Question Bank: Sinhgad Institute of Technology & Science, Pune
Question Bank: Sinhgad Institute of Technology & Science, Pune
Question Bank: Sinhgad Institute of Technology & Science, Pune
Class:
Draw the block diagram of a point to point optical fiber link and
3. explain the function of blocks needed in it. 7 CO4 BTL:3
Develop the power loss model for the given 86 km long haul optical
fiber system with the given parameters. System operates at a
wavelength of 1300 nm. Mean power launched from the laser
transmitter is – 3 dBm. Cabled fiber loss is 0.4 dB/km, splice loss
4. 8 CO4 BTL:5
for the link is 0.1 dB/km, connectors used at transmitter and
receiver respectively is 1 dB. Mean power required at the APD
receiver when operating at 35 Mbps is -55 dBm. Propose the
required system margin
Propose the choice of design components including transmission
5. wavelength for the optical fiber system used for 25 Gbps.km. 8 CO4 BTL:5
Discuss the reasons for the selection of a particular component.