TECHNOLOGY DEPARTMENT

TECHNICAL DATA SHEET


LOW VOLTAGE BUILDING WIRE

Cable Description:
Cu / PVC 450 / 750 V H07V2-R 90 °C 50 mm2 RM G / Y

Design and Construction Data:


Reference Manufacturing Standards IEC 60228, IEC 60227-3, BS EN 50525-2-31
Max. Permissible Continuous Conductor Temp °C 90
Max. Conductor Short Circuit Temp for 5 Seconds °C 160 °C
Rated Voltage V 450 / 750
Conductor Size mm2 50
Conductor Material & Shape Copper & Stranded Class 2
non-compacted Round Shape
Insulation Material PVC
Nominal Insulation Thickness mm 1.40
Insulation Color YELLOW WITH GREEN STRIPES
Approximate Wire Overall Diameter mm 11.6
Electrical Data:
Max Conductor DC resistance @ 20 °C ohms/km 0.3870
Max Conductor AC resistance @ 90 °C (Two/Three) Conductors ohms/km 0.4941 / 0.4944
Max Conductor Short Circuit Current @ 1 Second KA 4.99
Current Carry Capacity @ 30 °C Ambient Temperature
Enclosed in conduit(1)
Two Insulated Conductors Single Phase ac or dc A 178
Three or Four Insulated Conductors Three Phase ac A 158
Clipped direct(2)
Two Insulated Conductors Single Phase ac or dc A 215
Three or Four Insulated Conductors Three Phase ac A 197
(1) Current carrying capacity based on IEE wiring regulation method B cables single ac or dc / three phase ac,
enclosed in conduit on a wall or in trunking etc. at 30 °C ambient temperature”.
(2) Current carrying capacity based on IEE wiring regulation method C cables single ac or dc / three phase , clipped
direct at 30 °C ambient temperature”.
* ref (IEE Wiring Regulations 17th edition Table 4D1A)
The Cable shall meet all Test requirements of: IEC/BS EN 60228, IEC 60227-3, BS EN 50525-2-31, IEC 60332-1
Packing Data:
Drum Type Non-Returnable
Length of Cable per drum (± 5%) m 1000
Drum Dimensions "Height x Width" (Approx.) m 0.9 x 0.71
Gross Weight (Approximate without Lagging) kg 510.9
Cable Marking:
BAHRA CABLES CO. KSA 50 MM2 CU/PVC 90 DEG C 450 / 750 V H07V2-R BS EN 50525-2-31 SASO 1320 TYPE 60227
IEC 01 FR IEC 60332-1 'Manufacturing Year Meter marking'
Cable Drawing

1 2

Description Cu / PVC 450 / 750 V H07V2-R 90 °C 50 mm2 RM G / Y Approx. Diameter


1 Copper conductor with round shape 8.76
2 PVC TI-3 Insulation 11.56

Inquiry No.: EP-1000241 (126491) ksalahuddin 13/08/2023

Product ID: 12164210 Page 1 / 1