Lowara 8 Inch Bore Hole
Lowara 8 Inch Bore Hole
Lowara 8 Inch Bore Hole
Z855, Z875
Z895, Z8125
Series
8” SUBMERSIBLE
ELECTRIC PUMPS
2
CONTENTS
3
4
8” MARKET SECTORS
Submersible AGRICULTURAL, INDUSTRIAL.
Electric APPLICATIONS
APPLICATIONS
Pumps • Water supply from deep wells.
• Pressure boosting and water distribution in civil and
industrial systems.
Z855 • Supply of surge tanks and reservoirs.
Z875 • Firefighting and washing systems.
Z895 • Water level control.
• Irrigation.
Z8125
• Mining.
Series
SPECIFICATIONS
SPECIFICATIONS
PUMP
CONSTRUCTION
• Delivery
Delivery: up to 180 m3/h.
• Head
Head: up to 550 m.
FEA TURES
FEATURES
• Maximum pump overall diameter PUMP
(2 cable covers included): • Robust and lightweight, easy to
198 mm for all versions. maintain and corrosion resistant in
• Maximum electric pump immersion non-aggressive environments.
depth: - Impellers and diffusers
350 m with L6W, L8W, L10W motors. made of stainless steel
steel.
• Maximum permissible quantity of - Delivery casing made of
suspended sand: 100 g/m3. stainless steel
steel.
• Standard delivery outlet: - Non-return valve made of
Rp 5” for all versions. stainless steel
steel, with
• Motor power: from 5,5 to 150 kW. integrated spring
spring.
- Suction support made of
stainless steel
steel.
MOTOR
- Shaft made of stainless steel
steel.
• L6W, L8W, L10W rewindable
• The guide bearing and wear rings
three-phase motors with water
ensure high resistance to wear and
filled winding.
guarantee the costant and
• Three-phase version:
long-lasting performance of
L6W: 4 to 37 kW 380-415 V 50 Hz.
the hydraulic characteristics
characteristics.
L8W: 30 to 93 kW 380-415 V 50 Hz.
• Coupling and flange mounting
L10W: 93 to 150 kW 380-415 V 50 Hz.
dimensions meet NEMA standards.
• Maximum supply voltage variations:
• ZR8 version in DUPLEX stainless
L6W, L8W, L10W 400V ±10%.
steel is also available.
• PVC windings for L6W, L8W, L10W.
• Horizontal operation:
L6W, L8W, L10W all versions are
OPTIONAL FEATURES
FEATURES
designed for horizontal installation, MOTOR
provided that the direction of the axial • Different voltages and frequencies.
thrust generated by the impellers is • High temperature versions.
always from the pump to the motor.
• Maximum number of starts per hour: ACCES SORIES
ACCESSORIES
15 (L6W), 10 (L8W) and 8 (L10W). • Coupling flange.
• Maximum temperature of water in • Panels.
contact with motor: • Cables.
L6W, L8W and L10W 30°C. • Splices.
5
TTABELLA
ABLE OFMATERIALI
MA Z8
TERIALS
MATERIALS Z8
COMPONENT MATERIAL DESIGNATION
EUROPE USA
Delivery head / Valve Casing Stainless steel EN 10213-4-GX5CrNi19-10 (1.4308) A744-CF 8
Valve Stainless steel EN 10213-4-GX5CrNi19-10 (1.4308) A744-CF 8
Valve seat NBR 90
Valve spring Stainless steel EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316
Diffuser / Bowl Stainless steel EN 10213-4-GX5CrNi19-10 (1.4308) A744-CF 8
Diffuser O-Ring NBR 70
Impeller Stainless steel EN 10213-4-GX5CrNi19-11 (1.4308) A744-CF 8
Taperlock Duplex stainless steel EN 10088-1-X2CrNiMoN22-5-3 (1.4462) A276/A790-S31803
Wear ring POM (DELRIN ®)
Lower support / Suction Casing Stainless steel EN 10213-4-GX5CrNi19-10 (1.4308) A744-CF 8
Suction strainer Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI 304
Pump shaft Stainless steel EN 10088-1-X17CrNi16-2 (1.4057) AISI 431
Coupling Stainless steel EN 10088-1-X2CrNiMoN22-5-3 (1.4462) A276/A790-S31803
Bearing bush EPDM + LOXAMID ®
Thrust Bearing PTFE + 25% carbon
Screw, stud, nut Stainless steel ISO 3506-1/2 A4-70 AISI 316
Cable protection Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI 304
IDENTIFICATION CODES
IDENTIFICATION
Z R 8 9 5 1 0 / 3 A L8W
MOTOR CODE
REDUCTION TYPE
NUMBER OF REDUCED STAGES
NUMBER OF STAGES
FLOW RATE IN m3/h
TYPE OF PUMP (R = DUPLEX VERSION)
BLANK = 50 Hz
6 = 60 Hz
6
Z8 SERIES
HYDRA ULIC PERFORMANCE RANGE A
HYDRAULIC T 50 Hz
AT
7
Z855 SERIES, 1 TO 7 ST AGES
STAGES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z855 2 poli 50 Hz
OPERA
OPERATINGTING CHARACTERISTIC
CHARACTERISTICS S AATT 50 Hz
Q = DELIVERY
PUMP MOTOR l/min 0 167 500 833 1217 1333
3
TYPE POWER m /h 0 10 30 50 73 80
kW H = TOTAL HEAD METRES COLUMN OF WATER
Z855 01 5,5 28,7 28 27 23 14 10,2
Z855 02/2A 7,5 45,7 44,4 43 35 14,9
Z855 02/1A 7,5 51,3 49,9 48 40 20,5
Z855 02 9,3 57 55,6 53 45 27 19,7
Z855 03/2A 11 74,2 72,1 69 57 27,7
Z855 03 15 86,1 83,9 80 69 41 30,7
Z855 04/2A 15 102,7 99,9 96 79 41
Z855 04 18,5 114,6 111,7 107 91 55 40,7
Z855 05/3A 18,5 125,6 122,2 117 97 49
Z855 05/2A 22 132,3 128,8 124 104 56,7
Z855 05 22 143,5 139,8 134 114 68 50,5
Z855 06/2A 26 160,7 156,6 150 127 70,9
Z855 06 30 172 167,6 160 137 83 61,3
Z855 07/2A 30 188,6 183,6 176 148 82,3
Z855 07 30 199,7 194,5 186 158 93 68,8
z855-2p50-en_b_th
DIMENSIONI E PESI SERIE Z855 2 poli 50 Hz
DIMENSIONS AND WEIGHTS
ELECTRO ELECTRO
PUMP DIMENSIONS (mm) PUMP
TYPE WEIGHT
(4) (1) M (2) (3)
A C Tmin kg
Z855 01-L6W 1173 200 144 1613 68,6
Z855 02/2A-L6W 1348 200 144 1653 81,2
Z855 02/1A-L6W 1348 200 144 1653 81,2
Z855 02-L6W 1378 200 144 1683 85,2
Z855 03/2A-L6W 1553 200 144 1723 97,9
Z855 03-L6W 1663 200 144 1833 109,9
Z855 04/2A-L6W 1798 200 144 1833 118,5
Z855 04-L6W 1868 200 144 1903 126,5
Z855 05/3A-L6W 2003 200 144 1903 135,2
Z855 05/2A-L6W 2043 200 144 1943 138,2
Z855 05-L6W 2043 200 144 1943 138,2
Z855 06/2A-L6W 2306 200 144 2071 155,8
Z855 06-L6W 2386 200 144 2151 163,8
Z855 07/2A-L6W 2521 200 144 2151 172,5
Z855 07-L6W 2521 200 144 2151 172,5
z855-2p50-en_b_td
8
Z855 SERIES, 1 TO 7 STAGES
STAGES
OPERA TING CHARACTERISTIC
OPERATING CHARACTERISTICS S AT 50 Hz
AT
9
Z855 SERIES, 8 TO 19 ST AGES
STAGES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z855 2 poli 50 Hz
OPERA
OPERATINGTING CHARACTERISTIC
CHARACTERISTICS S AATT 50 Hz
Q = DELIVERY
PUMP MOTOR l/min 0 167 500 833 1217 1333
3
TYPE POWER m /h 0 10 30 50 73 80
kW H = TOTAL HEAD METRES COLUMN OF WATER
Z855 08/2A 37 217 211,5 202,8 171 96,1
Z855 08 37 228,3 222,5 212,7 181 107,3 79,4
Z855 09/2A 37 244,8 238,3 227,8 191,2 106,8
Z855 09 45 260,6 254,2 244,3 210,6 128,5 96,9
Z855 10/2A 45 277,5 270,5 260,1 221,5 128,4
Z855 10 45 288,8 281,7 270,3 231,9 140,2 105,2
Z855 11/2A 45 305,6 298 286,6 244,8 143,2
Z855 11 52 316,9 309,2 296,8 255,4 155,4 116,9
Z855 12 52 346,6 338,3 324,8 279,8 170,5 128,5
Z855 13 55 375,3 366,1 351,3 302,3 183,7 138,2
Z855 14 67 404,5 394,7 379,1 326,6 198,9 149,9
Z855 15 67 432,8 422,2 404,9 348 210,9 158,4
Z855 16 75 461,6 450,3 432,1 372,2 226,5 170,5
Z855 17 75 491,8 479,8 461,2 398,8 244,6 185
Z855 18 83 520 507,3 487,4 420,8 257 194
Z855 19 93 551,2 538 517 446,3 273,5 206,9
z855a-2p50-en_b_td
10
Z855 SERIES, 8 TO 19 STAGES
STAGES
OPERA TING CHARACTERISTIC
OPERATING CHARACTERISTICSS AT 50 Hz
AT
11
Z875 SERIES, 1 TO 6 ST AGES
STAGES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z875 2 poli 50 Hz
OPERA
OPERATINGTING CHARACTERISTIC
CHARACTERISTICS S AATT 50 Hz
Q = DELIVERY
PUMP MOTOR l/min 0 250 700 1167 1500 1750
TYPE POWER m3/h 0 15 42 70 90 105
kW H = TOTAL HEAD METRES COLUMN OF WATER
Z875 01 5,5 27,3 26,1 24 21,2 16,8 12,7
Z875 02/2A 7,5 41,1 39,2 36,3 28,9 19,7 10,7
Z875 02/1A 9,3 47,7 46 42 35,3 26,5 17,9
Z875 02 11 53,9 51,5 47,4 41,7 32,8 24,6
Z875 03/3A 11 61,2 58,4 54,1 42,9 29 15,6
Z875 03/2A 13 68,7 65,6 60,7 50,3 36,8 23,7
Z875 03/1A 15 74,8 71,5 65,9 56,2 43,1 30,4
Z875 03 18,5 82 78,4 72,1 63,5 50,3 38,1
Z875 04/2A 18,5 95,4 91,1 84,1 70,6 52,9 35,8
Z875 04 22 109,3 104,5 96,2 84,7 67,1 50,8
Z875 05/2A 26 125,1 119,6 110,4 94,1 72,3 50,9
Z875 05 30 137,6 131,6 121,1 106,8 84,9 64,4
Z875 06/2A 30 152,8 146,1 134,8 115,5 89,6 64
Z875 06/1A 30 158,4 151 139,6 120,9 95,3 70,2
Z875 06 37 166,8 159,6 147 132,3 103,8 79,2
z875-2p50-en_c_th
DIMENSIONI E PESI SERIE Z875 2 poli 50 Hz
DIMENSIONS AND WEIGHTS
ELECTRO ELECTRO
PUMP DIMENSIONS (mm) PUMP
TYPE WEIGHT
(4) (1) M (2) (3)
A C Tmin kg
Z875 01-L6W 1190 200 144 1613 68,9
Z875 02/2A-L6W 1382 200 144 1653 82,2
Z875 02/1A-L6W 1412 200 144 1683 86,2
Z875 02-L6W 1452 200 144 1723 90,2
Z875 03/3A-L6W 1604 200 144 1723 99,4
Z875 03/2A-L6W 1644 200 144 1763 103,4
Z875 03/1A-L6W 1714 200 144 1833 111,4
Z875 03-L6W 1784 200 144 1903 119,4
Z875 04/2A-L6W 1936 200 144 1903 128,6
Z875 04-L6W 1976 200 144 1943 131,6
Z875 05/2A-L6W 2256 200 144 2071 149,9
Z875 05-L6W 2336 200 144 2151 157,9
Z875 06/2A-L6W 2488 200 144 2151 167,1
Z875 06/1A-L6W 2488 200 144 2151 167,1
Z875 06-L6W 2638 200 144 2301 181,1
z875-2p50-en_c_td
12
Z875 SERIES, 1 TO 6 STAGES
STAGES
OPERA TING CHARACTERISTIC
OPERATING CHARACTERISTICS S AT 50 Hz
AT
13
Z875 SERIES, 7 TO 18 ST AGES
STAGES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z875 2 poli 50 Hz
OPERA
OPERATINGTING CHARACTERISTIC
CHARACTERISTICS S A T 50 Hz
AT
Q = DELIVERY
PUMP MOTOR l/min 0 250 500 750 1000 1250 1500 1750
TYPE POWER m3/h 0 15 30 45 60 75 90 105
kW H = TOTAL HEAD METRES COLUMN OF WATER
Z875 07/2A 37 180,7 171,6 165,4 158,3 147,5 130,9 107,4 76,6
Z875 07 45 192,2 181,9 175,6 168,7 158 141,6 118,8 90,2
Z875 08/2A 45 209,8 199,4 192,2 184 171,7 152,9 126,3 91,2
Z875 08 45 221,9 210,1 202,9 195 182,8 164,1 138,1 105,5
Z875 09/2A 45 233,7 222 213,8 204,6 190,8 169,6 139,6 100
Z875 09/1A 52 244,6 232,4 223,8 214,4 200,8 180,3 150,9 111,7
Z875 09 52 251,4 238,1 229,8 221 207,3 186,3 157,1 120,5
Z875 10/2A 52 265,7 252,5 243,2 233 217,7 194,5 161,4 117,6
Z875 10 55 277,4 262,7 253,6 243,7 228,5 205,1 172,6 131,9
Z875 11/2A 55 289,6 275,1 264,9 253,6 236,8 211,2 174,8 126,5
Z875 11 60 303,1 286,9 276,9 266,1 249,3 223,5 187,7 142,9
Z875 12 67 330,7 313 302,1 290,3 272 243,8 204,8 155,9
Z875 13 75 358,2 339,1 327,3 314,5 294,7 264,2 221,8 168,9
Z875 14 83 385,8 365,1 352,5 338,7 317,3 284,5 238,9 181,8
Z875 15 83 411,9 389,8 376,3 361,5 338,6 303,4 254,5 193,4
Z875 16 93 439,3 415,8 401,4 385,6 361,2 323,6 271,5 206,3
Z875 17 93 468,4 443,4 428 411,3 385,4 345,5 290,1 220,8
Z875 18 110 496 469,5 453,2 435,5 408 365,8 307,2 233,8
DIMENSIONI E PESI SERIE Z875 2 poli 50 Hz z875a-2p50-en_c_th
14
Z875 SERIES, 7 TO 18 STAGES
STAGES
OPERA TING CHARACTERISTIC
OPERATING CHARACTERISTICSS AT 50 Hz
AT
15
Z895 SERIES, 1 TO 6 ST AGES
STAGES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z895 2 poli 50 Hz
OPERA
OPERATINGTING CHARACTERISTIC
CHARACTERISTICS S AATT 50 Hz
Q = DELIVERY
PUMP MOTOR l/min 0 367 1000 1500 2150 2300
3
TYPE POWER m /h 0 22 60 90 129 138
kW H = TOTAL HEAD METRES COLUMN OF WATER
Z895 01 7,5 28,5 27,7 25,3 21,6 12,3 9,8
Z895 02/2B 11 38,7 38,3 35,2 27,5
Z895 02/2A 13 47,7 46,6 44 36,4 17,8
Z895 02 15 57 55,4 50,7 43,2 24,6 19,5
Z895 03/2B 18,5 67,2 66,1 60,8 49,4
Z895 03/1A 22 81,1 79 73 61,8 34
Z895 03 26 86 83,8 77,3 66,4 39 30,4
Z895 04/2B 26 96 94,1 86,7 71,8
Z895 04/2A 30 104,5 102 94,7 79,7 42,5
Z895 04 30 113,8 110,7 101,4 86,5 49,3 39,2
Z895 05/3A 37 128 125 116,4 97,5 50,8
Z895 05 37 141,9 138 126,4 107,5 60,9 48,7
Z895 06/3A 45 158,4 154,8 144,6 122,4 67,1
Z895 06 45 172,6 168,1 154,9 132,8 77,7 60,5
z895-2p50-en_b_th
DIMENSIONI E PESI SERIE Z895 2 poli 50 Hz
DIMENSIONS AND WEIGHTS
ELECTRO ELECTRO
PUMP DIMENSIONS (mm) PUMP
TYPE TYPE
(4) (1) M (2) (3)
A C Tmin kg
Z895 01-L6W 1230 200 144 1653 72,9
Z895 02/2B-L6W 1452 200 144 1723 90,2
Z895 02/2A-L6W 1492 200 144 1763 94,2
Z895 02-L6W 1562 200 144 1833 102,2
Z895 03/2B-L6W 1784 200 144 1903 119,4
Z895 03/1A-L6W 1824 200 144 1943 122,4
Z895 03-L6W 1952 200 144 2071 131,4
Z895 04/2B-L6W 2104 200 144 2071 140,6
Z895 04/2A-L6W 2184 200 144 2151 148,6
Z895 04-L6W 2184 200 144 2151 148,6
Z895 05/3A-L6W 2486 200 144 2301 171,9
Z895 05-L6W 2486 200 144 2301 171,9
Z895 06/3A-L8W 2532 203,3 192 2195 253,1
Z895 06-L8W 2532 203,3 192 2195 253,1
z895-2p50-en_b_td
16
Z895 SERIES, 1 TO 6 STAGES
STAGES
OPERA TING CHARACTERISTIC
OPERATING CHARACTERISTICS S AT 50 Hz
AT
The flow resistance of the ∆Hv non-return valve has been considered.
∆Hv = 0,0000533*Q2 Flow resistance = 0,2 / 0,45 / 0,75 m at 60 / 90 / 120 m3/h
These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec.
17
Z895 SERIES, 7 TO 18 ST AGES
STAGES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z895 2 poli 50 Hz
OPERA
OPERATINGTING CHARACTERISTIC
CHARACTERISTICS S AATT 50 Hz
Q = DELIVERY
PUMP MOTOR l/min 0 367 1000 1500 2150 2300
TYPE POWER m3/h 0 22 60 90 129 138
kW H = TOTAL HEAD METRES COLUMN OF WATER
Z895 07/3A 52 186,5 182,1 169,6 144 79,8
Z895 07 52 201,5 196,4 181,3 156,2 92,4 72,4
Z895 08/3A 55 215,7 210,6 196 166,7 93,3
Z895 08 60 229,9 223,9 206,3 177,2 104 81,1
Z895 09/3A 67 244,4 238,6 221,9 188,9 106,2
Z895 09 67 258,9 252,4 233 200,8 119 93,2
Z895 10/3A 75 272,9 266,3 247,3 210,9 119,3
Z895 10 75 287 279,6 257,6 221,5 130 101,4
Z895 11 83 316,3 308,2 284,6 245,2 145 113,4
Z895 12 93 346,3 337,6 311,5 268,1 158,8 124,4
Z895 13 110 374,9 365,6 338,1 291,9 174 137,5
Z895 14 110 403,1 393 363 312,8 185,4 145,2
Z895 15 130 434,2 423,5 391,4 337,7 201,8 159
Z895 16 130 462,6 451 416,2 358,6 213,2 169
Z895 17 130 490,9 478,4 440,9 379,4 224,2 175,5
Z895 18 150 520,2 507,1 468,5 404,2 241 189,3
z895a-2p50-en_c_td
18
Z895 SERIES, 7 TO 18 STAGES
STAGES
OPERA TING CHARACTERISTIC
OPERATING CHARACTERISTICSS AT 50 Hz
AT
The flow resistance of the ∆Hv non-return valve has been considered.
∆Hv = 0,0000533*Q2 Flow resistance = 0,2 / 0,45 / 0,75 m at 60 / 90 / 120 m3/h
These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec.
19
Z8125 SERIES, 1 TO 6 ST AGES
STAGES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z8125 2 poli 50 Hz
OPERA
OPERATINGTING CHARACTERISTIC
CHARACTERISTICS S AATT 50 Hz
Q = DELIVERY
PUMP MOTOR l/min 0 500 1333 2083 2800 3000
3
TYPE POWER m /h 0 30 80 125 168 180
kW H = TOTAL HEAD METRES COLUMN OF WATER
Z8125 01 7,5 27,1 24,7 21 17,1 9,4 6,9
Z8125 02/2B 11 41,9 38,8 31,8 22,3
Z8125 02/2A 13 48,3 44,6 37,5 28,9 13
Z8125 02 15 54,3 49,5 42 34,1 18,8 13,7
Z8125 03/3A 18,5 71,9 66,2 55,5 42,6 19,3
Z8125 03 22 81,7 74,6 63,4 51,5 28,7 20,7
Z8125 04/2B 26 97 89,2 74,8 57,5
Z8125 04/2A 30 102,6 94,1 79,5 63,1 32,9
Z8125 04 30 108,5 99 84,1 68,3 37,8 27,5
Z8125 05/3A 37 126,4 116 97,9 77,1 39,3
Z8125 05 37 135,2 123,4 104,7 84,8 46,6 34,2
Z8125 06/3A 45 156,4 143,5 121,7 97,1 50,2
Z8125 06 45 165,5 151,1 128,8 105 60 41,9
z8125-2p50-en_b_th
DIMENSIONI E PESI SERIE Z8125 2 poli 50 Hz
DIMENSIONS AND WEIGHTS
ELECTRO ELECTRO
PUMP DIMENSIONS (mm) PUMP
TYPE WEIGHT
(4) (1) M (2) (3)
A C Tmin kg
Z8125 01-L6W 1230 200 144 1653 72,9
Z8125 02/2B-L6W 1452 200 144 1723 90,2
Z8125 02/2A-L6W 1492 200 144 1763 94,2
Z8125 02-L6W 1562 200 144 1833 102,2
Z8125 03/3A-L6W 1784 200 144 1903 119,4
Z8125 03-L6W 1824 200 144 1943 122,4
Z8125 04/2B-L6W 2104 200 144 2071 140,6
Z8125 04/2A-L6W 2184 200 144 2151 148,6
Z8125 04-L6W 2184 200 144 2151 148,6
Z8125 05/3A-L6W 2486 200 144 2301 171,9
Z8125 05-L6W 2486 200 144 2301 171,9
Z8125 06/3A-L8W 2532 203,3 192 2195 253,1
Z8125 06-L8W 2532 203,3 192 2195 253,1
z8125-2p50-en_b_td
20
Z8125 SERIES, 1 TO 6 STAGES
STAGES
OPERA TING CHARACTERISTIC
OPERATING CHARACTERISTICSS AT 50 Hz
AT
The flow resistance of the ∆Hv non-return valve has been considered.
∆Hv = 0,0000533*Q2 Flow resistance = 0,35 / 0,75 / 1,35 m at 80 / 120 / 160 m3/h
These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec.
21
Z8125 SERIES, 7 TO 18 ST AGES
STAGES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z8125 2 poli 50 Hz
OPERA
OPERATINGTING CHARACTERISTIC
CHARACTERISTICS S AATT 50 Hz
Q = DELIVERY
PUMP MOTOR l/min 0 500 1333 2083 2800 3000
3
TYPE POWER m /h 0 30 80 125 168 180
kW H = TOTAL HEAD METRES COLUMN OF WATER
Z8125 07/3A 52 183,3 168 142,6 114,3 60,2
Z8125 07 52 192,3 175,6 149,8 122,5 69,8 48,8
Z8125 08/3A 55 210,9 193,2 164,1 131,8 70,3
Z8125 08 60 220,5 201,3 171,8 140,4 80,3 55,9
Z8125 09/3A 67 239 218,9 186 149,8 80,6
Z8125 09 67 248,1 226,5 193,2 157,8 90,3 62,9
Z8125 10/3A 75 266,2 243,7 207,3 167,4 90,7
Z8125 10 75 275,3 251,4 214,6 175,4 100,3 69,9
Z8125 11 83 304,2 277,8 237,4 194,4 112,2 76,8
Z8125 12 93 332,7 303,9 259,6 212,5 123 84,5
Z8125 13 93 361,2 329,9 282,3 231,6 134,9 93,1
Z8125 14 110 387,9 354,2 302,8 248 143,5 98,5
Z8125 15 110 414,3 378,3 323 264,2 151,9 104
Z8125 16 130 444,5 406 347 284,4 165,3 113,9
Z8125 17 130 470,9 430,1 367,3 300,6 173,7 119,5
Z8125 18 150 500,4 457,1 391 320,8 186,8 128,9
z8125a-2p50-en_b_td
22
Z8125 SERIES, 7 TO 18 STAGES
STAGES
OPERA TING CHARACTERISTIC
OPERATING CHARACTERISTICSS A T 50 Hz
AT
The flow resistance of the ∆Hv non-return valve has been considered.
∆Hv = 0,0000533*Q2 Flow resistance = 0,35 / 0,75 / 1,35 m at 80 / 120 / 160 m3/h
These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec.
23
Z855 SERIES
DIMENSIONI E PESI POMPE SERIE Z855 2 Poli 50 Hz
DIMENSIONS AND WEIGHTS
MAX POWER
PUMP ABSORBED BY PUMP DIMENSIONS (mm) WEIGHT
TYPE at 2900 min-1
kW (3) I (2) (3)
L Umin kg
Z855 01-6 4,6 325 235 1000 26,6
Z855 02/2A-6 6,4 460 235 1000 35,2
Z855 02/1A-6 7,7 460 235 1000 35,2
Z855 02-6 9,0 460 235 1000 35,2
Z855 03/2A-6 10,8 595 235 1000 43,9
Z855 03-6 13,3 595 235 1000 43,9
Z855 04/2A-6 15,1 730 235 1000 52,5
Z855 04-6 17,6 730 235 1000 52,5
Z855 05/3A-6 18,3 865 235 1000 61,2
Z855 05/2A-6 20,8 865 235 1000 61,2
Z855 05-6 22,0 865 235 1000 61,2
Z855 06/2A-6 23,9 1000 235 1000 69,8
Z855 06-6 26,4 1000 235 1000 69,8
Z855 07/2A-6 28,3 1135 235 1000 78,5
Z855 07-6 30,8 1135 235 1000 78,5
Z855 08/2A-6 32,7 1270 235 1000 87,1
Z855 08-6 35,2 1270 235 1000 87,1
Z855 09/2A-6 37,1 1405 235 1000 95,8
Z855 09-8 39,6 1405 235 1000 95,1
Z855 10/2A-8 41,5 1540 235 1000 103,8
Z855 10-8 44,0 1540 235 1000 103,8
Z855 11/2A-8 45,9 1675 235 1000 112,4
Z855 11-8 48,4 1675 235 1000 112,4
Z855 12-8 52,8 1810 235 1000 121,1
Z855 13-8 57,2 1945 235 1000 129,7
Z855 14-8 61,6 2080 235 1000 138,4
Z855 15-8 66,0 2215 235 1000 147
Z855 16-8 70,4 2350 235 1000 155,7
Z855 17-8 74,8 2485 235 1000 164,3
Z855 18-8 79,2 2620 235 1000 173
Z855 19-8 83,6 2755 235 1000 181,6
N k d z b H7 R X
E
6" (NEMA) 182 111 13,5 4 17 76,16 73 24
8" (NEMA) 182 152,4 18 4 17 127 101,3 40
24
Z875 SERIES
DIMENSIONI E PESI POMPE SERIE Z875 2 Poli 50 Hz
DIMENSIONS AND WEIGHTS
MAX POWER
PUMP ABSORBED BY PUMP DIMENSIONS (mm) WEIGHT
TYPE a 2900 min-1
kW (3) I (2) (3)
L Umin kg
Z875 01-6 5,6 342 235 1000 26,9
Z875 02/2A-6 7,4 494 235 1000 36,2
Z875 02/1A-6 9,2 494 235 1000 36,2
Z875 02-6 11,1 494 235 1000 36,2
Z875 03/3A-6 11,1 646 235 1000 45,4
Z875 03/2A-6 12,9 646 235 1000 45,4
Z875 03/1A-6 14,7 646 235 1000 45,4
Z875 03-6 16,7 646 235 1000 45,4
Z875 04/2A-6 18,3 798 235 1000 54,6
Z875 04-6 22,3 798 235 1000 54,6
Z875 05/2A-6 23,8 950 235 1000 63,9
Z875 05-6 27,9 950 235 1000 63,9
Z875 06/2A-6 29,3 1102 235 1000 73,1
Z875 06/1A-6 31,3 1102 235 1000 73,1
Z875 06-6 33,3 1102 235 1000 73,1
Z875 07/2A-6 34,8 1254 235 1000 82,3
Z875 07-8 39,0 1254 235 1000 82,3
Z875 08/2A-8 40,4 1406 235 1000 90,9
Z875 08-8 44,6 1406 235 1000 90,9
Z875 09/2A-8 45,9 1558 235 1000 100,1
Z875 09/1A-8 47,9 1558 235 1000 100,1
Z875 9-8 50,1 1558 235 1000 100,1
Z875 10/2A-8 51,5 1710 235 1000 109,4
Z875 10-8 55,7 1710 235 1000 109,4
Z875 11/2A-8 57,0 1862 235 1000 118,6
Z875 11-8 61,3 1862 235 1000 118,6
Z875 12-8 66,8 2014 235 1000 127,8
Z875 13-8 72,4 2166 235 1000 137
Z875 14-8 78,0 2318 235 1000 146,3
Z875 15-8 83,6 2470 235 1000 155,5
Z875 16-8 89,1 2622 235 1000 164,7
Z875 17-8 94,7 2774 235 1000 174
Z875 18-10 100,3 2926 256 1000 183,2
DIMENSIONI ACCOPPIAMENTO MOTORI POMPE SERIEz875p-2p50-en_c_td
Z8 2 Poli
MOTOR COUPLING
MOTOR DIMENSIONS (mm)
H7
N k d z b E R X
6" (NEMA) 182 111 13,5 4 17 76,16 73 24
8" (NEMA) 182 152,4 18 4 17 127 101,3 40
10" 232 190,5 M16 4 21 127 101,3 84
6" and 8" coupling according to NEMA standards
z8a-mtcn-2p50-en_a_td
25
Z895 SERIES
DIMENSIONI E PESI POMPE SERIE Z895 2 Poli 50 Hz
DIMENSIONS AND WEIGHTS
MAX POWER
PUMP ABSORBED BY PUMP DIMENSIONS (mm) WEIGHT
TYPE at 2900 min-1
kW (3) I (2) (3)
L Umin kg
Z895 01-6 7,7 342 235 1000 26,9
Z895 02/2B-6 10,0 494 235 1000 36,2
Z895 02/2A-6 12,8 494 235 1000 36,2
Z895 02-6 15,2 494 235 1000 36,2
Z895 03/2B-6 17,4 646 235 1000 45,4
Z895 03/1A-6 21,4 646 235 1000 45,4
Z895 03-6 22,5 646 235 1000 45,4
Z895 04/2B-6 24,6 798 235 1000 54,6
Z895 04/2A-6 27,4 798 235 1000 54,6
Z895 04-6 29,8 798 235 1000 54,6
Z895 05/3A-6 33,7 950 235 1000 63,9
Z895 05-6 37,2 950 235 1000 63,9
Z895 06/3A-8 41,1 1102 235 1000 73,1
Z895 06-8 44,6 1102 235 1000 73,1
Z895 07/3A-8 48,6 1254 235 1000 81,7
Z895 07-8 52,1 1254 235 1000 81,7
Z895 08/3A-8 56,0 1406 235 1000 90,9
Z895 08-8 59,5 1406 235 1000 90,9
Z895 09/3A-8 63,5 1558 235 1000 100,1
Z895 09-8 67,0 1558 235 1000 100,1
Z895 10/3A-8 70,9 1710 235 1000 109,4
Z895 10-8 74,4 1710 235 1000 109,4
Z895 11-8 81,8 1862 235 1000 118,6
Z895 12-8 89,3 2014 235 1000 127,8
Z895 1310 96,7 2166 256 1000 137
Z895 14-10 104,2 2318 256 1000 146,3
Z895 15-10 111,6 2470 256 1000 155,5
Z895 16-10 119,0 2622 256 1000 164,7
Z895 17-10 126,5 2774 256 1000 174
Z895 18-10 133,9 2926 256 1000 183,2
H7
N k d z b E R X
6" (NEMA) 182 111 13,5 4 17 76,16 73 24
8" (NEMA) 182 152,4 18 4 17 127 101,3 40
10" 232 190,5 M16 4 21 127 101,3 84
6" and 8" coupling according to NEMA standards
z8a-mtcn-2p50-en_a_td
26
Z8125 SERIES
DIMENSIONI E PESI POMPE SERIE Z8125 2 Poli 50 Hz
DIMENSIONS AND WEIGHTS
MAX POWER
PUMP ABSORBED BY PUMP DIMENSIONs (mm) WEIGHT
TYPE at 2900 min-1
kW (3) I (2) (3)
L Umin kg
Z8125 01-6 7,5 342 235 1000 26,9
Z8125 02/2B-6 10,0 494 235 1000 36,2
Z8125 02/2A-6 12,2 494 235 1000 36,2
Z8125 02-6 14,8 494 235 1000 36,2
Z8125 03/3A-6 18,1 646 235 1000 45,4
Z8125 03-6 22,0 646 235 1000 45,4
Z8125 04/2B-6 24,3 798 235 1000 54,6
Z8125 04/2A-6 26,5 798 235 1000 54,6
Z8125 04-6 29,0 798 235 1000 54,6
Z8125 05/3A-6 32,5 950 235 1000 63,9
Z8125 05-6 36,3 950 235 1000 63,9
Z8125 06/3A-8 39,7 1102 235 1000 73,1
Z8125 06-8 43,5 1102 235 1000 73,1
Z8125 07/3A-8 47,0 1254 235 1000 81,7
Z8125 07-8 50,8 1254 235 1000 81,7
Z8125 08/3A-8 54,2 1406 235 1000 90,9
Z8125 08-8 58,0 1406 235 1000 90,9
Z8125 09/3A-8 61,5 1558 235 1000 100,1
Z8125 09-8 65,3 1558 235 1000 100,1
Z8125 10/3A-8 68,7 1710 235 1000 109,4
Z8125 10-8 72,5 1710 235 1000 109,4
Z8125 11-8 79,8 1862 235 1000 118,6
Z8125 12-8 87,0 2014 235 1000 127,8
Z8125 13-8 94,3 2166 235 1000 137
Z8125 14-10 101,5 2318 256 1000 146,3
Z8125 15-10 108,8 2470 256 1000 155,5
Z8125 16-10 116,0 2622 256 1000 164,7
Z8125 17-10 123,3 2774 256 1000 174
Z8125 18-10 130,5 2926 256 1000 183,2
MOTOR COUPLING
MOTOR DIMENSIONS (mm)
H7
N k d z b E R X
6" (NEMA) 182 111 13,5 4 17 76,16 73 24
8" (NEMA) 182 152,4 18 4 17 127 101,3 40
10" 232 190,5 M16 4 21 127 101,3 84
6" and 8" coupling according to NEMA standards
z8a-mtcn-2p50-en_a_td
27
Z8 SERIES PUMPS
PUMP CROS
CROSSS SECTION AND LIST OF COMPONENTS
DENOMINAZIONE COMPONENTI
SERIE Z8-2poli 50 Hz
REF. N. DESCRIPTION
1 Stage casing
2 Suction casing
3 Delivery casing
4 Valve body
5 Bearing bush
6 Impeller
7 Wear ring
8 Shaft
9 Coupling
10 Locking sleeve
11 Thrust bearing
12 Wing valve
13 Valve seat
14 Valve spring
15 Suction strainer
16 Motor cable
17 Cable guard
18 O-ring
19 10" Motor adapter
20 Clampling plate
z8-2p50-en_a_tp
28
6” Submersible canned motors.
Submersible The choice of component materials ensures optimum
operating performances, superior quality, reliability and
motors
ease of installation.
L6C SPECIFICATIONS
SPECIFICATIONS • Axial thrust
thrust:
16000 N from 4 to 22 kW;
Series • Stainless steel outer sleeve.
27000 N from 30 to 37 kW.
• Shaft extension and coupling
dimensions to NEMA standards. • Extractable supply cable
• Class F insulation
insulation. fitted with watertight connector.
• Protection class: IP68
IP68. • Versions
ersions:
• Compensating bellows for internal - Three-phase:
liquid expansion. 4 to 22 kW 220-240 V, 50 Hz.
• Axial load supported by Kingsbury 4 to 37 kW 380-415 V, 50 Hz.
type thrust bearing. • Motors with double cable outlet for
• Mechanical seal protected by star/delta start can be supplied upon
sand guard. request.
• Maximum immersion depth depth: • Can also operate in horizontal
250 m. position, provided that the associated
• Maximum number of starts per pump can apply an axial thrust of at
hour at regular intervals: least 250 N on the entire operating
25 for direct start. field.
• Maximum supply voltage • Screws included.
variations allowed: ±10%.
• Maximum water temperature
temperature: OPTIONAL FEATURES
FEATURES
35°C. • Silicon Carbide mechanical seal.
Max. temperature applies to motors • Special voltages.
working in an installation capable of • Inverter applications.
delivering a flow of water around the • Temperature sensor PT 100 / PTC
PTC.
motor jacket of at least 0,2 m/s.
High starting
torque
Power supply
cable with
extractable
connector
29
L6C MOTOR SERIES
MOTOR CROS
CROSSS SECTION AND TABLE OF MA
TABLE TERIALS
MATERIALS
N° EUROPE USA
Inner and outer sleeve Stainless steel EN 10088-1-X2CrNi18-9 (1.4307) AISI304L
1
Flange Carbon steel EN 10025 - S355JR (Fe 510-B) ASTM A105
2 Shaft extension Stainless steel (Duplex) EN 10095 X3CrNiMoN27-5-2 (1.4460) AISI329
3 Upper bracket Cast iron EN-GJL-200 Class 25 B
4 Intermediate bracket Cast iron EN-GJL-200 Class 25 B
5 Mechanical seal Carbon graphite / Aluminium oxide
6 Elastomers NBR
7 Lower bracket Cast iron EN-GJL-200 Class 25 B
8 Compensating bellows NBR
9 Bearings Carbon-graphite
10 Cable EPDM
11 Fixed sand guard Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI304
12 Removable sand guard NBR
13 Bolts and screws Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI304
14 Lower cover Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI304
15 Mechanical seal spacer A105 nichel plated
16 Sand guard gasket CR neoprene
Cooling liquid Demineralized water + antifreeze
l6c-2p50-en_d_tm
30
L6C MOTOR SERIES
IDENTIFICATION CODE
IDENTIFICATION
L6C 110 T 40 5 /_
VERSION
5 = 50 Hz
6 = 60 Hz
RATED VOLTAGE
T = THREE-PHASE
RATED POWER IN kW x 10
EXAMPLE : L6C110T405
L6C MOTOR :
RATED POWER 11 kW; THREE-PHASE;
RATED VOLTAGE 400 V; 50 Hz.
RATING PLA
RATING TE
PLATE
LEGEND
1 - Motor type
2 - Code
3 - Maximum water temperature
4 - Minimum water velocity
5 - Insulation class
6 - Protection class
7 - Weight
8 - Maximum immersion depht
9 - Operating characteristics
10 - Production date
11 - Serial number
12 - Characteristics at service factor
13 - Service type
31
L6C MOTOR SERIES
DIMENSIONS AND WEIGHTS AT 50 Hz
AT
32
L6C MOTOR SERIES
L6C OPERATING CHARACTERISTICS - 50Hz
THREE-PHASE OPERA TING CHARACTERISTIC
OPERATING S A
CHARACTERISTICS T 50 Hz
AT
MOTOR RATED RATED OPERATING CHARACTERISTICS DIRECT MAX CABLE TYPE
TYPE POWER VOLTAGE AT RATED POWER START WATER
RATED
CURRENT TEMPERATURE Nc x sec L
THREE-PHASE kW HP V A rpm Ș% cosij Ts/Tn* Is/In °C mm
2
m
220 17,8 2825 75 0,8 1,7 3,9
L6C40T235 4 5,5 230 18,4 2845 74 0,75 1,7 3,9 35 4x4 4
240 19,1 2860 74 0,7 1,7 3,8
220 24,1 2820 77 0,8 1,8 3,8
L6C55T235 5,5 7,5 230 24,2 2845 76 0,75 1,8 3,8 35 4x4 4
240 25,3 2860 76 0,71 1,8 3,6
220 30,5 2820 78 0,82 2 3,9
L6C75T235 7,5 10 230 31,2 2840 77 0,78 2 3,9 35 4x4 4
240 31,7 2850 77 0,73 2 4
220 37,6 2820 78 0,82 2,1 3,8
L6C93T235 9,3 12,5 230 38,1 2840 79 0,8 2,1 3,9 35 4x6 4
240 39,5 2850 78 0,79 2,15 3,9
220 43,3 2815 77 0,87 2,1 4,5
L6C110T235 11 15 230 44,2 2840 78 0,82 2,1 4,5 35 4x6 4
240 45,0 2845 77 0,79 2,15 4,5
220 58,0 2810 80 0,84 2,2 4,1
L6C150T235 15 20 230 57,9 2840 81 0,8 2,2 4,1 35 4x8 4
240 59,2 2850 81 0,76 2,25 4,1
220 70,1 2820 81 0,83 2,3 4,3
L6C185T235 18,5 25 230 71,0 2845 82 0,8 2,3 4,3 35 4x8 4
240 72,7 2855 82 0,73 2,35 4,3
220 82,3 2810 81 0,88 2,3 4
L6C220T235 22 30 230 81,4 2825 82 0,84 2,3 4,1 35 4x8 4
240 82,3 2835 82 0,8 2,35 4,2
380 10,3 2825 75 0,8 1,7 3,9
L6C40T405 4 5,5 400 10,6 2845 74 0,75 1,7 3,9 35 4x4 4
415 11 2860 74 0,7 1,7 3,8
380 13,9 2820 77 0,8 1,8 3,8
L6C55T405 5,5 7,5 400 14 2845 76 0,75 1,8 3,8 35 4x4 4
415 14,6 2860 76 0,71 1,8 3,6
380 17,6 2820 78 0,82 2 3,9
L6C75T405 7,5 10 400 18 2840 77 0,78 2 3,9 35 4x4 4
415 18,3 2850 77 0,73 2 4
380 21,7 2820 78 0,82 2,1 3,8
L6C93T405 9,3 12,5 400 22 2840 79 0,8 2,1 3,9 35 4x4 4
415 22,8 2850 78 0,79 2,15 3,9
380 25 2815 77 0,87 2,1 4,5
L6C110T405 11 15 400 25,5 2840 78 0,82 2,1 4,5 35 4x4 4
415 26 2845 77 0,79 2,15 4,5
380 33,5 2810 80 0,84 2,2 4,1
L6C150T405 15 20 400 33,4 2840 81 0,8 2,2 4,1 35 4x4 4
415 34,2 2850 81 0,76 2,25 4,1
380 40,5 2820 81 0,83 2,3 4,3
L6C185T405 18,5 25 400 41 2845 82 0,8 2,3 4,3 35 4x6 4
415 42 2855 82 0,73 2,35 4,3
380 47,5 2810 81 0,88 2,3 4
L6C220T405 22 30 400 47 2825 82 0,84 2,3 4,1 35 4x6 4
415 47,5 2835 82 0,8 2,35 4,2
380 63 2810 82 0,89 2,4 4
L6C300T405 30 40 400 61,5 2830 82 0,85 2,4 4,1 35 4x8 4
415 63,5 2840 81 0,8 2,45 3,9
380 79,5 2820 82 0,87 2 3,7
L6C370T405 37 50 400 79,3 2830 81 0,84 2,2 3,9 35 4x8 4
415 80 2840 81 0,8 2,3 4
* Ts/Tn = ratio between starting torque and nominal torque. l6c-2p50-en_f_te
33
34
6” Water filled submersible motors.
Submersible The robust design together with excellent choise of materials
ensures optimal performance, ease of installation and reliability
motors
in all applications. For extremely demanding operation as high
water temperature or aggressive environments special versions
are available.
L6W
Series
SPECIFICATIONS
SPECIFICATIONS SPECIAL VERSIONS
• Stainless steel outer sleeve. • Motors with double cable outlet for
• Shaft extension and coupling star/delta start.
dimensions to NEMA standards. • L6WN series
series: complete range
• Rewindable stator stator. available realized of AISI 316
• Class Y insulation
insulation. stainless steel.
• Protection class: IP68
IP68. • L6WR series
series: complete range
• Compensating bellows for internal available realized of Duplex
liquid expansion. stainless steel.
• Axial load supported by Kingsbury • HT series
series: complete range
type thrust bearing. available for all the L6W/N/R
• Mechanical seal construction, realized for applications
protected by sand guard. in high temperature environments
• Maximum immersion depth depth: up to 60°C
(up 60°C) or under inverter.
350 m.
• Maximum number of starts per OPTIONAL FEATURES
FEATURES
hour at regular intervals: 15. • Silicon Carbide mechanical seal.
• Maximum supply voltage • Special voltages.
variations allowed : ±10%.
• Maximum water temperature
temperature: ACCES SORIES
ACCESSORIES
30°C. • Temperature sensor PT 100 / PTC
PTC.
Max. temperature applies to motors
working in a installation capable of
delivering a flow of water around the
motor jacket as following:
Standard versions 0,2 m/s (4÷9,3 kW),
0,3 m/s (11÷30 kW) and
0,5 m/s (37 kW).
HT versions 0,2 m/s (5,5÷7,5 kW),
0,3 m/s (9,3÷26 kW) and
0,5 m/s (30 kW).
• Axial thrust
thrust:
16000 N from 4 to 22 kW;
30000 N from 26 to 37 kW.
• Power supply cable suitable
for drinkable water.
Rewindable
• Versions
ersions:
stator - Three-phase:
4 to 37 kW 380-415 V, 50 Hz.
Thrust bearing • Horizontal operation
operation:
valid for all versions provided that the
Kingsbury direction of the axial thrust generated
type by the impellers is always from the
pump to the motor.
• Flat power supply cable.
Mechanical • Screws included.
seal
35
L6W - L6WN - L6WR MOTOR SERIES
MOTOR CROS S SECTION
CROSS
36
MOTORI SERIE L6W: TABELLA MATERIALI
L6W TABLE OF MA
TABLE TERIALS
MATERIALS
REF. PART MATERIAL DESIGNATION
N° EUROPE USA
1
Upper bracket Cast iron EN-GJL-200 Class 25 B
2
Spacer Cast iron EN-GJL-200 Class 25 B
3
Filling plug + OR Stainless steel+NBR EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316
4
Vent valve Stainless steel EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316
5
Cable EPR
Cable gland plate
6 Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI304
Cable gland
7 EPDM
8
Shaft end Stainless steel EN 10088-1-X20Cr13 (1.4021) AISI420
9
Removable sand guard EPDM
10
Mechanical seal cover Stainless steel EN 10213-4-GX5CrNi19-10 (1.4308) ASTM CF-8 (AISI 304 cast)
11
Mechanical seal Carbon graphite / Aluminium oxide
12
Bush bearings Carbon graphite
13
Elastomers NBR
14
Motor sleeve Stainless steel EN 10088-1-X2CrNi19-11 (1.4306) AISI304L
15
Lower bracket Cast iron EN-GJL-200 Class 25 B
Thrust bearing bracket
16 Cast iron EN-GJL-200 Class 25 B
17
Diaphragm EPDM
18
Lower cover Cast iron EN-GJL-200 Class 25 B
19
Bolts and screws Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI304
MOTORI SERIE L6WN:
Cooling liquid TABELLA MATERIALI
Water + antifreeze
L6WN TABLE OF MA
TABLE TERIALS
MATERIALS L6w-2p50-en_b_tm
37
L6W MOTOR SERIES
IDENTIFICATION CODE
IDENTIFICATION
L6W 110 T 40 5 /_ HT
HIGH TEMPERATURE
VERSION
5 = 50 Hz
6 = 60 Hz
RATED VOLTAGE
T = THREE-PHASE
RATED POWER IN kW x 10
L6W (CAST IRON STANDARD VERSION)
L6WN (AISI 316 VERSION)
L6WR (DUPLEX VERSION)
EXAMPLE : L6W110T405/A HT
L6W MOTOR :
RATED POWER 11 kW; THREE-PHASE;
RATED VOLTAGE 400 V; 50 Hz; /A VERSION; HIGH TEMPERATURE
RATING PLA
RATING TE
PLATE
LEGEND
1 - Motor type 7 - Weight
2 - Code 8 - Maximum immersion depht
3 - Maximum water temperature 9 - Operating characteristics
4 - Minimum water velocity 10 - Production date
5 - Insulation class 11 - Serial number
6 - Protection class 12 - Characteristics at service factor
38
L6W MOTOR SERIES
DIMENSIONS AND WEIGHTS AT 50 Hz
AT
39
L6W MOTOR SERIES
CARATTERISTICHE DI FUNZIONAMENTO A 50 Hz
THREE-PHASE OPERA TING CHARACTERISTIC
OPERATING CHARACTERISTICSS AT 50 Hz
AT
MOTOR RATED RATED OPERATING CHARACTERISTICS DIRECT MAX CABLE TYPE
TYPE POWER VOLTAGE AT RATED POWER START WATER
RATED TEMPERATURE
THREE-PHASE CURRENT Sec. (mm2)
kW HP V A rpm η% cosϕ Ts/Tn* Is/In °C DOL Y/D L (m)
380 9,89 2835 68,1 0,9 1,00 3,56
L6W40T405 4 5,5 400 9,26 2865 71,0 0,88 1,13 4,00 30 4 - 4
415 9,13 2880 71,5 0,85 1,21 4,20
380 12,7 2855 75,4 0,88 1,18 4,37
L6W55T405 5,5 7,5 400 12,4 2875 75,7 0,85 1,31 4,70 30 4 4 4
415 12,5 2885 75,4 0,82 1,42 4,85
380 17,0 2840 74,9 0,9 1,26 4,34
L6W75T405 7,5 10 400 16,4 2860 76,0 0,87 1,41 4,74 30 4 4 4
415 16,2 2875 76,5 0,84 1,52 4,96
380 20,5 2840 77,6 0,89 1,51 4,64
L6W93T405 9,3 12,5 400 20,0 2860 78,2 0,86 1,68 5,01 30 4 4 4
415 19,9 2870 78,3 0,83 1,81 5,21
380 24,2 2830 77,2 0,9 1,44 4,38
L6W110T405 11 15 400 23,5 2850 78,0 0,87 1,47 4,75 30 4 4 4
415 23,4 2865 78,0 0,84 1,73 4,94
380 28,1 2830 77,9 0,9 1,31 4,53
L6W130T405 13 17,5 400 27,1 2855 78,9 0,88 1,47 4,93 30 4 4 4
415 27,0 2865 79,1 0,9 1,59 5,15
380 32,1 2830 80,2 0,88 1,55 4,88
L6W150T405 15 20 400 31,5 2855 80,6 0,85 1,72 5,25 30 4 4 4
415 31,3 2865 80,9 0,82 1,86 5,46
380 38,5 2845 81,8 0,89 1,77 5,23
L6W185T405 18,5 25 400 37,6 2860 82,4 0,86 1,97 5,65 30 6 4 4
415 37,5 2870 82,4 0,83 2,13 5,86
380 47,3 2865 81,7 0,87 0,86 4,60
L6W220T405 22 30 400 46,5 2880 82,2 0,83 0,96 4,93 30 6 4 4
415 46,7 2890 82,2 0,8 1,04 5,09
380 56,5 2860 81,9 0,85 1,58 4,82
L6W260T405 26 35 400 55,4 2880 82,7 0,82 1,76 5,18 30 6 4 4
415 55,7 2890 82,7 0,79 1,90 5,35
380 63,8 2870 82,3 0,87 1,07 4,94
L6W300T405 30 40 400 62,3 2890 83,1 0,84 1,19 5,32 30 10 4 4
415 62,0 2900 83,3 0,81 1,29 5,55
380 81,8 2845 79,6 0,86 1,03 4,25
L6W370T405 37 50 400 79,1 2870 81,2 0,83 1,15 4,63 30 10 4 4
415 79,4 2880 80,8 0,80 1,25 4,79
* Ts/Tn = ratio between starting torque and nominal torque. l6w-2p50-en_f_te
40
L6W HT MOTOR SERIES
CARATTERISTICHE DI FUNZIONAMENTO A 50 Hz
THREE-PHASE OPERA TING CHARACTERISTIC
OPERATING CHARACTERISTICSS AT 50 Hz
AT
MOTOR RATED RATED OPERATING CHARACTERISTICS DIRECT MAX CABLE TYPE
TYPE POWER VOLTAGE AT RATED POWER START WATER
RATED TEMPERATURE
THREE-PHASE CURRENT Sec. (mm2)
kW HP V A rpm η% cosϕ Ts/Tn* Is/In °C DOL Y/D L (m)
380 9,81 2905 76,9 0,81 1,65 5,65
L6W40T405 HT 4 5,5 400 10,1 2915 75,5 0,76 1,83 5,78 45 4 4 4
415 10,5 2920 74,2 0,72 1,98 5,77
380 12,9 2895 77,1 0,84 1,75 5,71
L6W55T405 HT 5,5 7,5 400 13,0 2905 77,0 0,79 1..95 5,96 45 4 4 4
415 13,4 2915 76,3 0,75 2,10 6,03
380 16,9 2880 79,2 0,85 1,89 5,64
L6W75T405 HT 7,5 10 400 16,9 2890 79,0 0,81 2,11 5,91 45 4 4 4
415 17,3 2900 78,3 0,77 2,27 6,00
380 20,6 2865 79,2 0,87 1,72 5,13
L6W93T405 HT 9,3 12,5 400 20,4 2880 79,3 0,83 1,82 5,44 45 4 4 4
415 20,8 2890 78,4 0,79 2,07 5,53
380 23,8 2870 80,1 0,88 1,57 5,35
L6W110T405 HT 11 15 400 23,6 2885 80,1 0,84 1,75 5,69 45 4 4 4
415 23,9 2890 79,8 0,80 1,89 5,83
380 28,3 2860 81,8 0,85 1,80 5,55
L6W130T405 HT 13 17,5 400 28,1 2875 81,4 0,82 2,01 5,87 45 4 4 4
415 28,4 2885 81,4 0,78 2,17 6,03
380 31,8 2880 83,6 0,86 2,21 6,33
L6W150T405 HT 15 20 400 31,9 2890 83,4 0,82 2,46 6,65 45 6 4 4
415 32,5 2900 82,8 0,78 2,65 6,77
380 40,3 2895 83,9 0,83 1,04 5,40
L6W185T405 HT 18,5 25 400 40,5 2905 83,5 0,79 1,15 5,65 45 6 4 4
415 41,6 2910 83,0 0,75 1,24 5,71
380 48,5 2890 83,6 0,82 1,89 5,62
L6W220T405 HT 22 30 400 48,6 2905 83,6 0,78 2,10 5,90 45 6 4 4
415 49,7 2910 83,2 0,74 2,26 5,99
380 55,7 2895 83,8 0,85 1,24 5,66
L6W260T405 HT 26 35 400 55,2 2905 84,0 0,81 1,38 6,00 45 10 4 4
415 55,8 2915 83,9 0,77 1,49 6,17
380 67,1 2885 82,2 0,83 1,29 5,18
L6W300T405 HT 30 40 400 67,1 2900 82,8 0,78 1,44 5,46 45 10 4 4
415 68,8 2910 81,8 0,74 1,55 5,52
* Ts/Tn = ratio between starting torque and nominal torque. l6w-ht-2p50-en_c_te
41
42
8” Water filled submersible motors.
Submersible The robust design together with excellent choise of materials
ensures optimal performance, ease of installation and reliability
motors
in all applications. For extremely demanding operation as high
water temperature or aggressive environments special versions
are available.
L8W
Series
SPECIFICATIONS
SPECIFICATIONS SPECIAL VERSIONS
• Stainless steel outer sleeve. • Motors with double cable outlet for
• Shaft extension and coupling star/delta start.
dimensions to NEMA standards. • L8WN series
series: complete range
• Rewindable stator stator. available realized of AISI 316
• Class Y insulation
insulation. stainless steel.
• Protection class: IP68
IP68. • L8WR series
series: complete range
• Compensating bellows for internal available realized of Duplex
liquid expansion. stainless steel.
• Axial load supported by Kingsbury • HT series
series: complete range
type thrust bearing. available for all the L8W/N/R
• Mechanical seal construction, realized for applications
protected by sand guard. in high temperature environments
• Maximum immersion depth depth: up to 60°C
(up 60°C) or under inverter.
350 m.
• Maximum number of starts per OPTIONAL FEATURES
FEATURES
hour at regular intervals: 10. • Silicon Carbide mechanical seal.
• Maximum supply voltage • Special voltages.
variations allowed : ±10%.
• Maximum water temperature
temperature: ACCES SORIES
ACCESSORIES
30°C. • Temperature sensor PT 100 / PTC
PTC.
Max. temperature applies to motors
working in a installation capable of
delivering a flow of water around the
motor jacket of at least 0,5 m/s.
• Axial thrust
thrust:
50000 N from 30 to 93 kW.
• Power supply cable suitable
for drinkable water.
• Versions
ersions:
- Three-phase:
30 to 93 kW 380-415 V, 50 Hz.
• Horizontal operation
operation:
valid for all versions provided that the
direction of the axial thrust generated
by the impellers is always from the
Rewindable
pump to the motor.
stator
Thrust bearing
Kingsbury
type
Mechanical
seal
43
L8W - L8WN - L8WR MOTOR SERIES
MOTOR CROS S SECTION
CROSS
44
L8W MOTOR SERIES: TABLE OF MATERIALS
L8W T ABLE OF MA
TABLE TERIALS
MATERIALS
REF. PART MATERIAL DESIGNATION
N° EUROPE USA
1Upper bracket Cast iron EN-GJL-200 Class 25 B
2Spacer Cast iron EN-GJL-200 Class 25 B
3Filling plug + OR Stainless steel+NBR EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316
4Vent valve Stainless steel EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316
5Cable EPR
6Cable gland plate Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI304
7Cable gland EPDM
8Shaft end Duplex stainless steel EN 10088-1-X2CrNiMoN22-5-3 (1.4462) A276/A790-S31803
9Removable sand guard Stainless steel EN 10088-1-X2CrNiMo17-12-2 (1.4404) AISI 316L
10Mechanical seal cover Stainless steel EN 10088-1-X2CrNiMo17-12-2 (1.4404) AISI 316L
11Mechanical seal Carbon graphite / Aluminium oxide
12Bush bearings Carbon graphite
13Elastomers NBR
14Motor sleeve Stainless steel EN 10088-1-X2CrNi19-11 (1.4306) AISI304L
15Lower bracket Cast iron EN-GJL-200 Class 25 B
16Thrust bearing bracket Cast iron EN-GJL-200 Class 25 B
17Filling valve Stainless steel EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316
18Diaphragm EPDM
19Lower cover Cast iron EN-GJL-200 Class 25 B
20Bolts and screws Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI304
L8WN
CoolingMOTOR
liquid SERIES:
WaterTABLE OF MATERIALS
+ antifreeze
L8WN TABLE OF MA
TABLE TERIALS
MATERIALS L8w-2p50-en_a_tm
45
L8W MOTOR SERIES
IDENTIFICATION CODE
IDENTIFICATION
L8W 550 T 40 5 /_ HT
HIGH TEMPERATURE
VERSION
5 = 50 Hz
6 = 60 Hz
RATED VOLTAGE
T = THREE-PHASE
RATED POWER IN kW x 10
L8W (CAST IRON STANDARD VERSION)
L8WN (AISI 316 VERSION)
L8WR (DUPLEX VERSION)
EXAMPLE : L8W550T405/A HT
L8W MOTOR :
RATED POWER 55 kW; THREE-PHASE;
RATED VOLTAGE 400 V; 50 Hz; /A VERSION; HIGH TEMPERATURE
RATING PLA
RATING TE
PLATE
LEGEND
1 - Motor type 7 - Weight
2 - Code 8 - Maximum immersion depht
3 - Maximum water temperature 9 - Operating characteristics
4 - Minimum water velocity 10 - Production date
5 - Insulation class 11 - Serial number
6 - Protection class 12 - Characteristics at service factor
46
L8W MOTOR SERIES
DIMENSIONS AND WEIGHTS AT 50 Hz
AT
47
L8W MOTOR SERIES
CARATTERISTICHE DI FUNZIONAMENTO A 50 Hz
THREE-PHASE OPERA TING CHARACTERISTIC
OPERATING CHARACTERISTICSS AT 50 Hz
AT
MOTOR RATED RATED OPERATING CHARACTERISTICS DIRECT MAX CABLE TYPE
TYPE POWER VOLTAGE AT RATED POWER START WATER
RATED TEMPERATURE
2
THREE-PHASE CURRENT Sec. (mm )
kW HP V A rpm η% cosϕ Ts/Tn* Is/In °C DOL Y/D L (m)
380 65,0 2905 83,0 0,85 1,20 4,67
L8W300T405 30 40 400 62,0 2900 83,0 0,84 1,15 4,69 30 10 6 5,5
415 59,0 2900 83,0 0,84 1,09 4,70
380 81,0 2840 80,5 0,87 1,04 4,19
L8W370T405 37 50 400 78,5 2860 81,0 0,84 1,14 4,54 30 10 6 5,5
415 76,0 2870 81,5 0,83 1,23 4,88
380 92,0 2850 82,0 0,87 0,92 3,72
L8W450T405 45 60 400 89,0 2870 82,0 0,85 1,01 3,98 30 16 6 5,5
415 89,0 2880 83,5 0,83 1,09 4,23
380 110 2840 82,0 0,86 1,14 3,90
L8W520T405 52 70 400 108 2865 82,0 0,85 1,15 4,20 30 16 6 5,5
415 104 2885 82,5 0,82 1,16 4,50
380 118 2840 82,0 0,87 1,26 3,57
L8W550T405 55 75 400 114 2870 82,0 0,85 1,27 3,88 30 16 10 5,5
415 110 2885 82,5 0,83 1,27 4,19
380 124 2855 82,0 0,87 1,12 4,18
L8W600T405 60 80 400 120 2875 82,5 0,85 1,23 4,49 30 16 10 5,5
415 118 2885 83,5 0,83 1,33 4,80
380 138 2850 82,5 0,88 0,98 4,22
L8W670T405 67 90 400 133 2870 83,0 0,86 1,07 4,52 30 25 10 5,5
415 132 2885 83,5 0,83 1,16 4,82
380 156 2860 82,0 0,87 0,92 4,10
L8W750T405 75 100 400 152 2875 82,5 0,85 1,01 4,41 30 25 16 5,5
415 148 2885 83,0 0,82 1,10 4,72
380 172 2860 83,0 0,87 0,91 4,12
L8W830T405 83 110 400 168 2870 83,5 0,84 1,00 4,39 30 35 16 5,5
415 163 2880 84,0 0,82 1,08 4,66
380 192 2850 83,0 0,87 0,84 3,38
L8W930T405 93 125 400 186 2860 83,5 0,85 0,92 3,84 30 35 16 5,5
415 180 2885 84,0 0,83 1,00 4,30
* Ts/Tn = ratio between starting torque and nominal torque. l8w-2p50-en_d_te
48
L8W HT MOTOR SERIES
CARATTERISTICHE DI FUNZIONAMENTO L8W HT A 50 Hz
THREE-PHASE OPERA TING CHARACTERISTIC
OPERATING CHARACTERISTICS S AT 50 Hz
AT
MOTOR RATED RATED OPERATING CHARACTERISTICS DIRECT MAX CABLE TYPE
TYPE POWER VOLTAGE AT RATED POWER START WATER
RATED TEMPERATURE
2
THREE-PHASE CURRENT Sec. (mm )
kW HP V A rpm η% cosϕ Ts/Tn* Is/In °C DOL Y/D L (m)
380 66,6 2865 82,5 0,84 1,29 5,10
L8W300T405 HT 30 40 400 64,5 2885 83,0 0,81 1,41 5,52 45 10 6 5,5
415 62,4 2895 83,5 0,8 1,53 5,94
380 77,5 2865 84,0 0,86 1,12 4,41
L8W370T405 HT 37 50 400 75,0 2885 84,0 0,84 1,23 4,72 45 16 6 5,5
415 75,0 2895 85,5 0,82 1,33 5,02
380 97,8 2860 83,0 0,83 1,33 4,39
L8W450T405 HT 45 60 400 96,0 2885 83,0 0,82 1,34 4,73 45 16 6 5,5
415 92,4 2905 83,5 0,79 1,35 5,06
380 110 2835 83,0 0,86 1,33 3,84
L8W520T405 HT 52 70 400 106 2865 83,0 0,84 1,34 4,17 45 16 10 5,5
415 102 2880 83,5 0,82 1,34 4,51
380 117 2865 83,5 0,86 1,23 4,44
L8W550T405 HT 55 75 400 113 2885 84,0 0,84 1,34 4,77 45 16 10 5,5
415 111 2895 85,0 0,82 1,46 5,10
380 127 2860 83,5 0,87 1,10 4,60
L8W600T405 HT 60 80 400 122 2880 84,0 0,85 1,20 4,93 45 25 10 5,5
415 121 2895 84,5 0,82 1,30 5,25
380 141 2870 82,5 0,85 1,03 4,55
L8W670T405 HT 67 90 400 137 2885 83,0 0,83 1,13 4,89 45 25 16 5,5
415 133 2895 83,5 0,8 1,24 5,24
380 156 2905 82,5 0,86 1,02 4,55
L8W750T405 HT 75 100 400 152 2915 83,0 0,83 1,12 4,85 45 35 16 5,5
415 147 2925 83,5 0,81 1,21 5,15
380 171 2875 84,5 0,86 0,95 3,79
L8W830T405 HT 83 110 400 166 2885 85,0 0,84 1,04 4,30 45 35 16 5,5
415 161 2910 85,5 0,82 1,13 4,82
* Ts/Tn = ratio between starting torque and nominal torque. l8w-ht-2p50-en_a_te
49
50
10” Water filled submersible motors.
Submersible The robust design together with excellent choise of materials
ensures optimal performance, ease of installation and reliability
motors
in all applications. For extremely demanding operation as high
water temperature or aggressive environments special versions
are available.
L10W
Series
SPECIFICATIONS
SPECIFICATIONS SPECIAL VERSIONS
• Stainless steel outer sleeve. • Motors with double cable outlet for
• Rewindable stator stator. star/delta start.
• Class Y insulation
insulation. • L10WN series
series: complete range
• Protection class: IP68
IP68. available realized of AISI 316
• Compensating bellows for internal stainless steel.
liquid expansion. • L10WR series
series: complete range
• Axial load supported by Kingsbury available realized of Duplex
type thrust bearing. stainless steel.
• Mechanical seal • HT series
series: complete range
protected by sand guard. available for all the L10W/N/R
• Maximum immersion depth depth: construction, realized for applications
350 m. in high temperature environments
• Maximum number of starts per up to 60°C
(up 60°C) or under inverter.
hour at regular intervals: 8.
• Maximum supply voltage
OPTIONAL FEATURES
FEATURES
variations allowed : ±10%.
• Silicon Carbide mechanical seal.
• Maximum water temperature
temperature:
• Special voltages.
30°C.
Max. temperature applies to motors
ACCES SORIES
ACCESSORIES
working in a installation capable of
• Temperature sensor PT 100 / PTC
PTC.
delivering a flow of water around the
motor jacket of at least 0,5 m/s.
• Axial thrust
thrust:
65000 N from 93 to150 kW.
• Power supply cable suitable
for drinkable water.
• Versions
ersions:
- Three-phase:
93 to 150 kW 380-415 V, 50 Hz.
• Horizontal operation
operation:
valid for all versions provided that the
direction of the axial thrust generated
by the impellers is always from the
pump to the motor.
Rewindable
stator
Thrust bearing
Kingsbury
type
Mechanical
seal
51
L10W - L10WN - L10WR MOTOR SERIES
MOTOR CROS S SECTION
CROSS
52
L10W MOTOR SERIES: TABLE OF MATERIALS
L10W T ABLE OF MA
TABLE TERIALS
MATERIALS
REF. PART MATERIAL DESIGNATION
N° EUROPE USA
1 Upper bracket Cast iron EN-GJL-200 Class 25 B
2 Spacer Cast iron EN-GJL-200 Class 25 B
3 Filling plug + OR Stainless steel+NBR EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316
4 Vent valve Stainless steel EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316
5 Cable EPR
6 Cable gland plate Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI304
7 Cable gland EPDM
8 Shaft end Duplex stainless steel EN 10088-1-X2CrNiMoN22-5-3 (1.4462) A276/A790-S31803
9 Removable sand guard Stainless steel EN 10088-1-X2CrNiMo17-12-2 (1.4404) AISI 316L
10 Mechanical seal cover Stainless steel EN 10088-1-X2CrNiMo17-12-2 (1.4404) AISI 316L
11 Mechanical seal Carbon graphite / Aluminium oxide
12 Bush bearings Carbon graphite
13 Elastomers NBR
14 Motor sleeve Stainless steel EN 10088-1-X2CrNi19-11 (1.4306) AISI304L
15 Lower bracket Cast iron EN-GJL-200 Class 25 B
16 Thrust bearing bracket Cast iron EN-GJL-200 Class 25 B
17 Filling valve Stainless steel EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316
18 Diaphragm EPDM
19 Lower cover Cast iron EN-GJL-200 Class 25 B
20 Bolts and screws Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI304
L10WN
CoolingMOTOR
liquid SERIES:
Water + TABLE
antifreezeOF MATERIALS
L10WN TABLE OF MA
TABLE TERIALS
MATERIALS L10w-2p50-en_a_tm
53
L10W MOTOR SERIES
IDENTIFICATION CODE
IDENTIFICATION
L10W 1500 T 40 5 /_ HT
HIGH TEMPERATURE
VERSION
5 = 50 Hz
6 = 60 Hz
RATED VOLTAGE
T = THREE-PHASE
RATED POWER IN kW x 10
L10W (CAST IRON STANDARD VERSION)
L10WN (AISI 316 VERSION)
L10WR (DUPLEX VERSION)
EXAMPLE : L10W1500T405/A HT
L10W MOTOR :
RATED POWER 150 kW; THREE-PHASE;
RATED VOLTAGE 400 V; 50 Hz; /A VERSION; HIGH TEMPERATURE
RATING PLA
RATING TE
PLATE
LEGEND
1 - Motor type 7 - Weight
2 - Code 8 - Maximum immersion depht
3 - Maximum water temperature 9 - Operating characteristics
4 - Minimum water velocity 10 - Production date
5 - Insulation class 11 - Serial number
6 - Protection class 12 - Characteristics at service factor
54
L10W MOTOR SERIES
DIMENSIONS AND WEIGHTS AT 50 Hz
AT
55
L10W MOTOR SERIES
CARATTERISTICHE DI FUNZIONAMENTO A 50 Hz
THREE-PHASE OPERA TING CHARACTERISTIC
OPERATING CHARACTERISTICSS AT 50 Hz
AT
MOTOR RATED RATED OPERATING CHARACTERISTICS DIRECT MAX CABLE TYPE
TYPE POWER VOLTAGE AT RATED POWER START WATER
RATED TEMPERATURE
2
THREE-PHASE CURRENT Sec. (mm )
kW HP V A rpm η% cosϕ Ts/Tn* Is/In °C DOL Y/D L (m)
380 191 2895 83,0 0,87 1,02 5,14
L10W930T405 93 125 400 184 2910 83,0 0,85 1,12 5,55 30 35 25 5
415 180 2915 84,0 0,84 1,21 5,95
380 235 2900 83,5 0,86 1,20 4,77
L10W1100T405 110 150 400 225 2910 83,5 0,84 1,32 5,17 30 50 25 5
415 220 2920 84,5 0,82 1,43 5,57
380 270 2895 84,0 0,86 1,29 4,84
L10W1300T405 130 175 400 263 2915 83,0 0,85 1,42 5,22 30 50 25 5
415 255 2915 85,5 0,83 1,54 5,60
380 308 2905 83,0 0,86 1,26 4,77
L10W1500T405 150 200 400 295 2915 83,0 0,85 1,38 5,20 30 70 25 5
415 285 2925 84,0 0,84 1,50 5,63
* Ts/Tn = ratio between starting torque and nominal torque. l10w-2p50-en_b_te
56
ACCES SORIES
ACCESSORIES
62
Electrical Panels ..............................................................................................................................
57
ISO
ISO--THREADED FLANGES
Dimensions (mm)
PUMP THREADING
* Flange according to EN 1092-1
TYPE ISO 7-1
G DN PN ØD Ød ØK Z ØL C L1 I2 TYPE
125 10÷16 250 - 210 8 18 22 108 44 A
Z855 125 25÷40 270 188 220 8 26 26 168 44 C
Z875 125 63 295 188 240 8 30 34 188 44 C
R5
Z895 150 10÷16 285 - 240 8 22 22 248 44 B
Z8125 150 25÷40 300 218 250 8 26 28 315 44 D
150 63 345 218 280 8 33 36 335 44 D
* Flanges according to ASME B16.5 are available on request. z8-flange-en_a_td
58
CARRYING CLAMPS
NOTE. Two sets of clamps are necessary for the installation of one unit.
Material : EN 10027-1-S235JR (1.0038) painted.
59
L6C - L6W SERIES MOTORS
TABELLE INDICATIVE DI ABBINAMENTO MOTORE - QUADRO
MOTOR - CONTROL P ANEL COMBINA
PANEL TION T
COMBINATION ABLE
TABLE
MOTOR TYPE RATED RATED PANEL TYPE
L6C - 6" POWER CURRENT
THREE-PHASE 380-415 V
kW HP A QTD/… Q3D/… Q3I/… Q3A/… Q3Y/… Q3SF/…
4 5,5 11,0 …40-75 …40-75 …40-75 …40-75 …40-75 …75
5,5 7,5 14,6 …40-75 …40-75 …40-75 …40-75 …40-75 …75
7,5 10 18,3 …75-92 …75-92 …75-92 …75-92 …75-92 …150
9,3 12,5 22,8 - …92-110 …92-110 …92-110 …92-110 …150
11 15 26,0 - …110-150 …110-150 …110-150 …110-150 …150
15 20 34,2 - …150-185 …150-185 …150-185 …150-185 …220
18,5 25 42,0 - …185-220 …185-220 …185-220 …185-220 …220
22 30 47,5 - …185-220 …185-220 …185-220 …185-220 …300
30 40 63,5 - …300-370 …300-370 …300-370 …300-370 …370
37 50 80,0 - - …370-450 …370-450 …370-450 …450
60
L8W - L10W SERIES MOTORS
TABELLA ABBINAMENTO POMPA-QUADRO COMANDO
MOTOR - CONTROL P ANEL COMBINA
PANEL TION T
COMBINATION ABLE
TABLE
MOTOR TYPE RATED RATED PANEL TYPE
L8W - 8" POWER CURRENT
THREE-PHASE 380-415 V
kW HP A Q3D/… Q3I/… Q3A/… Q3SF/…
30 40 65 …300-370 …300-370 …300-370 …370
37 50 81 - …370-450 …370-450 …450
45 60 92 - …450-550 …450-550 …550
52 70 110 - …550-750 …550-750 …590
55 75 118 - …550-750 …550-750 …590
60 80 124 - …550-750 …550-750 …750
67 90 138 - …750-900 …750-900 …900
75 100 156 - …750-900 …750-900 …900
83 110 172 - …750-900 …750-900 …900
93 125 192 - …900-1100 …900-1100 …1100
MOTOR TYPE 30 40 66,6 …300-370 …300-370 …300-370 …370
L8W HT - 8" 37 50 77,5 - …370-450 …370-450 …450
THREE-PHASE 45 60 97,8 - …450-550 …450-550 …550
52 70 110 - …550-750 …550-750 …590
55 75 117 - …550-750 …550-750 …590
60 80 127 - …550-750 …550-750 …750
67 90 141 - …750-900 …750-900 …900
75 100 156 - …750-900 …750-900 …900
83 110 171 - …750-900 …750-900 …900
61
Three-phase APPLICATIONS
APPLICATIONS
Electric • Protection and control of a three-phase surface or
submersible electric pump.
Panel
A C
0
1
LINEA
POWER
B
TERMICO
OVERLOAD
SERIE QTD
62
Three-phase APPLICATIONS
APPLICATIONS
Electric • Protection and control of a three-phase surface or
submersible electric pump.
Panel
• Metal enclosure.
• Power, pump running, thermal
overload and dry running indicator V 300
500
L1-L2
L2-L3
L3-L1
A 150
200
lights.
50 0 25
0 0
M 0 A
SERIE Q3D
63
Three-phase APPLICATIONS
APPLICATIONS
Electric • Protection and control of a three-phase surface or
submersible electric pump.
Panel
SPECIFICATIONS
SPECIFICATIONS • Ready for installation of dry running
• Manual control through an control float or pressure switch
Auto/Man selector switch. (to be ordered separately).
Q3Y Series • Automatic control through an Can be equipped with electronic
external enable contact. protection module with electrodes.
• Supply voltage:
3 x 400 V ±10%. OPTIONAL
• Frequency: 50/60 Hz. ACCES SORIES
ACCESSORIES
• 24 V AC low voltage auxiliary circuit. • KSL series 24 V level kit.
• Power: 4 to 315 kW. Probe module for protection against
• Star-delta starting. dry running (set of three electrodes
• Short-circuit and overload protection. included in the supply).
• Protection class: IP54. • Float.
• Ambient temperature: -5 to +40 °C • Pressure switch.
(according to EN 60439-1). • VR3/SCA3 three-phase module for
• Maximum relative humidity: 50% at overvoltage protection (lightning
+40°C, provided that no condensation protector).
occurs (according to EN 60439-1). A C
• Wall mounted.
• Metal enclosure.
• Power, pump running, thermal V 500
A 200
L2-L3
L1-L2 L3-L1
50 0 25
0 0
lights.
M 0 A
SERIE Q3Y
64
Three-phase APPLICATIONS
APPLICATIONS
Electric • Protection and control of a three-phase surface or
submersible electric pump.
Panel
SPECIFICATIONS
SPECIFICATIONS • Ready for installation of dry running
• Manual control through an control float or pressure switch
Auto/Man selector switch. (to be ordered separately).
Q3I Series • Automatic control through an Can be equipped with electronic
external enable contact. protection module with electrodes.
• Supply voltage:
3 x 400 V ±10%. OPTIONAL
• Frequency: 50/60 Hz. ACCES SORIES
ACCESSORIES
• 24 V AC low voltage auxiliary circuit. • KSL series 24 V level kit.
• Power: 4 to 315 kW. Probe module for protection against
• Impedance start. dry running (set of three electrodes
• Short-circuit and overload protection. included in the supply).
• Protection class: IP54. • Float.
• Ambient temperature: -5 to +40 °C • Pressure switch.
(according to EN 60439-1). • VR3/SCA3 three-phase module for
• Maximum relative humidity: 50% at overvoltage protection (lightning
+40°C, provided that no condensation protector).
occurs (according to EN 60439-1). A C
• Wall mounted.
• Metal enclosure.
• Power, pump running, thermal V 500
A 200
L2-L3
L1-L2 L3-L1
50 0 25
0 0
lights.
M 0 A
SERIE Q3I
65
Three-phase APPLICATIONS
APPLICATIONS
Electric • Protection and control of a three-phase surface or
submersible electric pump.
Panel
SPECIFICATIONS
SPECIFICATIONS • Ready for installation of dry running
• Manual control through an control float or pressure switch
Auto/Man selector switch. (to be ordered separately).
Q3A Series • Automatic control through an Can be equipped with electronic
external enable contact. protection module with electrodes.
• Supply voltage:
3 x 400 V ±10%. OPTIONAL
• Frequency: 50/60 Hz. ACCES SORIES
ACCESSORIES
• 24 V AC low voltage auxiliary circuit. • KSL series 24 V level kit.
• Power: 4 to 315 kW. Probe module for protection against
• Starting autotransformer. dry running (set of three electrodes
• Short-circuit and overload protection. included in the supply).
• Protection class: IP54. • Float.
• Ambient temperature: -5 to +40 °C • Pressure switch.
(according to EN 60439-1). • VR3/SCA3 three-phase module for
• Maximum relative humidity: 50% at overvoltage protection (lightning
+40°C, provided that no condensation protector).
occurs (according to EN 60439-1). A C
• Wall mounted.
• Metal enclosure.
• Power, pump running, thermal V 500
A 200
L2-L3
L1-L2 L3-L1
50 0 25
0 0
lights.
M 0 A
SERIE Q3A
66
Three-phase APPLICATIONS
APPLICATIONS
Electric • Protection and control of a three-phase surface or
submersible electric pump.
Panel SPECIFICATIONS
SPECIFICATIONS Protections against phase failure /
• Manual control through an phase sequence / frequency out of
Auto/Man selector switch. limits on power supply line.
• Automatic control through an Low-voltage protection on auxiliary
external enable contact. circuits.
Q3SF Series • Supply voltage: Protection against starter
3 x 400 V ±10%. overtemperature / overload /
• Frequency: 50/60 Hz. malfunction.
• 24 V AC low voltage auxiliary circuit. Protection against overload / locked
• Power: 5,5 to 110 kW. rotor / current asymmetry on motor
• Softstart with torque control. side.
• Protection class: IP54. Short-circuit protection on inputs
• Ambient temperature: -5 to +40 °C and outputs.
• Maximum relative humidity: 50% at RS232 interface for remote control
+40°C, provided that no condensation and RS485 for use of remote
occurs (according to EN 60439-1). keypanel.
• Wall mounted. Incorporated by-pass contactor.
• Metal enclosure.
• Dry running indicator light. OPTIONAL
• Power - pump running - malfunction ACCES SORIES
ACCESSORIES
LEDs on starter keypanel. • KSL series 24 V level kit.
• ON/OFF selector switch for activation Probe module for protection against
of by-pass contactor. dry running (set of three electrodes
• Ready for installation of dry running included in the supply).
control float or pressure switch • Float.
(to be ordered separately). • Pressure switch.
Can be equipped with electronic • VR3/SCA3 three-phase module for
protection module with electrodes. overvoltage protection (lightning
protector).
A C
STATIC ST
STA ARTER
STARTER
CHARACTERISTIC
CHARACTERISTICSS
• Static starter for gradual start-up/ M 0 A
shutdown, featuring:
keypanel with liquid crystal display
showing voltage, absorbed current,
cos ϕ, operating hours, number of
B
SERIE Q3SF
67
Level APPLICATIONS
APPLICATIONS
Control • Accessory for electric pump control panels, suitable for tank
filling or drainage applications or for activation of audible
Panel
or visual alarms.
A C
B
Control box
SERIE QCL5
68
Kit APPLICATIONS
APPLICATIONS
24 V Level • Accessory for electric panels.
Probe
SERIE SLD
QSCS-QM-QTD-Q3D-Q3Y-
KIT KSL/24 1x24 50/60 Hz 3,5 N0-C-NC 250 8 90 x 36 x 60 0,5
Q3A-Q3I-Q3SF
CB-SLD-en_b_te
69
Lightning APPLICATIONS
APPLICATIONS
Protection • Accessory for electric panels.
DPF Series
SPECIFICATIONS
SPECIFICATIONS
• Varistor for overvoltage protection of
single-phase lines. To be connected
between the phase and neutral
conductor.
• Operating voltage: 460 V AC.
• Maximum varistor voltage: 750 V
with 100 A peak current.
VR Series
SPECIFICATIONS
SPECIFICATIONS
• Varistors for overvoltage protection of
three-phase lines.
• To be connected between the phases
(VR3 model).
• Operating voltage: 460 V AC.
• Maximum varistor voltage: 750 V
with 100 A peak current.
• Designed for installation on Lowara
electric panels featuring DIN bar.
SCA3 Series
SPECIFICATIONS
SPECIFICATIONS
• Lightning arresters for overvoltage
protection of three-phase lines. To
be connected between the phases
and the heart conductor,
• Operating voltage: 500 V AC.
• Maximum varistor voltage: 2,5 kW
with 40 kA peak current.
• Designed for installation on Lowara
electric panels featuring DIN bar.
SERIE VR
70
COOLING SHROUDS
71
COOLING SHROUDS
Z8 PUMP SERIES
DIMENSIONI E CODICI KIT RAFFREDDAMENTO
6”, 8” and 10” MOTORS COMBINA TION T
COMBINATION ABLE
TABLE
PUMP MOTOR COOLING COOLING COOLING
TYPE TYPE SET SET SET
L6C L6W L8W L10W SHROUD FILTER BRACKETS
(D x L) (D x L1) (D)
5,5 5,5
7,5 7,5
9,3 9,3 D225X1000 D225X192 D225 - 2PZ
11 11
- 13
Z855
15 15
Z875
18,5 18,5 D225X1250 D225X192 D225 - 2PZ
22 22
- 26
30 30 D225X1500 D225X192 D225 - 3PZ
37 37
7,5 7,5
11 11 D256X1000 D256X325 D256 - 2PZ
- 13
15 15
Z895
18,5 18,5 D256X1250 D256X325 D256 - 2PZ
Z8125
22 22
- 26
30 30 D256X1500 D256X325 D256 - 3PZ
37 37
30
37
45 D256X1500 D256X325 D256 - 3PZ
52
Z855 55
Z875 60
67 D256X1750 D256X325 D256 - 3PZ
75
83
D256X2000 D256X325 D256 - 3PZ
93
30
37
45 D285X1500 D285X385 D285 - 3PZ
52
Z895 55
Z8125 60
67 D285X1750 D285X385 D285 - 3PZ
75
83
D285X2000 D285X385 D285 - 3PZ
93
93
Z855 110
D285X2250 D285X385 D285 - 3PZ
Z875 130
150
93
Z895 110
D330X2250 D330X385 D330 - 3PZ
Z8125 130
150
Z8_kit-raf50-en_b_ta
72
TECHNICAL
APPENDIX
73
SUBMERSIBLE ELECTRIC PUMP INSTALLA
INSTALLATION DIAGRAM
ALLATION
RECOMMENDATIONS
RECOMMENDATIONS
• Secure the drop cable to the pipe every 2÷3 meters of
piping.
• Make sure the electric pump is installed at a safe
distance from the bottom of the well.
• Make sure there is a minimum distance of 3 mm
between the diameter of the pump and the internal
diameter of the well.
• During operation, make sure that the water circulation
speed around the motor is at least 8 cm/sec.
• Make sure that the minimum dynamic level of the water
in the well is at least 1 m above the pump’s delivery port.
TECHNICAL APPENDIX 74
EXAMPLE OF INSTALLA
INSTALLATION OF A SUBMERSIBLE ELECTRIC
ALLATION
PUMP CONTROLLED B Y AN INVERTER (HYDRO
BY VAR®)
(HYDROV
75 TECHNICAL APPENDIX
L6C SERIES MOTORS
L6C MOTOR SERIES
TABLE OF POWER REDUCTION COEFFICIENTS WITH INCREASED WATER TEMPERATURE
TYPE POWER °C
kW 35 40 45 50 55 60
TYPE POWER °C
kW 25 30 35 40 45 50 55 60
EXAMPLE:
A 15 kW L6W motor is to be used in 35°C water.
Motor power at 35 °C = 15 x 0,75 = 11,25 kW
TECHNICAL APPENDIX 76
SELECTING CABLE CROS S-SECTIONS FOR SUBMERSIBLE
CROSS-SECTIONS
MOTORS
To select the cross-section of power cables for submersible pumps, consult the tables shown below. In these tables,
the maximum lenghts of the power cable for each cross-section are shown for each motor and next to the various
input voltage ratings.
Therefore, to find the required cable cross-section, simply read off the maximum permitted lenghts for each cross-
section next to the selected motor and required input voltage.
E.g.:
A 120 m long power cable must be matched with a 230V L4C07M235 motor.
To determine the cross-section of the cable, simply move along the row of the 230V motor until you find the maximum
lenght of 120 m or immediately above it and then read off the corresponding cross-section in that column.
In this case, the 4 mm2 cable is selected.
N.B.: the tables include specific data (current and power factor) for each motor and voltage rating based on a
maximum voltage drop of 4% (HD 384.5), a maximum cable temperature of 90°C, water installation similar to air
installation at a temperature of 30°C.
TYPE OF CABLES
CABLE TYPES
THREE CORE FLAT FOUR CORE FLAT SINGLE CORE ROUND FOUR CORE ROUND
SECTION Hmin Lmin Hmax Lmax Weight Hmin Lmin Hmax Lmax Weight Dmin Dmax Weight Dmin Dmax Weight
2
mm mm mm mm mm kg/km mm mm mm mm kg/km mm mm kg/km mm mm kg/km
4 8 19,2 9 20,8 250 8 25,2 9 26,8 395 6,5 7,5 92 14 16,1 360
6 8 19,2 9 20,8 325 8 25,2 9 26,8 470 7,4 8 118 15,7 18 475
10 8 19,2 9 20,8 535 8 25,2 9 26,8 710 8,6 10 183 20,9 23,9 836
16 - - - - - - - - - - 9,6 11 251 23,8 27,1 1145
25 - - - - - - - - - - 11 13 362 28,9 32,9 1716
35 - - - - - - - - - - 12,5 14,5 497 - - -
50 - - - - - - - - - - 15 17 669 - - -
70 - - - - - - - - - - 17,5 19,5 901 - - -
95 - - - - - - - - - - 20,5 22,5 1141 - - -
120 - - - - - - - - - - 22 24,4 1435 - - -
150 - - - - - - - - - - 25,2 28,3 1795 - - -
185 - - - - - - - - - - 27,6 31 2156 - - -
240 - - - - - - - - - - 30,6 34,5 2760 - - -
L-cavi-en_a_td
77 TECHNICAL APPENDIX
L6C, 50 Hz: SIZING OF ETHYLENE-PROPILENE (EPR) CABLES
DOL (DIRECT ON LINE) ST ARTING
STARTING
2
Cable cross section: 4G x …mm
MOTOR RATED RATED Cos ϕ RATED VOLTAGE mm 2
4 6 10 16 25 35 50 70
TYPE POWER VOLTAGE CURRENT DROP A max 42 54 75 100 127 158 192 246
THREE-PHASE Kw HP V A % Maximum lenght in metres
220 0,80 17,8
L6C40T235 4 5,5 230 0,75 18,4 65 99 171 268 406 559
240 0,70 19,1
220 0,80 24,1
L6C55T235 5,5 7,5 230 0,75 24,2 47 72 125 197 300 413 572
240 0,71 25,3
220 0,82 30,5
L6C75T235 7,5 10 230 0,78 31,2 34 54 95 151 231 320 444
240 0,73 31,7
220 0,82 37,6
L6C93T235 9,3 12,5 230 0,80 38,1 26 42 76 121 186 258 359 489
240 0,79 39,5
220 0,87 43,3
L6C110T235 11 15 230 0,82 44,2 - 33 61 99 153 214 299 412
240 0,79 45,0
220 0,84 58,0
L6C150T235 15 20 230 0,80 57,9 - - 44 73 115 161 226 311
240 0,76 59,2
220 0,83 70,1
L6C185T235 18,5 25 230 0,80 71,0 - - 35 59 94 133 187 257
240 0,73 72,7
220 0,88 82,3
L6C220T235 22 30 230 0,84 81,4 - - - 46 74 106 152 212
240 0,80 82,3
380 0,80 10,3
L6C40T405 4 5,5 400 0,75 10,6 201 301 517
415 0,70 11,0
4
380 0,80 13,9
L6C55T405 5,5 7,5 400 0,75 14,0 147 222 382
415 0,71 14,6
380 0,82 17,6
L6C75T405 7,5 10 400 0,78 18,0 112 169 293 459
415 0,73 18,3
380 0,82 21,7
L6C93T405 9,3 12,5 400 0,80 22,0 88 135 236 371 565
415 0,79 22,8
380 0,87 25,0
L6C110T405 11 15 400 0,82 25,5 71 110 193 305 466
415 0,79 26,0
380 0,84 33,5
L6C150T405 15 20 400 0,80 33,4 51 81 145 231 355 493
415 0,76 34,2
380 0,83 40,5
L6C185T405 18,5 25 400 0,80 41,0 - 65 119 191 294 409
415 0,73 42,0
380 0,88 47,5
L6C220T405 22 30 400 0,84 47,0 - 50 94 153 237 332 467
415 0,80 47,5
380 0,89 63,0
L6C300T405 30 40 400 0,85 61,5 - - 65 109 173 245 346 480
415 0,80 63,5
380 0,87 79,5
L6C370T405 37 50 400 0,84 79,3 - - - 84 135 193 274 381
415 0,80 80,0
Exposed cable laid at a temperature of 30°C, maximum conductor temperature of 90°C l6c-cavi-50-en_f_te
TECHNICAL APPENDIX 78
L6C TRIFASE, 50 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EPR),
L6C, 50 Hz: SIZING OF ETHYLENE-PROPILENE (EPR) CABLES
Υ/
Υ/∆∆ (STAR / DEL
(STAR TA) ST
DELT ARTING
STARTING
Cable cross section: 4G x …mm2 + 3 x …mm2
MOTOR RATED RATED Cos ϕ RATED VOLTAGE mm
2
4 6 10 16 25 35 50 70
TYPE POWER VOLTAGE CURRENT DROP A max* 73 94 130 173 220 274 333 426
THREE-PHASE Kw HP V A % Maximum lenght in metres
380 0,80 10,3
L6C40T405 4 5,5 400 0,75 10,6 352 525
415 0,70 11,0
380 0,80 13,9
L6C55T405 5,5 7,5 400 0,75 14,0 259 388
415 0,71 14,6
380 0,82 17,6
L6C75T405 7,5 10 400 0,78 18,0 199 299 513
415 0,73 18,3
380 0,82 21,7
L6C93T405 9,3 12,5 400 0,80 22,0 160 241 415
415 0,79 22,8
380 0,87 25,0
L6C110T405 11 15 400 0,82 25,5 130 197 340 533
415 0,79 26,0
4
380 0,84 33,5
L6C150T405 15 20 400 0,80 33,4 98 150 260 408
415 0,76 34,2
380 0,83 40,5
L6C185T405 18,5 25 400 0,80 41,0 80 123 216 340 518
415 0,73 42,0
380 0,88 47,5
L6C220T405 22 30 400 0,84 47,0 63 98 173 274 421
415 0,80 47,5
380 0,89 63,0
L6C300T405 30 40 400 0,85 61,5 44 70 126 202 312 435
415 0,80 63,5
380 0,87 79,5
L6C370T405 37 50 400 0,84 79,3 - 53 99 160 248 347 487
415 0,80 80,0
Exposed cable laid at a temperature of 30°C, maximum conductor temperature of 90°C l6c-cavi-SD-50-en_b_te
79 TECHNICAL APPENDIX
L6W TRIFASE, 50 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EPR),
L6W
L6W,, 50 Hz: SIZING OF ETHYLENE-PROPILENE (EPR) CABLES
DOL (DIRECT ON LINE) ST ARTING
STARTING
Cable cross section: 4G x …mm2
MOTOR RATED RATED Cos ϕ RATED VOLTAGE mm2 4 6 10 16 25 35 50 70
TYPE POWER VOLTAGE CURRENT DROP A max 42 54 75 100 127 158 192 246
THREE-PHASE Kw HP V A % Maximum lenght in metres
380 0,90 9,89
L6W40T405 4 5,5 187 281 484
415 0,85 9,13
380 0,88 12,7
L6W55T405 5,5 7,5 148 222 384
415 0,82 12,5
380 0,90 17,0
L6W75T405 7,5 10 106 161 279 439
415 0,84 16,2
380 0,89 20,5
L6W93T405 9,3 12,5 87 133 233 366 561
415 0,83 19,9
380 0,90 24,2
L6W110T405 11 15 71 110 194 306 470
415 0,84 23,4
380 0,90 28,1
L6W130T405 13 17,5 60 93 165 262 403 561
415 0,85 27,0
4
380 0,88 32,1
L6W150T405 15 20 52 82 146 233 358 498
415 0,82 31,3
380 0,89 38,5
L6W185T405 18,5 25 - 65 118 190 294 410
415 0,83 37,5
380 0,87 47,3
L6W220T405 22 30 - 51 95,1 155 241 337 472
415 0,80 46,7
380 0,85 56,5
L6W260T405 26 35 - - 78 129 202 284 398
415 0,79 55,7
380 0,87 63,8
L6W300T405 30 40 - - 66 110 174 245 346 479
415 0,81 62,0
380 0,86 81,8
L6W370T405 37 50 - - - 82 132 188 267 372
415 0,80 79,4
L6W TRIFASE, 50 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRASl6w-cavi-50-en_c_te
07 (EPR),
Exposed cable laid at a temperature of 30°C, maximum conductor temperature of 90°C
L6W
L6W,, 50 Hz: SIZING OF ETHYLENE-PROPILENE (EPR) CABLES
Υ/∆
Υ/ ∆ (STAR / DEL
(STAR TA) ST
DELT ARTING
STARTING
Cable cross section: 4G x …mm2 + 3 x …mm2
MOTOR RATED RATED Cos ϕ RATED VOLTAGE mm
2
4 6 10 16 25 35 50 70
TYPE POWER VOLTAGE CURRENT DROP A max* 73 94 130 173 220 274 333 426
THREE-PHASE Kw HP V A % Maximum lenght in metres
380 0,90 9,89
L6W40T405 4 5,5 327 490
415 0,85 9,13
380 0,88 12,7
L6W55T405 5,5 7,5 260 389
415 0,82 12,5
380 0,90 17,0
L6W75T405 7,5 10 189 283 488
415 0,84 16,2
380 0,89 20,5
L6W93T405 9,3 12,5 157 237 408
415 0,83 19,9
380 0,90 24,2
L6W110T405 11 15 131 197 341 535
415 0,84 23,4
380 0,90 28,1
L6W130T405 13 17,5 111 169 293 460
415 0,85 27,0
4
380 0,88 32,1
L6W150T405 15 20 99 150 261 410
415 0,82 31,3
380 0,89 38,5
L6W185T405 18,5 25 80 122 214 337 517
415 0,83 37,5
380 0,87 47,3
L6W220T405 22 30 64 99,5 176 278 426
415 0,80 46,7
380 0,85 56,5
L6W260T405 26 35 53 83 148 236 362 502
415 0,79 55,7
380 0,87 63,8
L6W300T405 30 40 44 70,2 127 203 313 436
415 0,81 62,0
380 0,86 81,8
L6W370T405 37 50 - 52 96 157 243 340 476
415 0,80 79,4
Exposed cable laid at a temperature of 30°C, maximum conductor temperature of 90°C l6w-cavi-SD-50-en_c_te
TECHNICAL APPENDIX 80
L8W TRIFASE, 50 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EPR),
L8W
L8W,, 50 Hz: SIZING OF ETHYLENE-PROPILENE (EPR) CABLES
DOL (DIRECT ON LINE) ST ARTING
STARTING
2
Cable cross section: 4G x …mm
MOTOR RATED RATED Cos ϕ RATED VOLTAGE mm2 10 16 25 35 50 70 95 120
TYPE POWER VOLTAGE CURRENT DROP A max 75 100 127 158 192 246 298 346
THREE-PHASE Kw HP V A % Maximum lenght in metres
380 0,85 65,0
L8W300T405 30 40 65 110 173 244 344 475
415 0,84 59,0
380 0,87 81,0
L8W370T405 37 50 47 82 132 189 268 374 476
415 0,83 76,0
380 0,87 92,0
L8W450T405 45 60 - 69 113 163 233 327 417 516
415 0,83 88,5
380 0,86 110
L8W520T405 52 70 - - 91 133 192 271 347 430
415 0,82 104
380 0,87 118
L8W550T405 55 75 - - 82 121 176 250 321 399
415 0,83 110
4
380 0,87 124
L8W600T405 60 80 - - 77 114 166 236 305 378
415 0,83 118
380 0,88 138
L8W670T405 67 90 - - - 98 145 208 270 337
415 0,83 132
380 0,87 156
L8W750T405 75 100 - - - 84 125 182 237 296
415 0,82 148
380 0,87 172
L8W830T405 83 110 - - - - 111 162 212 266
415 0,82 163
380 0,87 192
L8W930T405 93 125 - - - - 95 142 187 236
415 0,83 180
Exposed cable laid at a temperature of 30°C, maximum conductor temperature of 90°C l8w-cavi-50-en_b_te
L8W TRIFASE, 50 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EPR),
L8W
L8W,, 50 Hz: SIZING OF ETHYLENE-PROPILENE (EPR) CABLES
Υ/
Υ/∆∆ (STAR / DEL
(STAR TA) ST
DELT ARTING
STARTING
Cable cross section: 4G x …mm2 + 3 x …mm2
MOTOR RATED RATED Cos ϕ RATED VOLTAGE mm
2
6 10 16 25 35 50 70 95
TYPE POWER VOLTAGE CURRENT DROP A max* 94 130 173 220 274 333 426 516
THREE-PHASE Kw HP V A % Maximum lenght in metres
380 0,85 65,0
L8W300T405 30 40 70 127 203 313 435
415 0,84 59,0
380 0,87 81,0
L8W370T405 37 50 52 96 157 244 341 478
415 0,83 76,0
380 0,87 92,0
L8W450T405 45 60 44 83 136 212 298 419
415 0,83 88,5
380 0,86 110
L8W520T405 52 70 - 67 112 176 248 350 484
415 0,82 104
380 0,87 118
L8W550T405 55 75 - 60 102 161 228 323 447
415 0,83 110
4
380 0,87 124
L8W600T405 60 80 - 56 96 152 216 306 425 541
415 0,83 118
380 0,88 138
L8W670T405 67 90 - - 83 133 191 271 378 483
415 0,83 132
380 0,87 156
L8W750T405 75 100 - - 71 116 167 239 334 427
415 0,82 148
380 0,87 172
L8W830T405 83 110 - - 62,2 103 149 214 301 385
415 0,82 163
380 0,87 192
L8W930T405 93 125 - - 53 89 131 189 267 343
415 0,83 180
Exposed cable laid at a temperature of 30°C, maximum conductor temperature of 90°C l8w-cavi-SD-50-en_b_te
81 TECHNICAL APPENDIX
L10W TRIFASE, 50 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EPR
L10W
L10W,, 50 Hz: SIZING OF ETHYLENE-PROPILENE (EPR) CABLES
DOL (DIRECT ON LINE) ST ARTING
STARTING
Cable cross section: 4G x …mm2
MOTOR RATED RATED Cos ϕ RATED VOLTAGE mm2 35 50 70 95 120 150 185 240
TYPE POWER VOLTAGE CURRENT DROP A max 158 192 246 298 346 399 456 538
THREE-PHASE Kw HP V A % Maximum lenght in metres
380 0,87 191
L10W930T405 93 125 - 96 143 188 237 286 336 411
415 0,84 180
380 0,86 235
L10W1100T405 110 150 - - 110 147 187 228 268 329
415 0,82 220
4
380 0,86 270
L10W1300T405 130 175 - - - 124 159 194 230 283
415 0,83 255
380 0,86 308
L10W1500T405 150 200 - - - - 135 166 198 245
415 0,84 285
Exposed cable laid at a temperature of 30°C, maximum conductor temperature of 90°C l10w-cavi-50-en_b_te
L10W TRIFASE, 50 Hz: DIMENSIONAMENTO CAVI PER ACQUA POTABILE DRINCABLE - WRAS 07 (EPR
L10W
L10W,, 50 Hz: SIZING OF ETHYLENE-PROPILENE (EPR) CABLES
Υ/
Υ/∆∆ (STAR / DEL
(STAR TA) ST
DELT ARTING
STARTING
Cable cross section: 4G x …mm2 + 3 x …mm2
MOTOR RATED RATED Cos ϕ RATED VOLTAGE mm
2
25 35 50 70 95 120 150 185
TYPE POWER VOLTAGE CURRENT DROP A max* 220 274 333 426 516 599 691 790
THREE-PHASE Kw HP V A % Maximum lenght in metres
380 0,87 191
L10W930T405 93 125 90 132 191 269 345 428 511
415 0,84 180
380 0,86 235
L10W1100T405 110 150 - 102 150 215 278 345 412 480
415 0,82 220
4
380 0,86 270
L10W1300T405 130 175 - 85 127 183 238 297 356 415
415 0,83 255
380 0,86 308
L10W1500T405 150 200 - - 107 157 205 257 310 362
415 0,84 285
Exposed cable laid at a temperature of 30°C, maximum conductor temperature of 90°C l10w-cavi-SD-50-en_b_te
TECHNICAL APPENDIX 82
SPLICE BETWEEN DROP CABLE AND MOTOR CABLE
GIUNZIONE TRA CAVO DI DISCESA E CAVO MOTORE
2
MOTOR FOUR-CORE DROP CABLE - SECTION (mm )
POWER kW TYPE OF SPLICE
TYPE
1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
Resin-filled method GR1 GR1 GR1 GR2 GR2 GR6 GR6 GR6 GR4 GR5 GR5 - - - - -
4OS
0,37 - 7,5 Heat-shrink method GT1 GT1 GT2 GT2 GT3 GT4 GT5 GT6 - - - - - - - -
L4C
Tape method Self-vulcanizing tape + self-vulcanizing sealing putty and PVC tape (1)
Resin-filled method - - GR1 GR2 GR2 GR6 GR6 GR6 GR4 GR5 GR5 - - - - -
L6C
4 - 37 Heat-shrink method - - GT2 GT2 GT3 GT4 GT5 GT6 - - - - - - - -
L6W
Tape method Self-vulcanizing tape + self-vulcanizing sealing putty and PVC tape (1)
Resin-filled method - - GR1 GR1 GR2 GR2 GR6 GR6 GR6 GR4 GR5 - - - - -
L6C
4 - 37 Heat-shrink method - - GT2 GT2 GT3 GT4 GT5 GT6 - - - - - - - -
L6W
Resin-filled method - - - GR1 GR1 GR1 GR1 GR1 GR1 GR2 GR2 GR2 GR6 GR6 GR6 GR4
L8W
L10W 30 - 300 Heat-shrink method - - - - - - - - - - - - - - - -
L12W
Tape method Self-vulcanizing tape + PVC tape
(1) Use self-vulcanizing sealing putty to fill in the gaps between the three-conductor cable and the ground cable in the area covered
83 TECHNICAL APPENDIX
CALCULATING THE SPEED OF THE FL
CALCULATING UID THA
FLUID T FL
THAT OWS
FLOWS
AROUND A SUBMERGED MOTOR AND SIZING OF THE
COOLING SLEEVE
The following formula is used to verify whether the speed of the fluid that flows around the motor of a submersible pump is high
enough to guarantee the proper cooling of the motor:
Q
v= 2
2
D2 d
π ⋅( − )
4 4
Where: Q in [m3/s] is the operating flow rate of the electric pump; only half of this flow is taken into account, because the fluid
which is sucked into the area of the filter (2), comes from the motor side (3) as well as from the pump side (1);
D in [m] corresponds to the diameter of the well;
d in [m] corresponds to the diameter of the motor (3);
v in [m/s] is the calculated speed of the fluid that flows around the motor.
Now, compare the speed thus calculated (v) with the minimum speed required for correct cooling of the motor (vm): if v ≥ vm it
means that the motor is properly cooled, if v < vm will be necessary to mount a cooling sleeve (4).
Example
Example:
An electric pump OZ630/12 (motor diameter d = 0.144 m) operates in an 8" well (well diameter D = 0.203 m) with flow rate
Q = 20 m3/h = 0.0055 m3/s.
Speed of fluid v = (0.0055/2) / {π·[(0.203)2/4 – (0.144)2/4]} = 0.17 m/s.
The minimum speed required for proper motor cooling is vm = 0.20 m/s.
Because v < vm, it will be necessary to mount a cooling sleeve.
The following formula is used to determine the maximum diameter of a cooling sleeve to be mounted on a submersible motor:
⎛ Q d2 ⎞
D = 4 ⋅ ⎜⎜ + ⎟
⎝ v ⋅π 4 ⎟⎠
Where: Q in [m3/s] is the operating flow rate of the electric pump; the entire flow is taken into account because the fluid comes
from the motor side (3) only;
D in [m] corresponds to the diameter of the cooling sleeve (4);
d in [m] corresponds to the diameter of the motors(3);
vm in [m/s] is the minimum speed of the fluid that flows around the motor.
If the electric pump operates at different flow rate, the minimum flow rate must be taken into account for calculating the diameter
of the cooling sleeve.
Example
Example:
A motor coupled to the electric pump OZ615/24 (motor diameter d = 0.144 m), which operates with flow rate
Q = 15 m3/h = 0.0042 m3/s, requires a minimum speed of the fluid of vm = 0.20 m/s.
Cooling sleeve diameter D = {4·[(0.0042/(0.2·π)+(0.144)2/4] }0.5 = 0.217 m.
TECHNICAL APPENDIX 84
ASYNCHRONOUS MOTOR STARTING SYSTEMS
STARTING
Direct Autotransformer
Suitable for low-power motors.
The pump is started with a voltage which is lower than
The starting current (Is) is much higher than the rated
the rated one.
current (In).
The Lowara panels use an autotransformer with a voltage
Starting current Is = In x 4 ÷ 8
that is 70% the value of the line voltage.
Starting torque Ts = Tn x 2 ÷ 3
The switch to the rated voltage occurs without any
interruptions of the power supply.
Indirect Rated voltage Un = 400 V
• Star/Delta
The starting current (Is) is three times less than the direct
starting current. Starting current
Starting current Is = In x 1.3 ÷ 2.7 Us
Starting torque Ts = Tn x 0.7 ÷ 1
In the star to delta changeover phase (approx. 70 ms) the
motor is not supplied and tends to reduce its rotation Starting torque
Is = In x 4÷8 x
( ) Un
= In x 3÷6
speed. Us
( )
2
• Impedances Ia
Starting current
( )
Us
Is = In x 4÷8 x = In x 3÷6
Un
1 = Direct SPEED’
2 = Star-Delta
Starting torque 3 = Impedances
4 = Autotransformer
( )
Us 2
Ts = Tn x 2÷3 x = Tn x 1÷1,5
Un
85 TECHNICAL APPENDIX
WATER REQUIREMENTS IN CIVIL USERS
Determination of the water requirement depends on the type of users and contemporaneity factor. The calculation
may be subject to regulations, standards or customs that may vary from country to country. The calculation method
shown below is an example based on practical experience, designed to provide a reference value and not a substi-
tute for detailed analytical calculation.
The consumption table shows the maximum values for each delivery point, depending on the plumbing amenities.
The sum of the water consumption values of each delivery point determines the maximum theoretical re-
quirement, which must be reduced according to the contemporaneity coefficient, because in actual fact the
delivery points are never used all together.
1
f = Coefficient for apartments with one bathroom and flush tank WC
(0,857 x Nr x Na)
1
f = Coefficient for apartments with one bathroom and controlled flushing system WC
(0,857 x Nr x Na)
1,03
f = Coefficient for apartments with two bathrooms and flush tank WC
(0,545 x Nr x Na )
0,8
f = Coefficient for apartments with two bathrooms and controlled flushing system WC
(0,727 x Nr x Na )
f= coefficient; Nr= number of delivery points; Na= number of apartments
The table of water requirements in civil users shows the maximum contemporaneity flow-rate values
based on the number of apartments and the type of WC for apartments with one bathroom and two bath-
rooms. As regards apartments with one bathroom, 7 drawing points have been taken into consideration, while 11
points have been considered for apartments with two bathrooms. If the number of drawing points or apartments is
different, use the formulas to calculate the requirement.
TECHNICAL APPENDIX 86
TABLE OF WATER REQUIREMENTS IN CIVIL USERS
87 TECHNICAL APPENDIX
WATER REQUIREMENTS FOR COMMUNITY BUILDINGS
The requirements of buildings intended for specific uses, such as offices, residential units, hotels, de-
partment stores, nursing homes and so on, are different from those of condominiums, and both their
global daily water consumption and the maximum contemporaneity flow rate are usually greater. The diagram
of water requirements for community buildings shows the maximum contemporaneity flow rate of
some types of communities, for guidance.
These requirements must be determined case by case with the utmost accuracy, using analytical calculation meth-
ods, according to particular needs and local provisions.
For seaside resorts, the flow rate must be increased by at least 20%.
TECHNICAL APPENDIX 88
NPSH
The minimum operating values that can be reached at the The maximum possible suction head for installation
pump suction end are limited by the onset of cavitation. depends on the value of the atmospheric pressure
(i.e. the elevation above sea level at which the pump
Cavitation is the formation of vapour-filled cavities within is installed) and the temperature of the liquid.
liquids where the pressure is locally reduced to a critical value,
or where the local pressure is equal to, or just below the To help the user, with reference to water temperature
vapour pressure of the liquid. (4° C) and to the elevation above sea level, the
following tables show the drop in hydraulic pressure
The vapour-filled cavities flow with the current and head in relation to the elevation above sea level, and
when they reach a higher pressure area the vapour the suction loss in relation to temperature.
contained in the cavities condenses. The cavities collide,
generating pressure waves that are transmitted to the Water
walls. These, being subjected to stress cycles, gradually temperature (°C) 20 40 60 80 90 110 120
become deformed and yield due to fatigue. This Suction
phenomenon, characterized by a metallic noise loss (m) 0,2 0,7 2,0 5,0 7,4 15,4 21,5
produced by the hammering on the pipe walls, is called
incipient cavitation.
Elevation above
sea level (m) 500 1000 1500 2000 2500 3000
The damage caused by cavitation may be magnified by
electrochemical corrosion and a local rise in Suction
temperature due to the plastic deformation of the loss (m) 0,55 1,1 1,65 2,2 2,75 3,3
walls. The materials that offer the highest resistance to
heat and corrosion are alloy steels, especially austenitic
steel. The conditions that trigger cavitation may be Friction loss is shown in the tables at pages 91-92 of
assessed by calculating the total net suction head, this catalogue. To reduce it to a minimum, especially
referred to in technical literature with the acronym in cases of high suction head (over 4-5 m.) or within
NPSH (Net Positive Suction Head). the operating limits with high flow rates, we
recommend using a suction line having a larger
The NPSH represents the total energy (expressed in m.) diameter than that of the pump’s suction port.
of the liquid measured at suction under conditions of It is always a good idea to position the pump as close
incipient cavitation, excluding the vapour pressure as possible to the liquid to be pumped.
(expressed in m.) that the liquid has at the pump inlet.
Make the following calculation:
To find the static height hz at which to install the
machine under safe conditions, the following formula Liquid: water at ~15°C γ = 1 kg/dm3
must be verified: Flow rate required: 30 m3/h
Head for required delivery: 43 m.
Suction lift: 3,5 m.
hp + hz ≥ (NPSHr + 0.5) + hf + hpv 1 The selection is an FHE 40-200/75 pump whose NPSH
required value is, at 30 m3/h, di 2,5 m.
where:
hp is the absolute pressure applied to the free liquid For water at 15 °C
surface in the suction tank, expressed in m. of
liquid; hp is the quotient between the barometric hp = Pa / γ = 10,33m, hpv = Pv / γ = 0,174m (0,01701 bar)
pressure and the specific weight of the liquid.
The Hf flow resistance in the suction line with foot
hz is the suction lift between the pump axis and the
valves is ~ 1,2 m.
free liquid surface in the suction tank, expressed
By substituting the parameters in formula 1 with the
in m.; hz is negative when the liquid level is
numeric values above, we have:
lower than the pump axis.
hf is the flow resistance in the suction line and its
10,33 + (-3,5) ≥ (2,5 + 0,5) + 1,2 + 0,17
accessories, such as: fittings, foot valve, gate
valve, elbows, etc. from which we have: 6,8 > 4,4
hpv is the vapour pressure of the liquid at the
operating temperature, expressed in m. of The relation is therefore verified.
liquid. hpv is the quotient between the Pv vapour
pressure and the liquid’s specific weight.
0,5 is the safety factor.
89 TECHNICAL APPENDIX
TECHNICAL APPENDIX VAPOUR PRESSURE PS VAPOUR
PRESSURE AND ρ DENSITY OF WATER TABLE
t T ps ρ t T ps ρ t T ps ρ
°C K bar kg/dm3 °C K bar kg/dm3 °C K bar kg/dm3
0 273,15 0,00611 0,9998 55 328,15 0,15741 0,9857 120 393,15 1,9854 0,9429
1 274,15 0,00657 0,9999 56 329,15 0,16511 0,9852 122 395,15 2,1145 0,9412
2 275,15 0,00706 0,9999 57 330,15 0,17313 0,9846 124 397,15 2,2504 0,9396
3 276,15 0,00758 0,9999 58 331,15 0,18147 0,9842 126 399,15 2,3933 0,9379
4 277,15 0,00813 1,0000 59 332,15 0,19016 0,9837 128 401,15 2,5435 0,9362
5 278,15 0,00872 1,0000 60 333,15 0,1992 0,9832 130 403,15 2,7013 0,9346
6 279,15 0,00935 1,0000 61 334,15 0,2086 0,9826 132 405,15 2,867 0,9328
7 280,15 0,01001 0,9999 62 335,15 0,2184 0,9821 134 407,15 3,041 0,9311
8 281,15 0,01072 0,9999 63 336,15 0,2286 0,9816 136 409,15 3,223 0,9294
9 282,15 0,01147 0,9998 64 337,15 0,2391 0,9811 138 411,15 3,414 0,9276
10 283,15 0,01227 0,9997 65 338,15 0,2501 0,9805 140 413,15 3,614 0,9258
11 284,15 0,01312 0,9997 66 339,15 0,2615 0,9799 145 418,15 4,155 0,9214
12 285,15 0,01401 0,9996 67 340,15 0,2733 0,9793 155 428,15 5,433 0,9121
13 286,15 0,01497 0,9994 68 341,15 0,2856 0,9788 160 433,15 6,181 0,9073
14 287,15 0,01597 0,9993 69 342,15 0,2984 0,9782 165 438,15 7,008 0,9024
15 288,15 0,01704 0,9992 70 343,15 0,3116 0,9777 170 433,15 7,920 0,8973
16 289,15 0,01817 0,9990 71 344,15 0,3253 0,9770 175 448,15 8,924 0,8921
17 290,15 0,01936 0,9988 72 345,15 0,3396 0,9765 180 453,15 10,027 0,8869
18 291,15 0,02062 0,9987 73 346,15 0,3543 0,9760 185 458,15 11,233 0,8815
19 292,15 0,02196 0,9985 74 347,15 0,3696 0,9753 190 463,15 12,551 0,8760
20 293,15 0,02337 0,9983 75 348,15 0,3855 0,9748 195 468,15 13,987 0,8704
21 294,15 0,24850 0,9981 76 349,15 0,4019 0,9741 200 473,15 15,550 0,8647
22 295,15 0,02642 0,9978 77 350,15 0,4189 0,9735 205 478,15 17,243 0,8588
23 296,15 0,02808 0,9976 78 351,15 0,4365 0,9729 210 483,15 19,077 0,8528
24 297,15 0,02982 0,9974 79 352,15 0,4547 0,9723 215 488,15 21,060 0,8467
25 298,15 0,03166 0,9971 80 353,15 0,4736 0,9716 220 493,15 23,198 0,8403
26 299,15 0,03360 0,9968 81 354,15 0,4931 0,9710 225 498,15 25,501 0,8339
27 300,15 0,03564 0,9966 82 355,15 0,5133 0,9704 230 503,15 27,976 0,8273
28 301,15 0,03778 0,9963 83 356,15 0,5342 0,9697 235 508,15 30,632 0,8205
29 302,15 0,04004 0,9960 84 357,15 0,5557 0,9691 240 513,15 33,478 0,8136
30 303,15 0,04241 0,9957 85 358,15 0,5780 0,9684 245 518,15 36,523 0,8065
31 304,15 0,04491 0,9954 86 359,15 0,6011 0,9678 250 523,15 39,776 0,7992
32 305,15 0,04753 0,9951 87 360,15 0,6249 0,9671 255 528,15 43,246 0,7916
33 306,15 0,05029 0,9947 88 361,15 0,6495 0,9665 260 533,15 46,943 0,7839
34 307,15 0,05318 0,9944 89 362,15 0,6749 0,9658 265 538,15 50,877 0,7759
35 308,15 0,05622 0,9940 90 363,15 0,7011 0,9652 270 543,15 55,058 0,7678
36 309,15 0,05940 0,9937 91 364,15 0,7281 0,9644 275 548,15 59,496 0,7593
37 310,15 0,06274 0,9933 92 365,15 0,7561 0,9638 280 553,15 64,202 0,7505
38 311,15 0,06624 0,9930 93 366,15 0,7849 0,9630 285 558,15 69,186 0,7415
39 312,15 0,06991 0,9927 94 367,15 0,8146 0,9624 290 563,15 74,461 0,7321
40 313,15 0,07375 0,9923 95 368,15 0,8453 0,9616 295 568,15 80,037 0,7223
41 314,15 0,07777 0,9919 96 369,15 0,8769 0,9610 300 573,15 85,927 0,7122
42 315,15 0,08198 0,9915 97 370,15 0,9094 0,9602 305 578,15 92,144 0,7017
43 316,15 0,09639 0,9911 98 371,15 0,9430 0,9596 310 583,15 98,70 0,6906
44 317,15 0,09100 0,9907 99 372,15 0,9776 0,9586 315 588,15 105,61 0,6791
45 318,15 0,09582 0,9902 100 373,15 1,0133 0,9581 320 593,15 112,89 0,6669
46 319,15 0,10086 0,9898 102 375,15 1,0878 0,9567 325 598,15 120,56 0,6541
47 320,15 0,10612 0,9894 104 377,15 1,1668 0,9552 330 603,15 128,63 0,6404
48 321,15 0,11162 0,9889 106 379,15 1,2504 0,9537 340 613,15 146,05 0,6102
49 322,15 0,11736 0,9884 108 381,15 1,3390 0,9522 350 623,15 165,35 0,5743
50 323,15 0,12335 0,9880 110 383,15 1,4327 0,9507 360 633,15 186,75 0,5275
51 324,15 0,12961 0,9876 112 385,15 1,5316 0,9491 370 643,15 210,54 0,4518
52 325,15 0,13613 0,9871 114 387,15 1,6362 0,9476 374,15 647,30 221,20 0,3154
53 326,15 0,14293 0,9862 116 389,15 1,7465 0,9460
54 327,15 0,15002 0,9862 118 391,15 1,8628 0,9445
G-at_npsh_a_sc
TECHNICAL APPENDIX 90
TABLE OF FLOW RESISTANCE IN 100 m OF STRAIGHT CAST
IRON PIPELINE (HAZEN-WILLIAMS FORMULA C=100)
91 TECHNICAL APPENDIX
FLOW RESISTANCE
The flow resistance is calculated using the equivalent pipeline length method according to the table below:
ACCESSORY DN
TYPE 25 32 40 50 65 80 100 125 150 200 250 300
Equivalent pipeline length (m)
45° bend 0,2 0,2 0,4 0,4 0,6 0,6 0,9 1,1 1,5 1,9 2,4 2,8
90° bend 0,4 0,6 0,9 1,1 1,3 1,5 2,1 2,6 3,0 3,9 4,7 5,8
90° smooth bend 0,4 0,4 0,4 0,6 0,9 1,1 1,3 1,7 1,9 2,8 3,4 3,9
Union tee or cross 1,1 1,3 1,7 2,1 2,6 3,2 4,3 5,3 6,4 7,5 10,7 12,8
Gate - - - 0,2 0,2 0,2 0,4 0,4 0,6 0,9 1,1 1,3
Non return valve 1,1 1,5 1,9 2,4 3,0 3,4 4,7 5,9 7,4 9,6 11,8 13,9
G-a-pcv_a_th
The table is valid for the Hazen Williams coefficient C = 100 (cast iron pipework). For steel pipework, multiply the
values by 1.41. For stainless steel, copper and coated cast iron pipework, multiply the values by 1.85.
When the equivalent pipeline length has been determined, the flow resistance is obtained from the table of
flow resistance.
The values given are guideline values which are bound to vary slightly according to the model, especially for gate
valves and non-return valves, for which it is a good idea to check the values supplied by the manufacturers.
TECHNICAL APPENDIX 92
VOL UMETRIC
OLUMETRIC
VOLUMETRIC CAP ACITY
CAPACITY
CAPACITY
Litres Cubic metres Cubic feet Cubic feet Imp. gal. US gal.
per minute per hour per hour per minute per minute per minute
l/min m3/h ft3/h ft3/min Imp. gal/min Us gal./min
1,0000 0,0600 2,1189 0,0353 0,2200 0,2642
16,6667 1,0000 35,3147 0,5886 3,6662 4,4029
0,4719 0,0283 1,0000 0,0167 0,1038 0,1247
28,3168 1,6990 60,0000 1,0000 6,2288 7,4805
4,5461 0,2728 9,6326 0,1605 1,0000 1,2009
3,7854 0,2271 8,0208 0,1337 0,8327 1,0000
PRESSURE
SURE
PRESSURE
PRES AND
ANDHEAD
HEAD
Newton per kilo Pascal bar Pound force per metre millimetre of
square metre square inch of water mercury
N/m2 kPa bar psi m H 2O mm Hg
1,0000 0,0010 1 x 10-5 1.45 x 10-4 1.02 x 10-4 0,0075
1000,0000 1,0000 0,0100 0,1450 0,1020 7,5006
1 x 105 100,0000 1,0000 14,5038 10,1972 750,0638
6894,7570 6,8948 0,0689 1,0000 0,7031 51,7151
9806,6500 9,8067 0,0981 1,4223 1,0000 73,5561
133,3220 0,1333 0,0013 0,0193 0,0136 1,0000
LENGTH
TH
LENGTH
LENG
millimetre centimetre metre inch foot yard
mm cm m in ft yd
VOLUME
V OLUME
OLUME
cubic metre litre millilitre imp. Gallon US gallon cubic foot
3
m litro ml imp. gal. US gal. ft3
93 TECHNICAL APPENDIX
FURTHER PRODUCT SELECTION AND DOCUMENTATION
DOCUMENTA
Xylect
Xylect is pump solution selection software with an extensive online database of product information across the entire
Lowara, and Vogel range of pumps and related products, with multiple search options and helpful project management
facilities. The system holds up-to-date product information on thousands of products and accessories.
The possibility to search by applications and the detailed information output given makes it easy to make the optimal
selection without having detailed knowledge about the Lowara and Vogel products.
TECHNICAL APPENDIX 94
FURTHER PRODUCT SELECTION AND DOCUMENTATION
DOCUMENTA
Xylect
The detailed output makes it easy to select the optimal pump from the given alternatives.
For more information about Xylect please contact Dimensional drawings appear on the screen and can be
our sales network or visit www.xylect.com. downloaded in dxf format.
95 TECHNICAL APPENDIX
Xylem
1) The tissue in plants that brings water upward from the roots;
2) a leading global water technology company.
Headquarters
LOWARA S.r.l. Unipersonale
Via Vittorio Lombardi 14
36075 Montecchio Maggiore - Vicenza - Italy
Tel.(+39) 0444 707111 - Fax(+39) 0444 492166
e-mail: lowara.mkt@xyleminc.com
web: www.lowara.com - www.completewatersystems.com
LOWARA reserves the right to make modification without prior notice.
LOWARA is a trademark of Xylem Inc. or one of its subsidiaries.