TROUBLESHOOTING (Z3: ZERO POINT ADJUSTMENT)

I74653A04E

TROUBLESHOOTING
(Z3: ZERO POINT ADJUSTMENT)

<Machine Models>
Machines equipped with Mitsubishi NC

<NC>
MSG-803
MSG-805

TITLE
A04E 02.11.11 T. KURAMOTO TROUBLESHOOTING
A03E 01.08.02 S. OKUBO (Z3: ZERO POINT
A02E 99.09.07 ADJUSTMENT)
T. KURAMOTO
A01E 99.04.01 H. SARATANI DRAWING No.
EDITION DATE DRAWN I74653A04E

Z3 (1/11)
TROUBLESHOOTING (Z3: ZERO POINT ADJUSTMENT)
I74653A04E

Revision Record
Version Person in
Date Change Remark
No. Charge

A01E 99.04.01 H. SARATANI New Design


Correcting the setting procedure
A02E 99.09.07 T. KURAMOTO
of parameter
(conversational programming
side, X-axis reversed JIS
specification)
Making compatible to the
A03E 01.08.02 S. OKUBO
SL-154 and SL-204 series
Machine name has been
A04E 02.11.11 T.KURAMOTO
changed for Mitsubishi NC

Z3 (2/11)
TROUBLESHOOTING (Z3: ZERO POINT ADJUSTMENT)
I74653A04E

Z3: ZERO POINT ADJUSTMENT

This section deals with corrective actions to take when trouble related to the screen
occurs. According to the nature of the trouble encountered, refer to the section
indicated below to find the corrective action to take.

Classification of Corrective Actions


Item Corrective Actions
Z3 - 1 Zero point establishing and changing methods
Z3 - 2 Changes to the reversed JIS specifications
Z3 - 3 Changes to the JIS specifications
Z3 - 4
Z3 - 5
Z3 - 6
Z3 - 7
Z3 - 8
Z3 - 9
Z3 - 10
Z3 - 11
Z3 - 12
Z3 - 13
Z3 - 14
Z3 - 15
Z3 - 16
Z3 - 17
Z3 - 18
Z3 - 19
Z3 - 20
Z3 - 21
Z3 - 22
Z3 - 23
Z3 - 24
Z3 - 25

Z3 (3/11)
TROUBLESHOOTING (Z3: ZERO POINT ADJUSTMENT)
I74653A04E

Z3 - 1. ZERO POINT ESTABLISHING AND CHANGING METHODS

The zero point establishing and changing methods are described below using the X-
axis as an example.

1) Press the function selection key [MESSAGE] to display the NC ALARM screen
and check if "Z70 ABS. POSI. ERR" is displayed on the screen.
- Yes → Press the function selection key [SETTING] and the [F1] (OPE.
PANEL) soft-key in order and set "VALID" for the item ZERO
POSITION SET.
- No → END

2) For which axis are you going to adjust the zero point?
- Milling axis → To 3)
- Turret axis (SL-154, 204) → To 4)
- Other axis → To 5)

3) Select the on-site adjustment mode*.


Change the setting of parameter to "#6437.4 = 1" and select "M" axis for the
pulse handle operation target axis.
* While pressing the FEED HOLD button, turn the PANEL key-switch in the
following positions in order: "ON" → "OFF" → "ON".
Make sure that the FEED HOLD lamp is blinking

4) Select the on-site adjustment mode*.


Change the setting of parameter to "#6437.0 = 1" and select "T" axis for the
pulse handle operation target axis.
After that, press the turret station setting switch (increase) to unclamp the
turret.
* While pressing the FEED HOLD button, turn the PANEL key-switch in the
following positions in order: "ON" → "OFF" → "ON".
Make sure that the FEED HOLD lamp is blinking

5) Press the function selection key [SYSTEM].

6) Press the [F3] (NC SYSTEM) soft-key.

7) Press the keys: [2] (DGN, MESSAGE) [INPUT].

8) Press the [F5] (MENU) soft-key.

Z3 (4/11)
TROUBLESHOOTING (Z3: ZERO POINT ADJUSTMENT)
I74653A04E

9) Press the [F1] (ABS-SRV) soft-key. Check if pressing the page selection key
[ ▼ ] (advance) once displays the screen shown below.

NOTE: If the zero point is established at this time, "OK" is displayed to the
right of STATE. Otherwise, "NG" is displayed.

10) Key in # (0) ( 1) using the data entry keys.


(NOTE: For the Z-axis, key in # (0) ( ) ( 1).)
Check if "ORIGIN SET" and "INITIAL SET (ABS.)" are displayed to the right of
STATE and at the lower left area on the screen, respectively.

Z3 (5/11)
TROUBLESHOOTING (Z3: ZERO POINT ADJUSTMENT)
I74653A04E

11) Move the X-axis (or the Z-axis) to the zero point using the manual pulse
generator.
For the milling axis, look at the rotating section through the milling tool holder
mounting hole in the turret and align the groove in the turret and that in the
rotating section.

12) Key in # (1) ( 1) using the data entry keys.


(NOTE: For the Z-axis, key in # (1) ( ) ( 1).)
Check if "ORIGIN SET" displayed to the right of STATE changes to "ORIG-
RTN".

13) Feed the X-axis (or the Z-axis) in the negative direction using the manual pulse
generator. (Feed the X-axis in the positive direction for the X-axis reversed JIS
specifications.)
NOTE: The axis automatically stops at the next grid. If the axis fails to stop
at the next grid after fed over 30 mm, the procedure may not have been
followed correctly. Check the procedure described above again and
follow the procedure correctly.

14) Check if "ORIGIN SET" displayed to the right of STATE changes to "OK".

Z3 (6/11)
TROUBLESHOOTING (Z3: ZERO POINT ADJUSTMENT)
I74653A04E

15) Switch on the power again and execute the zero return once to check if the zero
point is correct.

- Yes → END
- No → Adjust the zero point again.

Z3 (7/11)
TROUBLESHOOTING (Z3: ZERO POINT ADJUSTMENT)
I74653A04E

Z3 - 2. CHANGES TO THE REVERSED JIS SPECIFICATIONS

1) After switching on the power and executing the zero return, press the following
keys in order:
Function selection key [SYSTEM], [F3] (NC SYSTEM) soft-key,
[2] (DGN, MESSAGE) key, [INPUT] key, [F5] (MENU) soft-key

2) After pressing the [F2] (SERVO) soft-key, press the page selection key [ ▼ ]
(advance) once, and record the value of CYC CNT (p) on the SERVO MONITOR
(2) screen.

3) Change the settings of the parameters as follows.


Please assume ⃝⃝⃝, ●●●, △△△, ▲▲▲, □□□, and ■■■ to be set
values (absolute values).

Set Value Set Value


Parameter #
Before Change After Change
#1018: X 1 0
#1066: X 0627 0628
#1067: X 0628 0627
#2013: X − ⃝⃝⃝ − ●●●
#2014: X ●●● ⃝⃝⃝
#2050: X 1 0
#2061: X − △△△ − ▲▲▲
#2062: X ▲▲▲ △△△
#6401.2 0 1
#8204: X − □□□ − ■■■
#8205: X ■■■ □□□
#1191 60.000 -60.000
#6315 ☆☆☆ -☆☆☆ Only for Y-axis
specification and
#6316 -★★★ ★★★ SY type: SL2500Y, SY

4) Switch off the power once and switch it on again.

5) Perform the operations described in 1) to 13) in Z3 - 1, "ZERO POINT


ESTABLISHING AND CHANGING METHODS".
NOTE: After visually checking the X-axis zero-point mark, display the SERVO
MONITOR (2) screen (described in 2)), and turn the manual pulse
generator so that the value of CYC CNT will correspond to the value
that was recorded in step 2).

Z3 (8/11)
TROUBLESHOOTING (Z3: ZERO POINT ADJUSTMENT)
I74653A04E

6) After pressing the function selection key [SYSTEM], press the [F2] (CAP
PARAM.) soft-key to display the CAP PARAMETER screen.

7) At the SETTING screen, set the parameter as "CAP PARAMETER WRITE = 1


(VALID)", input "1" for CAP parameter No. 66 to enable writing of the
parameter, and then press the [F9] (DATA SET) soft-key.

8) Switch off the power once and switch it on again.

9) Check the operation in both the manual mode and the automatic mode.
The operation now ends.

Z3 (9/11)
TROUBLESHOOTING (Z3: ZERO POINT ADJUSTMENT)
I74653A04E

Z3 - 3. CHANGES TO THE JIS SPECIFICATIONS

1) After switching on the power and executing the zero return, press the following
keys in order:
Function selection key [SYSTEM], [F3] (NC SYSTEM) soft-key,
[2] (DGN, MESSAGE) key, [INPUT] key, [F5] (MENU) soft-key

2) After pressing the [F2] (SERVO) soft-key, press the page selection key [ ▼ ]
(advance) once, and record the value of CYC CNT (p) on the SERVO MONITOR
(2) screen.

3) Change the settings of the parameters as follows.


Please assume ⃝⃝⃝, ●●●, △△△, ▲▲▲, □□□, and ■■■ to be set
values (absolute values).

Set Value Set Value


Parameter #
Before Change After Change
#1018: X 0 1
#1066: X 0628 0627
#1067: X 0627 0628
#2013: X − ⃝⃝⃝ − ●●●
#2014: X ●●● ⃝⃝⃝
#2050: X 0 1
#2061: X − △△△ − ▲▲▲
#2062: X ▲▲▲ △△△
#6401.2 1 0
#8204: X − □□□ − ■■■
#8205: X ■■■ □□□
#1191 -60.000 60.000
#6315 -☆☆☆ ☆☆☆ Only for Y-axis
specification and
#6316 ★★★ -★★★ SY type: SL2500Y, SY

4) Switch off the power once and switch it on again.

5) Perform the operations described in 1) to 13) in Z3 - 1, "ZERO POINT


ESTABLISHING AND CHANGING METHODS".
NOTE: After visually aligning the X-axis zero point marks with each other,
display the SERVO MONITOR seen (described in step 2)) and turn the
manual pulse generator so that the value of CYC CNT will correspond
to the value that was recorded in step 2). This sets the X-axis almost
at the zero point.

Z3 (10/11)
TROUBLESHOOTING (Z3: ZERO POINT ADJUSTMENT)
I74653A04E

6) After pressing the function selection key [SYSTEM], press the [F2] (CAP
PARAM.) soft-key to display the CAP PARAMETER screen.

7) At the SETTING screen, set the parameter as "CAP PARAMETER WRITE = 1


(VALID)", input "0" for CAP parameter No. 66 to enable writing of the
parameter, and then press the [F9] (DATA SET) soft-key.

8) Switch off the power once and switch it on again.

9) Check the operation in both the manual mode and the automatic mode.
The operation now ends.

Z3 (11/11)