V>3>-I.P%) Kw. 1.2 5.3 5.6 1.2 7.1 8.0 3.0 8.8 10.0 4.0 10.6 11.2 4.0 10.6 11.2 4.0 11.8 13.2 4.0 11.8 13.2 4.0 14.1 15.9 4.0 17.8 18.5
Btu/hr. 4,100 18,100 19,100 4,100 24,200 27,200 10,200 30,000 34,100 13,600 36,100 38,200 13,600 36,100 38,200 13,600 40,200 45,000 13,600 40,200 45,000 13,600 48,000 54,200 13,600 60,700 63,100
Efficiency (ô>'/<6@#$@,>*) SEER. 21.10 19.60 19.60 17.50 17.50 17.00 17.00 17.50 17.50
Btu/hr./Watt
Star rating ** * ** * * * * * *
Power Consumption (V>1=M++ð>) Kw. 0.20 1.50 1.80 0.20 2.30 2.60 0.55 2.45 3.00 0.80 3.20 3.80 0.80 3.20 3.80 0.80 3.60 4.40 0.80 3.60 4.40 0.80 4.70 5.90 0.67 5.93 6.76
Power Supply (/<&&M++ð>) 220V / 1Ph / 50Hz 220V / 1Ph / 50Hz 220V / 1Ph / 50Hz 220V / 1Ph / 50Hz 380V / 3Ph / 50Hz 220V / 1Ph / 50Hz 380V / 3Ph / 50Hz 380V / 3Ph / 50Hz 380V / 3Ph / 50Hz
Operation Current (/<J6M++ð>) Amp. 1.25 6.50 8.40 1.25 9.80 12.10 3.45 11.00 14.50 5.05 15.50 18.80 1.70 4.80 6.25 5.10 16.20 21.00 1.70 5.20 7.20 1.70 7.20 9.50 1.23 9.30 10.90
Indoor Unit Standard air flow rate CMH 1,020 / 850 / 590 1,360 / 1,070 / 730 1,700 / 1,410 / 920 2,040 / 1,530 / 990 2,040 / 1,530 / 990 2,380 / 1,610 / 1,020 2,380 / 1,610 / 1,020 2,720 / 1,230 / 1,650 3,400 / 2,600 / 2,060
('/@->1-7-D%I3A.%) CFM 600 / 500 / 350 800 / 630 / 430 1,000 / 830 / 540 1,200 / 920 / 720 1,200 / 920 / 720 1,400 / 950 / 600 1,400 / 950 / 600 1,600 / 1,230 / 970 2,000 / 1,530 / 1,210
Dimension Outdoor Unit (HxWxD) mm. 630 x 800 x 300 630 x 800 x 300 890 x 900 x 320 890 x 900 x 320 890 x 900 x 320 890 x 900 x 320 890 x 900 x 320 890 x 900 x 320 1,340 x 900 x 320
(%> 9I/CQ9) Indoor Unit (HxWxD) mm. 1,800 x 570 x 330 1,800 x 570 x 330 1,800 x 690 x 330 1,800 x 690 x 330 1,800 x 690 x 330 1,800 x 690 x 330 1,800 x 690 x 330 1,800 x 780 x 390 1,800 x 780 x 390
Net Weight Outdoor Unit kg. 37.0 37.0 59.0 60.0 59.0 62.0 61.0 61.0 83.0
(%RV>7%=I/CQ9) Indoor Unit kg. 55.0 58.0 68.0 69.0 69.0 69.0 69.0 74.0 78.0
Refrigerant Type (%@ 6>/#V>3>-I.P%) R-32 R-32 R-32 R-32 R-32 R-32 R-32 R-32 R-32
Refrigerant Charge ('/@->6>/#V>3>-I.P%) kg. 0.9 1.0 1.2 1.2 1.2 1.4 1.4 1.4 1.5
Compressor Type (%@ 9-I*/6I9/ø) Twin Rotary DC-Inverter Twin Rotary DC-Inverter Twin Rotary DC-Inverter Twin Rotary DC-Inverter Twin Rotary DC-Inverter Twin Rotary DC-Inverter Twin Rotary DC-Inverter Twin Rotary DC-Inverter Twin Rotary DC-Inverter
Expansion Device Valve (%@ 9D'/ø1 J/ =%6>/#V>3>-I.P%) PMV (Pulse Motor Valve) PMV (Pulse Motor Valve) PMV (Pulse Motor Valve) PMV (Pulse Motor Valve) PMV (Pulse Motor Valve) PMV (Pulse Motor Valve) PMV (Pulse Motor Valve) PMV (Pulse Motor Valve) PMV (Pulse Motor Valve)
Connecting Pipe Liquid (#ô96ô) Inch 1/4 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8
(%> #ô9#AQLõ) Suction (#ô9 E ) Inch 1/2 5/8 5/8 5/8 5/8 5/8 5/8 5/8 3/4
Coupler Style Type Flare Flare Flare Flare Flare Flare Flare Flare Flare
Drain O.D. (#ô9%RV>#@R) mm. 26 26 26 26 26 26 26 26 26
Pipe Length Standard (->!/>%>/# 69&) M. 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5
(3>-.>39#ô9) Chargeless Pipe M. 15 (over 15 m, need to extra charge 20 g/m) 15 (over 15 m, need to extra charge 35 g/m)
Minimum Pipe Length M. 3 3 5 5 5 5 5 5 5
Maximum Pipe Length M. 50 50 50 50 50 50 50 50 50
Maximum Pipe Height M. 30 30 30 30 30 30 30 30 30
Capacity Test Condition (6,>3<>/# 69&I/CQ9) Indoor : 27 oCdb, 19oCwb; Outdoor : 35oCdb, 24oCwb
%XLOGLQJ0DQDJHPHQW6\VWHP %06 2SWLRQ
&DUULHUFRQWUROV\VWHPVLQWHJUDWHVWDWHRIWKHDUWZHEWHFKQRORJ\WRGHOLYHUSURGXFWLYLW\FRQQHFWLYLW\DQGHIILFLHQF\
DVZHOODVSURYLGLQJDOOWKHLQWHUIDFHV\RXQHHGWRDFFHVVDQGFRQWURODVLQJOHEXLOGLQJDPXOWLEXLOGLQJFDPSXVRUHYHQ
DJOREDOQHWZRUN
Solution of split type air conditioner 1 : 1 model
LOCAL SUPPLY

Other sytem BN Interface

(IP)

BN Interface
• BACnet®
The BACnet® system operates in conjunction with the BACnet®.
Server uses object signals to provide the following functions:
• Control • Monitoring
– ON/OFF – ON/OFF
– Temperature setting – Operation mode
– Fan speed – Temperature setting
– Room temperature
– Local remote controller : permit / prohibit

LOCAL SUPPLY

Other sytem Modbus Interface

Modbus Interface
The Modbus® interface manages the SMMS-e air conditioning system as a
Modbus® device to communicate with the custormer’s Building Management
System.
Accessible to 64 units / groups per one TCB-IFMB641TLE, 15 TCB-IFMB641TLEs
on one Modbus® Master (prepared by user).
Signals and provides the following functions:
• Control • Monitoring
– ON/OFF – ON/OFF
– Temperature setting – Operation mode
– Fan speed – Temperature setting
– Room temperature
– Local remote controller : permit / prohibit

&/@5=#JI/A./÷Ž'/<I#4M#.?= ©ÇØØÏËØŽºÎÇÏÒÇÔʏ²Úʔ
—ž›ž•œ™“š=R%—š’—› ÚÎ ÚÎ ÕÕؒ
—ž›ž•œ™“š’—š’—›¬Ò
"”I#*/=!%-”š”›J3&>%>L!ô ªËÈÇØÇÚÔǸÕÇʒ±Ó”š”›’¨ÇÔÍÔǺÇϒ
I!&>%>/DI#*;—–˜œ– ¨ÇÔÍÔǨÇÔÍÑÕÑ—–˜œ–ºÎÇÏÒÇÔÊ YOUR CARRIER MAN :
K#/”–“˜–Ÿ–“ŸŸŸŸJ+÷ –“˜›—“šž ºËҔ–“˜–Ÿ–“ŸŸŸŸ¬ÇÞ –“˜›—“šž
Carrier reserves the right to make changes in specifications without prior notice.

40QGV_05/22

You might also like