Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

SENTiFIT270 Brochure English

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

FOB Gold

LINE

The High-Speed
System for colorectal
cancer screening
FOB Gold
®
THE FULLY AUTOMATED QUANTITATIVE
LINE
FIT SYSTEM

Designed for the Fecal Immunochemical Test to detect


human hemoglobin

system

• Immunochemical determination
of human hemoglobin in feces
• High sensitive and specific
hemoglobin detection with FOB
Gold® latex reagent
• System detects appropriate level
of buffer and potential presence
of macroaggregates in sample
device, providing completely
reliable results.
• Continuous loading of samples
• Working speed
up to 270 tests/hour
• Automatic rerun of diluted
samples

Piercing probe

pierceTube

• Ready to use for the collection


of stool samples
• Hygienic and safe
• Patented pierceable tube
Piercing side (Patent No. EP2223656B1)
• Only one side opening
(collection side)
• Single step analysis: load
the SENTiFIT® pierceTube
onto the sample tray
and start testing
• Automated reading through
unique sample ID barcode label
Collection side
FOB Gold
®

LINE

CALIBRATION SAMPLE MONITORING

• Automatic check of • Calibrator Kit: liquid • Reaction curve • Automatic prozone


calibration curve: and ready to use visualization for each check to avoid any
calibration reliability • Automatic on-board sample reaction false negative results
• Calibration on-board dilution • Export data file • Complete sample
stability: 30 days (CSV format) traceability

MAIN SCREEN QC MONITOR

• One button start: • Sample tray • Daily and cumulative • Liquid and ready to use
easy to use monitoring: visual QC graphs for trend positive and negative
sample check monitoring controls for reliable
• Sample time
processing: workload • Reagent tray monitoring: patient results
• Export data file
optimization automatic update of (CSV format) for
remaining tests statistical analysis

WASHING STATION REAGENT TRAY

• 72 reading cuvettes, • Acid and alkaline • Refrigerated for long • Multiple (5 set)
checked after every test washing solutions: on-board reagent reagent vials loading:
accurate cuvette stability high capacity for long
• Semi-disposable
cuvettes: reduced waste cleaning with no working session
• Automatic reagent
sample carryover
and cost reduction barcode reader:
time-saving
FOB Gold
®

LINE
Ref. 1156188
SENTiFIT® pierceTube
100 pcs
• Buffer formulation with enhanced
hemoglobin stability

Ref. 1156008
SENTiFIT® FOB Gold® latex Wide
R1: 2 x 20 mL
R2: 2 x 20 mL
• Ready to use
• With dedicated barcode
• On-board stability: 30 days Ref. 1157501
FOB Gold ® Screen Diluent
2 x 20 mL
• Ready to use
• On-board stability: 30 days

Information reported in this document may vary without notice due to the continuous technological up date. NOT FOR THE US AND CANADIAN MARKET.
Ref. 1157103
FOB Gold ® Control Set Wide
2 x (1 x 2) mL Ref. 1157401

• Ready to use FOB Gold ® Calibrator Wide


• Negative and positive level Cal 1 x 2 mL + Dil 1 x 5 mL
• Open vials stability: 30 days • Ready to use
• Calibration stability: 30 days

Sentinel CH. SpA


WATCHING OVER LIFE

Via Robert Koch, 2


20152 Milan - Italy
Phone: +39 02 3455141
Fax: +39 02 34551464
DPL55W REV 02 9/18

sentinel@sentinel.it
www.sentineldiagnostics.com

You might also like