Barksdale B1S B2S B1T B2T

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Bourdon Tube Switch

Features
Pressure Series B1S, B2S, B1T, B2T

High accuracy
High pressure up to 18,000 psi
Tamper-proof external adjustment
Single and dual switching capability
Water tight housing versions available (NEMA 4) B1T/B2T
(housed)
Applications
Oil & gas
Medical applications
Mining
Compressors
Power plants
Water pumps
Hydraulic power units
Pneumatic devices B1S/B2S
General industrial applications (stripped)

General Specifications*
Electrical All models incorporate Underwriters Pressure Housed models with proof pressure up to 7,200
Characteristics: Laboratories, Inc. and CSA Listed single Connection: psi and stripped models with proof pressure up
pole double throw snap-action switching to 6,000 psi; 1/4” NPT female; All higher pressure
elements. ranges: superpressure fitting for 1/4” O.D. tube.
Accuracy1: ± 1% of the adjustable range Approvals:
Switch: UL/CSA (optional): UL File E42816
Type: Single pole double throw (SPDT) snap CSA: Class 3231 02; File No. 022355-0.000
action; single or dual circuit Temperature Range:
Rating: Operating: -40° to +165°F (-40° to +74 °C)
10 amp @ 125/250 VAC Adjustment Remove protective hex cap to remove
3 amp @ 480 VAC adjustment screw.
Instructions:
0.5 amp @ 24 VDC Turn main unit adjustment screw clockwise
Wetted Parts: to lower setpoint, counterclockwise to raise
Process Fitting & setpoint.
Bourdon Tube: 316 series stainless steel For optional adjustable actuation value
(deadband) models, set the desired
Enclosure: Anodized aluminum DECREASING setpoint first and then turn
microswitch adjustment wheel counterclockwise
Electrical Connection:
to increase the amount of deadband until the
Stripped Model: 21” Free Leads
desired INCREASING setpoint is achieved.
Housed Model: Internal terminal strip via conduit con- Options: -UL/CSA approval (max rating 300 VAC)
nection -NEMA 4X
-Temperature stabilization and pre-cycle
Enclosure Ratings:
-Cleaned for oxygen service
Housed Model: NEMA 4
Shipping Weight:
* See product configurator for additional options.
1 ±1% for 32-110°F; ±2% for > 110°F; -2/+3°F for <32°F Stripped Model: 1.5 lbs. approximate

Wiring Code Housed Model: 2.5 lbs. approximate

NO 1 (Red)
Lead Circuit #1 Circuit #2 Wiring Diagram
Normally Closed Blue Orange C 1 (Purple)
NO (Red) NC 1 (Blue)
Common Purple Brown
C (Purple)
Normally Open Red Yellow NO 2 (Yellow)
NC (Blue)
C 2 (Brown)
P NC 2 (Orange)
INCR
P
IWCR

1
daniel.argumedo@gloeso.com www.gloeso.com
Bourdon Tube Switch Series B1S, B2S, B1T, B2T

Technical Drawing
INDICATOR LIGHT
-SL VARIATION ONLY
1/4 (6.35) T P. 4-3/8
2-3/16 (111.0)
(55.6) 1-7/16
6 FREE LEADS 1/2 NPS (12.7)
(TYP.) CONDUIT CONNECTION
21" LONG (36.5) 1-11/32 1-11/32
3/8 (34.1) (34.1)
1-9/16 1-9/16 (TYP.)
(39.7) (39.7) (8.74)
13/32
3 FREE 25/32 (10.3) 25/32
LEADS (19.8) T P. (19.8)
21" LONG
ADJUSTABLE
DIFFERENTIAL ADJUSTING SCREW
TERMINAL KNOB. ‘S 5-7/8
(3/8 SLOTTED HEX)
STRIP CLASS ONLY (149.0) REMOVE COVER
3 CONTACTS TO ADJUST
#6-32 SCREWS
5-1/4
(133.0) ADJUSTING SCREW
5.0 GROUND (3/8 SLOTTED HEX)
5.0 (127) SCREW CIRCUIT #1
7-1/16
(127) MAX. (179.0) REMOVE COVER
MAX. TO ADJUST
1/4
3/8 (6.35) ADJUSTING ADJUSTING
ADJUSTING SCREWS
(9.52) SCREW SCREW
(MAX.) 3/8 HEX (3/8 SLOTTED HEX)
3/8 HEX & SLOTTED
PANEL & SLOTTED CIRCUIT #2
THICKNESS 1/2 1/2
(12.7) ADJUSTING REMOVE COVER
(12.7)
1"-14 N.F. SCREW 1-1/16 TO ADJUST 1-1/16
1-1/4 DIA. (31.7) THREAD 1"-14 N.F. (27.0) (27.0)
THREAD 5/16 (7.94)
1-3/16 1-3/16 1/4 (6.35)
(30.2) (30.2) 1/4
5/8 (15.9) (6.35) 1/4
2-11/16 .968 1-11/32 (6.35)
LOCKNUT 13/32 13/32
(68.3) MAX. (24.6) (34.1) (10.3)
PRESSURE PORT 2-1/2 (63.5) (10.3)
PRESSURE PORT
1-11/32
B1S B2S PRESSURE
PORT PRESSURE (34.1)
PORT 2-1/2 (63.5)
B1T B2T
Dimension in inches (mm)

Product Configurator H B1T SS

Options
Hermetically sealed limit switch option
H UL & CSA Approval (only
(requires AA, CC, GH or HH limit switch) -CS 4
available with B1T & B2T)
NEMA 4X enclosure (only
Series -FX
available with B1T & B2T)
B1T Single Setpoint Housed -Z1 Cleaned for oxygen service
B2T Dual Setpoint Housed Extra wire length
-Wxxx
(XXX = inches)
B1S Single Setpoint Stripped
Factory preset
B2S Dual Setpoint Stripped -Sxxx
(consult factory)

Limit Switch1
Process Connection
10 amps @ 125/250 VAC; 3 amps @ 480 VAC;
-A (standard for pressure range 12, 48, 65, 120 1/4” NPT for 12, 32 & 48 Pressure
and 180) Blank Ranges & 1/4” Tube for 65, 120 &
180 Pressure Ranges (standard)
10 amps @ 125/250/480 VAC; 0.05 amps @
-B 125 VDC; 0.03 amps @ 250 VDC (standard for 1/4” NPT Female (available on 65,
pressure range 32) -P4
120, and 180 ranges only)
10 amps @ 125/250/480 VAC; 0.1 amps @
-H 125VDC; 0.05 amps @ 250 VDC (standard for
pressure range 32)
SS Stainless steel bourdon tube
10 amps @ 125/250 VAC; 3 amps @ 480 VAC;
Pressure Range
-M
0.5 amps @ 125 VDC; 0.25 amps @ 250 VDC Adjustable Range Approx. Deadband1, 2 Proof Proof
15 amps @ 125/250/480 VAC; 0.05 amps @ Decreasing - psi (bar) Increasing - psi (bar) (Actuation Value) B1T/B2T B1S/B2S
-S 125 VDC; 0.03 amps @ 250 VDC (adjustable
differentials) Min Max Min Max psi-(bar) psi (bar) psi (bar)

-GH 1 amp @ 125 VAC with Gold Contacts 12 50 (3.4) 1180 (80.3) 70 (4.8) 1200 (81.6) 11 - 27 (0.7 - 1.8) 1800 (122) 1500 (103)
32 160 (11) 3161 (211) 199 (13.5) 3200 (213) 16 - 39 (1.1 - 2.7) 4800 (327) 4000 (275)
-AA Hermetically sealed; 4 amps @ 125/250 VAC
48 240 (16) 4715 (321) 325 (21.7) 4800 (327) 40 - 85 (2.7 - 5.8) 7200 (490) 6000 (414)
-CC Hermetically sealed; 10 amps @ 125/250 VAC
65 325 (22) 6385 (434) 440 (29.9) 6500 (442) 54 - 115 (3.7 - 7.8) 9750 (663) 8125 (560)
Hermetically sealed; 1 amp @ 125 VAC with
-GH 120 3 600 (41) 11450 (779) 1150 (78) 12000 (816) 275 - 550 (18.7 - 37.4) 18000 (1224) 15000 (1034)
Gold Contacts
-HH Hermetically sealed; 5 amps @ 125/250 VAC 180 3 600 (41) 17450 (1187) 1150 (78) 18000 (1224) 275 - 550 (18.7 - 37.4) 18000 (1224) 15000 (1034)

1 Consult sales drawings for specific deadband values 5 Subject to change


2 Deadband values indicated when used with the “standard” limit switch
3 This range is not available with any agency approval (no -CS)
4 Limited to 300VAC (-CS: CSA only on B1S/B2S models and no UL)

฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀฀ ฀ ฀ ฀ ฀ ฀
฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀฀ 2