Professional Documents
Culture Documents
Lanko 764 - Shotcrete PH
Lanko 764 - Shotcrete PH
Description
LANKO 764 Shotcrete PH is a single component, high strength Linear Shrinkage* ASTM C596
cement based repair mortar designed for vertical and overhead Days MPa
application, sea walls, bridge decks, and piers, canals, sewer linings 28 <1.5mm/m
and embankment stabilization.
Uses Packaging
• Wide range application in ground-support application, linings, 25 Kg Bag
and building structures
• Applied as final lining or temporary support during tunneling
• Used for stabilization and protection of earth surface during
embankment stabilization
Storage and Shelf Life
• For swimming pool construction and skate parks Store in a cool, dry place, protected from excessive moisture and
away from direct sunlight. Shelf life of 6 months from date of its
production In its unopened, original packaging.
Advantages
•
•
High Early Strength
High Mechanical Strength
How To Use
• Easy and Fast Application
• Remove loose and damaged concrete and laitance using a
point tool, chisel, or other suitable mechanical tool in order to
Product Use Technical Data obtain a clean, rough surface.
Design Mix: 0.13 to 0.14 water:powder ratio • Clear out concrete from around corroded rebars in order to
create space for removing all existing surface corrosion.
Setting Time* ASTM C191 • The boundaries of the surface to be repaired must be clearly
defined by chiseling or diamond blade grinding to a depth of
Initial: <1.5hrs 10mm minimum.
Final: 1.5hrs to 2hrs
• The substrate must be free of all traces of grease and oil.
Compressive Strength* ASTM C109 Days MPa PSI
Days MPa PSI
1 >30 >4,350
7 >50 >7,250
28 >60 >8,700
¤ ¢
¡
¢
£
¤¤
¤¤
Application
Lanko 764 Shotcrete PH is designed for dry spray shotcreting
applications. This means that water mix ratio is controlled by the
nozzleman. To obtain the highest performance properties,
the water ratio should be kept to a minimum.
Curing
Lanko 764 Shotcrete PH should be protected from moisture
loss during curing stage. This can be achieved with the application
of Lanko 361 Lancure curing compound..
Precautions
• Application temperature from 10°C to 35°C.
• Apply only to clean, sound substrates, free of loose material.
• It is recommended that applicators wear PVC or similar gloves and
safety goggles while handling this product.
• If case of eye contact, rinse with generous amount of cool water.
• In case of ingestion, get immediate medical assistance.
¤ ¢
¡
¢
£
¤¤
¤¤