Sample volume
Colorimetry 10µL/ test NX600V Series Products
Electrolytes 50µL/ 3 tests (Na, K, Cl)
With electrolyte With automatic With centrifugal
Data transmission to PC RS 232C (1 port), USB (2 port), LAN (1 port) measuring function dilution function separation function
Data print Thermal printer NX600V IC
Electrical requirements Single phase AC; 100 - 240 V ±10%; 50 to 60 Hz
NX600V
Display 7 inch color touch panel
Dimensions 470 (W) 360 (D) 370 (H) mm
Weight Approx. 27kg (NX600V IC) / Approx. 26kg (NX600V)
Option Items
Operating temperature 15 to 32°C (59 to 89 °F) Barcode Reader
Operating humidity 30 to 80% RH (no vapor condensation) Barcode reader is available as option
item to read sample ID on sample tube.
Altitude Up to 2,000 m (810 hPa)
DRI-CHEM NX600V (Product name: FUJI DRI-CHEM NX600V IC, FUJI DRI-CHEM NX600V, FUJI DRI-CHEM NX600iV )
10µL
/test
MSO – Medical Solu�ons
Rua do Facho nº 9 Edf. Altamira Loja A 3770-056 Oiã - Portugal Ref. No. NX600 VET E FXX-XB-0400 (21•01•F1079•F8598) Printed in Japan ©2020 FUJIFILM Corporation
+351 234 062 334 | +351 965 079 682 | geral@mso.pt
2 3
Test results
can be printed
❸ Press
❶ Set slide ❷ Set specimen
the Start key
Using the item code recorded on the slide, the item and lot number are
automatically identified. After pressing the start key everything through
the printing of the measurement data is fully automatic.
Reference solution
Once set, can be Sample Sample
used for up to (serum/plasma) (whole blood)
24 hours
Dilute solution
Place dedicated
tube here
Mixing cup
Holds 10 batches of dilute solution
Large 7-inch
intuitive LCD touch panel
Up to 12 tips (3 to 12 samples)
Tips The simple and easy-to-use operation
can be set at once
screen provides a swift transition
speed of 0.5 seconds or less for
stress-free operation. A rich variety
Set consumables for multiple samples at once of help screens are also provided.
This enables easy operation while
The layout is simpler than our previous models, and this makes it easier to set consumables.
checking illustrated usage and
Multiple tips can be set at once, which eliminates the need to set reference solution for each
maintenance procedures.
measurement. This reduces the frequency of consumable replacement.
• Setup screen • Results view • Date search
500
No Calibration Reduces biohazard risks
10 µL
/test
Microsample testing 128
test/h
High throughput
128 tests can be processed per hour.
The FUJI DRI-CHEM system uses dry type reagents
which are very stable. As the reagents are stable,
Used slides and tips fall automati-
cally into a disposal box. Reduces
calibration is not necessary and it utilizes a the risk of contact with specimens.
standard curve for the measurements. Variability
Only 10 µL of sample is required for each test. in the reagent lots are adjusted using the QC card.
470
(CRP: 5µL/test, ISE: 50µL/test, dead volume is
*ISE:Calibration and correction are not necessary. QC card is not attached.
necessary using automatic measurement.) A very Automatic dilution function
Width
useful feature especially in small animals. If there Easy reagent lot information input by QC card
Labor intensive operations like dispensing, mixing
is less sample, measurement can be done by Information for every reagent lot that
etc. are automated. The only user operation
manual pipetting. are needed for the measurement are
450
required is when selecting the dilution ratio.
easily input into the
machine using the QC card.
NX600V/NX600V IC scale for installation (mm) Rotate the catalog to perform measurement.
DRI-CHEM
600
FUJI DRI-CHEM SLIDE
DRI-CHEM
Two types of slides are provided for different test items. that could interfere with the serum
or plasma specimen. The high quality 400
of Fujifilm reagents is demonstrated y = 1.04x - 0.166 y = 0.99x + 3.06
Colorimetric method slide Potentiometric method slide r = 0.9991 r=0.993
by a comparison with the standard 200
Enzymes, General chemistry, and Immunology Electrolytes
measurement methods.
This multilayered slide is composed of dry Each slide comes with an ion selective film 0 200 400 600 800 1000
chemical ingredients needed for the electrode for each of Na, K, and Cl. Slides
Urease glutamate dehydrogenase method 1,2 -o-Dilauryl-rac-glycero-3-glutaric
reaction and other functional materials. quantify electrolytes in the sample by a acid -(6-methylresorufin) ester lipase assay
It quantifies enzymes and chemicals using potentiometric method.
colorimetric method.
Reference Sample (50µL)
Sample (10µL) fluid Realtime diagnosis
canine CRP test for NX600V can measure lipase
Bridge
Spreading layer
inflammation screening activity for canines
200
200
Centrifugal separation cup (IC cup) Time
100
Serum
Plasma
Separating
agent
Centrifugal separation traps the blood After separation, the plasma follows
The straw can be easily
cells with a large specific gravity on the groove and accumulates separately Clinical chemistry analyzer Clinical chemistry analyzer Immunoassay analyzer
removed simply by tilting it.
the outer side of the separating agent. in the bottom of the cup. • High throughput 190 test/ hour • Single sample rack v-T4, vc-TSH, v-COR, v-BA, v-PRG, vf-SAA
(colorimetry and ISE combined)
• 5 sample rack • Without centrifugal separation unit