Contents
2 Overview ........................................................................................................................................ 5
3. Installation ..................................................................................................................................... 6
4. System description (Standard solar system with 1 tank, 1 collector field) ........................................ 9
1
Manual of SR208C intelligent controller
7.4 PUMP Pump control mode ......................................................................................................... 22
10. Accessories................................................................................................................................ 33
2
Manual of SR208C intelligent controller
1. Safety information
3
Manual of SR208C intelligent controller
and ideas, however inevitable errors maybe exist. Please note that we cannot guarantee that this
manual is given in the integrity of image and text, incorrect, incomplete and erroneous information and
the resulting damage we do not take responsibility.
Safety indication: Safety instructions in the text are marked with a warning triangle. They
indicate measures which can lead to injury of person or safety risks.
Operation steps: small triangle “►”is used to indicate operation step.
Notes: Contains important information about operation or functions.
Controller is operated with the 6 buttons on the right side of the screen
“ " holiday button
“M.H” button: manual heating
“SET” button: confirm / selection
“▲” up button: increase the value
“▼” down button: reduce the value
“ESC" button return/ exit : return to previous menu
4
Manual of SR208C intelligent controller
2. Overview
5
Manual of SR208C intelligent controller
3. Installation
Note: The unit must only be located in the dry interior rooms. Please separate routing of
sensor wires and mains wires. Make sure the controller as well as the system is not exposed to strong
electromagnetic fields.
6
Manual of SR208C intelligent controller
Note: before opening the housing! Always disconnect the controller from power supply and
obey the local electrical supply regulation.
Input ports
T1: PT1000 temperature sensor, for measuring the temperature of collector and thermal energy
calculation.
T2 ~T3: NTC10K, B=3950 temperature sensor, for measuring temperature of tank and pipe.
Communication port 485 (selectable) : ELA485, for remote control communication (The
Communication port not in the standard configuration;WIFI model should be purchased
separately, detailed see annexed part)
PWM: Signal ports for high efficiency pump, detailed connection see below
7
Manual of SR208C intelligent controller
transformer substations, radio and television devices, amateur radio stations, microwave devices
etc., then the cables to the sensors must be adequately shielded.
Sensor cables may be extended to a maximum length of ca. 100 meter, when cable’s length is up
2
to 50m, and then 0.75mm cable should be used. When cable’s length is up to 100m, and then
2
1.5mm cables should be used.
Output ports
Input Ports L, N: for power connection, L: live wire, N: zero wire, protective wire
Output R1: Semiconductor relays (SCR), designed for pump speed control, Max. Current: 1A
Output HR: Electromagnetic relays, designed for on/off control of afterheating/thermostat function, Max.
Current: 2A
Signal wire 1 from the high-efficiency pump is connected to GND port of controller
Signal wire 2 from the high-efficiency pump is connected to PWM port of controller
Signal wire 3 from the high-efficiency pump is not connected to the controller
Note: High-efficiency pump with 0-10V signal only has 2 signal wires, connected to the
corresponding port GND, PWM of controller.
8
Manual of SR208C intelligent controller
4. System description (Standard solar system with 1 tank, 1 collector field)
Description:
The controller calculates the temperature difference between collector sensor T1 and tank sensor T2. If
the difference is larger than or identical to the adjusted switch-on temperature difference, the solar
circulation pump (R1) will be switched on and the tank will be loaded until the switch-off temperature
difference or the maximum tank temperature is reached.
9
Manual of SR208C intelligent controller
5. Function’s parameters and options
Access submenu
►After selecting main menu, then press “SET” button to access submenu
►Press “▲/▼” button to select submenu,
►Press “SET” button to enter the value adjust interface or selection function( select ON/OFF)
►Press “▲/▼” to adjust value
►Press “SET” to confirm the value you set
10
Manual of SR208C intelligent controller
Note: Enter the menu adjustment interface, if you don’t press any button within 3 minutes, screen
will exit the adjustment and turn to main interface.
Menu structure
11
Manual of SR208C intelligent controller
thermostat function for using surplus energy
Note: If customer use electrical heater as back-up, please according to the power of electrical
heater to equip corresponding safety devices like contactor and breaker with this controller, we strongly
recommend equipping with SR802 device with this controller, (SR802 detailed technical data see spare
parts)
Menu structure
12
Manual of SR208C intelligent controller
Switch-on temperature of
AHO 40oC 0.5oC
after heating
Switch-off temperature of
AHF 45oC 0.5oC
after heating
Switch-on time of the first
tA 1O 00:00 00:00-23:59
after heating
Switch-off time of the first
tA 1F 23:59 00:00-23:59
after heating
Switch-on time of the second
t A2O 00:00 00:00-23:59
after heating
Function setting:
►Press “SET” button to access main menu, and press “▲” to select AH Afterheating/thermostat main
menu.
►Press “SET” button to set parameter, “AHS S3” displays on the screen.
►Press “SET” button, “S3” blinks
►Press “▲/▼” button to select desired sensor (S3 for T3, S2 for T2)
►Press “SET” or “ESC” button to save the setting.
► Press “▲” button, “AHO 40oC” displays on the screen
►Press “SET” button, “40oC” blinks
►Press “▲/▼” button to adjust the switch-on temperature.
► Press “SET” or “ESC” button to save the setting.
► Press “▲” button, “AHF 45oC” displays on the screen
► Press “SET” button, hour time “45oC” blinks
► Press “▲/▼” button to adjust hour of the switch-off temperature.
► Press “SET” or “ESC” button to save the setting.
► Press “▲” button “tA1O 00:00” displays on the screen
► Press “SET” button, hour time “00” blinks
► Press “▲/▼” button to adjust hour of the switch-on time
► Press “SET” button, minute time “00” blinks
► Press “▲/▼” button to adjust minute of the switch-on time
► Press “SET” or “ESC” button to save the setting.
► Press “▲” button, “tA1F 23:59” displays on the screen
► Press “SET” button, hour time “23” blinks
► Press “▲/▼” button to adjust hour of the switch-off time
13
Manual of SR208C intelligent controller
► Press “SET” button, minute time “59” blinks
► Press “▲/▼” button to adjust minute of the switch-off time
► Press “SET” or “ESC” button to save the setting.
► Press “▲” button to access the window of the switch-on time of the second afterheating/thermostat,
repeat above steps to set time for the second and third afterheating/thermostat.
If you want to shut of one time of afterheating/thermostat,you can set switch on and off at the same
value.(For example,the second time section no this function,then you can set tA2O 00:00 and tA2F
00:00)
When heating sign blinks on the screen, it indicates that after-heating function is activated.
Note:
The Sign" " represents After-heating
1. Within the preset time section, heating sign is lighted on the screen
2. Out of the preset time section, heating sign doesn’t display on the screen.
7.1PWD Password
Menu structure
14
Manual of SR208C intelligent controller
►Press “▲/▼” to enter the second digital
►Press” SET”, the third digital blinks
►Press”▲/▼” to enter the third digital
►Press “SET”, the forth digital blinks
►Press “▲/▼” to enter the forth digital
►Press “SET”, to access main menu
Through password set to limit the user to change some parameters, 4 digitals needed. Default is 0000
If no password is set, then just press “SET” five times to access main menu directly
Note: The switch-on temperature difference must be 0.5 K higher than the switch-off
temperature difference. The set temperature difference must be at least 0.5 K higher than the
switch-on temperature difference.
Speed control
If the temperature reaches or exceeds the switch-on temperature difference, the pump switches on at
100% speed for 10s. Then, the speed is reduced to the minimum pump speed value.
If the temperature difference reaches the preset temperature difference, the pump speed increases by
one step (10%). The response of the controller can be adapted via the parameter RIS. If the difference
increases by the adjustable rise value RIS, the pump speed increases by 10% until the maximum pump
speed of 100% is reached. If the temperature difference decreases by the adjustable rise value (RIS),
pump speed will be decreased by one step 10% accordingly.
Note: To enable speed control function, the corresponding pump has to be set to (MIN, MAX)
and relay control has to be set to (PULS, PSOL, PHEA or 0-10 V) (under adjustment menu
PUMP).
15
Manual of SR208C intelligent controller
The sensor for tank maximum limitation (SMAX) can be selected. The maximum limitation always
o
refers to the sensor selected (T2 or T3). The switch-on hysteresis (HYST) is selectable(Default is 2 C),
o o
for example, when tank maximum temperature is set to 70 C , then at 68 C, Maximum tank
temperature protection function is deactivated automatically.
Menu Structure
16
Manual of SR208C intelligent controller
circuit pump
► Press “SET” or “ESC” to save the setting
► Press “▲”, “DTF 4K” displays on the screen
► Press “SET”, “4K” blinks
► Press “▲/▼”, to adjust the switch-off temperature of solar circuit pump
► Press “SET” or “ESC” to save the setting
► Press “▲”, “DTS 10K” displays on the screen
► Press “SET”, “10K” blinks
► Press “▲/▼”, to adjust the standard temperature difference of solar circuit pump
► Press “SET” or “ESC” to save the setting
► Press “▲”, “RIS 2K” displays on the screen
► Press “SET”, “2K” blinks
► Press “▲/▼”, to adjust the rise range of pump speed control
► Press “SET” or “ESC” to save the setting
o
► Press “▲”, “SMX 70 C” displays on the screen
o
► Press “SET”, “70 C” blinks
► Press “▲/▼”, to adjust the maximum temperature of tank
► Press “SET” or “ESC” to save the setting
► Press “▲”, “SMAX S3” displays on the screen
► Press “SET”, “S3” blinks
► Press “▲/▼”, select the sensor for maximum temperature of tank (S3 for T3, S2 for T2)
► Press “SET” or “ESC” to save the setting
► Press “▲”, “HYST 2K” displays on the screen
► Press “SET”, “2K” blinks
► Press “▲/▼”, to adjust the hysteresis of tank maximum temperature
► Press “SET” or “ESC” to save the setting
Warning! Risk of injury! Risk of system damage by pressure surge! If water is used as the heat
transfer fluid in pressure systems, water will boil at 100 °C. Then do not set the collector limit
temperature higher than 95 °C.
17
Manual of SR208C intelligent controller
OCCO Collector cooling
The collector cooling function keeps the collector temperature rising within the operating range by
heating the tank. If the tank temperature reaches 95°C the function will be switched off for safety
reasons.
When the tank temperature exceeds the adjusted maximum temperature of tank, then solar system is
switched off. If the collector temperature rises up to its adjusted maximum collector temperature, the
solar pump is switched on again until the collector temperature falls below the maximum collector
temperature. The tank temperature may then exceed its maximum temperature, but only up to 95°C
(emergency shutdown of the tank), and sign blinks on the screen, system stops.
If the collector cooling is active, blinks on the screen.
This function is only available when the system cooling function (OSYC) and the heat transfer function
(OHDP) are not activated.
This function operates within an adjusted time section. It activates the collector circuit pump R1 for an
adjustable runtime between adjustable pauses in order to compensate for the delayed temperature
measurement.
18
Manual of SR208C intelligent controller
If the runtime is set to more than 10s, the pump will run at 100% for the first 10s of the runtime. For the
remaining runtime, the pump will run at the adjusted minimum speed.
If the collector sensor is defective or the collector is blocked, this function will be switched off.
Menu structure
19
Manual of SR208C intelligent controller
o o o
CFRO 4C -40-8 C 0.5 C Switch-on temperature of
anti-freeze function
o o o
CFRF 5C -39-9 C 0.5 C Switch-off temperature of
anti-freeze function
Function setting:
OCEM (Collector emergency shutdown function) setup
►Select “COL” function menu
►Press “SET”, “OCEM” displays on the screen
►Press “SET” again, “OCEM ON” displays on the screen
►Press “SET”, “ON” blinks on the screen
(If it is necessary to shut down this function, press “▲/▼” to deactivate it)
►Press “SET” or “ESC” to save the setting
o
►Press “▲”, “OCEM 130 C” displays on the screen
o
►Press “SET”, “130 C” blinks on the screen
►Press “▲/▼”, to activate or deactivate the collector emergency function
►Press “SET” or “ESC” to save the setting
►Press “ESC” to return to previous menu
20
Manual of SR208C intelligent controller
OCMI (Collector minimum temperature) setup
►Press “▲”, “OCMI” displays on the screen
►Press “SET”, “OCMI OFF” displays on the screen
►Press “SET”, “OFF” blinks on the screen
►Press “▲/▼”, to activate this function, “OCMI ON” displays on the screen
o
►Press “▲”, “OCMI 10 C” displays on the screen
►Press “▲/▼”, to adjust the minimum temperature of collector
►Press “SET” or “ESC” to save the setting
►Press “ESC” to return to previous menu
21
Manual of SR208C intelligent controller
►Press “SET”, “00” blinks
►Press “▲/▼”, to adjust minute
►Press “SET” or “ESC” to save the setting
►Press “▲”, “TCRU 30” displays on the screen
►Press “SET”, “30” blinks
►Press “▲/▼”, to adjust runtime
►Press “SET” or “ESC” to save the setting
►Press “▲”, “TCIN 30Min” displays on the screen
►Press “SET”, “30” blinks
►Press “▲/▼”, to adjust stop time
►Press “SET” or “ESC” to save the setting
►Press “ESC” to return to previous menu
Note:
1. More information about connection of high efficiency pump see the paragraph (3.5 Connection
with high efficiency pump)
2. Minimum pump speed: Under the adjustment menu MIN1 , a relative minimum speed for
connected pumps can be allocated to the outputs R1.
3. Maximum pump speed: Under the adjustment menu MAX1, a relative maximum speed for
connected pumps can be allocated to the outputs R1.
4. When the devices which are not speed-controlled are used (e. g. motored valves), the pump speed
value of the corresponding relay must be set to 100 % or the control Mode must be set to ONOF in
order to deactivate pump speed control.
22
Manual of SR208C intelligent controller
Main Submenu Submenu Factory Adjustable Step Description
menu 1 2 set range per
adjust
PUMP Pump control mode
ONOF ON ON/OFF Pump on/off (for pump
without speed adjustment
function)
PULS OFF ON/OFF Pulse control (Burst control
via semiconductor relay
MIN1 30% 20-95% 5%
MAX1 100% 25-100% 5%
Function setup
►Select “PUMP” menu
►Press “SET”, “ONOF ON” displays on the screen
►Press “▲/▼”, to select pump type “PLUS、PSOL、PHEA、0-10V”
►After select pump type, press “SET” to access the pump type.
►Press “SET”, “OFF” blinks on the screen
►Press “▲/▼” to open
►Press “SET” or “ESC” to save the setting
►Press “ESC” to return to previous menu
Note:
Only 1 type can be selected from 5 types ONOF、PLUS、PSOL、PHEA、0-10V
Example: when “PLUS ON” open option is selected, then other four types are closed automatically.
23
Manual of SR208C intelligent controller
Note: This function will only be available when the collector cooling function, external radiator
heat transfer functions are not activated.
o
Note: if tank temperature reaches to 95 C, all cooling functions will be locked.
Hysteresis switch on temperature difference is 5K.
Menu structure
24
Manual of SR208C intelligent controller
OSTC OFF ON/OFF Tank cooling function
DTCO 20K 1-30K 0.5K Switch-on temperature
difference of cooling
function
DTCF 15K 0.5-29.5K 0.5K Switch-off temperature
difference of cooling
function
Function setting:
OSYC (system cooling function) setting
►Select “COOL” menu
►Press “SET”, “OSYC OFF” displays on the screen
►Press “SET”, “OFF” blinks on the screen
►Press “▲/▼”, to activate this function
►Press “SET” or “ESC” to save the setting
Note: When manual mode is activated, sign blinks on the screen, controller runs for 15
minutes and then switch-off all output, control exits manual mode automatically.
25
Manual of SR208C intelligent controller
Menu structure
Function setup
►Press “▲”, “R1” displays on the screen
►Press “SET”, “R1 OFF” displays
►Press “SET”, “OFF” blinks
►Press “▲/▼”, to activate this function, “R1 ON” displays
►Press “SET” or “ESC” to save the setting
►Press “▲”, “HR” displays, repeat above steps to set the manual output of HR.
Menu structure
Function setting
►Press”▲”, “BLPR” displays on the screen
►Press “SET”, “BLPR OFF” displays
►Press “SET”, “OFF” blinks
►Press “▲/▼”, to activate this function, “BLPR ON” displays on the screen
26
Manual of SR208C intelligent controller
►Press “SET” or “ESC” to save the setting
For thermal disinfection, the temperature at the allocated sensor has to be monitored. During the
monitoring period PDIS, this protection ensures the disinfection temperature is continuously exceeded
the disinfection temperature TDIS for the entire disinfection period DDIS. Thermal disinfection can only
be completed when the disinfection temperature is exceeded for the duration of the disinfection period
without any interruption.
The monitoring period PDIS starts as soon as the temperature at the allocated sensor falls below the
disinfection temperature TDIS, once the monitoring period PDIS ends, disinfection period SDIS starts,
and the allocated reference relay activates the after-heating, when tank temperature exceeds the
disinfection temperature, disinfection phase DDIS starts and disinfection heating time countdowns,
countdown finishes, disinfection heating finishes.
Menu structure
Function setting
►Press “▲”, “OTDI” displays on the screen
►Press “SET”, “OTDI OFF” display
►Press “SET”, “OFF” blinks
►Press “▲/▼”, to activate this function, “OTDI ON” displays
27
Manual of SR208C intelligent controller
►Press “SET” or “ESC” to save the setting
►Press “▲”, “PDIS 7” displays
►Press “SET”, “7” blinks
►Press “▲/▼”, to adjust the days for disinfection monitoring,
►Press “SET” or “ESC” to save the setting
►Press “▲”, “DDIS 10Min” displays on the screen
►Press “SET”, “10” blinks
►Press “▲/▼”, to adjust the heating time of disinfection
►Press “SET” or “ESC” to save the setting
o
►Press “▲”, “TDIS 70 C” displays on the screen
o
►Press “SET”, “70 C” blinks
►Press “▲/▼”, to adjust the temperature of disinfection
►Press “SET” or “ESC” to save the setting
►Press “▲”, “SDIS 18:00” displays on the screen
►Press “SET”, “18” blinks
►Press “▲/▼”, to adjust the start time of the disinfection
►Press “SET” or “ESC” to save the setting
Menu structure
Function setting
►Select UNIT menu
o
►Press “SET”, “TEMP C” displays on the screen
o
►Press “SET”, “ C” blinks
►Press “▲/▼”, to select temperature unit
►Press “SET” or “ESC” to save the setting
28
Manual of SR208C intelligent controller
after you press”ESC” button.
Menu structure
Function setting
►Select RST menu
►Press “SET”, “RSTP” displays on the screen
►Press “SET”, “YES” blinks
►Press “SET” for 3 seconds, beeper sounds “di” 3 times, “YES”
lighting, and it indicates system is recovered to factory set.
►Press “ESC” return to the submenu
29
Manual of SR208C intelligent controller
7.12 PASS Password setup
Function description:
This function helps to customers to set up new password.
Menu structure
Function Setting
Select the password setting, “PASS” menu
To access main menu PASS,
►Press “SET” button, “PWDC 0000” appears,
►Press “SET” button,the left digital blinks, ask for entering current password, factory set is “0000”
►Press “▲/▼”,button to enter the first digital
►Repress “SET” button, the second digital blinks
►Press “▲/▼”,button to enter the second digital
►Repress “SET” button, the third digital blinks
►Press “▲/▼”,button to enter the third digital
►Repress “SET” button, the fourth digital blinks
►Press “▲/▼”, button to enter the fourth digital
►Press “SET” button, “PWDG 0000” displays on the screen, ask for reentering the new password,
doing like above to reenter the new password, “OK” displays on the screen to indicate reentering
password successfully.
Note: If the password is forgot, it is impossible to recover, but you can recover the password to
factory set, then you can reedit a password like above descript steps, doing like following to
recover to factory set.
► Switch-off the power to controller
► Hold down “ESC” button
► Reconnect the power supply, when beeper sounds 3 di….., and then release “ESC” button,
Controller recovers to the factory set password (factory set possword is 0000),
30
Manual of SR208C intelligent controller
you press the manual heating button, heating will start, and it works until tank temperature reaches to
the set point.
Note: 1).Manual heating is not a continuous heating process, it is triggered manually, and when
the temperature reaches to the set point, the heating process is stopped. And manual heating function
is stopped automatically.
2).AHO>AHF: Thermostat function for using surplus energy, manual heating is not available.
8. Protection function
31
Manual of SR208C intelligent controller
with controller itself. The following description of some well-known problems should help the installer
and operator to isolate the problem, so that the system can be put into operation as quickly as possible
and to avoid unnecessary cost. Of course, not all possible problems can be listed here. However, most
of the normal problems encountered with the controller can be found in the list below, only return the
controller to seller when you are absolutely sure that none of the problems listed below is responsible
for the fault.
9. Quality Guarantee
Manufacturer provides following quality responsibilities to end-users: within the period of quality
responsibilities, manufacturer will exclude the failure caused by production and material selection. A
correct installation will not lead to failure. When a user takes incorrect handling way, incorrect
installation, improper or crude handling, and wrong connection of Warm water outflow upwards?
The quality warranty expires within 18 months after the date of purchasing the controller.
32
Manual of SR208C intelligent controller
10. Accessories
SR802 Dimension:100mm*100mm*65mm
Unit for high power Power supply: AC180V ~ 264V, 50/60Hz
electrical heater Suitable power: ≤ 4000W
o
Available ambient temperature: -10 ~ 50 C
Waterproof grade: IP43
33
Manual of SR208C intelligent controller
SR802 connection diagram
34