Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

E2ez Ds csm452

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

Chip-immune Inductive Proximity Sensor

E2EZ CSM_E2EZ_DS_E_4_1

Chip-immune Inductive
Proximity Sensor
• Correct operation even with aluminum or iron chips sticking
to the Sensor.
Only the sensing object is detected.
• Pre-wired Smartclick Connector Models also available.

Be sure to read Safety Precautions on


page 7.

Ordering Information
Sensors [Refer to Dimensions on page 8.]
Pre-wired Models
Model

Appearance Sensing distance Output configuration Operation mode

NO NC

M12 2 mm DC 2-Wire Models E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

DC 3-wire, NPN E2EZ-X4C1 2M —

M18 4 mm DC 2-wire E2EZ-X4D1-N 2M E2EZ-X4D2-N 2M


Shielded
AC 2-wire E2EZ-X4Y1 2M —

DC 3-wire, NPN E2EZ-X8C1 2M —

M30 8 mm DC 2-wire E2EZ-X8D1-N 2M E2EZ-X8D2-N 2M

AC 2-wire E2EZ-X8Y1 2M

Pre-wired Smartclick Connector Models (M12)


Model

Appearance Sensing distance Output configuration Operation mode

NO NC

DC 2-wire, (3)-(4) pin arrangement E2EZ-X2D1-M1TJ 0.3M —


M12 2 mm
DC 2-wire, (1)-(4) pin arrangement E2EZ-X2D1-M1TGJ 0.3M —

Shielded DC 2-wire, (3)-(4) pin arrangement E2EZ-X4D1-M1TJ 0.3M —


M18 4 mm
DC 2-wire, (1)-(4) pin arrangement E2EZ-X4D1-M1TGJ 0.3M —

DC 2-wire, (3)-(4) pin arrangement E2EZ-X8D1-M1TJ 0.3M —


M30 8 mm
DC 2-wire, (1)-(4) pin arrangement E2EZ-X8D1-M1TGJ 0.3M —

1
E2EZ
Pre-wired Connector Models (M12)
Model

Appearance Sensing distance Output configuration Operation mode

NO NC

DC 2-wire, (3)-(4) pin arrangement E2EZ-X2D1-M1J 0.3M —


M12 2 mm
DC 2-wire, (1)-(4) pin arrangement E2EZ-X2D1-M1GJ 0.3M —

Shielded DC 2-wire, (3)-(4) pin arrangement E2EZ-X4D1-M1J 0.3M —


M18 4 mm
DC 2-wire, (1)-(4) pin arrangement E2EZ-X4D1-M1GJ 0.3M —

DC 2-wire, (3)-(4) pin arrangement E2EZ-X8D1-M1J 0.3M —


M30 8 mm
DC 2-wire, (1)-(4) pin arrangement E2EZ-X8D1-M1GJ 0.3M —

Accessories (Order Separately)


Sensor I/O Connectors (M12)
(Models for Pre-wired Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately.) [Refer to Dimensions on XS2, XS5.]
Appearance Cable length Sensor I/O Connector model number Applicable Proximity Sensor model number
Straight 2m XS2F-D421-DD0
5m XS2F-D421-GD0
E2EZ-X@D1-M1J
L-shape 2m XS2F-D422-DD0
5m XS2F-D422-GD0
Straight 2m XS2F-D421-DA0-A
5m XS2F-D421-GA0-A
E2EZ-X@D1-M1GJ
L-shape 2m XS2F-D422-DA0-A
5m XS2F-D422-GA0-A

Smartclick 2m XS5F-D421-D80-A
E2EZ-X@D1-M1TJ
Connector E2EZ-X@D1-M1TGJ
Straight 5m XS5F-D421-G80-A

Mounting Brackets
Protective Covers
Sputter Protective Covers
Refer to Y92@ for details.

2
E2EZ
Ratings and Specifications
Model E2EZ-X2D@-N E2EZ-X4D@-N E2EZ-X8D@-N
E2EZ-X4C1 E2EZ-X8C1
E2EZ-X2D@-M1J E2EZ-X4D@-M1J E2EZ-X8D@-M1J
Item E2EZ-X4Y1 E2EZ-X8Y1
E2EZ-X2D@-M1GJ E2EZ-X4D@-M1GJ E2EZ-X8D@-M1GJ
Sensing distance 2 mm ±10% 4 mm ±10% 8 mm ±10% 4 mm ±10% 8 mm ±10%
Set distance *1 0 to 1.6 mm 0 to 3.2 mm 0 to 6.4 mm 0 to 3.2 mm 0 to 6.4 mm
Differential travel 20% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 4.)
Standard sensing
Iron, 12 × 12 × 1 mm Iron, 30 × 30 × 1 mm Iron, 54 × 54 × 1 mm Iron, 30 × 30 × 1 mm Iron, 54 × 54 × 1 mm
object
Response C Models: 12 Hz C Models: 8 Hz
200 Hz 100 Hz 30 Hz
frequency *2 Y Models: 5 Hz Y Models: 5 Hz
Power supply volt-
C Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p):
age
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. 10% max.
(operating voltage
Y Models: 100 to 220 VAC (90 to 250 VAC), 50/60 Hz
range)
Current
--- C Models: 15 mA max.
consumption
Leakage current 0.8 mA max. Y Models: 2 mA max. at 100 VAC, 3 mA max. at 200 VAC
C Models: NPN open-collector output
Load cur- 100 mA max. at 12 VDC (30 VDC max.)
3 to 100 mA max.
rent 200 mA max. at 24 VDC (30 VDC max.)
Con- Y Models: 10 to 200 mA
trol
output C Models: 2 V max. (Load current: 200 mA, Cable length:
Residual 2 m)
3 V max. (Load current: 100 mA, Cable length: 2 m)
voltage Y Models: Refer to residual voltage characteristic data
Refer to page 4.
D1 Models: Operation indicator (red), Setting indicator (green) C Models: Detection indicator (red)
Indicators
D2 Models: Operation indicator (red) Y Models: Operation indicator (red)
Operation mode D1 Models: NO
NO
(with sensing ob- D2 Models: NC
For details, refer to the Timing chart on page 6.
ject approaching) For details, refer to the Timing chart on page 5.
C Models: Load short-circuit protection, Reverse polarity
Protection
Load short-circuit protection, Surge suppressor protection, Surge suppressor
circuits
Y Models: Surge suppressor
Ambient
temperature range Operating/Storage: 0 to 50°C (with no icing or condensation)

Ambient
humidity range Operating/Storage: 35% to 95% (with no condensation)

Temperature
influence ±20% max. of sensing distance at 23°C in the temperature range of 0 to 50°C

Voltage influence ±2.5% max. of sensing distance at rated voltage in the rated voltage ±10% range
Insulation
50 MΩ min. (at 500 VDC) between current-carrying parts and case
resistance
C Models: 1,000 VAC, 50/60 Hz for 1 min between cur-
rent-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Y Models: 2,000 VAC, 50/60 Hz for 1 min between cur-
rent-carrying parts and case
Vibration
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
resistance
Shock resistance Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of
IEC 60529 IP67, in-house standards: oil-resistant
protection
Connection
Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models
method
E2EZ-X2D@-N: Approx. E2EZ-X4D@-N: Approx. E2EZ-X8D@-N: Approx.
70 g 160 g 220 g
Weight E2EZ-X2D@-M1J: Approx. E2EZ-X4D@-M1J: E2EZ-X8D@-M1J:
Approx. 170 g Approx. 270 g
(packed state) 40 g Approx. 90 g Approx. 160 g
E2EZ-X2D@-M1GJ: E2EZ-X4D@-M1GJ: E2EZ-X8D@-M1GJ:
Approx. 40 g Approx. 90 g Approx. 160 g
Case Nickel-plated brass
Sensing
PBT Heat-resistant ABS
surface
Materi-
als Clamp-
Zinc-plated iron
ing nuts
Toothed
Zinc-plated iron
washer
Accessories Instruction manual
*1. Use the Sensor within the range in which the green indicator is ON.
*2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.

3
E2EZ
Engineering Data (Typical)

Sensing Area
E2EZ-X2@ E2EZ-X4@ E2EZ-X8@

Distance X (mm)
5

Distance X (mm)
10
Distance X (mm)

2.5

2.0 4 8

7
Y Y Y
1.5 3 6
X X X
5

1.0 2 4

0.5 1 2

1
0.0 0 0
−8 −6 −4 −2 0 2 4 6 8 −10 −8 −6 −4 −2 0 2 4 6 8 10 −20 −16 −12 −8 −4 0 4 8 12 16 20
Distance Y Distance Y Distance Y
Sensing Head Sensing Head (mm) Sensing Head
(mm) (mm)

Influence of Sensing Object Size and Material


E2EZ-X2@ E2EZ-X4@ E2EZ-X8@
Distance X (mm)

5 10 10
Distance X (mm)

Distance X (mm)
d× d× d×
d t = 1 mm d d Iron
t = 1 mm t = 1 mm
X X X
4 8 8
Brass

3 6 6
Stainless steel
Iron (SUS304)
Brass Iron Aluminum
Brass
2 4 4
Aluminum
Copper

Aluminum Stainless
1 2 2 steel
Copper (SUS304)
Stainless
steel
(SUS304)
0 10 20 30 40 0 10 20 30 40 50 60 0 10 20 30 40 50 60
Side length of sensing object: d (mm) Side length of sensing object: d (mm) Side length of sensing object: d (mm)

Residual Output Voltage


E2EZ-X@D@-N E2EZ-X4Y1/-X8Y1 at 100 VAC E2EZ-X4Y1/-X8Y1 at 200 VAC
5
Load voltage (V)

Load voltage (V)


Residual output voltage (V)

Residual output Residual output


voltage voltage
4 100 ON 200 ON

3 V
150
V

2 50 100 VAC
A 100
200 VAC
A
1
50
Residual
Residual load load
0 voltage OFF voltage OFF
1 3 5 10 30 50 100 300 500 1,000 0 5 10 50 100 150 200 0 5 10 50 100 150 200
Load current (mA) Load current (mA) Load current (mA)

4
E2EZ

Leakage Current
E2EZ-X4Y1/-X8Y1 E2EZ-X@D@-N
1.5
Leakage current (mA)

Leakage current (mA)


Protective
resistance
6 A
AC power
5
1.0

0.5
2

90 100 150 200 250 0 10 20 30 40


Power supply voltage (V) Power supply voltage (V)

I/O Circuit Diagrams


DC 2-Wire Models
Opera-
tion Model Timing chart Output circuit
mode

Load
Brown +V
Prox-
imity
E2EZ-X2D1-N Sensor
main
E2EZ-X4D1-N circuit
E2EZ-X8D1-N
Blue 0V

Note: The load can be connected to either the


Set position
Non-sensing Unstable +V or 0 V side.
area sensing
area Stable sensing area
(M1J)
Sensing Connector Pin
object 4 Load Arrangement
+V
Prox- 1
(%) 100 80(TYP) 0 imity
NO Rated sensing Sensor 2 4
distance ON Setting indicator main 3
circuit
OFF (green)
E2EZ-X2D1-M1J 3 Note: Pins 1 and 2
ON Operation
E2EZ-X2D1-M1GJ OFF indicator (red)
0V are not used.
E2EZ-X4D1-M1J ON Note: The load can be connected to either the +V or 0 V side.
Control output
E2EZ-X4D1-M1GJ OFF
(M1GJ) Connector Pin
E2EZ-X8D1-M1J
1 Load Arrangement
E2EZ-X8D1-M1GJ +V
Prox- 1
imity 2 4
Sensor
main 3
circuit
4 Note: Pins 2 and 3
0V are not used.
Note: The load can be connected to either the +V or 0 V side.

Non-sensing area Sensing area


Load
Sensing Brown +V
object Prox-
imity
E2EZ-X2D2-N Sensor
main
(%) 100 0
NC E2EZ-X4D2-N Rated sensing circuit

E2EZ-X8D2-N distance
ON Operation Blue 0V
OFF indicator (Red)
ON
Control output
Note: The load can be connected to either the
OFF +V or 0 V side.

5
E2EZ

DC 3-wire Models
Operation
Model Timing chart Output circuit
mode
Brown
+V

Present Load
Sensing object
Not present Proximity
Black *
Sensor
E2EZ-X4C1 Operate main
NO circuit 2.2 Ω Output
E2EZ-X8C1 Load
Reset

ON
Detection indicator (red) Blue
OFF 0V

* 100 mA max. at 12 V, 200 mA max. at 24 V


(load current).

AC 2-Wire Models
Operation
Model Timing chart Output circuit
mode

Brown
Present
Load
Sensing object Prox-
Not present
imity
E2EZ-X4Y1 Operate
Sensor
NO main
E2EZ-X8Y1 Load circuit
Reset Blue
ON
Operation indicator (red)
OFF

Connections for Sensor I/O Connectors


Proximity Sensor Sensor I/O Connectors
Operation Connections
Model Model Model
mode
1: Straight E2EZ XS2F
2: L-shape
DC 2-Wire Models 1 1 Brown (+)
E2EZ-X@D1-M1GJ XS2F-D42@-@A0-A
circuit

2 2
main

(IEC pin wiring) 3 3


D: 2-m cable 4 4 Blue (−)
G: 5-m cable

1: Straight E2EZ XS2F


2: L-shape
DC 2-Wire Models 1 1
(previous pin wir- E2EZ-X@D1-M1J XS2F-D42@-@D0
circuit

2 2
main

ing) 3 3 Blue (−)


D: 2-m cable 4 4 Brown (+)
G: 5-m cable
NO
E2EZ XS5F

DC 2-Wire Models 1 1 Brown (+)


E2EZ-X@D1-M1TGJ White
circuit

2 2
main

(IEC pin wiring) 3 3 Blue


4 4 Black (−)

XS5F-D421-@80-A
E2EZ XS5F
D: 2-m cable
DC 2-Wire Models G: 5-m cable 1 1 Brown
(previous pin wir- E2EZ-X@D1-M1TJ
circuit

2 2 White
main

ing) 3 3 Blue (−)


4 4 Black (+)

Refer to the Sensor I/O Connector Group Catalog (Cat. No. X073) for details.

6
E2EZ
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for ensuring Aluminum and Iron Cuttings
safety of persons either directly or indirectly. Normally aluminum or iron cuttings will not be detected even if they
Do not use it for such purposes. adhere to or accumulate on the sensing surface.
Detection signals may be output for the following:
If this occurs, remove the cuttings from the sensing surface.
Precautions for Correct Use 1. Relationship between the Size of the Cutting (d) and the Size of
Do not use this product under ambient conditions that exceed the the Sensing Surface (D)
ratings. 2
Cuttings of the size d ≥ 3 D on the sensing surface *

● Design Cuttings of the size d* (Unit: mm)


d
Influence of Surrounding Metal Model Size D Cutting
When mounting the Sensor within a metal panel, ensure that the E2EZ-X2@ 10 *
clearances given in the following table are maintained. Failure to D Sensing
maintain these distances may cause deterioration in the performance E2EZ-X4@ 16 surface

of the Sensor. E2EZ-X8@ 28


1
* E2EZ-X2@: d ≥ 3 D on the sensing surface.
m
2. Cuttings Pressed against the Sensing
d dia. n
Surface Pressed against
D sensing surface.
Cutting
l
Influence of Surrounding Metal (Unit: mm)
Item
Embedded l d D m n
Model material
Iron 0 12 0 18
E2EZ-X2@ 8 ● Mounting
Aluminum 2 25 2 36
Do not tighten the nut with excessive force.
Iron 0 18 0 27
E2EZ-X4@ 16 A washer must be used with the nut.
Aluminum 5 40 5 54
Iron 0 30 0 45
E2EZ-X8@ 32
Aluminum 10 70 10 90

Mutual Interference
Part B Part A
When installing Sensors face-to-face or side-by-side, ensure that the Note: 1. The allowable tightening strength depends on the distance from the
minimum distances given in the following table are maintained. edge of the head, as shown in the following table. (A is the distance
from the edge of the head. B includes the nut on the head side. If the
Mutual Interference (Unit: mm) edge of the nut is in part A, the tightening torque for part A applies
instead.)
Model Item A B 2. The following torque assume washers are being used.
A
E2EZ-X2@ 30 20 Tightening
Part A Part B
E2EZ-X4@ 40 50 Torque
B
E2EZ-X8@ 60 100 Dimension
Torque Torque
Model (mm)
E2EZ-X2D@-@ 30 N·m
E2EZ-X4D@-@ 70 N·m
E2EZ-X8D@-@ 180 N·m
E2EZ-X4C1
20 15 N·m 29 N·m
E2EZ-X4Y1
E2EZ-X8C1
22 29 N·m 39 N·m
E2EZ-X8Y1

7
E2EZ
(Unit: mm)
Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.

E2EZ-X2D@-N 38 9 Pre-wired Connector Models (-M1J/M1GJ)


21 dia.
33
17 4 10
M12 × 1

15 dia.
*1
*2
Indicator 4-dia. vinyl-insulated round cable with
M12 × 1 2 conductors (Conductor cross
Two clamping nuts
Toothed washer section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 300 mm
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2,
Insulator diameter: 1.3 mm), Standard length: 2 m
*2. D1 Models: Operation indicator (red), Setting indicator (green), D2 Models: Operation
indicator (red)

E2EZ-X4D@-N E2EZ-X8D@-N
48 12
43 12 42 dia.
43
29 dia.
38 36 5 10
24 4 10

*1 *1
Indicator*2 *1. 6-dia. vinyl-insulated round cable with 22 conduc- Indicator*2
M18 × 1 tors (Conductor cross section: 0.5 mm , Insula-
Two clamping nuts tor diameter: 1.9 mm), Standard length: 2 m *1. 6-dia. vinyl-insulated round cable with 2 con-
Toothed washer The cable can be extended up to 200 m (sepa- ductors (Conductor cross section: 0.5 mm2, In-
M30 × 1.5 Two clamping nuts sulator diameter: 1.9 mm), Standard length: 2 m
rate metal conduit).
*2. D1 Models: Operation indicator (red), Setting in- Toothed washer The cable can be extended up to 200 m (sepa-
dicator (green) rate metal conduit).
D2 Models: Operation indicator (red) *2. D1 Models: Operation indicator (red), Setting
indicator (green)
D2 Models: Operation indicator (red)

Pre-wired Connector Models (-M1J/M1GJ) Pre-wired Connector Models (-M1J/M1GJ)


M12 × 1 M12 × 1

15 dia. 15 dia.

6-dia. vinyl-insulated round cable with 6-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section: 2 conductors (Conductor cross section:
0.5 mm2, Insulator diameter: 1.9 mm), 0.5 mm2, Insulator diameter: 1.9 mm),
Standard length: 300 mm Standard length: 300 mm

E2EZ-X4C1 29 dia.
80
E2EZ-X4Y1 24 60

Indicator*2

*1
M18 × 1
4 4
Two toothed washers Two clamping nuts
*1. C Models: 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross *2. C Models: Detection indicator (red),
section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m Y Models: Operation indicator (red)
Y Models: 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross
section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m

E2EZ-X8C1 42 dia.
80
E2EZ-X8Y1 36 60

Indicator*2

*1
M30 × 1.5
5 5
Two toothed washers Two clamping nuts

*1. C Models: 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross *2. C Models: Detection indicator (red),
section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m Y Models: Operation indicator (red)
Y Models: 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross
section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m

Mounting Hole Dimensions

Model F (mm)
+0.5
E2EZ-X2@ 12.5 dia. −0
+0.5
E2EZ-X4@ 18.5 dia. −0

F
E2EZ-X8@ 30.5 dia. +0.5
−0

8
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.

Warranty and Limitations of Liability

WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR


FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

Application Considerations

SUITABILITY FOR USE


OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.

• Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

Disclaimers

CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS


Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.

ERRORS AND OMISSIONS


The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

2010.8
In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2010 All Right Reserved.

You might also like