Data sheet 3RP2525-1BB30

Timing relay, electronic on-delay 2 change-over contacts, 7 time ranges 0.05


s...100 h 24 V AC/DC at 50/60 Hz AC with LED, screw terminal

product brand name SIRIUS


product designation timing relay
design of the product slow-operating
product type designation 3RP25
General technical data
product component
● relay output Yes
● semi-conductor output No
product extension required remote control No
product extension optional remote control No
power loss [W] maximum 2W
insulation voltage for overvoltage category III according to IEC 300 V
60664 with degree of pollution 3 rated value
test voltage for isolation test 2.5 kV
degree of pollution 3
surge voltage resistance rated value 4 000 V
protection class IP IP20
shock resistance according to IEC 60068-2-27 11g / 15 ms
mechanical service life (operating cycles) typical 10 000 000
electrical endurance (operating cycles) at AC-15 at 230 V 100 000
typical
adjustable time 0.05 s ... 100 h
relative setting accuracy relating to full-scale value 5 %; +/-
thermal current 5A
recovery time 150 ms
reference code according to IEC 81346-2 K
relative repeat accuracy 1 %; +/-
influence of the surrounding temperature 1% in the whole temperature range to the set runtime
power supply influence 1% in the whole voltage range to the set runtime
Substance Prohibitance (Date) 09/12/2014
Control circuit/ Control
type of voltage of the control supply voltage AC/DC
control supply voltage 1 at AC
● at 50 Hz rated value 24 V
● at 60 Hz rated value 24 V
control supply voltage frequency 1 50 ... 60 Hz
control supply voltage 1 at DC
● rated value 24 V
operating range factor control supply voltage rated value at
DC
● initial value 0.85

3RP25251BB30 Subject to change without notice


7/3/2024
Page 1/6 © Copyright Siemens
● full-scale value 1.1
operating range factor control supply voltage rated value at
AC at 50 Hz
● initial value 0.85
● full-scale value 1.1
operating range factor control supply voltage rated value at
AC at 60 Hz
● initial value 0.85
● full-scale value 1.1
inrush current peak
● at 24 V 2A
duration of inrush current peak
● at 24 V 1 ms
Switching Function
switching function
● ON-delay Yes
● ON-delay/instantaneous contact No
● passing make contact No
● passing make contact/instantaneous contact No
● OFF delay No
switching function
● flashing symmetrically with interval start/instantaneous No
● flashing symmetrically with interval start No
● flashing symmetrically with pulse start/instantaneous No
● flashing symmetrically with pulse start No
● flashing asymmetrically with interval start No
● flashing asymmetrically with pulse start No
switching function
● star-delta circuit with delay time No
● star-delta circuit No
switching function with control signal
● additive ON-delay No
● passing break contact No
● passing break contact/instantaneous No
● OFF delay No
● OFF delay/instantaneous No
● pulse delayed No
● pulse delayed/instantaneous No
● pulse-shaping No
● pulse-shaping/instantaneous No
● additive ON-delay/instantaneous No
● ON-delay/OFF-delay/instantaneous No
● passing make contact No
● passing make contact/instantaneous contact No
switching function of interval relay with control signal
● retrotriggerable with deactivated control No
signal/instantaneous contact
● retrotriggerable with switched-on control signal No
● retrotriggerable with switched-on control No
signal/instantaneous contact
● retriggerable with deactivated control signal No
Short-circuit protection
design of the fuse link for short-circuit protection of the auxiliary fuse gL/gG: 4 A
switch required
Auxiliary circuit
material of switching contacts AgSnO2
number of NC contacts
● delayed switching 0
● instantaneous contact 0
number of NO contacts
● delayed switching 0
● instantaneous contact 0

3RP25251BB30 Subject to change without notice


7/3/2024
Page 2/6 © Copyright Siemens
number of CO contacts
● delayed switching 2
● instantaneous contact 0
operational current of auxiliary contacts at AC-15
● at 24 V 3A
● at 250 V 3A
operational current of auxiliary contacts at DC-13
● at 24 V 1A
● at 125 V 0.2 A
● at 250 V 0.1 A
operating frequency with 3RT2 contactor maximum 5 000 1/h
contact reliability of auxiliary contacts one incorrect switching operation of 100 million switching operations (17 V, 5
mA)
contact rating of auxiliary contacts according to UL R300 / B300
switching capacity current with inductive load 0.01 ... 3 A
Inputs/ Outputs
product function
● at the relay outputs switchover delayed/without delay No
● non-volatile No
Electromagnetic compatibility
EMC emitted interference according to IEC 61812-1 ambience A (industrial sector)
EMC immunity according to IEC 61812-1 corresponds to degree of severity 3
conducted interference
● due to burst according to IEC 61000-4-4 2 kV network connection / 1 kV control connection
● due to conductor-earth surge according to IEC 61000-4-5 2 kV
● due to conductor-conductor surge according to IEC 1 kV
61000-4-5
field-based interference according to IEC 61000-4-3 10 V/m
electrostatic discharge according to IEC 61000-4-2 4 kV contact discharge / 8 kV air discharge
Safety related data
category according to EN 954-1 none
Electrical Safety
protection class IP on the front according to IEC 60529 IP20
type of insulation Basic insulation
Connections/ Terminals
product component removable terminal for auxiliary and Yes
control circuit
type of electrical connection for auxiliary and control circuit screw-type terminals
type of connectable conductor cross-sections
● solid 1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
● finely stranded with core end processing 1x (0.5 ... 4 mm²), 2x (0.5 ... 1.5 mm²)
● for AWG cables solid 1x (20 ... 12), 2x (20 ... 14)
● for AWG cables stranded 1x (20 ... 12), 2x (20 ... 14)
connectable conductor cross-section
● solid 0.5 ... 4 mm²
● finely stranded with core end processing 0.5 ... 4 mm²
AWG number as coded connectable conductor cross
section
● solid 20 ... 12
● stranded 20 ... 14
tightening torque 0.6 ... 0.8 N·m
design of the thread of the connection screw M3
Installation/ mounting/ dimensions
mounting position any
fastening method screw and snap-on mounting onto 35 mm DIN rail
height 100 mm
width 22.5 mm
depth 90 mm
required spacing
● with side-by-side mounting
— forwards 0 mm
— backwards 0 mm

3RP25251BB30 Subject to change without notice


7/3/2024
Page 3/6 © Copyright Siemens
— upwards 0 mm
— downwards 0 mm
— at the side 0 mm
● for grounded parts
— forwards 0 mm
— backwards 0 mm
— upwards 0 mm
— at the side 0 mm
— downwards 0 mm
● for live parts
— forwards 0 mm
— backwards 0 mm
— upwards 0 mm
— downwards 0 mm
— at the side 0 mm
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
● during operation -25 ... +60 °C
● during storage -40 ... +85 °C
● during transport -40 ... +85 °C
relative humidity during operation 10 ... 95 %
Approvals Certificates
General Product Approval

Confirmation

EMV Test Certificates Marine / Shipping

KC Type Test Certific-


ates/Test Report

Marine / Shipping other Environment

Confirmation Environmental Con-


firmations

Further information
Information on the packaging
https://support.industry.siemens.com/cs/ww/en/view/109813875
Information- and Downloadcenter (Catalogs, Brochures,…)
https://www.siemens.com/ic10
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RP2525-1BB30
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RP2525-1BB30
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3RP2525-1BB30
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RP2525-1BB30&lang=en
Characteristic: Derating
https://support.industry.siemens.com/cs/ww/en/ps/3RP2525-1BB30/manual

3RP25251BB30 Subject to change without notice


7/3/2024
Page 4/6 © Copyright Siemens
15 C

25 C
A1

-K
18 NO

28 NO
16 NC

26 NC
A2

A2

last modified: 11/21/2022

3RP25251BB30 Subject to change without notice


7/3/2024
Page 5/6 © Copyright Siemens
3RP25251BB30 Subject to change without notice
7/3/2024
Page 6/6 © Copyright Siemens