A B C D E

3000

4
3000

3
3000

STAFF REST ROOM CASHIER RESTAURANT

2
3000

STORAGE KITCHEN

3500 3500 3500 3500

GROUND FLOOR LAYOUT

Drawing - 1
A B C D E

3000

4
3000

CONFERENCE ROOM

OFFICE SPACE
3000

STAFF REST ROOM

2
3000

PANTRY/
LUNCH ROOM

3500 3500 3500 3500

FIRST AND SECOND FLOOR LAYOUT

Drawing - 2
A C E NOTES
Col. Col. Col.
300 x 300 300 x 300 300 x 300 1. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL
B-600x300 B-600x300
RELEVANT ARCHITECTURAL AND ENGINEERING DRAWINGS
5 AND SPECIFICATIONS.

2. CONCRETE MIX TO BE C25 WITH A MAXIMUM AGGREGATE


SIZE NOT GREATER THAN 20mm.
3000

125 Tk. 125 Tk. 3. SLAB OPENINGS' SIZE AND POSITION TO BE CHECKED
Col.
Col. WITH ARCHITECTURAL AND M&E DRAWINGS.
300 x 300 Col.
B-600x300 300 x 300 B-600x300 300 x 300 4. WATER PROOFING AS SPECIFIED TO BE APPLIED ON ALL
4 WATER RETAINING AND EXCLUDING SURFACES.

125 Tk. 125 Tk.


3000

LEGEND
Col. Col. Col.
300 x 300 B-600x300 300 x 300 B-600x300 300 x 300 LOAD BEARING MASONRY WALL
3

LOAD BEARING REINFORCED CONCRETE


3000

125 Tk. 125 Tk.


NON REINFORCED CONCRETE (LEAN CONCRETE)
Col. Col. Col.
300 x 300 B-600x300 300 x 300 B-600x300 300 x 300
MASS CONCRETE FILL
2

STRUCTURAL SUPPORT BELOW


125 Tk. 125 Tk.
B-450x225

B-450x225

B-450x225
3000

Col. Col. Col. ABBREVIATIONS


300 x 300 B-600x300 300 x 300 B-600x300 300 x 300
1 · COL. = COLUMN
7000 7000 · TK = THICKNESS
· EL = ELEVATION

- GENERAL ARRANGEMENT OF FIRST FLOOR · ℄ = CENTRE LINE


-
Scale: 1:100

Drawing - 3
A B C D E
Col. Col. Col. Col. Col.
225 x 225 225 x 225 225 x 225 225 x 225 225 x 225
5

125 Tk. 125 Tk. 125 Tk. 125 Tk.


3000

Col. Col. Col. Col. Col.


225 x 225 225 x 225 225 x 225 225 x 225 225 x 225
4
3000

125 Tk. 125 Tk. 125 Tk. 125 Tk.

Col. Col. Col. Col. Col.


225 x 225 225 x 225 225 x 225 225 x 225 225 x 225
3
3000

125 Tk. 125 Tk. 125 Tk. 125 Tk.

Col. Col. Col. Col. Col.


225 x 225 225 x 225 225 x 225 225 x 225 225 x 225
2

125 Tk. 125 Tk. 125 Tk. 125 Tk.


3000

Col. Col. Col. Col. Col.


225 x 225 225 x 225 225 x 225 225 x 225 225 x 225
1

3500 3500 3500 3500

- GENERAL ARRANGEMENT OF FIRST FLOOR


-
Scale: 1:100

Drawing - 4
A C D
NOTES

1. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL


5 RELEVANT ARCHITECTURAL AND ENGINEERING DRAWINGS AND
SPECIFICATIONS.

1000
2. CONCRETE GRADE
- COLUMNS - C25
- FOUNDATION - C25
3000

T8-01-200-B1
- SLAB - C25
1000 1000
3. UNLESS OTHERWISE INDICATED COVER TO MAIN REINFORCEMENT TO

1000
BE AS FOLLOWS
BEAMS = 30mm
4 SLAB:
TOP = 25mm

1000
BOTTOM = 25mm
T8-04-200-T1
11. 11T12-06-125B1 TO BE READ AS 11 Nos, HIGH YIELD BARS OF 12mm DIA,
T8-01-200-B1
BEARING IDENTIFICATION NO 06 PLACED AT 125mm CENTRES IN THE
3000

BOTTOM LAYER.

T8-04-200-T1 12. MINIMUM LAP IN REINFORCEMENT TO BE 52XØ SMALLER BAR


DIAMERER.(UNLESS SPECIFIED).

1000
3 13. THE ABBREVIATIONS:-
`R'-MILD STEEL OF CHARACTERISTIC STRENGTH 250 N/mm2 TO BS 4449,

1000
T8-01-200-B1
`T'-HIGH YIELD STEEL OF CHARACTERISTIC STRENGTH 500 N/mm2 TO
900 BS 4449 & 4461.
900
3000

7150
T8-04-200-T1

1000
2

1000
3000

T8-01-200-B1
T8-02-250-B2
T8-03-250-T2
1000

7000 7000

- REINFORCEMNT DETAILS OF FIRST FLOOR


-
Scale: 1:100

Drawing - 5
A C

7000

BREAK LINE 1
1200 2000 2000
650 330 330 650 1000 1000 650 330
3T12-04
3T16-05 3T16-06

3T16-01 850 370 3T16-02 (6m) 2T16-03 (4m) 370 850 850 370
1350 1350 1350
9T8-07-150 T8-07-250 9T8-07-150 9T8-07-150

BEAM-B1

NOTES
7000
1. CONCRETE GRADE
- BEAMS - C25
- SLAB - C25
BREAK LINE 1

1200
2. UNLESS OTHERWISE INDICATED COVER TO MAIN REINFORCEMENT TO
330 650
3T12-04 BE AS FOLLOWS
BEAMS = 30mm
SLAB:
TOP = 25mm
BOTTOM = 25mm

3. MINIMUM LAP IN REINFORCEMENT TO BE 52XØ SMALLER BAR


DIAMERER.(UNLESS SPECIFIED).
3T16-02 (6m) 2T16-03 (4m) 370 850 3T16-01
4. THE ABBREVIATIONS:-
1350 `R'-MILD STEEL OF CHARACTERISTIC STRENGTH 250 N/mm2 TO BS 4449,
T8-07-250 9T8-07-150 `T'-HIGH YIELD STEEL OF CHARACTERISTIC STRENGTH 500 N/mm2 TO
BS 4449 & 4461.

Drawing - 6
LOAD MAP

Color code

Live Load
2.5 5 5 3 3 2 5
(kN/m2)
Super Imposed
Dead Load 2 2 2 2 2 3 3
(kN/m2)
Staircase/Lobby/c
Remarks Car park Restaurant Storage Kitchen Staff rest room Toilets
orridor
Color code

Live Load
3 3 3 2 5
(kN/m2)
Super Imposed Dead
Load 2 2 2 3 3
(kN/m2)
Office space/
Remarks Pantry/ Lunchroom Staff rest room Toilets Staircase/Lobby/corridor
Conference room
Site : Proposed Building for ABC Sheet No : 1
Client: ABC Designed by : BK
Vendor: Checked by : Kiriparan
Descreption: Design of Structural Elements Date : 27-02-2021
DESIGN OF BEAMS

PROPOSED LAYOUT OF THE BUILDING

LOAD EVALUATION

Dead load (DL)


Self weight of beam = 24 x 0.6 x 0.3 = 4.32 kN/m

Load from one way slab,


Self-weight of the slab = 24 x 0.125 x 3 = 9.00 kN/m
SD load = 2 x 3 = 6.00 kN/m

Total Dead Load on Beam = 19.32 kN/m Total DL


19.32 kN/m

Live Load (LL)


Load from slab = 3 x 3 = 9.00 kN/m Total LL
9.00 kN/m

Ult Design Load on Beam = 1.4 x 19.32 + 1.6 x 9.00 = 41.45 kN/m Design Load
41.45 kN/m

Any other
comments
Site : Proposed Building for ABC Sheet No : 2
Client: ABC Designed by : BK
Vendor: Checked by : Kiriparan
Descreption: Design of Structural Elements Date : 27-02-2021
Design of Beams
Reference Description Output

DESIGN MOMENTS

Method 1: Based on code coefficients

Table 3.5 Total Design Ultimate Load, F = 41.45 x 7


BS 8110-1- = 290.14 kN F = 216.64 kN
1:1997

Bending moment at near middle of


end span = 0.09Fl
= 0.09 x 290.1 x 7
= 182.79 kNm Mspan1 = 182.79 kNm

Bending moment at first interior


support = 0.11Fl
= 0.11 x 290.1 x 7
= 223.41 kNm Msup1 = 223.41 kNm

Shear force at outer support = 0.45F


= 0.45 x 290.1
= 130.56 kN SFsup1 = 130.56kN

Shear force at first interior support = 0.6F


= 0.6 x 290.1
= 174.08 kN SFsup2 = 174.08kN

Method 2: Design Software

Section

Any other
comments
Site : Proposed Building for ABC Sheet No : 3
Client: ABC Designed by : BK
Vendor: Checked by : Kiriparan
Descreption: Design of Structural Elements Date : 27-02-2021
Design of Beams

Loading Diagram

Bending Moment Diagram

Shear Force Diagram

Deflection Diagram

Any other
comments
Site : Proposed Building for ABC Sheet No : 4
Client: ABC Designed by : BK
Vendor: Checked by : Kiriparan
Descreption: Design of Structural Elements Date : 27-02-2021
Design of Beams

DESIGN OF BEAM FOR MOMENTS

Bottom reinforcement on Span

Sagging moment from Method 1 = 182.8 kNm


Sagging moment from Method 2 = 169.1 kNm

Top reinforcement on Support

Hogging moment from Method 1 = 223.41 kNm


Hogging moment from Method 2 = 228.5 kNm

Any other
comments
Site : Proposed Building for ABC Sheet No : 5
Client: ABC Designed by : BK
Vendor: Checked by : Kiriparan
Descreption: Design of Structural Elements Date : 27-02-2021
Design of Beams

DESIGN OF BEAM FOR SHEAR

Shear force from Method 1 = 174.04 kNm


Shear force from Method 2 = 177.7 kNm

Any other
comments
Site : Proposed Building for ABC Sheet No : 6
Client: ABC Designed by : BK
Vendor: Checked by : Kiriparan
Descreption: Design of Structural Elements Date : 27-02-2021
Design of Beams

Any other
comments
Site : Proposed Building for ABC Sheet No : 1
Client: ABC Designed by : BK
Vendor: Checked by : Kiriparan
Descreption: Design of Structural Elements Date : 27-02-2021
DESIGN OF COLUMNS

PROPOSED LAYOUT OF THE BUILDING

LOAD EVALUATION

Axial Load on the column at the Ground floor

Shear force due total factored load from beam = 177.70 kN

Shear force due to total factored load from all floors = 177.70 x 3= 533.10 kN

Any other
comments
Site : Proposed Building for ABC Sheet No : 2
Client: ABC Designed by : BK
Vendor: Checked by : Kiriparan
Descreption: Design of Structural Elements Date : 27-02-2021
Design of Columns

Moments on the column at the Ground floor

Unfactored dead load on beam, W D = 19.32 kN

Total factored load on beam, W T = 41.45 kN

3
IB = 1/12bd = (1/12) x 300 x 5383 = 3893021800 mm3

KB1 = KB2 = IB/LB = 3893021800 / 7000 = 556145.97

3
IL = 1/12bd = (1/12) x 300 x 3003 = 675000000 mm3

KL = KU = I/L = 675000000 / 3600 = 187500.00

Fixed end moment - Left, FEML = WDL2/12


= 19 x 7 2 /12
= 78.89 kNm

Fixed end moment - Right, FEMR = WTL2/12


= 41 x 7 2 /12
= 169.25 kNm

Total out of balance fixed end moment, Mes


= FEMR - FEML
= 169.3 - 78.89
= 90.36 kNm

= 18.2 Mfu=18.2kNm

= 18.2 MfL=18.2kNm

Any other
comments
Site : Proposed Building for ABC Sheet No : 3
Client: ABC Designed by : BK
Vendor: Checked by : Kiriparan
Descreption: Design of Structural Elements Date : 27-02-2021
Design of Columns

DESIGN OF COLUMN USING SOFTWARE

Inputs

Outputs

Any other
comments
Site : Proposed Building for ABC Sheet No : 4
Client: ABC Designed by : BK
Vendor: Checked by : Kiriparan
Descreption: Design of Structural Elements Date : 27-02-2021
Design of Columns

Any other
comments