RELIEF VALVE

(Direct Acting, Poppet)


Ordering Code: RD-162A-X-Y-Z

4.0 Hex. Control Option:


Maximum extension
Turn screw clockwise from locating shoulder.
to increase pressure (Z=L Control shown) 1 2
setting.

5/16"-32UNEF-2A
12.7 Hex. (1/2 inch)
Torque 9 - 10 Nm

16.6
54
TECHNICAL DATA
19.05 Hex.
(3/4 inch) Max. Operating pressure: 350 bar

Locating Rated flow: 45 l/min


Shoulder
Cavity-Tooling: 162A-2
6.6
30.96 (Ref.)

M16x1.5
Installation torque: 27 - 33 Nm
Outlet 2
Weight: 0.10 (Z=L,LP) 0.12 (Z=K) kg
Will accept maximum pressure at port 2 ;
Inlet 1 suitable for use in cross port relief circuits.

Illustrations / detail are


for reference only.
UNIT:mm Data subject to change.

Typical Pressure Rise X OPERATION


350
Direct Acting
Pressure- P(bar)

300
25 1 to 2 (P to T)
250
200 .Response Time-Typical (2 ms)
150 .Maximum Leakage Approximately
( 5 drops/min. to 85% of nominal setting)
100
.Dirt tolerant
50

0 10 20 30 40 50
Flow-Q(l/min)

Y PRESSURE SETTING Z OPTIONS

A 35 - 210 bar (70 bar Standard Setting) Leakproof hex.


L socket screw.
B 20 - 105 bar (70 bar Standard Setting)

C 70 - 420 bar (70 bar Standard Setting) Leakproof hex.


D 14 - 55 bar (28 bar Standard Setting) LP socket screw.
With stainless steel
external metal components
E 10 - 28 bar (14 bar Standard Setting)
Handknob with
S 3.5 - 14 bar (7 bar Standard Setting)
K Lock Knob.
(Order Code: 7ZAK001)
W 55 - 315 bar (70 bar Standard Setting)
Rev.221124 B.102.200.E