PDF Uwr6 10wa Series 3
PDF Uwr6 10wa Series 3
PDF Uwr6 10wa Series 3
FEATURES
■ Low Cost! Highly reliable!
■ Proven SMT-on-pcb construction
■ Designed to meet UL/EN/IEC 60950-1,
CAN/CSA-C22.2 60950-1
■ Qual tested; HALT tested; EMC tested PRODUCT OVERVIEW
Placing reliability and cost considerations above all others, DATEL’s new A-Series DC/DC
■ Small packages, 2" x 1" x 0.375" Converters combine straightforward circuit topologies, the newest components, proven SMT-on-pcb
■ Standard pinouts construction, and highly repeatable automatic assembly techniques. Considering the critical low-cost
and long-term-reliability requirements of today’s telecom, datacom and computer/networking appli-
■ 5, 5.2, 12 or 15 Volt outputs cations, the A-Series may well be the most cost-effective DC/DC’s available today.
■ Choice of 3 wide-range inputs: The single-output, 6-10 Watt Models of the A-Series deliver both high power densities and
impressive MTBF’s. Their superior durability is substantiated by a rigorous in-house qualification
4.7-7.25 Volts program including HALT (Highly Accelerated Life Testing). The goal of HALT is not to simulate field
9-18 Volts conditions but to expose devices to multiple excessive stresses with the intention of precipitating any
potential electrical, mechanical or process weaknesses.
18-75 Volts
Packaged in 2" x 1" x 0.375" shielded metal cases with non-conductive coatings, these fully
■ Fully isolated, 1500Vdc guaranteed isolated (1500Vdc guaranteed) DC/DC’s offer excellent line/load regulation, full I/O protection, and
industry-standard pinouts.
■ –40 to +100°C operation
Output voltages include 5, 5.2, 12 and 15 Volts. Input voltage ranges are either 4.7-7.25V ("D5A"
■ 5-side metal shielded cases with non- models), 9-18V ("D12A" models) or 18-75V ("D48A" models). All A-Series UWR models are fully EMI
conductive baseplates characterized and agency safety approved.
A-Series DC/DC’s are extremely reliable, easy-to-use, cost-effective power converters. Use
■ Modifications and customs for OEM’s
them to improve the reliability of existing equipment or to develop new systems that exceed design
objectives.
+VIN +VOUT
(1) (3)
COMMON
(5)
www.murata-ps.com/support
MDC_UWR6-10W Series.B04 Page 1 of 6
UWR Series
Single Output, High Reliability, 2" x 1", 6-10 Watt, DC/DC Converters
Performance Specifications and Ordering Guide ➀
Output Input
Package
VOUT * IOUT R/N (mVp-p) ➁ Regulation (Max.) VIN Nom. Range IIN ➃ Efficiency (Case,
Root Model ➅ (Volts) (mA) Typ. Max. Line Load ➂ (Volts) (Volts) (mA) Min. Typ. Pinout)
UWR-5/1600-D5A-C 5 1600 50 100 ±0.2% ±0.5% 5 4.7-7.25 20/2105 74% 76% C2, P11
UWR-5/1800-D48A-C 5 1800 75 100 ±0.2% ±0.5% 48 18-75 10/240 78% 81% C2, P11
UWR-5/2000-D12A-C 5 2000 50 75 ±0.2% ±0.5% 12 9-18 15/1029 79.5% 81% C2, P11
UWR-5/2000-D24E-C ➄ 5 2000 50 75 ±0.2% ±0.5% 24 18-36 10/490 83% 85% C2, P11
UWR-5/2000-D48E-C ➄ 5 2000 50 75 ±0.2% ±0.5% 48 36-72 10/248 82% 84% C2, P11
UWR-5.2/1500-D5A-C 5.2 1500 50 100 ±0.2% ±0.5% 5 4.7-7.25 20/2053 74% 76% C2, P11
UWR-12/665-D5A-C 12 665 75 100 ±0.2% ±0.5% 5 4.7-7.25 25/2046 75% 78% C2, P11
UWR-12/750-D48A-C 12 750 75 100 ±0.2% ±0.5% 48 18-75 10/230 81.5% 82.5% C2, P11
UWR-12/830-D12A-C 12 830 75 100 ±0.2% ±0.5% 12 9-18 35/988 81% 84% C2, P11
UWR-15/530-D5A-C 15 530 50 100 ±0.2% ±0.5% 5 4.7-7.25 40/2065 75% 77% C2, P11
UWR-15/600-D48A-C 15 600 75 100 ±0.2% ±0.5% 48 18-75 10/233 81.5% 84% C2, P11
UWR-15/665-D12A-C 15 665 75 100 ±0.2% ±0.5% 12 9-18 35/978 82% 85% C2, P11
➀ Typical at TA = +25°C under nominal line voltage and full-load conditions unless otherwise noted.
➁ Ripple/Noise (R/N) measured over a 20MHz bandwidth.
➂ 10% to 100% load.
➃ Nominal line voltage, no-load/full-load conditions.
➄ See Technical Notes for an explanation of trading off input voltage ranges for higher full-power operating temperature.
➅ Please see the Part Number Structure for complete ordering options.
U WR - 5 / 1800 - D48 A - C
2.00
RoHS-6 hazardous (50.8)
Output Configuration: substance
U = Unipolar compliant
METAL CASE
0.375 Case C2
A-Series (9.5)
Wide Range Input
High Reliability
INSULATED BASE
Nominal Output Voltage: Input Voltage Range: 0.040 ±0.002 DIA.
0.20 MIN
5, 5.2, 12 or 15 Volts D5 = 4.7-7.25 Volts (5V nominal) (5.1)
(1.016 ±0.051)
D
8 B
Dimensions are in inches (mm) shown for ref. only.
I/O Connections
7 E
Output Power (Watts)
www.murata-ps.com/support
MDC_UWR6-10W Series.B04 Page 2 of 6
UWR Series
Single Output, High Reliability, 2" x 1", 6-10 Watt, DC/DC Converters
Performance/Functional Specifications
Typical @ TA = +25°C under nominal line voltage and full-load conditions, unless noted. ➀
www.murata-ps.com/support
MDC_UWR6-10W Series.B04 Page 3 of 6
UWR Series
Single Output, High Reliability, 2" x 1", 6-10 Watt, DC/DC Converters
Typical Performance Curves (TA = +25°C)
The performance curves below were derived from actual test data for a single model number (UWR-5/1800-D48A).
Since all devices in the 6-10W UWR A-Series have the same circuit topology, the performance curves are representative of all devices.
Output Voltage vs. Input Voltage and Output Current Output Voltage vs. Output Current and Input Voltage
5.016 5.016
VIN = 18V
5.014 5.014
5.012 5.012
IOUT = 0.18A
VOUT (Volts)
VOUT (Volts)
5.010 5.010
5.008 5.008
IOUT = 0.9A
5.006 5.006
VIN = 72V
5.004 5.004
IOUT = 1.8A VIN = 48V
5.002 5.002
5.000 5.000
18 24 30 36 42 48 54 60 66 72 0.18 0.3 0.6 0.9 1.2 1.5 1.8
VIN (Volts) Output Current (Amps)
EFFICIENCY
81
78
Efficiency (%)
75
VIN = 18V
72
VIN = 48V
69
VIN = 72V
66
63
60
0.18 0.3 0.6 0.9 1.2 1.5 1.8
Output Current (Amps)
www.murata-ps.com/support
MDC_UWR6-10W Series.B04 Page 4 of 6
UWR Series
Single Output, High Reliability, 2" x 1", 6-10 Watt, DC/DC Converters
Input Fusing CUSTOM CAPABILITIES
Certain applications and/or safety agencies may require the installation of
fuses at the inputs of power conversion components. For DATEL A-Series DATEL’s world-class design, development and manufacturing team stands
UWR 6-10 Watt DC/DC Converters, you should use slow-blow type fuses ready to work with you to deliver the exact power converter you need for
with values no greater than the following: your demanding, large volume, OEM applications. And ... we’ll do it on
time and within budget!
VIN Range Fuse Value Our experienced applications and design staffs; quick-turn prototype
D5A 3A capability; highly automated, SMT assembly facilities; and in-line SPC
D12A and D24E 2A quality-control techniques combine to give us the unique ability to design
D48A and D48E 1A and deliver any quantity of power converters to the highest standards of
EMI RADIATED EMISSIONS quality and reliability.
If you’re designing with EMC in mind, please note that all of DATEL’s We have compiled a large library of DC/DC designs that are currently used
A-Series UWR 6-10 Watt DC/DC Converters have been characterized for in a variety of telecom, medical, computer, railway, aerospace and indus-
radiated and conducted emissions in our new EMI/EMC laboratory. Testing trial applications. We may already have the converter you need.
is conducted in an EMCO 5305 GTEM test cell utilizing EMCO automated Contact us. Our goal is to provide you the highest-quality, most cost-
EMC test software. Radiated emissions are tested to the limits of FCC Part effective power converters available.
15, Class B and CISPR 22 (EN 55022), Class B. Radiated emissions plots to Quality and Reliability
FCC and CISPR 22 for model UWR-12/665-D5A appear below.
The A-Series are the first DC/DC Converters to emerge from DATEL’s new,
company-wide approach to designing and manufacturing the most reliable
power converters available. The five-pronged program draws our Quality
Assurance function into all aspects of new-product design, development,
UWR-12/665-D5A Radiated Emissions characterization, qualification and manufacturing.
FCC Part 15 Class B, 3 Meters
Converter Output = 12Vdc @ 620mA Design for Reliability
80
Design for Reliability is woven throughout our multi-phased, new-product-
70 development process. Design-for-reliability practices are fully documented
60 and begin early in the new-product development cycle with the following
FCC Class B Limit
Radiated Emissions (dBµV/M)
50 goals:
1. To work from an approved components/vendors list ensuring the use of
40
reliable components and the rigorous qualification of new components.
30
2. To design with safety margins by adhering to a strict set of derating
20 guidelines and performing theoretical worst-case analyses.
10 3. To locate potential design weaknesses early in the product-development
0
cycle by using extensive HALT (Highly Accelerated Life Testing).
Radiated Emissions 4. To prove that early design improvements are effective by employing a
–10
thorough FRACA (Failure Reporting Analysis and Corrective Action) System.
–20
100 1000
Soldering Guidelines
Frequency (MHz)
UWR-12/665-D5A Radiated Emissions Murata Power Solutions recommends the specifications below when installing these
EN 55022 Class B, 10 Meters converters. These specifications vary depending on the solder type. Exceeding these
Converter Output = 12Vdc @ 620mA specifications may cause damage to the product. Be cautious when there is high atmo-
80 spheric humidity. We strongly recommend a mild pre-bake (100° C. for 30 minutes). Your
production environment may differ; therefore please thoroughly review these guidelines
70
with your process engineers.
60
Radiated Emissions (dBµV/M)
www.murata-ps.com/support
MDC_UWR6-10W Series.B04 Page 5 of 6
UWR Series
Single Output, High Reliability, 2" x 1", 6-10 Watt, DC/DC Converters
HALT Testing Qualification
The goal of the accelerated-stress techniques used by DATEL is to force For each new product, electrical performance is verified via a comprehen-
device maturity, in a short period of time, by exposing devices to excessive sive characterization process and long-term reliability is confirmed via a
levels of "every stimulus of potential value." We use HALT (Highly Acceler- rigorous qualification procedure. The qual procedure includes such strenu-
ated Life Testing) repeatedly during the design and early manufacturing ous tests as thermal shock and 500 hour life. Qual testing is summarized
phases to detect potential electrical and mechanical design weaknesses below.
that could result in possible future field failures. Qualification Testing
During HALT, prototype and pre-production DC/DC converters are sub- Qualification Test Method/Comments
jected to progressively higher stress levels induced by thermal cycling, HALT DATEL in-house procedure
rate of temperature change, vibration, power cycling, product-specific High Temperature Storage Max. rated temp., 1,000 hours
stresses (such as dc voltage variation) and combined environments. The Thermal Shock 10 cycles, –55 to +125°C
stresses are not meant to simulate field environments but to expose any Temperature/Humidity +85°C, 85% humidity, 48 hours
weaknesses in a product’s electro/mechanical design and/or assembly
Lead Integrity DATEL in-house procedure
processes. The goal of HALT is to make products fail so that device weak-
Life Test +70°C, 500 hours*
nesses can be analyzed and strengthened as appropriate. Applied stresses
Marking Permanency DATEL in-house procedure
are continually stepped up until products eventually fail. After corrective
End Point Electrical Tests Per product specification
actions and/or design changes, stresses are stepped up again and the cycle
is repeated until the "fundamental limit of the technology" is determined. * Interim electrical test at 200 hours.
DATEL has invested in a Qualmark OVS-1 HALT tester capable of applying In-Line Process Controls and Screening
voltage and temperature extremes as well as 6-axis, linear and rotational,
A combination of statistical sampling and 100% inspection techniques
random vibration. A typical HALT profile (shown above) consists of thermal
keeps our assembly line under constant control. Parameters such as
cycling (–55 to +125°C, 30°C/minute) and simultaneous, gradually increas-
solder-paste thickness, component placement, cleanliness, etc. are statisti-
ing, random longitudinal and rotational vibration up to 20G’s with load
cally sampled, charted and fine tuned as necessary. Visual inspections are
cycling and applied-voltage extremes added as desired. Many devices in
performed by trained operators after pick-and-place, soldering and cleaning
DATEL’s new A-Series could not be made to fail prior to reaching either the
operations. Units are 100% electrically tested prior to potting. All devices
limits of the HALT chamber or some previously known physical limit of the
are temperature cycled, burned-in, hi-pot tested and final-electrical tested
device.
prior to external visual examination, packing and shipping.
We also use the HALT chamber and its ability to rapidly cool devices to
verify their "cold-start" capabilities. Rapid Response to Problems
100
DATEL employs an outstanding corrective-action system to immediately
80 40 address any detected shortcomings in either products or processes. When-
ever our assembly, quality or engineering personnel spot a product/process
60
problem, or if a product is returned with a potential defect, we immediately
Temperature (°C)
40 20
perform a detailed failure analysis and, if necessary, undertake corrective
20 actions. Over time, this system has helped refine our assembly operation to
yield one of the lowest product defect rates in the industry.
0 0
–20
–40
10 20 30 40 50 60 70 80 90
www.murata-ps.com/support
MDC_UWR6-10W Series.B04 Page 6 of 6